Gotham 8 DP SpecSheet

Luminaire Type: Catalog Number (autopopulated):
Gotham Architectural Downlighting Line Voltage Incandescent
8” DP
PAR Directional
Par Lamp
FEAT URES ORDERING INFORMATION
OPTICAL SYSTEM
• Self-flanged, semi-specular clear, matte-diffuse or highly specular cone designed to minimize back flash. Contour cut reduces visibility of inner housing.
• Center Beam optical system centers the lamp relative to the true aperture, optimizing lamp efficiency.
• Tool-less 0°- 40° vertical and 355° horizontal lamp adjustments made with the trim assembly removed for simple focusing. Lockable adjustment mechanisms maintain focus during re-lamping and are visible from below the ceiling with trim assembly removed.
• Designed to allow hot aiming.
• Trim assembly retained by self-aligning torsion springs.
• Internal housing components painted black.
MECHANICAL SYSTEM
• Black painted housing features tool-less top access and accommodates a maximum 1-1/2” ceiling thickness.
• Re-lamp capability from above or below ceiling.
• 16-gauge galvanized steel mounting bars with continuous 4” vertical adjust-
EXAMPLE: DP PAR16-30S 8ACT30 LD TRW
ment are shipped pre-installed. Previous installation adjustment possible without the use of tools above or below ceiling.
• Secondary housing adjustment system for precise, final flange to ceiling alignment.
• Galvanized steel junction box with hinged access covers and spring latch. Three combination 1/2” - 3/4” and one 1/2” knockout for straight-through conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors rated for 90°C.
ELECTRICAL SYSTEM
• Tool-less access door provides access to junction box through the aperture.
• Medium base porcelain socket with nickel-plated screw shell.
• Thermally-activated insulation detector is replaceable without the use of tools.
LISTING
• Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and damp locations. Listed and labeled to comply with Canadian standards.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Wattage/Lamp Aperture/Trim color Typ e Finish
DP PAR16-30S PAR16, PAR20 and PAR30S (short-
neck,75W max.) compatibility
PAR30L-38 PAR30L (75W max.) and PAR38 (250W
max.) compatibility
PAR46 PAR46 (200W max.) compatibility PAR56 PAR56 (300W max.) compatibility
8AC
Clear
8BC1Black 8PC Pewter 8WTC Wheat 8GC Gold
1
8WC
White painted
1
8MB
Black baffle
1
8WB
White baffle
Cut for angles 25°-40°
T30 T20 Cut for angles 15°-25° T00 Cut for angles 0°-15°
(blank) Semi-specular
LD Matte-diffuse LS Specular
Options
2
SDT SDT347
TRW
277V stepdown transformer (277V to 120V). Add 4” to width of fixture
2
347V stepdown transformer (347V to 120V). Add 4” to width of fixture (75W max) White painted flange (Standard with WC, MB, and WB.)
2
Single fuse
SF RRL3RELOC®-ready luminaire. Provides compatibility with Lithonia RELOC system. Access
above ceiling required.
CP
Chicago plenum
TRBL Black painted flange
ACCESSORIES order as separate catalog numbers (shipped separately)
LFH701 Locking Filter Holder for use with PAR16-30S. LTWFH500 DBL Filter Holder for use with PAR30S & PAR30L F700 LFH702 Locking Filter Holder for use with PAR30L-38 LTWFH700 DBL Filter Holder for use with PAR38 F800 LFH703 Locking Filter Holder for use with PAR46 and PAR56 F400 LTWFH400 DBL Filter Holder for use with PAR20 F500
DP-8-PAR-DIRECTIONAL
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 08/12/13. Specifications subject to change without notice.
4
4
Lens for use with 400 series filter holder GFC800 Gotham Filter Clips for use with PAR46 Lens for use with 500 series filter holder and PAR56
4
Lens for use with 700 series filter holder
4
Lens for use with 800 series filter holder
8” DP
Overlap Trim:
PAR Directional
Par Lamp
DIMENSIONAL DATA NOTES
All dimensions are inches (centimeters) unless otherwise noted.
17-3/8
(44.1)
12-1/8 (30.8) 10-1/2 (26.7)*
19-3/4
(50.2)
*Housing height for PAR16-30S.
Aperture:
7-7/8 (20.1)
Ceiling Opening: 8-7/8 (22.5)
9-1/4 (23.5)
ORDERING NOTES
1. Not available with finishes.
2. Single fuse standard when SDT or SDT347 options are ordered.
3. For compatible RELOC systems, refer to TECH-110.
4. Refer to TECH-120 for lens color availability.
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 08/12/13. Specifications subject to change without notice.
DP-8-PAR-DIRECTIONAL
PAGE 2 OF 3