INSTALLATION INSTRUCTIONS
AF/AFW Trim
Upon receipt, thoroughly inspect for any
freight damage which should be brought
to the attention of the delivery carrier.
Compare the catalog descriptio n liste d on
the packing slip with the label on the
carton to ensure you have received the
correct merchandise.
SAVE THESE INSTRUCTIONS
New Installation for AF/AFW Reflector
1. If emergency lighting pilot light/test sw itch is ins talled in reflector, make plug connections (see F igure
1) and tuck wires into socket housing. Attach socket housing to top of reflector by aligning/inserting
socket housing into raised tabs on top of reflector. Align screw on socket housing with keyhole slot in
top of reflector and push socket housing forward (see Figure 2). Secure socket housing and reflector
together by tightening the screw.
2. Insert reflector through the ceil ing opening ma king sure to tilt and rock ref lector (see Fi gure 3). A lign
reflector attachment screw (see Figure 4) with keyhole slot in reflector assembly. Tighten the
attachment screw until the reflector is flush against the ceil ing. NOTE - For best results, position
socket housing opposite the ballast. For AFW trim, make sure that the wallwash opening in the
reflector is oriented with respect to the wall to be illuminated(see Figure 5).
3. Install appropriate lamp by inserting tip of lamp through the opening opposite the socket housing,
aligning base of lamp with socket and snapping l amp into socket. Refer to label located inside socket
cup for proper lamp type and wattage.
4. To remove the reflector: remove lam p(s), loos en reflector attach ment screw and disengage reflector.
Tilt and rock reflector until it comes through the ceiling opening, loosen screw and remove socket
housing from reflector.
IMPORTANT SAFETY INFORMATION
For Your Protection, Read Carefully
Warning: Risk of fire. Do not install
insulation within 3 inches of fixture
sides or wiring compartment, nor above
fixture in such a manner as to entrap
heat.
1. Electric current can cause painful
shock or serious injury unless handled
properly. For you safety, always
remember the following:
• Turn off the supply power.
• Ground the fixture to avoid potential
electrical shocks.
• Do not handle an energized fixture or
energize any fixture with wet hands,
when standing on a wet or damp surface,
or in water
2. Specific safety information
concerning lamps:
• Match wattage of fixture and lamp
exactly.
• Do not remove or insert lamp when
power is on.
• Do not scratch glass or subject lamp to
undue pressure as either may cause
lamp breakage.
• Protect operating lamp from sources of
moisture.
• If lamp is marked it contains
mercury. Follow disposal laws. See:
www.lamprecycle.org
.
Socket
Housing
Socket
Housing
Raised Tabs
Socket
Housing
Ballast
Plug
Connection
Pilot light/
test switch
Figure 1 Figure 2
Reflector
Figure 3
Wallwash
Yoke shown in
upright position
Reflector
Attachment Screw
Opening
Wall
Light
Figure 4 Figure 5
TROUBLESHOOTING CHART
Check for any visible damage to the lamp or frame-in module. If they seem in good condition, locate the problem in the
following list of possible causes and corrective actions.
Corrective ActionPossible CauseSymptom
LAMP FAILS TO
LIGHT
AFTER LIGHTING
LAMP CYCLES ON
AND OFF
•Circuit feeding the fixture not energized.
•Wiring error in circuit or module
connection.
•Faulty lamp.
•Line or ballast output.
•Faulty ballast.
•Ambient temperature too low.
•Faulty lampLAMP GOES OUT
•Insulation too close to fixture.
•Lamp wattage too high.
•Ballast output voltage low.
•Check circuit breaker or fuse to ensure that circuit is energized.
•Examine fixture splice box to ensure that connections are correct.
•Remove the faulty lamp and substitute another lamp. Preferably
one that is known to light. If lamp lights, replace the original with a
new one.
•Check line voltage at fixture. Check open circuit voltage.
•Check circuit continuity.
•Check ballast rating against existing environmental conditions.
•Occasionally a lamp will exhibit this symptom rather than simply
failing to light. Substitute a new lamp.
•Remove installation from around module (at least 3”).
•Install lamp wattage specified in housing.
•Check line voltage at the fixture. Check open circuit voltage.