Luminaire Type:
Catalog Number
(autopopulated):
Gotham Architectural Downlighting
International Decorative Compact Fluorescent Downlights
PDXFI
15.2cm (6”) Ice™ Blade
Horizontal Lamp, Triple-Tube
FEAT URE S ORDERING INFORMATION NOTES
OPTICAL SYSTEM
• Reflector - Self-flanged, matte-finished clear anodized reflector. Fluted vertical
upper section works in conjunction with patented Bounding Ray™ Optical
Principle design (U.S. Patent No. 5,800,050) to provide lamp before lamp
image and smooth transition from top of reflector to bottom. Minimum flange
matches reflector finish. White painted flange optional.
• Cross Baffle - Clear acrylic cross baffle with surface that provides a decorative
edge-glow appearance.
• Hinged lampdoor provided for optimal fixture efficiency and the reduction of
stray light in the plenum.
MECHANICAL
• Pre-wired galvanized steel junction box mounted to reflector provided with
removable access cover. No. 12 AWG conductors rated for 90°C.
• Three (3) swinggate brackets allow for installation from below the ceiling.
Suitable for ceiling thickness ranging from 1.59cm (5/8”) to 2.54cm (1”).
EXAMPLE: PDXFI 1/32TRT 6AR CLRF 220
ELECTRICAL SYSTEM
• Horizontally-mounted, positive-latch, thermoplastic socket.
• Thermally protected, high power factor electronic ballast (50/60Hz) mounted to
the junction box.
• Eurostyle terminal block included for power supply and ground connections
required for CE.
LISTING
• MVOLT, 120V and 277V fixtures are UL Listed, non-IC recessed mounting and
damp locations. 220V and 240V fixtures are CE certified and rated IP20.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Lamp/Wattage Trim c olo r Baffle type Voltage Ballast Options
1,2
PDXFI 1/18TRT
1/26TRT
1/32TRT
1/42TRT
6AR Clear CLRF Clear flush
CLRR Clear round
CLRA Clear angular
MVOLT
120
220
240
277
(blank) Electronic ballast
2
3
3
2
ADEZ
ADZT
4
4
ECOS Lutron EcoSystem
Advance Mark 10® electronic
dimming ballast. Minimum
dimming level 5%
Advance Mark 7® electronic
0-10V DC dimming ballast.
Minimum dimming level 3%
®
electronic
TRW White painted flange
WLP With 3500 K lamp (shipped
separately)
4
GMF
Single, slow-blow fuse
4
GLR
Single, fast-blow fuse
GSKT Foam gasketing, ships uninstalled
dimming ballast. Minimum
dimming level 5%.
5
VDB
Vossloh 0-10V dimming ballast
ORDERING NOTES
1. Multi-volt electronic ballast capable of operating on any line voltage from
120V through 277V, 50 or 60 HZ.
2. Available with UL listing only. 120-277V, 50/60Hz.
3. Available with CE listing only. 220-240V, 50/60Hz.
PDXFI-6-BLADE
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/03/13. Specifications subject to change without notice.
4. Available in 120V or 277V only.
5. Available in 220V or 240V only.

PDXFI
Overlap Trim: 19.1 (7-1/2)
detsiL LU
15.2cm (6”) Ice™ Blade
Horizontal Lamp, Triple-Tube
DIMENSIONAL DATA
All dimensions are centimeters (inches) unless otherwise noted.
36.4
(14-1/3)
32.1
(12-5/8)
19.1
)
18.1
15.9
(7-1/7
Aperture: 15.9 (6-1/4)
Ceiling Opening: 17.5 (6-7/8)
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/03/13. Specifications subject to change without notice.
PDXFI-6-BLADE
PAGE 2 OF 3

PDXFI
90˚
100
200
300
400
500
600
700
pf
15.2cm (6”) Ice™ Blade
Horizontal Lamp, Triple-Tube
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
PDXFI 1/26TRT 6AR CLRF
90˚
80˚
100
200
300
400
0˚ 10˚ 20˚ 30˚
70˚
60˚
50˚
40˚
PDXFI 1/32TRT 6AR CLRF
90˚
100
200
300
400
500
80˚
70˚
60˚
50˚
40˚
(1) CF26DT/E/IN/835, 1800 lumens per lamp, Test no. LTL11857
From 0˚ Ave Lumens
431
0
426
5
15
25
35
45
55
65
75
85
90
406
359
266
160
77
32
14
40
115
164
165
124
70
33
15
5
5
2
Zone Lumens% Lamp
318.8
0˚ - 30˚
483.9
0˚ - 40˚
678.3
0˚ - 60˚
731.3
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
1.3
732.6
*Efficiency
*40.7
17.7
26.9
37.7
40.6
0.1
pf
pc
pw
1
2
3
4
5
6
7
8
9
10
(1) CF32DT/E/IN/835, 2400 lumens per lamp, Test no. LTL11855
From 0˚ Ave Lumens
590
0
5
15
25
35
45
55
65
75
85
90
585
572
499
360
203
98
42
18
56
161
228
223
159
90
42
19
7
6
3
Zone Lumens% Lamp
444.1
0˚ - 30˚
667.0
0˚ - 40˚
915.5
0˚ - 60˚
984.3
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
1.6
985.9
*Efficiency
*41.1
18.5
27.8
38.1
41.0
0.1
pf
pc
pw
1
2
3
4
5
6
7
8
9
10
.42
.37
.33
.30
.27
.24
.22
.20
.18
.17
.43
.38
.34
.30
.27
.25
.22
.21
.19
.17
.43
.39
.35
.32
.29
.27
.25
.23
.21
.20
.43
.39
.36
.32
.30
.27
.25
.23
.22
.20
20%
20%
.42
.37
.33
.29
.26
.24
.22
.20
.18
.17
.42
.37
.33
.30
.27
.24
.22
.20
.19
.17
.41
.37
.34
.31
.28
.26
.24
.22
.21
.19
.42
.38
.34
.31
.29
.27
.25
.23
.21
.20
.40
.36
.32
.29
.26
.23
.21
.20
.18
.17
.41
.36
.32
.29
.26
.24
.22
.20
.19
.17
80% 70% 50%
50% 30% 50% 30% 50% 30%
.44
.40
.36
.32
.30
.27
.25
.23
.21
.20
80%70% 50%
50%30% 50%30% 50% 30%
.44
.40
.36
.33
.30
.28
.25
.24
.22
.20
Mount
height
8
10
12
14
16
Mount
height
8
10
12
14
16
Inital fc
at beam
center
14.2
7.7
4.8
3.3
2.4
Inital fc
at beam
center
19.5
10.5
6.5
4.5
3.2
50% beam angle
58.2˚
fc at
beam
Beam
diameter
diameter
edge
7.1
6.1
3.8
8.3
2.4
10.6
1.6
12.8
1.2
15.0
50% beam angle
58.3˚
fc at
beam
Beam
edge
9.8
6.1
5.2
8.4
3.3
10.6
2.2
12.8
1.6
15.0
10% beam angle
94.7˚
fc at
beam
Beam
diameter
diameter
edge
1.4
11.9
0.8
16.3
0.5
20.6
0.3
25.0
0.2
29.3
10% beam angle
93.4˚
fc at
beam
Beam
edge
1.9
11.7
1.0
15.9
0.7
20.2
0.4
24.4
0.3
28.7
PDXFI 1/42TRT 6AR CLRF
80˚
70˚
60˚
50˚
40˚
(1) CF42DT/E/IN/835, 3200 lumens per lamp, Test no. LTL11856
From 0˚ Ave Lumens
0
692
5
691
692
604
441
250
117
50
22
66
194
276
272
195
108
51
23
7
3
15
25
35
45
55
65
75
85
90
Zone Lumens% Lamp
0˚ - 30˚
0˚ - 40˚
0˚ - 60˚
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
8
535.8
808.2
1110.5
1193.3
1.8
1195.1
*Efficiency
16.7
25.3
34.7
37.3
0.1
*37.3
pc
pw
1
2
3
4
5
6
7
8
9
10
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
PDXFI-6-BLADE
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/03/13. Specifications subject to change without notice.
80%70% 50%
50%30% 50%30% 50%30%
.39
.39
.40
.36
.33
.30
.27
.25
.23
.21
.20
.18
.34
.31
.27
.25
.22
.20
.19
.17
.16
.36
.32
.29
.27
.25
.23
.21
.20
.18
.38
.34
.30
.27
.24
.22
.20
.19
.17
.16
.38
.34
.31
.29
.26
.24
.22
.21
.19
.18
.37
.33
.29
.26
.24
.22
.20
.18
.17
.16
Mount
height
8
10
12
14
16
Inital fc
at beam
center
22.9
12.3
7.7
5.2
3.8
50% beam angle
59.4˚
fc at
beam
Beam
6.3
8.6
10.8
13.1
15.4
edge
11.4
6.2
3.8
2.6
1.9
diameter
10% beam angle
94.1˚
fc at
beam
Beam
11.8
16.1
20.4
24.7
29.0
edge
2.3
1.2
0.8
0.5
0.4
diameter