Gotham EVO-SQ User Manual

CJ5201108 REV. A
7/12 1 OF 2
@2012 Acuity Brands Lighting, Inc.
All Rights Reserved
INSTALLATION INSTRUCTIONS
Figure 1
Figure 2
Figure 3
Installation:
1) Place (2) short hanger bars together so that the formed tabs slip into the slots to form one long rigid hanger bar. Aligning the ”V” cutouts in the hanger bar will set the spacing for a 24” ceiling. (See Figure 1.)
2.) Assemble the hanger bars into the adjustable mounting brackets by sliding the mated long rigid hanger bar through the tall vertical leg of the C-shaped cutout in the bracket and secure with the supplied hardware, the wing nut facing away from the fixture for adjustment. (See figure 3)
3.) Adjust the hanger bars as needed and tighten the wing nuts to secure the spacing. (See Figure 1.)
4.) Locate the T-bar slots near the ends of the bar hangers, bend the tabs out at 45 degree angle from the bar hanger at each end. Snap the bar hangers over the ceiling T-bars for a secure fit. (See Figure 2.)
5.) Repeat this assembly for the opposite side of the fixture.
Wiring:
1.) Remove the snap-on junction box captive door.
2.) Pry out the desired knockout with a flat blade screwdriver for hard wire access. (Figure 5)
3.) Driver Black wire connects to Line Voltage. Driver White wire connects to the Neutral wire. The Ground wire connects to the Bare Copper wire connected to the junction box. Bundle all wire into junction box.
4.) Close the snap-on junction box captive door.
Wood Joist Installation:
1) Bend (4) bar hangers per fixture at right angles at the row of (3) holes 2 inches from one end of the bar hangers. (See Figure 3.)
2) Insert bar hangers into adjustable mounting brackets as shown. (See Figure 3)
3) Adjust the hanger bars as needed and tighten the wing nuts to secure for 16” to 24” center-to-center joist spacing.
4) Use fasteners, supplied by others, to secure the fixture to the wood joists in at least (4) places.
CJ5201108 REV. A
7/12 1 OF 2
@2012 Acuity Brands Lighting, Inc.
All Rights Reserved
INSTALLATION INSTRUCTIONS
Figure 4
Figure 5
Figure 6
Sight
Notches
Remove knockouts as needed
Speed Nuts
xLay-in panel T-bar ceiling:
1. Cut ceiling opening slightly larger than the outside opening of the mounting frame.
2. Position mounting frame through opening in ceiling.
3. Once mounting frame has been secured in structure, adjust the mounting frame vertically to align the bottom edge to either flush or slightly above (1/8" max) the ceiling line (see Figure 3). The notch located in the draw-down flange of the housing can be used to assist with alignment of multiple fixtures (see Figure 4).
4. If additional security is required, a No. 8 sheet metal screw, wire tie or wire (not supplied) may be used to tie the latch arm to the mounting frame.
5. Remove knockouts on junction box to feed power supply to fixture (see Figure 5). Supply wire must meet applicable electrical codes and be rated for a minimum of 90°C. Junction box is thru-wire rated for 8-No. 12 AWG conductors (4 in-4 out).
6. Complete necessary wire connections. Snap the door onto the junction box.
7. To adjust housing alignment after installation, see “Post Installation Adjustment.”
POST INSTALLATION HOUSING ALIGNMENT
In the event that the trim is in need of alignment after installation, adjustments can be made to the housing.
1. Remove trim by gripping edge of flange and pulling it out of housing.
2. To adjust housing for trim alignment, reach through aperture and loosen two speed nuts (see Figure 6). Adjust housing as required and retighten nuts.
3. Reinstall trim. If needed, refer to trim installation instructions.
Loading...