Luminaire Type:
Catalog Number
(autopopulated):
Gotham Architectural Downlighting
Compact Fluorescent Downlights
8” AFWLP
Low Profile Wallwash
Horizontal DTT or TRT lamp
FEAT URES ORDERING INFORMATION
OPTICAL SYSTEM
• Self-flanged semi-specular or matte-diffuse reflector. Patented Bounding
Ray™ Optical Principle design (U.S. Patent No. 5,800,050). Minimum flange
matches reflector finish.
• Highly reflective outer kicker reflector provides smooth, uniform illumination
floor to ceiling, edge to edge. Inner cone is contoured to eliminate room-side
flash. For optimal uniformity, the recommended luminaire spacing is 3’ from the
wall and 3’ centers.
• Hinged lampdoor seals upper trim for optimal fixture efficiency and the reduction of stray light in the plenum.
MECHANICAL SYSTEM
• 16-gauge galvanized steel construction; maximum 1-1/4” ceiling thickness.
• Telescopic mounting bars maximum of 32” and minimum of 15”, preinstalled,
4” vertical adjustment.
• Toolless post-installation adjustments.
• Junction box capacity: 8 (4 in, 4 out) 12AWG rated for 90°C.
EXAMPLE: AFWLP 1/26TRT 8AR MVOLT
ELECTRICAL SYSTEM
• Horizontally mounted, positive-latch, thermoplastic socket.
• Class P, thermally protected, high-power-factor electronic ballast mounted to the
junction box.
• SIMPLY5™ technology available.
LISTING
• Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and
damp locations. Listed and labeled to comply with Canadian standards.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Wattage/Lamp Aperture/Trim color Finish Voltage Ballast
AFWLP 1/18DTT
1/26DTT
2/18DTT
2/26DTT
8AR Clear
8PR Pewter
8WTR Wheat
1
8WR
White painted
(blank) Semi-specular
LD Matte-diffuse
MVOLT
120
277
347
2
(blank) Electronic ballast
ECOS
ADEZ
1/18TRT
1/26TRT
ADZT
1/32TRT
1/42TRT
S5
2/18TRT
2/26TRT
2/32TRT
2/42TRT
3
2, 4
Lutron® EcoSystem® electronic dimming ballast. Minimum
dimming level 5%
4
Advance Mark 10® electronic dimming ballast. Minimum
dimming level 5%
2
Advance Mark 7® electronic dimming ballast. Minimum
dimming level 5%
5
SIMPLY5™ system ballast. Minimum dimming level 15%
Options
4, 6
ELR
ELRHL
GMF
GLR
Emergency battery pack with remote test switch
4, 6
High-lumen-output emergency battery pack with remote test switch
4
Single, slow-blow fuse
4
Single, fast-blow fuse
TRW White painted flange
TRBL Black painted flange
DS Dual switching
7
CP
Chicago plenum
WLP With 3500 K lamp (shipped separately)
AFWLP-8
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 06/11/13. Specifications subject to change without notice.
HW Hardwire for S5 system; replaces RELOC
®
NEPP Interface for Sensor Switch® nLight® network with integral power supply. Refer to
TN-632-01.
8
WRL
Wattage restriction label

8” AFWLP
Low Profile Wallwash
Horizontal DTT or TRT lamp
DIMENSIONAL DATA NOTES
All dimensions are inches (centimeters) unless otherwise noted.
15-7/8
(40.3)
4-3/8
(11.1)
Aperture: 7-7/8 (20.1)
Ceiling Opening: 8-7/8 (22.5)
5-3/16
(13.2)
Overlap Trim: 9-1/4 (23.5)
14-1/2
(36.8)
ORDERING NOTES
1. Not available with finishes.
2. Multi-volt electronic ballast capable of operating on any voltage from 120V
through 277V, 50 or 60 Hz.
3. For additional ballast types, refer to TECH-250.
4. Available in 120V or 277V only.
5. SIMPLY5 includes 9’ S5 MLC RELOC
Available in 120V or 277V only. Not available in 18W. See simply5.net for
more information.
®
wiring system (shipped separately).
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 06/11/13. Specifications subject to change without notice.
6. For dimensional changes, refer to TECH-140.
7. Not available with emergency options.
8. Must specify wattage. Ex.: WRL32
AFWLP-8
PAGE 2 OF 3

8” AFWLP
Low Profile Wallwash
Horizontal DTT or TRT lamp
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
AFWLP 1/42TRT 8AR
600
1200
1800
0° 20°
AFWLP 2/26TRT 8AR
400
800
1200
0° 20°
80°
60°
40°
80°
60°
40°
(1) CF42TRT, 3200 LUMENS PER LAMP, 0.9 S/MH, TEST NO. LTL19292
AveLumens
0
1888
5
1822
15
1478
25
1161
35
884
45
620
55
317
65
122
75
22
85
90
ZoneLumens% Lamp
0° - 30°
1112.6
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1665.2
2426.8
2582.7
0.0
2582.7
*Efficiency
167
412
534
553
474
288
122
28
5
6
0
pc 80%70% 50%
pw 50%30%10%50% 30%10% 50%30% 10%
34.8
52.0
75.8
80.7
0.0
*80.7
0
1
2
3
4
5
RCR
6
7
8
9
10
85
87
74
79
66
71
59
65
53
59
48
54
44
50
40
46
37
43
34
40
96
96
94
96
85
82
77
71
70
62
64
54
58
48
53
43
49
39
45
36
42
33
39
30
(2) CF26TRT, 1800 LUMENS PER LAMP, 1.0 S/MH, TEST NO. LTL19293
AveLumens
0
1424
5
1401
15
1292
25
1050
35
804
45
555
55
306
65
114
75
19
85
90
ZoneLumens% Lamp
0° - 30°
976.2
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1478.6
2181.3
2325.8
0.0
2325.8
*Efficiency
133
361
482
502
427
275
116
24
4
5
0
pc 80%70% 50%
pw 50%30%10%50% 30%10% 50%30% 10%
27.1
41.1
60.6
64.6
0.0
*64.6
0
1
2
3
4
5
RCR
6
7
8
9
10
68
70
59
63
52
57
47
51
42
47
38
43
34
39
31
36
29
34
27
31
77
77
75
77
68
66
62
57
56
49
51
43
46
38
42
34
39
31
36
28
33
26
31
24
94
81
83
70
73
61
65
54
58
48
52
43
47
39
43
36
40
33
37
30
34
75
75
65
66
56
59
49
52
43
46
38
42
34
38
31
34
28
31
26
29
24
26
79
80
82
69
71
75
68
62
56
52
48
44
41
39
72
66
60
54
49
45
41
38
35
33
30
Mounting
60
64
57
51
47
43
39
36
33
72
64
57
51
45
41
37
34
31
28
26
Height
53
8.0
48
10.0
43
12.0
39
14.0
35
16.0
33
30
72
63
55
Mounting
48
Height
42
8.0
38
10.0
34
12.0
31
14.0
28
16.0
25
23
90
90
90
94
50% beam -
Inital FC
Center
Beam Diameter FC DiameterFC
62.4
33.6
20.9
14.3
10.4
Inital FC
Center
BeamDiameterFC DiameterFC
47.1
25.3
15.8
10.8
46.3°
4.7
6.4
8.1
9.8
11.5
50% beam -
53.8°
5.6
7.6
9.6
11.7
13.7
7.8
31.2
16.8
10.5
7.1
5.2
23.5
12.7
7.9
5.4
3.9
10% beam -
92.8°
11.6
15.8
20.0
24.2
28.4
10% beam -
96.2°
12.3
16.7
21.2
25.6
30.1
6.2
3.4
2.1
1.4
1.0
4.7
2.5
1.6
1.1
0.8
AFWLP 2/32TRT 8AR
600
1200
0° 20°
80°
60°
40°
(2) CF32TRT,2400 LUMENS PER LAMP, 1.0 S/MH, TEST NO. LTL19294
AveLumens
0
1700
5
1668
15
1512
25
1237
35
947
45
653
55
366
65
132
75
23
85
90
ZoneLumens% Lamp
0° - 30°
1148.8
0° - 40°
0° - 60°
0° - 90°
90° - 180°
0° - 180°
1740.4
2572.0
2741.1
0.0
2741.1
*Efficiency
158
423
568
592
503
328
135
28
5
6
0
pc 80%70% 50%
pw 50%30%10%50% 30%10% 50%30% 10%
23.9
36.3
53.6
57.1
0.0
*57.1
0
1
2
3
4
5
RCR
6
7
8
9
10
68
68
60
62
53
56
46
50
41
45
37
41
33
38
30
35
28
32
25
30
24
28
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory condition.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
68
58
50
43
38
34
30
27
25
23
21
57
59
60
49
52
55
43
46
49
38
41
45
34
37
41
30
33
37
27
30
34
25
28
32
23
25
29
21
23
27
55
57
58
48
50
53
48
43
40
36
33
31
29
27
Mounting
42
45
40
36
33
30
27
25
23
Height
37
8.0
33
10.0
30
12.0
27
14.0
25
16.0
22
21
63
63
63
66
66
66
50% beam -
Inital FC
Center
Beam Diameter FC DiameterFC
56.2
30.2
18.8
12.9
53.3°
5.5
7.5
9.5
11.5
13.5
9.3
28.1
15.1
9.4
6.4
4.7
10% beam -
96.0°
12.2
16.7
21.1
25.5
30.0
5.6
3.0
1.9
1.3
0.9
AFWLP-8
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2010-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 06/11/13. Specifications subject to change without notice.