Luminaire Type:
Catalog Number
(autopopulated):
Gotham Architectural Downlighting
International Compact Fluorescent Downlights/Wallwash
AFI/AFWI
15.2cm (6”) Open/Wallwash
Horizontal DTT or TRT Lamp
FEAT URES ORDERING INFORMATION NOTES
OPTICAL SYSTEM
• Reflector: Self-flanged, semi-specular or matte-diffuse reflector. Fluted vertical
upper section works in conjunction with Patented Bounding Ray™ Optical
Principle design (U.S. Patent No. 5,800,050) to provide lamp before lamp
image and smooth transition from top of reflector to bottom. Minimum flange
matches reflector finish.
• Baffle/cone: Semi-specular clear upper reflector. Microgroove baffle with white
painted flange or specular black cone with flange that matches cone finish.
• Hinged lampdoor provided for optimal fixture efficiency and the reduction of
stray light in the plenum.
• Wallwash: Highly reflective outer kicker reflector provides smooth, uniform
illumination floor to ceiling, edge to edge. Inner cone is contoured to eliminate
room side flash. For optimal uniformity, the recommended luminaire spacing is
0.9m (3’) from the wall and 0.9m (3’)centers.
MECHANICAL SYSTEM
• Pre-wired galvanized steel junction box mounted to reflector is provided with
removable access cover. Knockouts provided for power supply feed and conduit
EXAMPLE: AFI 1/26TRT 6AR 220
runs. No. 12 AWG conductors, rated for 90°C.
• Three (3) swinggate brackets allow for installation from below the ceiling.
Suitable for ceiling thickness ranging from 1.59cm (5/8”) to 2.54cm (1”).
ELECTRICAL SYSTEM
• Horizontally-mounted, positive-latch, thermoplastic socket.
• Thermally protected, high power factor electronic ballast (50/60Hz) mounted to
the junction box.
• Eurostyle terminal block included for power supply and ground connections
required for CE.
LISTING
• MVOLT, 120V and 277V fixtures are UL Listed, Non-IC recessed mounting and
damp locations. 220V and 240V fixtures are CE certified and rated IP20.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Wattage/Lamp Aperture/Trim color Finish Voltage Ballast Options
AFI
AFWI
1/13DTT
1/18DTT
1/26DTT
1/13TRT
1/18TRT
1/26TRT
1/32TRT
1/42TRT
6AR Clear
6PR Pewter
6WTR Wheat
1
6CB
Cross baffle
1,2
6BC
Black cone
1,2
6WR
White painted
(blank) Semi-specular
LD Matte-diffuse
MVOLT
120
220
240
277
3,5
(blank) Electronic ballast
5
ECOS Lutron
4
4
5
ADEZ
ADZT
VDB
6
6
7
®
EcoSystem® electronic
dimming ballast. Minimum
dimming level 5%.
Advance Mark 10® electronic
dimming ballast. Minimum
dimming level 5%
Advance Mark 7® electronic
0-10V DC dimming ballast.
Minimum dimming level 3%
Vossloh 0-10V dimming ballast
TRW White painted flange
TRBL Black painted flange
WLP With 3500 K lamp
(shipped separately)
GMF Single, slow-blow fuse
GLR Single, fast-blow fuse
GSKT Foam gasketing, ships
uninstalled
ORDERING NOTES
1. AFI only.
2. Not available with finishes.
3. Multi-volt electronic ballast capable of operating on any line voltage from
120V through 277V, 50 or 60 Hz.
4. Available with CE listing only. 220-240V, 50/ 60 Hz.
AFI-AFWI-6
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 06/26/13. Specifications subject to change without notice.
5. Available with UL listing only. 120-277V, 50/60Hz.
6. Available with 120V or 277V only.
7. Available with 220V or 240V only.

AFI/AFWI
15.2cm (6”) Open/Wallwash
Horizontal DTT or TRT Lamp
DIMENSIONAL DATA
All dimensions are inches (centimeters) unless otherwise noted.
detsiL LU
36.3
(14-5/16)
deifitreC EC
32.1
(12-5/8)
19.1
(7-1/2)
15.9
(6-1/4)
Aperture: 15.9 (6-1/4)
Ceiling Opening: 17.5 (6-7/8)
Overlap Trim:19.1 (7-1/2)
18
(7-1/8)
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 06/26/13. Specifications subject to change without notice.
AFI-AFWI-6
PAGE 2 OF 3

AFI/AFWI
15.2cm (6”) Open/Wallwash
Horizontal DTT or TRT Lamp
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
AFI 1/18TRT 6AR
AFI 1/26TRT 6AR
From 0° cp. Lumens
0° 423
5° 522 41
15° 579 123
25° 543 187
35° 328 175
45° 263 150
55° 12 17
65° 11
75° 11
85° 00
90° 0
From 0° cp. Lumens
(1) CF18DT/E/IN/835, 1200 LUMENS PER LAMP, 1.3 S/MH, TEST NO. LTL9404
Zone Lumens %lamp
0°-30° 351.8 29.3
0°-40° 526.7 43.9
0°-60° 693.5 57.8
0°-90° 695.4 58.0
90°-180° 0.0 0.0
0°-180° 695.4 58.0*
*Efficiency
(1) CF26DT/E/IN/835, 1800 LUMENS PER LAMP, 1.2 S/MH, TEST NO. LTL9391
Zone Lumens%lamp
0° 713
5° 792 72
15° 850 206
25° 765 307
35° 493 282
45° 383 232
55° 15 27
65° 12
75° 01
85° 00
90° 0
0°-30° 584.2 32.5
0°-40° 866.2 48.1
0°-60° 1125.1 62.5
0°-90° 1127.4 62.6
90°-180° 0.0 0.0
0°-180° 1127.4 62.6*
*Efficiency
ρ c 80% 70%50%
ρw50% 30% 50% 30%50% 30%
1636262616059
2585657555553
3535053495148
4494548454744
5454144414340
6423841374037
7383438343734
8363235313531
9332933293229
10 31 27 31 27 30 27
ρ c 80% 70%50%
ρw50% 30%50% 30%50% 30%
1696767666564
2636062596058
3585457545552
4534952495148
5494548444744
6454145414440
7423741374037
8393438343834
9363236323531
10 34 30 33 29 33 29
50
Initial fc fc at fc at
Mount at beam Beam beam Beam beam
height center diameter edge diameter edge
8' 14.0 6.5 7.0 11.8 1.4
10'7.5 8.83.8 16.1 0.8
12'4.7 11.2 2.3 20.4 0.5
14'3.2 13.5 1.6 24.7 0.3
16'2.3 15.9 1.2 29.0 0.2
Initial fc fc at fc at
Mount at beam Beam beam Beam beam
height center diameter edge diameter edge
8' 23.6 6.3 11.8 11.8 2.4
10'12.78.6 6.3 16.0 1.3
12'7.9 11.0 4.0 20.3 0.8
14'5.4 13.3 2.7 24.6 0.5
16'3.9 15.6 2.0 28.8 0.4
beam angle 60.9° beam angle 94.1°
50
beam angle 59.9° beam angle 93.8°
0%
0%
AFI 1/32TRT 6AR
From 0° cp. Lumens
AFI 1/42TRT 6AR
From 0° cp. Lumens
15° 1136 323
25° 1043 487
35° 774 473
45° 622 374
55° 26 41
65° 22
75° 11
85° 00
90° 0
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
AFI-AFWI-6
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 06/26/13. Specifications subject to change without notice.
(1) CF32DT/E/IN/835, 2400 LUMENS PER LAMP, 1.3 S/MH, TEST NO. LTL9390
Zone Lumens %lamp
0° 784
5° 86879
15° 914 230
25° 890 354
35° 587 332
45° 473 273
55° 22 31
65° 23
75° 12
85° 11
90° 0
(1) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 1.3 S/MH, TEST NO. LTL9521
0° 1058
5° 1135 107
0°-30° 663.0 27.6
0°-40° 995.2 41.5
0°-60° 1299.6 54.2
0°-90° 1304.8 54.4
90°-180°0.0 0.0
0°-180° 1304.8 54.4*
*Efficiency
Zone Lumens %lamp
0°-30° 916.8 28.6
0°-40° 1390.1 43.4
0°-60° 1805.1 56.4
0°-90° 1808.4 56.5
90°-180° 0.0 0.0
0°-180° 1808.4 56.5*
*Efficiency
ρ
ρ c 80% 70% 50%
ρw 50% 30%50% 30%50% 30%
1605858575655
2555254515250
3504749464845
4464345424441
5423942384138
6393539353835
7363236323532
8333033293229
9312731273027
10 29 25 29 25 28 25
ρ c 80% 70%50%
ρw50% 30%50% 30%50% 30%
1626061595857
2575456535452
3524951485047
4484447444643
5444043404239
6413740363936
7383437333633
8353134313430
9322832283128
10 30 26 30 26 29 26
50
Initial fc fc at fc at
Mount at beam Beam beam Beam beam
height center diameter edge diameter edge
8' 25.9 6.6 13.0 11.
10' 13.99.0 7.0 16.1 1.4
12' 8.711.4 4.320.4 0.9
14' 5.913.8 3.024.7 0.6
16' 4.316.2 2.229.0 0.4
Initial fc fc at fc at
Mount at beam Beam beam Beam beam
height center diameter edge diameter edge
8' 35.0 6.717.511.
10' 18.8 9.1 9.416.
12' 11.7 11.55.9 20.
14'8.0 14.0 4.024.7 0.8
16'5.8 16.4 2.929.0 0.6
beam angle 62.0° beam angle 94.1°
50
beam angle 62.5° beam angle 94.2°
0%
0%
.5
.9
.2
.6