GOTHAM Ray User Manual

Multiple Layers of Light
Luminaire Type:
Catalog Number:
Buy American
General Illumination Round Downlight
OVERVIEW COMPLIMENTARY PRODUCTS
Feature Set
Bounding Ray™ optical design
Unitized optics mechanically attach the light
engine to the lower reflector for complete opti­cal alignment.
45° cutoff to source and source image
Fully serviceable and upgradeable lensed LED
light engine
70% lumen maintenance at 60,000 hours
Distribution
very narrow
0.5 S:MH
narrow
0.7 S:MH
medium
0.9 S:MH
Superior Perfomance
Nominal
Lumens
Delivered
Lumens
Wattage 31.6 41.1 47.1
Efficacy 72.5 72 72.2
2000 2500 3000
2,287 2,964 3,398
2.5 SDCM; 85 CRI typical, 90+ CRI optional
Fixtures are wet location, covered ceiling
Available with 10% dimming, 1% dimming, or
dim to dark
Batwing distribution with feathered edges
provides even illumination on horizontal and vertical surfaces
medium wide
1.0 S:MH
8"
wide
1.2 S:MH
Coordinated Apertures | Multiple Layers of Light
General Illumination Layer | EVO High Center Beam Layer | Incito
Core
Healthcare
Downlight Adjustable Open
MRI Surgical
Special
Applications
Dynamic Food Ser vice Vandal/Tamper Cle an Room Shower Steam Ro om
Suite
Wallwash
Patient Room
Lensed
Wallwash
EVO + Incito — Multiple Layers of Light
Cylinder Pinhole Bevel Hyperbolic
EVO8 page 1 of 7
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2021 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/26/21 Specifications subject to change without notice.
8"
General Illumination Round Downlight
ORDERING INFORMATION
A+ Capabl e options indi cated by this color background.
EXAMPLE: EVO8 35/30 AR MWD LSS 277 EZ1
Design2Ship Quick Ship Program: Options in green text qualify for Design2Ship — 5 business days from order entry to ship. Refer to Design2Ship Brochure for complete program details. Maximum
Order Quantity: 100 units; 50 for Chicago Plenum.
Luminaire Type:
Catalog Number:
Series Color Temperature Nominal Lumen Values Reflector & Flange Color Tr im S ty le Distribution Finish Voltage
EVO8 27/ 2700 K
30/ 3000 K 35/ 3500 K 40/ 4000 K
20 2000 lumens 25 2500 lumens 30 3000 lumens
AR Clear
PR Pewter WTR Wheat GR Gold
1
WR BR
WRAMF
White
1
Black
1
White Anti-microbial
(blank) Self-flanged VND Very Narrow
(0.5 s/mh)
ND Narrow (0.7
s/mh)
MD Medium (0.9
s/mh)
MWD Medium wide
(1.0 s/mh)
WD Wide (1.2 s/
LSS Semi-specular LD Matte-diffuse LS Specular
mh)
4
Driver
GZ10 0-10V driver dims to 10% GZ1 0-10V driver dims to 1%
EZ10 eldoLED 0-10V ECOdrive. Linear
dimming to 10% min.
EZ1 eldoLED 0-10V ECOdrive. Linear
dimming to 1% min.
EZB eldoLED 0-10V SOLOdrive.
Logarithmic dimming to <1%.
5
EDAB
EDXB
eldoLED SOLOdrive DALI. Loga­rithmic dimming to <1%.
5
eldoLED POWERdrive DMX with RDM (remote device manage­ment). Square Law dimming to <1%. Includes termination resistor.
5
ECOS2
ECOD
Lutron® Hi-Lume® 2-wire for­ward-phase driver. 120V only. Minimum dimming level 1%.
5
Lutron Ecosystem digital Hi-Lume 1% soft-on, fade to black. Maximum 2500 lumens.
Control Interface Options
6
NLT
2,6,10
NLTER
NLTAIR2 NLTAIRER2
EXA1 XPoint Wireless,
EXAB XPoint Wireless,
nLight® dimming pack controls
nLight® dimming pack controls emergency circuit
13
nLight® Air enabled
2,10,13
nLight® AIR Dimming Pack Wireless Con­trols. Controls fixtures on emergency circuit
eldoLED 0-10V ECOdrive. Linear dimming to 1%. Refer to XPoint tech sheet.
eldoLED 0-10V SOLOdrive. Logarithmic dimming
SF Single fuse. Specify 120V or 277V.
TRW TRBL EL Emergency battery pack, 10W, with integral test switch ELR Emergency battery pack, 10W, with remote test switch ELSD Emergency battery pack, 10W, with self-diagnostics, integral test switch ELRSD Emergency battery pack, 10W, with self-diagnostics, remote test switch E10WCP Emergency battery pack, 10W Constant Power, CA Title 20 compliant with integral test
E10WCPR Emergency battery pack, 10W Constant Power, CA Title 20 compliant with remote test
N80 BGTD Bodine generator transfer device. Specify 120V or 277V.
90CRI High CRI (90+)
12
CP
RRL__
to <1%. Refer to XPoint tech sheet.
7
8
White painted flange Black painted flange
switch
11
switch
nLight® Lumen Compensation
Chicago Plenum. Specify 120V or 277V.
RELOC®-ready Luminaire connectors enable a simple and consistent factory installed option across all ABL luminaire brands. Available only with RRLA, RRLB, RRLAE, and RRLC12S. Refer to RRL spec sheet on www.acuitybrands.com for RELOC product specifications. Above ceiling access required.
120 277 347
2,3
ACCESSORIES — order as separate catalog numbers (shipped separately)
SCA4
Sloped ceiling adapter. Degree of slope must be specified (5D, 10D, 15D, 20D, 25D, 30D). Ex: SCA8 10D. Refer to TECH-190.
CTA4-8 YK Ceiling thickness adapter (extends mounting frame to accommodate ceiling thickness up to 5"). Adds ~4" to fixture height. GVRT ISD BC
Vandal-resistant trim accessory. Refer to TECH-200. 0-10V wallbox dimmer. Refer to ISD-BC.
ORDERING NOTES
1. Not available with finishes.
2. Not available with GZ10, GZ1, EL or ELR options.
3. Supplied with factory installed step down transformer.
4. Refer to TECH-240 for compatible dimmers.
5. Not available with nLight
6. Must specify voltage 120V or 277V.
7. For use with different reflector finish only (i.e. AR, PR, WTR, GR options). Not available with WR (white reflector).
8. For use with different reflector finish only (i.e. AR, PR, WTR, GR options). Not available with BR (black reflector).
EVO8 page 2 of 7
®
and XPoint options.
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2021 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/26/21 Specifications subject to change without notice.
9. For dimensional changes, refer to TECH-140. Not available with 347V.
10. For use with generator supply EM power. Will require an emergency hot feed and normal hot feed.
11. Fixture begins at 80% light level. Must be specified with eldoLED drivers and NLT or NLTER.
12. Not available with ELR, EXA1 or EXAB.
13. Not available DALI or DMX drivers. Not available with CP or N80 options. Not recom­mended for metal ceiling installations.
8"
SPECIFICATIONS
Optical Assemby
Fully serviceable and upgradeable lensed LED light engine suitable for field maintenance or service from below the ceiling.
Optical design is a Bounding Ray™ design with 45° cutoff to source and source image. Top-down flash characteristic for superior glare control.
Unitized optics shall have mechanical attachment of the light engine to the lower reflector for complete optical alignment.
General Illumination Round Downlight
Electrical
The luminaire shall operate from a 50 or 60 Hz ±3 Hz AC line over a voltage ranging from 120 VAC to 277 VAC. The fluctuations of line voltage shall have no visible effect on the luminous output.
The luminaire shall have a power factor of 90% or greater at all standard operating voltages and full luminaire output.
Sound Rated A+. Driver shall be >80% efficient at full load across all input voltages.
Input wires shall be 18AWG, 300V minimum, solid copper.
Controls
Luminaire shall be equipped with interface for nLight wired or wireless network with integral power supply as per specification.
Dimming
The luminaire shall be capable of continuous dimming without perceivable stroboscopic flicker as measured by flicker index (ANSI/IES RP-16-10) over a range of 100 – 10%, 100 – 1.0% or 100 – 0.1% of rated lumen output with a smooth shut off function to step to 0%.
eldoLED LED drivers shall conform to IEEE P1789 standards. Alternatively, manufacturers must demonstrate conformance with product literature and testing which demonstrates this performance. Systems that do not meet IEEE P1789 will not be considered.
Driver is inaudible in 24dB environment, and stable when input voltage conditions fluctuate over what is typically experienced in a commercial environment.
Construction
Luminaire housing shall be constructed of 16-gauge galvanized steel and have preinstalled telescopic mounting bars with maximum 32" and minimum 15" extension and 4" vertical adjustment.
Luminaires shall be suitable for installation in ceilings up to 1½" thick. (specify ceiling thickness adapter to extend frame to accommodate ceiling thickness up to 5")
Tool-less adjustments shall be possible after installation.
The assembly and manufacturing process for the luminaire shall be designed to assure all internal components are adequately supported to withstand mechan­ical shock and vibration.
25°C ambient temperature standard (1/2" clearance on all sides from non-combustible materials in non-IC applications, unless marked spacing noted other­wise). For use in insulated ceilings, a 3" clearance on all sides from insulation is required (unless marked spacing noted otherwise).
Listings
Fixtures are CSA certified to meet US and Canadian standards: All fixtures manufactured in strict accordance with the appropriate and current requirements of the “Standards for Safety” to UL, wet location covered ceiling.
Photometrics
LEDs tested to LM-80 standards. Measured by IESNA Standard LM-79-08 in an accredited lab. Lumen output shall not decrease by more than 30% over the minimum operational life of 60,000 hours.
Color appearance from luminaire to luminaire of the same type and in all configurations, shall be consistent both initially and at 6,000 hours and operate with­in a tolerance of <2.5 MacAdam ellipse as defined by a point at the intersection of the CCT line and the black body locus line in CIE chromaticity space.
Buy American
This product is assembled in the USA and meets the Buy America(n) government procurement requirements under FAR, DFARS and DOT. Please refer to www.acuitybrands.com/buy-american for additional information.
Warranty
5-year limited warranty. Complete warranty terms located at: www.acuitybrands.com/support/customer-support/terms-and-conditions
Note:
Actual performance may differ as a result of end user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Capable Luminaire
This item is an A+ capable luminaire, which has been designed and tested to provide consistent color appearance and out-of-the-box control compatibility with simple commissioning.
• All configurations of this luminaire meet the Acuity Brands’ specification for chromatic consistency
• This luminaire is part of an A+ Certified solution for nLight
• This luminaire is part of an A+ Certified solution for nLight options marked by a shaded background*
To learn more about A+, visit www.acuitybrands.com/aplus. *See ordering tree for details
®
control networks when ordered with drivers marked by a shaded background*
®
control networks, providing advanced control functionality at the luminaire level, when selection includes driver and control
EVO8 page 3 of 7
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers, GA 30012 | P 800-705-SERV (7378) | gothamlighting.com © 2014-2021 Acuity Brands Lighting Inc. All Rights Reserved. Rev. 04/26/21 Specifications subject to change without notice.