Luminaire Type:
Catalog Number
(autopopulated):
Gotham Architectural Downlighting
International Decorative Compact Fluorescent Downlights
PDTFI
15.2cm (6”) Ice™ Turbo
Horizontal Triple-Tube Lamp
FEAT URE S ORDERING INFORMATION NOTES
OPTICAL SYSTEM
• Reflector - Self-flanged, matte-finished clear anodized reflector. Fluted vertical
upper section works in conjunction with patented Bounding Ray™ Optical
Principle design (U.S. Patent No. 5,800,050) to provide lamp before lamp
image and smooth transition from top of reflector to bottom. Minimum flange
matches reflector finish. White painted flange optional.
• Turbo Baffle - Clear acrylic, three-spoke turbo baffle with surface that provides a
decorative edge-glow appearance.
• Hinged lampdoor seals upper trim for optimal fixture efficiency and the reduction of stray light in the plenum.
MECHANICAL
• Pre-wire galvanized steel junction box mounted to reflector provided with removable access cover. No. 12 AWG conductors rated for 90°C.
• Three (3) swinggate brackets allow for installation from below the ceiling.
Suitable for ceiling thickness ranging from 1.59cm (5/8”) to 2.54cm (1”).
EXAMPLE: PDTFI 1/32TRT 6AR MVOLT
ELECTRICAL SYSTEM
• Horizontally-mounted, positive-latch, thermoplastic socket.
• Thermally protected, high power factor electronic ballast (50/60Hz) mounted to
the junction box.
• Eurostyle terminal block included for power supply and ground connections
required for CE.
LISTING
• MVOLT, 120V and 277V fixtures are UL Listed, non-IC recessed mounting and
damp locations. 220V and 240V fixtures are CE Certified and rated IP20.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Lamp/Wattage Ap e r tur e / Tr im Voltage Ballast Options
120
220
240
277
1,2
2
3
3
2
(blank) Electronic ballast
4
ADEZ
Advance Mark 10® electronic
dimming ballast. Minimum
dimming level 5%
4
ADZT
Advance Mark 7® electronic
TRW White painted flange
WLP With 3500 K lamp (shipped separately)
4
GMF
GLR
Single, slow-blow fuse
4
Single, fast-blow fuse
GSKT Foam gasketing, ships uninstalled
PDTFI 1/18TRT
1/26TRT
1/32TRT
1/42TRT
6AR
Clear MVOLT
0-10V DC dimming ballast.
Minimum dimming level 3%
ECOS Lutron EcoSystem
®
electronic
dimming ballast. Minimum
dimming level 5%.
5
VDB
Vossloh 0-10V dimming ballast
ORDERING NOTES
1. Multi-volt electronic ballast capable of operating on any line voltage from
120V through 277V, 50 or 60Hz.
2. Available with UL listing only. 120-277V, 50/60Hz.
3. Available with CE listing only. 220-240V, 50/60Hz.
PDTFI-6-ICE
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
©2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/03/13. Specifications subject to change without notice.
4. Available in 120V or 277V only.
5. Available in 220V or 240V only.

PDTFI
Overlap Trim: 19.1 (7-1/2)
15.2cm (6”) Ice™ Turbo
Horizontal Triple-Tube Lamp
DIMENSIONAL DATA
All dimensions are centimeters (inches) unless otherwise noted.
36.2
(14-1/4)
32.1
(12-5/8)
19.1
(7-1/2)
18.1
(7-1/8)
Aperture: 15.9 (6-1/4)
Ceiling Opening: 17.5 (6-7/8)
15.9
(6-1/4)
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/03/13. Specifications subject to change without notice.
PDTFI-6-ICE
PAGE 2 OF 3

PDTFI
90˚
100
200
300
400
500
600
15.2cm (6”) Ice™ Turbo
Horizontal Triple-Tube Lamp
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
PDTFI 1/26TRT 6AR
100
200
300
400
PDTFI 1/32TRT 6AR
0
0
0
0
0
0
90˚
80˚
70˚
60˚
50˚
40˚
80˚
70˚
60˚
50˚
40˚
(1) CF26DT/E/IN/835, 1800 lumens per lamp, Test no. LTL11853
From 0˚ Ave Lumens
430
0
417
360
314
234
146
76
34
14
39
102
143
144
113
68
35
15
3
3
0
5
15
25
35
45
55
65
75
85
90
Zone Lumens% Lamp
283.6
0˚ - 30˚
427.8
0˚ - 40˚
608.9
0˚ - 60˚
662.0
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
0.0
662.0
*Efficiency
*36.8
15.8
23.8
33.8
36.8
0.0
pf
pc
pw
1
2
3
4
5
6
7
8
9
10
(1) CF32DT/E/IN/835, 2400 lumens per lamp, Test no. LTL11851
From 0˚ Ave Lumens
590
0
5
15
25
35
45
55
65
75
85
90
583
509
431
317
192
100
45
18
55
143
196
196
149
90
46
20
5
4
0
Zone Lumens % Lamp
394.1
0˚ - 30˚
589.9
0˚ - 40˚
829.2
0˚ - 60˚
899.9
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
0.0
899.9
*Efficiency
*37.5
16.4
24.6
34.5
37.5
0.0
pf
pc
pw
1
2
3
4
5
6
7
8
9
10
.38
.34
.30
.26
.24
.22
.20
.18
.16
.15
.39
.34
.30
.27
.24
.22
.20
.18
.17
.16
.39
.35
.32
.29
.26
.24
.22
.20
.19
.18
.40
.36
.32
.29
.27
.25
.23
.21
.20
.18
20%
20%
.38
.33
.29
.26
.24
.21
.19
.18
.16
.15
.38
.34
.30
.27
.24
.22
.20
.18
.17
.16
.37
.34
.31
.28
.25
.23
.22
.20
.19
.17
.38
.34
.31
.29
.26
.24
.22
.21
.19
.18
.36
.32
.29
.26
.23
.21
.19
.18
.16
.15
.37
.33
.29
.26
.24
.22
.20
.18
.17
.16
80% 70% 50%
50% 30% 50% 30% 50% 30%
.40
.36
.32
.29
.27
.24
.22
.21
.19
.18
80% 70% 50%
50% 30% 50% 30% 50% 30%
.40
.36
.33
.30
.27
.25
.23
.21
.20
.18
Mount
height
8
10
12
14
16
Mount
height
8
10
12
14
16
Inital fc
at beam
center
14.2
7.6
4.8
3.3
2.4
Inital fc
at beam
center
19.5
10.5
6.5
4.5
3.2
50% beam angle
53.3˚
fc at
beam
Beam
diameter
diameter
edge
7.1
5.5
3.8
7.5
2.4
9.5
1.6
11.5
1.2
13.5
50% beam angle
53.2˚
fc at
beam
Beam
edge
9.8
5.5
5.2
7.5
3.3
9.5
2.2
11.5
1.6
13.5
10% beam angle
93.3˚
fc at
beam
Beam
diameter
diameter
edge
1.4
11.6
0.8
15.9
0.5
20.1
0.3
24.3
0.2
28.6
10% beam angle
92.6˚
fc at
beam
Beam
edge
2.0
11.5
1.0
15.7
0.7
19.9
0.4
24.1
0.3
28.2
PDTFI 1/42TRT 6AR
0˚ 10˚ 20˚ 30˚
80˚
70˚
60˚
50˚
40˚
(1) CF42DT/E/IN/835, 3200 lumens per lamp, Test no. LTL11854
From 0˚ Ave Lumens
0
673
5
668
607
520
385
233
119
54
22
63
171
237
237
180
107
55
24
4
5
0
15
25
35
45
55
65
75
85
90
ZoneLumens% Lamp
470.3
0˚ - 30˚
707.7
0˚ - 40˚
995.2
0˚ - 60˚
1079.4
0˚ - 90˚
90˚ - 180˚
0˚ - 180˚
0.0
1079.4
*Efficiency
*33.7
14.7
22.1
31.1
33.7
0.0
pf
pc
pw
1
2
3
4
5
6
7
8
9
10
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
PDTFI-6-ICE
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
©2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 09/03/13. Specifications subject to change without notice.
80%70% 50%
20%
50% 30% 50% 30%50% 30%
.36
.35
.36
.35
.34
.33
.30
.27
.24
.22
.21
.19
.18
.16
.31
.27
.24
.22
.20
.18
.17
.15
.14
.32
.29
.26
.24
.22
.20
.19
.18
.16
.30
.27
.24
.22
.20
.18
.16
.15
.14
.31
.28
.26
.23
.22
.20
.18
.17
.16
.33
.30
.26
.24
.21
.19
.18
.16
.15
.14
Mount
height
8
10
12
14
16
Inital fc
at beam
center
22.2
12.0
7.5
5.1
3.7
50% beam angle
55.2˚
fc at
beam
Beam
diameter
5.8
7.8
9.9
12.0
14.1
edge
11.1
6.0
3.7
2.5
1.8
10% beam angle
93.5˚
fc at
Beam
beam
diameter
11.7
16.0
20.2
24.5
28.7
edge
2.2
1.2
0.7
0.5
0.4