GFK-GFV Series Installation, Operation, and Maintenance Manual
Page 4
Table of Contents
1 Introduction and Safety............................................................................................................................................................. 2
1.2 Safety terminology and symbols................................................................................................................................................2
1.3 User safety.....................................................................................................................................................................................2
1.5 Special hazards............................................................................................................................................................................ 3
1.6 Protecting the environment........................................................................................................................................................3
2 Transportation and Storage.......................................................................................................................................................3
2.1 Examine the delivery................................................................................................................................................................... 3
2.1.1 Examine the package.......................................................................................................................................................... 3
2.1.2 Examine the unit.................................................................................................................................................................. 3
2.3 Temperature ranges for transportation, handling and storage.............................................................................................4
3.4 The data plate.............................................................................................................................................................................. 5
4.1 Install the pump........................................................................................................................................................................... 6
4.1.1 Install with Wet well installation......................................................................................................................................... 6
4.1.2 Install with Free-standing installation................................................................................................................................7
4.2 Make the electrical connections................................................................................................................................................ 7
4.2.1 Connect the motor cable to the pump............................................................................................................................. 8
4.2.2 Connect the motor cable to the starter and monitoring equipment............................................................................ 8
4.3 Check the impeller rotation......................................................................................................................................................11
5.2 Start the pump........................................................................................................................................................................... 11
6.1 Change the coolant...................................................................................................................................................................12
6.1.1 Empty the coolant..............................................................................................................................................................12
6.1.2 Fill with coolant.................................................................................................................................................................. 12
6.2 Service the pump.......................................................................................................................................................................12
6.2.3 Service in case of alarm.................................................................................................................................................... 13
6.3 Replace the impeller................................................................................................................................................................. 13
6.3.1 Remove the impeller ........................................................................................................................................................ 13
6.3.2 Install the impeller............................................................................................................................................................. 13
7.1 The pump does not start.......................................................................................................................................................... 15
7.2 The pump does not stop when a level sensor is used..........................................................................................................15
7.3 The pump starts-stops-starts in rapid sequence................................................................................................................... 15
7.4 The pump runs but the motor protection trips......................................................................................................................16
7.5 The pump delivers too little or no water................................................................................................................................ 16
8.1 Motor data.................................................................................................................................................................................. 16
Table of Contents
GFK-GFV Series Installation, Operation, and Maintenance Manual1
Page 5
1 Introduction and Safety
1 Introduction and Safety
1.1 Introduction
Electrical hazardMagnetic fields hazard
Electrical Hazard:
CAUTION:
Purpose of the manual
The purpose of this manual is to provide necessary information for
working with the unit. Read this manual carefully before starting work.
Read and keep the manual
Save this manual for future reference, and keep it readily available at
the location of the unit.
Intended use
WARNING:
Operating, installing, or maintaining the unit in any way that
is not covered in this manual could cause death, serious personal injury, or damage to the equipment and the surroundings. This includes any modification to the equipment or use
of parts not provided by Xylem. If there is a question regarding the intended use of the equipment, please contact a Xylem representative before proceeding.
Other manuals
See also the safety requirements and information in the original manufacturer's manuals for any other equipment furnished separately for use
in this system.
Description of user and installer symbols
Specific information for personnel in charge of installing
the product in the system (plumbing and/or electrical
aspects) or in charge of maintenance.
Specific information for users of the product.
1.2 Safety terminology and symbols
About safety messages
It is extremely important that you read, understand, and follow the safety messages and regulations carefully before handling the product.
They are published to help prevent these hazards:
• Personal accidents and health problems
• Damage to the product and its surroundings
• Product malfunction
Hazard levels
Hazard levelIndication
DANGER:
WARNING:
CAUTION:
NOTICE:
Special symbols
Some hazard categories have specific symbols, as shown in the following table.
A hazardous situation which, if not
avoided, will result in death or serious injury
A hazardous situation which, if not
avoided, could result in death or
serious injury
A hazardous situation which, if not
avoided, could result in minor or
moderate injury
Notices are used when there is a
risk of equipment damage or decreased performance, but not personal injury.
1.3 User safety
All regulations, codes, and health and safety directives must be observed.
The site
• Observe lockout/tagout procedures before starting work on the
product, such as transportation, installation, maintenance, or service.
• Pay attention to the risks presented by gas and vapors in the work
area.
• Always be aware of the area surrounding the equipment, and any
hazards posed by the site or nearby equipment.
Qualified personnel
This product must be installed, operated, and maintained by qualified
personnel only.
Protective equipment and safety devices
• Use personal protective equipment as needed. Examples of personal protective equipment include, but are not limited to, hard hats,
safety goggles, protective gloves and shoes, and breathing equipment.
• Make sure that all safety features on the product are functioning
and in use at all times when the unit is being operated.
1.4 Ex-approved products
Follow these special handling instructions if you have an Ex-approved
unit.
Personnel requirements
These are the personnel requirements for Ex-approved products in potentially explosive atmospheres:
• All work on the product must be carried out by certified electricians
and Xylem authorized mechanics. Special rules apply to installations
in explosive atmospheres.
• All users must know about the risks of electric current and the
chemical and physical characteristics of the gas, the vapor, or both
present in hazardous areas.
• Any maintenance for Ex-approved products must conform to international and national standards (for example, IEC/EN 60079-17).
Xylem disclaims all responsibility for work done by untrained and unauthorized personnel.
Product and product handling requirements
These are the product and product handling requirements for Ex-approved products in potentially explosive atmospheres:
• Only use the product in accordance with the approved motor data.
• You must fully submerge the Ex-approved product during normal
operation. Dry running during service and inspection is only permitted outside the classified area.
• Before you start work on the product, make sure that the product
and the control panel are isolated from the power supply and the
control circuit, so they cannot be energized.
• Do not open the product while it is energized or in an explosive gas
atmosphere.
• Intrinsically safe circuits are normally required for the automatic level-control system by the level regulator if mounted in zone 0.
• The yield stress of fasteners must be in accordance with the approval drawing and the product specification.
• Do not modify the equipment without approval from an Ex-approved Xylem representative.
• Only use original Xylem spare parts that are provided by an Ex-approved Xylem representative.
• The thermal detectors that are fitted to the stator windings must be
connected correctly to a separate motor control circuit and in use.
The detectors disconnect the power supply to the motor timely.
This action prevents the rise of temperatures above the temperature value for the approval classification.
2GFK-GFV Series Installation, Operation, and Maintenance Manual
Page 6
Equipment
locked out by
Name .......................
DANGER
2 Transportation and Storage
• The width of flameproof joints is more than the values specified in
the tables of the IEC 60079–1 standard.
• The gap of flameproof joints is less than the values specified in Table 1 of the IEC 60079–1 standard.
• The flameproof joints are NOT intended to be repaired.
• The equipment must be submerged during normal operation.
Guidelines for compliance
Compliance is fulfilled only when you operate the unit within its intended use. Do not change the conditions of the service without the approval of an Ex-approved Xylem representative. When you install or maintain explosion proof products, always comply with the directive and applicable standards (for example, IEC/EN 60079–14).
Minimum permitted liquid level
See the dimensional drawings of the product for the minimum permitted liquid level according to the approval for explosion proof products.
If the information is missing on the dimensional drawing, the product
must be fully submerged. Level-sensing equipment must be installed if
the product can be operated at less than the minimum submersion
depth.
Monitoring equipment
For additional safety, use condition-monitoring devices. Examples of
condition-monitoring devices include, but are not limited to, the following:
• Level indicators
• Temperature detectors in addition to the stator thermal detectors
Any thermal detectors or thermal protection devices delivered with the
pump must be installed and in use at all times.
1.5 Special hazards
Biological hazards
The product is designed for use in liquids that can be hazardous to
your health. Observe these rules when you work with the product:
• Make sure that all personnel who may come into contact with biological hazards are vaccinated against diseases to which they may
be exposed.
• Observe strict personal cleanliness.
WARNING: Biological Hazard
Infection risk. Rinse the unit thoroughly with clean water before working on it.
Wash the skin and eyes
Follow these procedures for chemicals or hazardous fluids that have
come into contact with your eyes or your skin:
ConditionAction
Chemicals or hazardous fluids in
eyes
Chemicals or hazardous fluids on
skin
1. Hold your eyelids apart forcibly with your
fingers.
2. Rinse the eyes with eyewash or running
water for at least 15 minutes.
3. Seek medical attention.
1. Remove contaminated clothing.
2. Wash the skin with soap and water for at
least 1 minute.
3. Seek medical attention, if necessary.
Exceptional sites
CAUTION: Radiation Hazard
Do NOT send the product to Xylem if it has been exposed to
nuclear radiation, unless Xylem has been informed and appropriate actions have been agreed upon.
1.7 Spare parts
CAUTION:
Only use the manufacturer’s original spare parts to replace
any worn or faulty components. The use of unsuitable spare
parts may cause malfunctions, damage, and injuries as well
as void the warranty.
1.8 Warranty
For information about warranty, see the sales contract.
2 Transportation and Storage
2.1 Examine the delivery
2.1.1 Examine the package
1. Examine the package for damaged or missing items upon delivery.
2. Record any damaged or missing items on the receipt and freight
bill.
3. If anything is out of order, then file a claim with the shipping company.
If the product has been picked up at a distributor, make a claim directly to the distributor.
2.1.2 Examine the unit
1. Remove packing materials from the product.
Dispose of all packing materials in accordance with local regula-
tions.
2. To determine whether any parts have been damaged or are missing, examine the product.
3. If applicable, unfasten the product by removing any screws, bolts,
or straps.
Use care around nails and straps.
4. If there is any issue, then contact a sales representative.
2.2 Transportation guidelines
Precautions
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and
lock out power before servicing to prevent unexpected startup. Failure to do so could result in death or serious injury.
1.6 Protecting the environment
Emissions and waste disposal
Observe the local regulations and codes regarding:
• Reporting of emissions to the appropriate authorities
• Sorting, recycling and disposal of solid or liquid waste
• Clean-up of spills
GFK-GFV Series Installation, Operation, and Maintenance Manual3
Position and fastening
The unit can be transported either horizontally or vertically. Make sure
that the unit is correctly fastened during transportation, and cannot roll
or fall over.
Page 7
3 Product Description
2.2.1 Lifting
Always inspect the lifting equipment and tackle before starting any
work.
WARNING: Crush Hazard
1) Always lift the unit by its designated lifting points. 2) Use
suitable lifting equipment and ensure that the product is
properly harnessed. 3) Wear personal protective equipment.
4) Stay clear of cables and suspended loads.
NOTICE:
Never lift the unit by its cables or hose.
Lifting equipment
Lifting equipment is always required to handle the unit. The lifting
equipment must fulfill the following requirements:
• The minimum height between the lifting hook and the floor must be
sufficient to lift the unit. Contact a Xylem representative for more information.
• The lifting equipment must be able to hoist the unit straight up and
down, preferably without the need for resetting the lifting hook.
• The lifting equipment must be correctly anchored and in good condition.
• The lifting equipment must support the weight of the entire assembly. Only authorized personnel may use the lifting equipment.
• Two sets of lifting equipment must be used to lift the unit for repair
work.
• The lifting equipment must be dimensioned to lift the unit with any
remaining pumped media in it.
• The lifting equipment must not be oversized.
CAUTION: Crush Hazard
Over-dimensioned lifting equipment can lead to injury. A
site-specific risk analysis must be done.
Below –13°C (9°F), the viscosity increases such that the glycol mixture
will lose its flow properties. However, the glycol-water mixture will not
solidify completely and thus cannot harm the product.
2.4 Storage guidelines
Storage location
The product must be stored in a covered and dry location free from
heat, dirt, and vibrations.
NOTICE:
Protect the product against humidity, heat sources, and mechanical
damage.
NOTICE:
Do not place heavy weights on the packed product.
Long-term storage
If the unit is stored more than six months, then the following apply:
• Before operating the unit after storage, it must be inspected with
special attention to the seals and the cable entry.
• The impeller/propeller must be rotated every other month to prevent the seals from sticking together.
3 Product Description
3.1 Products included
Pump modelStandardEX
1305.180X
2.3 Temperature ranges for transportation,
handling and storage
Handling at freezing temperature
At temperatures below freezing, the product and all installation equipment, including the lifting gear, must be handled with extreme care.
Make sure that the product is warmed up to a temperature above the
freezing point before starting up. Avoid rotating the impeller/propeller
by hand at temperatures below the freezing point. The recommended
method to warm the unit up is to submerge it in the liquid which will be
pumped or mixed.
NOTICE:
Never use a naked flame to thaw the unit.
Unit in as-delivered condition
If the unit is still in the condition in which it left the factory - all packing
materials are undisturbed - then the acceptable temperature range
during transportation, handling and storage is: –50°C (–58ºF) to +60°C
(+140ºF).
If the unit has been exposed to freezing temperatures, then allow it to
reach the ambient temperature of the sump before operating.
Lifting the unit out of liquid
The unit is normally protected from freezing while operating or immersed in liquid, but the impeller/propeller and the shaft seal may
freeze if the unit is lifted out of the liquid into a surrounding temperature below freezing.
Follow these guidelines to avoid freezing damage:
1. Empty all pumped liquid, if applicable.
2. Check all liquids used for lubrication or cooling, both oil and waterglycol mixtures, for the presence of unacceptable amounts of water.
Change if needed.
Water-glycol mixtures: Units equipped with an internal closed-loop
cooling system are filled with a mixture of water and 30% glycol. This
mixture remains a flowing liquid at temperatures down to –13°C (9°F).
3.2 Pump design
The pump is submersible, and driven by an electric motor.
Intended use
The product is intended for moving wastewater, sludge, raw and clean
water. Always follow the application limits that are given in Technical
Reference on page 16. If there is a question regarding the intended
use of the equipment, please contact a local sales and service representative before proceeding.
DANGER: Explosion/Fire Hazard
Special rules apply to installations in explosive or flammable
atmospheres. Do not install the product or any auxiliary
equipment in an explosive zone unless it is rated explosionproof or intrinsically-safe. If the product is EN/ATEX-, MSHAor FM-approved, then see the specific EX information in the
Safety chapter before taking any further actions.
NOTICE:
Do NOT use the unit in highly corrosive liquids.
Spare parts
• Modifications to the unit or installation should only be carried out
after consulting with Xylem.
• Original spare parts and accessories that are authorized by Xylem
are essential for compliance. The use of other parts can invalidate
any claims for warranty or compensation. For more information contact your Xylem representative.
Model variants
H
SSuper high head
High head
4GFK-GFV Series Installation, Operation, and Maintenance Manual
Page 8
1
2
3
4
5
6
7
9
8
WS007964A
2
131214
22
21
20
17 1819161591011
8
7
6
5
4
3
1
23
24
WS006257A
XXYYYY YYY YYY YYYY
1
2
3
4
5
6
7
a
b
c
WS006265B
.
3 Product Description
Parts
Po-
Denomi-
si-
nation
tion
1ShaftStainless steel with an integrated rotor
2Stator
housing
3MotorFor information about the motor, see Technical Reference
4Mechani-
cal seal
5Oil hous-
ing
6ImpellerVortex
7Main
bearing
8Thermal
contact
9Support
bearing
3.3 Monitoring Equipment
The following applies to the monitoring equipment of the pump:
• The stator incorporates thermal contacts that are connected in series that activate the alarm at overtemperature.
• The thermal contacts open at 125°C (257°F).
• Ex-approved pumps must have thermal contacts that are connected
to the control panel.
• The sensors must be connected to either the SMR 311 monitoring
equipment or equivalent equipment.
• The monitoring equipment must be of a design that makes automatic restart impossible.
• Information in the junction box shows if the pump is equipped with
optional sensors
GFK-GFV Series Installation, Operation, and Maintenance Manual5
Includes coolant that lubricates and cools the seals;
acts as a buffer between the pumped fluid and the
electric motor
Non-clog
Single-row ball bearing
The pump is equipped with thermal contacts, see
Monitoring Equipment on page 5 .
Single-row ball bearing
Optional sensors
LD LD is a miniature float switch for detection of liquid in the stator
housing. Due to its design, it is best suited for pumps in a vertical
position. The LD sensor is installed in the bottom of the stator
housing.
3.4 The data plate
The data plate is a metal label that is located on the main body of the
products. The data plate lists key product specifications. Specially approved products also have an approval plate.
1. Curve code or Propeller code
2. Serial number
3. Product number
4. Country of origin
5. Additional information
6. Phase; type of current; frequency
7. Rated voltage
8. Thermal protection
9. Thermal class
10.Rated shaft power
11.International standard
12.Degree of protection
13.Rated current
14.Rated speed
15.Maximum submergence
16.Direction of rotation: L=left, R=right
17.Duty class
18.Duty factor
3
19.Product weight
20.Locked rotor code letter
21.Power factor
22.Maximum ambient temperature
23.Read installation manual
24.Notified body, only for EN-approved Ex products
Figure 1: The data plate
3.5 Product denomination
Reading instruction
In this section, code characters are illustrated accordingly:
X = letter
Y = digit
The different types of codes are marked up with a, b and c. Code pa-
rameters are marked up with numbers.
Codes and parameters
Page 9
Equipment
locked out by
Name .......................
DANGER
WS007761A
4 Installation
Type of CalloutNumber Indication
Type of codeaSales denomination
bProduct code
cSerial number
Parameter1Hydraulic end
2Type of installation
3Sales code
4Version
5Production year
6Production cycle
7Running number
4 Installation
4.1 Install the pump
Before starting work, make sure that the safety instructions in the chapter Introduction and Safety on page 2 have been read and understood.
DANGER: Electrical Hazard
Before starting work on the unit, make sure that the unit and
the control panel are isolated from the power supply and
cannot be energized. This applies to the control circuit as
well.
• Check that the cable and cable entry have not been damaged during transport.
• Always check the impeller rotation before lowering the pump into
the pumped liquid.
NOTICE:
Do not run the pump dry.
NOTICE:
Never force piping to make a connection with a pump.
Authority regulation
Vent the tank of a sewage station in accordance with local plumbing
codes.
Fasteners
• Only use fasteners of the correct size and material.
• Replace all corroded or damaged fasteners.
• Make sure that all the fasteners are correctly tightened and that
there are no missing fasteners.
4.1.1 Install with Wet well installation
In the wet-well installation, the pump is installed on a stationary discharge connection, and operates either completely or partially submerged in the pumped liquid. These requirements and instructions only apply when the installation is made according to the dimensional
drawing.
DANGER: Inhalation Hazard
Before entering the work area, make sure that the atmosphere contains sufficient oxygen and no toxic gases.
Hazardous atmospheres
DANGER: Explosion/Fire Hazard
Special rules apply to installations in explosive or flammable
atmospheres. Do not install the product or any auxiliary
equipment in an explosive zone unless it is rated explosionproof or intrinsically-safe. If the product is EN/ATEX-, MSHAor FM-approved, then see the specific EX information in the
Safety chapter before taking any further actions.
WARNING: Explosion/Fire Hazard
Do not install CSA-approved products in locations that are
classified as hazardous in the National Electric Code(TM),
ANSI/NFPA 70-2005.
General requirements
These requirements apply:
• Use the pump dimensional drawing in order to ensure proper installation.
Before installing the pump, do the following:
• Provide a suitable barrier around the work area, for example, a
guard rail.
• Make sure that equipment is in place so that the unit cannot roll or
fall over during the installation process.
• Check the explosion risk before you weld or use electric hand tools.
Figure 2: Wet well installation
These items are required:
• Guide bars
• Guide bar bracket for attaching the guide equipment to the access
frame or to the upper part of the sump
• Level regulators or other control equipment for start, stop, and
alarm
• Cable holder for holding the cable and regulating the height of the
level regulators
• Access frame (with covers) to which the upper guide bar bracket
and cable holder can be attached
• Discharge connection for connecting the pump to the discharge
line
The discharge connection has a flange which fits the pump housing
flange and a bracket for attaching the guide equipment.
• Fasteners for the discharge connection
• Anchor bolts
6GFK-GFV Series Installation, Operation, and Maintenance Manual
Page 10
WS007762A
Equipment
locked out by
Name .......................
DANGER
4 Installation
1. Run a cable between the sump and the stator and monitoring
equipment.
Make sure that the cable is not sharply bent or pinched.
2. Install the access frame:
a) Place the access frame in position and align it horizontally.
b) Grout the frame in place.
3. Grout the anchor bolts in place.
Be careful when you align and position the discharge connection in
relation to the access frame.
4. Place the discharge connection in position, and tighten the nuts.
5. Install the guide bars:
a) Secure the guide bars in the bracket.
b) Check that the guide bars are placed vertically. Use a level or a
plumb line.
6. Connect the discharge pipe to the discharge connection.
7. Prepare for the level regulator:
a) Bolt the cable holder to the access frame.
b) Attach the level regulator cable to the cable holder and adjust
the height of the level regulator.
c) Protect bolts and nuts with a corrosion-preventive compound.
8. Lower the pump along the guide bars.
9. Secure the motor cable:
a) Fasten the permanent lifting device to the pump and to the ac-
cess frame. For example, you can use a stainless-steel lifting
chain with shackles.
b) Fasten the cable to the cable holder.
Make sure that the cable cannot be sucked into the pump inlet
or that it is neither sharply bent, or pinched. Support straps are
required for deep installations.
c) Connect the motor cable and the starter and monitoring equip-
ment according to the separate instructions.
Make sure that the impeller rotation is correct. For more infor-
mation, see Check the impeller rotation on page 11.
Clean all debris from the sump before starting the pump.
4.1.2 Install with Free-standing installation
In the Free-standing installation, the pump is transportable and intended to operate either completely or partially submerged in the pumped
liquid. The pump is equipped with a connection for hose or pipe and
stands on a base stand.
The stand is integrated with the pump housing and the hose is connected to pump using thread coupling.
These requirements and instructions only apply when the installation is
made according to the dimensional drawing.
1. Run the cable so that it has no sharp bends. Make sure that it is not
pinched, and cannot be sucked into the pump inlet.
2. Connect the discharge line.
3. Lower the pump into the sump.
4. Place the pump on the base and make sure it cannot fall over or
sink.
Alternatively, the pump can be suspended with a lifting chain just
above the sump bottom. Make sure that the pump cannot rotate at
startup or during operation.
5. Connect the motor cable and the starter and monitoring equipment
according to the separate instructions.
Make sure that the impeller rotation is correct. For more information, see Check the impeller rotation on page 11.
4.2 Make the electrical connections
General precautions
DANGER: Electrical Hazard
Before starting work on the unit, make sure that the unit and
the control panel are isolated from the power supply and
cannot be energized. This applies to the control circuit as
well.
WARNING: Electrical Hazard
Risk of electrical shock or burn. A certified electrician must
supervise all electrical work. Comply with all local codes and
regulations.
WARNING: Electrical Hazard
There is a risk of electrical shock or explosion if the electrical
connections are not correctly carried out, or if there is fault or
damage on the product. Visually inspect equipment for damaged cables, cracked casings or other signs of damage.
Make sure that electrical connections have been correctly
made.
Figure 3: Free-standing installation
GFK-GFV Series Installation, Operation, and Maintenance Manual7
WARNING: Crush Hazard
Risk of automatic restart.
CAUTION: Electrical Hazard
Prevent cables from becoming sharply bent or damaged.
NOTICE:
Leakage into the electrical parts can cause damaged equipment or a
blown fuse. Keep the cable ends dry at all times.
Requirements
These general requirements apply for electrical installation:
• The supply authority must be notified before installing the pump if it
will be connected to the public mains. When the pump is connected to the public power supply, it may cause flickering of incandescent lamps when started.
• The mains voltage and frequency must agree with the specifications
on the data plate. If the pump can be connected to different voltages, then the connected voltage is specified by a yellow sticker close
to the cable entry.
• The fuses and circuit breakers must have the proper rating, and the
pump overload protection (motor protection breaker) must be connected and set to the rated current according to the data plate and
Page 11
WS000509E
L2
L3L1
L1
L3L2
T1
T2
4 Installation
if applicable the cable chart. The starting current in direct-on-line
start can be up to six times higher than the rated current.
• The fuse rating and the cables must be in accordance with the local
rules and regulations.
• If intermittent operation is prescribed, then the pump must be provided with monitoring equipment supporting such operation.
• If stated on the data plate, then the motor is convertible between
different voltages.
• The thermal contacts/thermistors must be in use.
Cables
These are the requirements to follow when you install cables:
• The cables must be in good condition, not have any sharp bends,
and not be pinched.
• The cables must not be damaged and must not have indentations
or be embossed (with markings, etc.) at the cable entry.
• The cable entry seal sleeve and washers must conform to the outside diameter of the cable.
• The minimum bending radius must not be below the accepted value.
• If using a cable which has been used before, a short piece must be
peeled off when refitting it so that the cable entry seal sleeve does
not close around the cable at the same point again. If the outer
sheath of the cable is damaged, then replace the cable.
Contact a sales or authorized service representative.
• The voltage drop in long cables must be taken into account. The
drive unit’s rated voltage is the voltage measured at the cable connection point in the pump.
• For SUBCAB® cables, the twisted pair copper foil must be trimmed.
• All unused conductors must be insulated.
Grounding (earthing)
Grounding (earthing) must be done in compliance with all local codes
and regulations.
DANGER: Electrical Hazard
All electrical equipment must be grounded (earthed). Test
the ground (earth) lead to verify that it is connected correctly
and that the path to ground is continuous.
WARNING: Electrical Hazard
If the power cable is jerked loose, then the ground (earth)
conductor must be the last conductor to come loose from its
terminal. Make sure that the ground (earth) conductor is longer than the phase conductors at both ends of the cable.
8. Install the stator housing.
9. Install the entry gland screw on the stator housing.
4.2.2 Connect the motor cable to the starter and
monitoring equipment
DANGER: Explosion/Fire Hazard
Special rules apply to installations in explosive or flammable
atmospheres. Do not install the product or any auxiliary
equipment in an explosive zone unless it is rated explosionproof or intrinsically-safe. If the product is EN/ATEX-, MSHAor FM-approved, then see the specific EX information in the
Safety chapter before taking any further actions.
NOTICE:
Thermal contacts are incorporated in the pump.
NOTICE:
Thermal contacts must never be exposed to voltages higher than
250 V, breaking current maximum 5 A. It is recommended that they are
connected to 24 V over separate fuses to protect other automatic
equipment.
1. If thermal contacts are included in the pump installation, then connect the T1 and T2 control conductors to the monitoring equipment.
2. Connect the mains leads (L1, L2, L3, and ground (earth)) to the starter equipment.
For information about the phase sequence and the color codes of
the leads, see Cable charts.
3. Check the functionality of the monitoring equipment:
a) Check that the signals and the tripping function work properly.
b) Check that the relays, lamps, fuses, and connections are intact.
Replace any defective equipment.
4.2.3 Cable charts
Description
This topic contains general connection information. It also provides cable charts that show connection alternatives for use with different cables and power supply.
WARNING: Electrical Hazard
Risk of electrical shock or burn. You must connect an additional ground- (earth-) fault protection device to the grounded (earthed) connectors if persons are likely to come into
contact with liquids that are also in contact with the pump or
pumped liquid.
4.2.1 Connect the motor cable to the pump
NOTICE:
Leakage into the electrical parts can cause damaged equipment or a
blown fuse. Keep the end of the motor cable dry at all times.
1. Remove the entry gland screw from the stator housing.
2. Remove the stator housing.
This provides access to the terminal block/closed end splices.
3. Check the data plate to see which connections are required for the
power supply.
4. Arrange the connections on the terminal block/closed end splices
in accordance with the required power supply.
5. Connect the mains leads (L1, L2, L3, and ground (earth) ) according
to applicable cable chart.
The ground (earth) lead must be 50 mm (2.0 in.) longer than the
phase conductors in the junction box of the unit.
6. Make sure that the pump is correctly connected to ground (earth).
7. Make sure that any thermal contacts incorporated in the pump are
properly connected to the terminal block/closed end splices.
Figure 4: Phase sequence
Connection locations
The figures in this section illustrate how to interpret the connection
strip symbols.
8GFK-GFV Series Installation, Operation, and Maintenance Manual
Page 12
1
2
3
4
L1 L2 L3
T3 T4T1 T2
GC
*YE
GN/YE
WH
L1
U1
U2
W2
V2
W1
V1
L3
L2
U1
V1
W1
U2
W2
V2
U1 V1 W1 W2
U2
V2
U1 V1 W1 W2
U2
V2
L1
L2
L3
WS007735A
1. Stator leads
L1 L2 L3
T3 T4T1 T2
4321
5
8
6
LD
9
7
WS004846B
772 17 05/rev4
Motor connection
Colors and marking of main leads
COLOR STANDARD
STATOR LEADS
BN = Brown
U1,U5 = RD
BK = Black
U2,U6 = GN
WH = White
V1,V5 = BN
OG = Orange
V2,V6 = BU
GN = Green
W1,W5 = YE
GN/YE = Green-Yellow
W2,W6 = BK
RD = Red
T1,T2 = WH/YE
GY = Grey
BU = Blue
YE = Yellow
*SUBCAB AWG
* * Ground Conductor is stranded around cores
GC=Ground Check
Mains
1
3
SUBCAB 7GX
H07RN-F
SUBCAB 4GX
SUBCAB AWG
1
L1
BK 1
BK 1
BN
RD
2
L2
BK 2
BK 2
BK
BK
3
L3
BK 3
BK 3
GY
WH
L1
BK 4
BK 4
-
-
L2
BK 5
BK 5
-
-
L3
BK 6
BK 6
-
-
GN/YE
GN/YE
GN/YE
GN/YE
GC
-
-
-
YE
WS004600E
3 PHASE 6 Leads
Y
L1
U1
U2
W2
V2
W1
V1
L3
L2
U1
V1
W1
U2
W2
V2
U1
V1
W1
W2
U2
V2
U1
V1
W1
GC
W2
U2
V2
L1
L2
L3
*YE
GN/YE
D
L1
W2
U1
W1
U2
L3
V2
V1
L2
U1
V1
W1
W2
U2
V2
U1
V1
W1
W2
U2
V2
U1
V1
W1
W2
U2
V2
GC
L1
L2
L3
*YE
GN/YE
Y/D
L1:1
L2:1
L3:1
L1:2
L2:2
L3:2
U1
V1
W1
U2
V2
W2
U1
V1
W1
W2
U2
V2
U1
V1
W1
W2
U2
V2
U1
V1
W1
W2
U2
V2
GC
1
2
3
4
L2
L3
L1
L2
L1
5
6
L3
GN/YE
*YE
WS004601B
2. Terminal board
3. Motor cable leads
4. Stator (internal connection illustrated)
4 Installation
CodeDescription
GNYEGreen-Yellow
RDRed
GYGrey
BUBlue
YEYellow
Colors and marking of leads
Figure 5: Motor connection
3-phase connection
1. Starter equipment and mains leads (L1, L2, L3)
2. Ground (earth)
3. Functional ground
4. Control leads (T1, T2, T3, T4)
5. Thermal contact
6. Leakage detector (LD)
7. Thermistor
8. Level sensor
9. Capacitor
Color code standard
CodeDescription
BNBrown
BKBlack
WHWhite
OGOrange
GNGreen
GFK-GFV Series Installation, Operation, and Maintenance Manual9
The pump is always equipped with thermal contacts incorporated in
the stator. The pump can also have an optional water leakage sensor
(LD). The leakage sensor is mandatory if the pump has FM approval.
Figure 8: 12 leads
10GFK-GFV Series Installation, Operation, and Maintenance Manual
Sensor connection characteristics
The values have a 10 % tolerance.
SensorsValue (mA)Definition
LD and thermal contact
0Overtemperature
7.8OK
36Leakage
Page 14
WS006253B
Equipment
locked out by
Name .......................
DANGER
5 Operation
4.3 Check the impeller rotation
CAUTION: Crush Hazard
The starting jerk can be powerful. Make sure nobody is close
to the unit when it is started.
1. Start the motor.
2. Stop the motor after a few seconds.
3. Check that the impeller rotates according to this illustration.
The correct direction of impeller rotation is clockwise when you
look at the pump from above.
4. If the impeller rotates in the wrong direction, then do one of these
steps:
– If the motor has a 1-phase connection, then contact a sales or
authorized service representative.
– If the motor has a 3-phase connection, then transpose two phase
leads and do this procedure again.
5 Operation
5.1 Precautions
Before taking the unit into operation, check the following:
• All recommended safety devices are installed.
• The cable and cable entry have not been damaged.
• All debris and waste material has been removed.
NOTICE:
Never operate the pump with the discharge line blocked, or the discharge valve closed.
WARNING: Crush Hazard
Risk of automatic restart.
Distance to wet areas
WARNING: Electrical Hazard
Risk of electrical shock or burn. You must connect an additional ground- (earth-) fault protection device to the grounded (earthed) connectors if persons are likely to come into
contact with liquids that are also in contact with the pump or
pumped liquid.
CAUTION: Electrical Hazard
Risk of electrical shock or burn. The equipment manufacturer
has not evaluated this unit for use in swimming pools. If used
in connection with swimming pools then special safety regulations apply.
Noise level
NOTICE:
The sound power level of the product is lower than 70 dB(A). However,
in some installations the resulting sound pressure level may exceed 70
dB(A) at certain operating points on the performance curve. Make sure
that you understand the noise level requirements in the environment
where the product is installed. Failure to do so may result in hearing
loss or violation of local laws.
5.2 Start the pump
CAUTION: Crush Hazard
The starting jerk can be powerful. Make sure nobody is close
to the unit when it is started.
NOTICE:
Make sure that the rotation of the impeller is correct. For more information, see Check the impeller rotation.
1. Check the coolant level in the oil housing.
2. Remove the fuses or open the circuit breaker, and check that the
impeller can rotate freely.
WARNING: Crush Hazard
Never put your hand into the pump housing.
3. Conduct insulation test phase to ground. To pass, the value must
exceed 5 megaohms.
4. Start the pump.
6 Maintenance
Precautions
Before starting work, make sure that the safety instructions in the chapter Introduction and Safety on page 2 have been read and understood.
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and
lock out power before servicing to prevent unexpected startup. Failure to do so could result in death or serious injury.
WARNING: Biological Hazard
Infection risk. Rinse the unit thoroughly with clean water before working on it.
CAUTION: Crush Hazard
Make sure that the unit cannot roll or fall over and injure people or damage property.
Make sure that you follow these requirements:
• Check the explosion risk before you weld or use electrical hand
tools.
• Allow all system and pump components to cool before you handle
them.
• Make sure that the product and its components have been thoroughly cleaned.
• Make sure that the work area is well-ventilated before you open any
vent or drain valves, remove any plugs, or disassemble the unit.
• Do not open any vent or drain valves or remove any plugs while the
system is pressurized. Make sure that the pump is isolated from the
GFK-GFV Series Installation, Operation, and Maintenance Manual11
Page 15
WS001763A
WS001764A
6 Maintenance
system and that pressure is relieved before you disassemble the
pump, remove plugs, or disconnect piping.
Ground continuity verification
A ground (earth) continuity test must always be performed after service.
Maintenance guidelines
During the maintenance and before reassembly, always remember to
perform these tasks:
• Clean all parts thoroughly, particularly O-ring grooves.
• Change all O-rings, gaskets, and seal washers.
• Lubricate all springs, screws, O-rings with grease.
During the reassembly, always make sure that existing index markings
are in line.
The reassembled drive unit must always be insulation-tested and the
reassembled pump must always be test-run before normal operation.
6.1 Change the coolant
This image shows the plug that is used to change the coolant.
NOTICE:
Do not allow the weight of the pump to rest on any portion of
the impeller. The impeller must not be allowed to make contact
with the concrete floor or other hard or rough surfaces.
3. To empty the coolant with the pump in a horizontal position, do the
following:
a) Place the pump horizontally, so that the coolant plug is at the
lowest point of the pump, to ensure that the coolant will drain
completely.
It is important to empty all of the coolant.
b) Place a container under the pump.
c) Remove the coolant plug and empty the coolant.
6.1.2 Fill with coolant
Use oil as coolant. The oil should be a paraffin oil with viscosity close to
ISO VG32. Examples of suitable oil types are the following:
• Statoil MedicWay 32
• BP Enerpar M 004
• Shell Ondina 927
• Shell Ondina X430
1. Fill with coolant.
Quantity: approximately 0.4 liters (0.4 quarts)
™
™
™
™
6.1.1 Empty the coolant
CAUTION: Compressed Gas Hazard
Air inside the chamber may cause parts or liquid to be propelled with force. Be careful when opening. Allow the chamber to de-pressurize before removal of the plug.
1. To empty the coolant with the pump upright, do the following:
This method is applicable only for pumps without cooling jackets.
a) Remove the coolant plug.
b) Use a pump to remove the coolant.
2. If it is necessary to separate the drive unit from the hydraulic unit,
then do the following:
a) Carefully open the coolant plugs to relieve any built-up pressure
inside the cooling jacket.
CAUTION: Compressed Gas Hazard
Air inside the chamber may cause parts or liquid to be
propelled with force. Be careful when opening. Allow
the chamber to de-pressurize before removal of the
plug.
b) After venting any built-up pressure in the cooling jacket, re-in-
stall the coolant plugs.
c) Remove the pump housing screws.
d) Remove the drive unit from the pump housing.
12GFK-GFV Series Installation, Operation, and Maintenance Manual
2. Replace the O-ring of the coolant plug.
3. Refit the coolant plug and tighten.
Tightening torque: 10–40 Nm (7.5–29.5 ft-lbs)
6.2 Service the pump
Type of
maintenance
Initial inspection
PurposeInspection interval
A Xylem-authorized personnel
checks the pump condition. From
the results, the personnel recommends the intervals for the periodical inspection and overhaul for the
installation.
Within the first year of
operation.
Page 16
6 Maintenance
Type of
maintenance
Periodical inspection
Overhaul
NOTICE:
Shorter intervals may be required when the operating conditions are
extreme, for example with very abrasive or corrosive applications or
when the liquid temperatures exceed 40°C (104°F).
PurposeInspection interval
The inspection prevents operational
interruptions and machine breakdowns. The measures to increase
performance and pump efficiency
are decided for each application.
They can include such things as impeller trimming, wear part control
and replacement, control of zinc-anodes and control of the stator.
The overhaul lengthens the operating lifetime of the product. It includes the replacement of key components and the measures that are
taken during an inspection.
Up to every year
Applies to normal ap-
plications and operating conditions at media (liquid) temperatures <40°C (104°F).
Up to every two years
Applies to normal ap-
plications and operating conditions at media (liquid) temperatures <40°C (104°F).
6.2.1 Inspection
Service itemAction
Cable1. If the outer jacket is damaged, replace
Connection to power Check that the connections are properly se-
Electrical cabinetsCheck that they are clean and dry.
Impeller1. Check the impeller clearance.
Stator housing1. Drain all liquid, if any.
InsulationUse a megger maximum 1000 V.
Junction boxCheck that it is clean and dry.
Level regulatorsCheck the condition and functionality.
Lifting deviceCheck that the local safety regulations are
2. Check that the cables do not have any
sharp bends and are not pinched.
cured.
2. Adjust the impeller, if necessary.
2. Check the resistance of the leakage sensor.
Normal value approximately 1530 ohms,
alarm approximately 330 ohms.
1. Check that the resistance between the
ground (earth) and phase lead is more
than 5 megohms.
2. Conduct a phase-to-phase resistance
check.
followed.
2. Grease the O-rings.
Check the guard rails, covers, and other
protections.
Check that the connections are properly
tightened/connected.
Check the running values.
6.2.2 Overhaul
The basic repair kit includes O-rings, seals, and bearings.
For an overhaul, do the following in addition to the tasks listed under Inspection.
Service itemAction
Support and main
bearing
Mechanical sealReplace with new seal units.
Replace the bearings with new bearings.
6.2.3 Service in case of alarm
For information about indication values for sensors, see Sensor connec-
tion characteristics on page 10.
Alarm sourceAction
LD1. Check for liquid in the stator housing.
Thermal contactCheck the start and stop levels.
Overload protection Check that the impeller can rotate freely.
2. Drain all liquid, if any.
3. Check the mechanical seal unit, the Orings, and the cable entry, if liquid was
found.
6.3 Replace the impeller
Required tools:
• 6 hexagon bit adapter with an extension of at least 125 mm (4.92
in.)
• Impeller puller
If applicable, contact your local sales and service representative for
correct type and size.
• Rod (wood or copper) for locking the impeller in place, if applicable.
• Two crowbars, if applicable
NOTICE:
• When laying the pump on its side, do not allow the weight of the
pump to rest on any portion of the impeller. The impeller must not
be allowed to make contact with the concrete floor or other hard
and rough surfaces.
CAUTION: Cutting Hazard
Worn parts can have sharp edges. Wear protective clothing.
6.3.1 Remove the impeller
1. Remove the suction cover:
a) Place the pump horizontally.
b) Remove the suction cover screws.
c) Remove the suction cover from the pump housing.
2. Remove the impeller:
a) Remove the impeller screw.
b) Remove the impeller and the conical sleeve.
6.3.2 Install the impeller
1. Prepare the shaft:
a) Polish off any flaws with a fine emery cloth.
The end of the shaft must be clean and free from burrs.
b) Coat the inner conic, the outer cylindrical surfaces, and the
thread of the conical sleeve with a thin layer of grease.
The proper lubrication is grease for bearings, for example Exxon
Mobil Unirex N3, Mobil Mobilith SHC 220 or equivalent.
NOTICE:
Surplus grease can cause the impeller to become loose. Remove
surplus grease from conical and/or cylindrical surfaces of shafts
and/or sleeves.
2. Lubricate the threads of the impeller screw and the washer, if any.
3. Fit the impeller.
GFK-GFV Series Installation, Operation, and Maintenance Manual13
Page 17
WS007759A
WS007760A
A
WS001288A
7 Troubleshooting
Impeller type Action
Non-clogFit the conical sleeve, the washer, and the impeller
screw to the shaft.
Vortex1. Fit the conical sleeve to the shaft.
2. Fit the impeller and impeller screw to the shaft.
Figure 10: Non-clog impeller
6. Adjust the clearance.
Impeller
type
Non-clogAdjust the clearance between the lower edge of the
VortexNo adjustment or clearance check is needed. Go to
Action
impeller and the pump housing by sliding the impeller on the shaft until it touches the pump housing.
step 8 on page 14
Figure 11: Vortex
4. Fasten the impeller.
Impeller
type
Non-clog Hand-tighten the impeller screw enough to prevent it
VortexFasten the impeller by tightening the impeller screw.
5. Fit the suction cover:
a) Lubricate the suction cover screws.
b) Place the suction cover on the pump housing and fit the screws.
c) Tighten the screws in a diagonal sequence.
Tightening torque: 9 Nm (6.6 ft-lbs)
d) Check that the impeller rotates freely.
Action
from falling off.
Do not fasten the impeller until the clearance has been
adjusted in step 6 on page 14.
Tightening torque: 22 Nm (16 ft-Ibs)
Tighten it a further 1/8 turn (45°).
The clearance (A): 0.2–0.8 mm (0.008–0.032 in.)
7. If Non-clog impeller: Fasten the impeller.
a) Fasten the impeller by tightening the impeller screw.
Tightening torque: 22 Nm (16 ft-Ibs)
Tighten it a further 1/8 turn (45°).
b) Check the clearance (A) between the impeller and the pump
housing.
A: 0.2–0.8 mm (0.008–0.032 in.)
8. Check that the impeller can rotate freely.
WARNING: Crush Hazard
Beware of the pinch point hazard between the rotating
impeller and the guide pin.
7 Troubleshooting
Introduction
DANGER: Electrical Hazard
Troubleshooting a live control panel exposes personnel to
hazardous voltages. Electrical troubleshooting must be done
by a qualified electrician.
Follow these guidelines when troubleshooting:
• Disconnect and lock out the power supply except when conducting
checks that require voltage.
• Make sure that no one is near the unit when the power supply is reconnected.
• When troubleshooting electrical equipment, use the following:
14GFK-GFV Series Installation, Operation, and Maintenance Manual
Page 18
Equipment
locked out by
Name .......................
DANGER
Equipment
locked out by
Name .......................
DANGER
7 Troubleshooting
7.1 The pump does not start
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and
lock out power before servicing to prevent unexpected startup. Failure to do so could result in death or serious injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in equipment damage.
CauseRemedy
An alarm signal has
been triggered on the
control panel.
The pump does not
start automatically, but
can be started manually.
The installation is not
receiving voltage.
The impeller is stuck.Clean:
If the problem persists, then contact a sales or authorized service representative.
Always state the serial number of the product, see Product Description
on page 4.
Check that:
• The impeller rotates freely.
• The sensor indicators do not indicate an
alarm.
• The overload protection is not tripped.
Check that:
• The start level regulator is functioning.
Clean or replace if necessary.
• All connections are intact.
• The relay and contactor coils are intact.
• The control switch (Man/Auto) makes contact in both positions.
Check the control circuit and functions.
Check that:
• The main power switch is on.
• There is control voltage to the start equipment.
• The fuses are intact.
• There is voltage in all phases of the supply
line.
• All fuses have power and that they are securely fastened to the fuse holders.
• The overload protection is not tripped.
• The motor cable is not damaged.
• The impeller
• The sump in order to prevent the impeller
from clogging again.
7.2 The pump does not stop when a level
sensor is used
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and
lock out power before servicing to prevent unexpected startup. Failure to do so could result in death or serious injury.
CauseRemedy
The pump is unable to
empty the sump to the
stop level.
Check that:
• There are no leaks from the piping and/or
discharge connection.
• The impeller is not clogged.
• The non-return valve(s) are functioning
properly.
• The pump has adequate capacity. For information:
Contact a sales or authorized service representative.
There is a malfunction
in the level-sensing
equipment.
• Clean the level regulators.
• Check the functioning of the level regulators.
• Check the contactor and the control circuit.
• Replace all defective items.
The stop level is set
Raise the stop level.
too low.
If the problem persists, then contact a sales or authorized service representative.
Always state the serial number of the product, see Product Description
on page 4.
7.3 The pump starts-stops-starts in rapid
sequence
CauseRemedy
The pump starts due
to back-flow which fills
the sump to the start
level again.
The self-holding function of the contactor
malfunctions.
Check that:
• The distance between the start and stop
levels is sufficient.
• The non-return valve(s) work(s) properly.
• The length of the discharge pipe between
the pump and the first non-return valve is
sufficiently short.
Check:
• The contactor connections.
• The voltage in the control circuit in relation
to the rated voltages on the coil.
• The functioning of the stop-level regulator.
• Whether the voltage drop in the line at the
starting surge causes the contactor's selfholding malfunction.
GFK-GFV Series Installation, Operation, and Maintenance Manual15
If the problem persists, then contact a sales or authorized service representative.
Always state the serial number of the product, see Product Description
on page 4.
Page 19
Equipment
locked out by
Name .......................
DANGER
Equipment
locked out by
Name .......................
DANGER
8 Technical Reference
7.4 The pump runs but the motor protection
trips
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and
lock out power before servicing to prevent unexpected startup. Failure to do so could result in death or serious injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in equipment damage.
CauseRemedy
The motor protection
is set too low.
The impeller is difficult
to rotate by hand.
The drive unit is not
receiving full voltage
on all three phases.
The phase currents
vary, or they are too
high.
The insulation between the phases and
ground in the stator is
defective.
The density of the
pumped fluid is too
high.
There is a malfunction
in the overload protection.
If the problem persists, then contact a sales or authorized service representative.
Always state the serial number of the product, see Product Description
on page 4.
Set the motor protection according to the data plate and if applicable the cable chart.
• Clean the impeller.
• Clean out the sump.
• Check that the impeller is properly trimmed.
• Check the fuses. Replace fuses that have
tripped.
• If the fuses are intact, then notify a certified
electrician.
Contact a sales or authorized service representative.
1. Use an insulation tester. With a 1000 V DC
megger, check that the insulation between
the phases and between any phase and
ground is > 5 megaohms.
2. If the insulation is less, then do the following:
Contact a sales or authorized service representative.
Make sure that the maximum density is
1100 kg/m3 (9.2 lb/US gal)
• Change the impeller, or
• Change to a more suitable pump
• Contact a sales or authorized service representative.
Replace the overload protection.
7.5 The pump delivers too little or no water
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and
lock out power before servicing to prevent unexpected startup. Failure to do so could result in death or serious injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in equipment damage.
CauseRemedy
The impeller rotates in
the wrong direction.
• If it is a 3-phase pump, then transpose two
phase leads.
• If it is a 1-phase pump, then do the following:
Contact a sales or authorized service representative.
One or more of the
valves are set in the
wrong positions.
• Reset the valves that are set in the wrong
position.
• Replace the valves, if necessary.
• Check that all valves are correctly installed
according to media flow.
• Check that all valves open correctly.
The impeller is difficult
to rotate by hand.
• Clean the impeller.
• Clean out the sump.
• Check that the impeller is properly trimmed.
The pipes are ob-
To ensure a free flow, clean out the pipes.
structed.
The pipes and joints
Find the leaks and seal them.
leak.
There are signs of
Replace the worn parts.
wear on the impeller,
pump, and casing.
The liquid level is too
low.
• Check that the level sensor is set correctly.
• Depending on the installation type, add a
means for priming the pump, such as a
foot valve.
If the problem persists, then contact a sales or authorized service representative.
Always state the serial number of the product, see Product Description
on page 4.
8 Technical Reference
8.1 Motor data
16GFK-GFV Series Installation, Operation, and Maintenance Manual
FeatureDescription
Motor typeSquirrel-cage induction motor
Frequency50 Hz or 60 Hz
Supply1-phase or 3-phase
Starting methodDirect on-line
Page 20
FeatureDescription
Maximum starts per hour15 evenly-spaced starts per hour
Code complianceIEC 60034-1
Voltage variation without overheating
Voltage imbalance tolerance2%
Stator insulation classF (155°C [311°F])
Motor encapsulation
Motor encapsulation is in accordance with IP68.
Application limits
DataDescription
Liquid temperature
Liquid density1100 kg/m³ (9.2 lb per US gal) maximum
pH of the pumped media (liquid)
Depth of immersion
OtherFor the specific weight, current, voltage, power rat-
40°C (104°F) maximum
5.5–14 for cast iron pumps
20 m (65 ft) maximum
ings, and speed of the pump, see the data plate of
the pump.
±10%, if it does not run continuously
at full load
8 Technical Reference
GFK-GFV Series Installation, Operation, and Maintenance Manual17
Page 21
Page 22
Page 23
Page 24
Xylem |’zīləm|
1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.
We’re a global team unified in a common purpose: creating advanced technology solutions to the
world’s water challenges. Developing new technologies that will improve the way water is used,
conserved, and re-used in the future is central to our work. Our products and services move, treat,
analyze, monitor and return water to the environment, in public utility, industrial, residential and
commercial building services settings. Xylem also provides a leading portfolio of smart metering,
network technologies and advanced analytics solutions for water, electric and gas utilities. In more
than 150 countries, we have strong, long-standing relationships with customers who know us for our
powerful combination of leading product brands and applications expertise with a strong focus on
developing comprehensive, sustainable solutions.
For more information on how Xylem can help you, go to www.xylem.com
Xylem Water Solutions (Shenyang) Co. Ltd.
No.4, 11 Jia, Kaifa Road
110141 Shenyang E.T.D.Z Liaoning Province
P.R. China
Tel: +86-24-25263000
Fax:
887071_3.0_en-US_2018-05_IOM.1305_1.0_en-US_A_GFK-GFV Series
Visit our Web site for the latest version of this document
and more information
The original instruction is in English. All non-English
instructions are translations of the original instruction.