INSTALLATION INSTRUCTIONS
GRSF L/YK
MOUNTING FRAME
Upon receipt, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier. Compare the catalog descriptio n liste d on the packing slip with the label on the carton to ensure you have received the correct merchandise.
IMPORTANT SAFETY INFORMATION
For Your Protection, Read Carefully
Warning: Risk of fire. Do not install insulation within 3 inches of fixture sides or wiring compartment, nor above fixture in such a manner as to entrap heat.
1. Electric current can cause painful shock or serious injury unless handled properly. For you safety, always remember the following:
Turn off the supply power.
Ground the fixture to avoid potential
electrical shocks.
Do not handle an energized fixture or energize any fixture with wet hands, when standing on a wet or damp surface, or in water.
2. Specific safety information concerning lamps:
Match wattage of fixture and lamp exactly.
Do not remove or insert lamp when power is on.
Do not scratch glass or su bject lamp to undue pressure as either may cause lamp breakage.
Protect operating lamp from sources of moisture.
If lamp is marked it contains mercury. Follow disposal laws. See: www.lamprecycle.org
.
Label
Open
Figure 2
Figure 3
Figure 1
SAVE THESE INSTRUCTIONS
NEW INSTALLATION Lay-in panel T-bar ceiling:
1. Cut ceili ng opening slightly larger than the outside diameter on the mounting frame.
2. Positio n mountin g fram e thr oug h ope ning i n ceil ing. Release clamping latch arms and adjust channel bars to the correct spacing between T-bar as shown in Figure 2.Secure channel bars to T-bar by means of wire ties, screws or by bending ends onto T-bar as shown in Figure 3.
3. Once mounting frame has been secured in structure, adjust the mounting frame vertically to align the bottom edge to either flush or slightly above (1/8” max) the ceiling line as shown in Figure 4. Secure mounting frame into position by closing the clamping latch arm.
4. If additional security is required, a No. 8 sheet metal screw, wire tie or wire (not supplied) may be used to tie the latch arm to the mounting fr ame as
Clamping Latch Arm
Closed
shown in Figure 2.
5. Remo ve knockouts on junction box to feed power supply to fixture as shown in Figure 5. Supply wire must meet applicable electrical codes and be rated for a minimum of 90°C. Junction box is thru-wire rated for 8-No. 12 AWG conductors (4in-4out)
6. Complete necessary wire connections. Snap the door onto the junction box as shown in Figure 5. If the ballast is desired on the opposite side of the junction box, pass the entire door and ballast assembly through the junction box and snap into place.
7. Drop socket housing assembly through mounting frame aperture.
Non-accessible ceiling: (plaster, drywall, etc) For wallwash applications, refer to label located
on mounting frame for proper orientation with respect to the wall, to be illuminated as shown in Figure 1.
1. Release clamping latch arms and adjust channel bars to the correct spacing between joists as shown in Figure 2.
2. Mounting Channel Bars
Flexible Wiring Method
Bend ends of channel bars 90 with vertical adjustment at its lowest point on the mounting frame. Make sure bottom of the flange is flush with the bottom of the joists. Secure mounting frame into position by closing the clamping latch arm. Channel bars will accommodate up to 24” O.C. joists.
0
and mount to joists
CJ520404 Rev. C
8/10 1 of 2
©1994, 2010 Acuity Brands Lighting, Inc.
All Rights Reserved.
Page 2
INSTALLATION INSTRUCTIONS - GRSF L/YK MOUNTING FRAME
Non-Flexible Wiring Method
If non-flexible wiring method is used, follow procedure for flexible wiring method. Then lower mounting frame equal to the thickness of the finished ceiling or slightly above as shown in Figure 4.
3. Remove knockouts on junction box to feed power supply to fixture as shown in Figure 5. Supply wire must meet applicable electrical codes and be rated for a minimum for 90°C. Junction box is thru-wire rated for 8-No. 12 AWG conductors (4in-4out).
4. Compl ete necessary splices. Snap the door onto the junction box as shown in Figure 5. If the ballast is desired on the opposite sid e of the junction box, pass the entire door and ballast assembly through the junction box and snap into place.
5. Drop socket housing assembly through mounting frame opening.
Ceiling
Mounting
Frame
Figure 4
Figure 5
Reflector
Junction Box
CJ520404 Rev. C
8/10 2 of 2