Luminaire Type:
Catalog Number
(autopopulated):
Gotham Architectural Downlighting
Compact Fluorescent Downlights
8” AFZW
Cross Baffle Trim
Low Profile
Double Twin-Tube
FEAT URES ORDERING INFORMATION NOTES
OPTICAL SYSTEM
• Specular clear upper reflector.
• Self-flanged semi-specular or matte-diffuse cross baffle reflector. Asymmetric
baffle provides precise shielding and brightness control on room side and highangle vertical illumination on the wall. Minimum flange matches cone finish.
• Optical system retained by self-align, torsion support springs.
MECHANICAL SYSTEM
• 16-gauge galvanized steel construction; maximum 7/8” ceiling thickness.
• Telescopic mounting bars maximum of 32” and minimum of 15”, preinstalled,
4” vertical adjustment.
• Toolless post-installation adjustments.
• Junction box capacity: 8 (4 in, 4 out) 12AWG rated for 90°C.
ELECTRICAL SYSTEM
• Die-cast aluminum socket housing. Ventilated top for effective heat dissipation.
• Horizontally mounted, four-pin, positive latch, thermoplastic sockets.
• Class P, thermally protected, high-power-factor electronic ballast mounted to the
junction box.
• SIMPLY5™ technology available.
EXAMPLE: AFZW 2/26DTT 84A MVOLT
LISTING
• Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and
WARRANTY
• 1-year limited warranty. Complete warranty terms located at
Series Wattage/Lamp Aperture/Trim color Finish Voltage Ballast
AFZW 2/13DTT
2/18DTT
2/26DTT
84A Clear
84P Pewter
84WT Wheat
1
84W
White
(blank) Semi-
specular
LD Matte-
diffuse
MVOLT
120
277
347
2
(blank) Electronic ballast
ECOS
ADEZ
ADZT
damp locations. Listed and labeled to comply with Canadian standards.
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
3
2, 4
Lutron® EcoSystem® electronic dimming ballast. Minimum dimming level 5%
4, 5
Advance Mark 10® electronic dimming ballast. Minimum dimming level 5%
2
Advance Mark 7® electronic dimming ballast. Minimum dimming level 5%
painted
Options
WLP With 3500 K lamp (shipped separately)
TRW White painted flange
TRBL Black painted flange
5, 6
ELR
ELRHL
GMF
GLR
Emergency battery pack with remote test switch
5, 6
High-lumen-output emergency battery pack with remote test switch
5
Single, slow-blow fuse
5
Single, fast-blow fuse
GSKT Foam gasketing
RRL
BDP
NEPP Interface for Sensor Switch
HW Hardwire for S5 system; replaces RELOC
WRL9Wattage restriction label
TWS Twist lock socket
ORDERING NOTES
1. Not available with finishes.
2. Multi-volt electronic ballast capable of operating on any voltage from 120V through
277V, 50 or 60 Hz.
3. For additional ballast types, refer to TECH-250.
4. Not available with 13DTT or 347V.
5. Available in 120V or 277V only.
AFZW-8-XBAFFLE
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/14. Specifications subject to change without notice.
7
RELOC®-ready luminaire. Provides compatibility with Lithonia Reloc system. Access
above ceiling required.
8
Ballast disconnect plug
TN-623-01.
6. For dimensional changes, refer to TECH-140.
7. For compatible RELOC systems, refer to TECH-110.
8. Meets codes that require in-fixture disconnect.
9. Must specify wattage: Ex.: WRL18
®
nLight® network with integral power supply. Refer to
®

8” AFZW
Overlap trim:9-1/4 (23.5)
Cross Baffle Trim
Low Profile, Double Twin-Tube
DIMENSIONAL DATA
All dimensions are inches (centimeters) unless otherwise noted.
4-1/2
15-7/8
Aperture: 8 (20.3)
Ceiling opening: 8-5/8 (21.9)
17-7/8 (45.4)
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/14. Specifications subject to change without notice.
AFZW-8-XBAFFLE
PAGE 2 OF 3

8” AFZW
Wallwash Illuminance Study (fc)
Cross Baffle Trim
Low Profile, Double Twin-Tube
PHOTOMETRY
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.
Fixture/Lamp Candlepower Data Footcandle values
2/26DTT 84A
PL-C 26W/27K lamps
1157
1121
1106
1042
680
404
185
92
45
Plane Angle
1157
1157
1157
1157
1157
1129
1143
1156
1069
1056
842
861
525
456
222
159
48
8
0
4
0
0
0
1189
1093
1170
866
901
498
528
150
35
177
9
0
0
0
0
21
0
0
0
0
1157
1217
1245
1247
1335
1114
1170
525
559
125
102
1
0
0
0
0
0
0
0
0
0
0
0
0
0
total rated lumens
No. 2193122101
Wall 22.5 45 67.590112.5135 157.5
0
1157
5
1126
15
1104
25
1023
35
734
45
516
55
255
65
129
Vertical Angle
75
63
85
26
90
0
0
1
157
2
0
135
ft. from ceiling33.54 33.5 4
0
1
112
2
0
90
Illuminance on wall from 6 luminaires
Luminaire
mounted 3 ft.
from wall
3 ft. between
luminaires
1
2
3
4
5
6
7
8
9
10
11
9
15
12
22
19
22
22
21
21
19
19
16
17
13
14
11
11
9
8
22
0
45
0
1
67
2
Luminaire
mounted 4 ft.
from wall
4 ft. between
luminaires
6
9
3
15
6
22
11
22
13
21
13
19
12
16
12
13
10
11
9
8
9
9
8
8
7
0
1
2
2
3
5
6
8
11
11
13
12
13
12
12
12
12
11
10
10
9
8
8
7
7
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory condition.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
AFZW-8-XBAFFLE
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/14. Specifications subject to change without notice.