Luminaire Type:
Catalog Number
(autopopulated):
Gotham Architectural Downlighting
Compact Fluorescent Downlights
8” AFV
Open Reflector
Vertical Lamp
Double Twin-Tube or Triple-Tube
FEAT URES ORDERING INFORMATION
OPTICAL SYSTEM
• Self-flanged, semi-specular or matte-diffuse reflector. Patented Vertisys® Bounding Ray™ Optical Principle design (US Patent No. 5,800,050).
MECHANICAL SYSTEM
• 16-gauge galvanized steel construction; maximum 7/8” ceiling thickness.
• Telescopic mounting bars maximum of 32” and minimum of 15”, preinstalled,
4” vertical adjustment.
• Toolless post-installation adjustments.
• Junction box capacity: 8 (4 in, 4 out) 12AWG rated for 90°C.
ELECTRICAL SYSTEM
• Rugged aluminum lampholder housing.
• Vertically mounted, positive-latch, thermoplastic socket.
• Class P, thermally protected, high-power-factor electronic ballast mounted to the
junction box.
• SIMPLY5™ technology available.
EXAMPLE: AFV 32TRT 8AR MVOLT WLP
LISTING
• Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and
damp locations. Listed and labeled to comply with Canadian standards.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Wattage/Lamp Aperture/Trim color Finish Lens type Voltage Ballast
AFV 13DTT
18DTT
26DTT
13TRT
18TRT
26TRT
32TRT
42TRT
8AR Clear
8PR Pewter
8WTR Wheat
1
8WR
White painted
1
8MB
Black baffle
1
8WB
White baffle
(blank) Semi-
specular
LD Matte-
diffuse
(blank)
No lens
CGL Clear glass lens
CAL Clear acrylic lens
PCL Clear polycarbonate lens
T73 Tempered prismatic lens
A12 Prismatic acrylic lens
PPC Prismatic polycarbonate
lens
MVOLT
120
277
347
2
(blank) Electronic ballast
ECOS
ADEZ
ADZT
FOL Flat opal lens
3
2, 4
Lutron® EcoSystem® electronic dimming
ballast. Minimum dimming level 5%
4, 5
Advance Mark 10® electronic dimming
ballast. Minimum dimming level 5%
2
Advance Mark 7® electronic dimming
ballast. Minimum dimming level 5%
Options
5, 6
EL
ELR
ELHL
ELRHL
GLR
Emergency battery pack with integral test switch
5, 6
Emergency battery pack with remote test switch
5, 6
High-lumen-output emergency battery pack with
integral test switch
5, 6
High-lumen-output emergency battery pack with
remote test switch
7
Single, fast-blow fuse
7
GMF
Single, slow-blow fuse
TRW White painted flange (standard on MB and WB)
TRBL Black painted flange
GSKT Foam gasketing
WLP With 3500 K lamp (shipped separately)
8
RRL
RELOC®-ready luminaire. Provides compatibility
with Lithonia RELOC system. Access above ceiling required.
ACCESSORIES order as separate catalog numbers (shipped separately)
SCA8 Sloped ceiling adapter. Degree of slope must be specified (10D, 15D, 20D, 25D, 30D). Ex: SCA8 10D.
CTA4-8 YK Ceiling thickness adapter. (Extends mounting frame to accommodate ceiling thickness up to 4-1/4” DTT and 3-1/4 TRT)
AFV-8-OPEN
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 12/30/13. Specifications subject to change without notice.
HW Hardwire for S5 system; replaces RELOC
9
CP
BDP
NEPP Interface for Sensor Switch
Chicago plenum
9, 10
Ballast disconnect plug
®
nLight® network
with integral power supply. Refer to TN-623-01.
WL Wet location; lens required
11
WRL
Wattage restriction label
TWS Twist lock socket
®
8” AFV
Open Reflector
Vertical Lamp, Double Twin-Tube or Triple-Tube
DIMENSIONAL DATA ELECTRICAL NOTES
All dimensions are inches (centimeters) unless otherwise noted.
*11 (27.9)
15-13/16
(40.2)
Aperture: 7-7/8 (20.1)
Ceiling opening: 8-7/8 (21.5)
13-3/4
(34.9)
Overlap trim: 9-1/4 (23.5)
Lens recess: 3 (7.6)
DIMENSIONAL NOTES
• Maximum height depends on lamp wattage/type, dimensions range from 11” for 18DTT, 26DTT and 42TRT; 10-1/8” for 13DTT, 18TRT, 26TRT and 32TRT.
ENERGY
(Calculated in accordance with NEMA standard LE-5A)
Annual*
Energy
LER.DOH
Cost
$5.99
40
$4.98
48
$5.24
46
$6.07
40
*
Comparative yearly lighting energy cost per 1000 lumens
Lamps
(1) 26W DTT
(1) 26W DTT
(2) 32W TRT
(2) 42W TRT
Lamp
Lumens
1800
1800
2400
3200
Ballast
Factor
1.00
1.00
0.98
1.00
Input
Watts
28
28
36
46
ORDERING NOTES
1. Not available with finishes.
2. Multi-volt electronic ballast capable of operating on any voltage from 120V
through 277V, 50 or 60 Hz.
3. For additional ballast types, refer to TECH-250.
4. Not available in 13W.
5. Available in 120V or 277V only.
6. For dimensional changes, refer to TECH-140.
7. Not available with MVOLT; must specify voltage.
8. For compatible RELOC systems, refer to TECH-110.
9. Not available with EL, ELHL, ELR or ELRHL option.
10. Meets codes that require in-fixture disconnect.
11. Must specify wattage: Ex.: WRL32
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com