Luminaire Type:
Catalog Number
(autopopulated):
Gotham Architectural Downlighting
Decorative Fluorescent Downlights
6” PDRGF
Semi-recessed Glass Shade
Triple-Tube and Double Twin-Tube Lamps
FEAT URE S ORDERING INFORMATION NOTES
GLASS SHADE
• Semi-recessed shade is pressed, colored glass with an acid etched exterior
finish and a matte white glazed interior décor. Available in white, amber or blue.
• Minimum flange with textured polyester powder paint finish available in matte
white, matte black or satin silver.
MECHANICAL SYSTEM
• 16-gauge painted steel mounting/plaster frame with integral brackets to retain
glass shade. Maximum 1-1/2” ceiling thickness.
• 16-gauge galvanized steel mounting bars with continuous 4” vertical adjustment are shipped pre installed. Post installation adjustment possible without
the use of tools from above or below ceiling.
• Galvanized steel junction box with hinged access covers and spring latch. Two
combination 1/2”-3/4” and three 1/2” knockouts for straight-through conduit
runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors rated for 90°C.
EXAMPLE: PDRGF 18TRT 6WG DBLB MVOLT
ELECTRICAL SYSTEM
• Vertically-mounted, four-pin, positive-latch, thermoplastic socket.
• Class P, thermally-protected, high power factor electronic ballast mounted to the
junction box.
LISTING
• Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and
damp locations. Listed and labeled to comply with US and Canadian standards.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Wattage/
Series
PDRGF 13DTT
Lamp Shade color Flange color Voltage Ballast Options
13TRT
18DTT
18TRT
26DTT
26TRT
32TRT
6WG White
glass
6AG Amber
glass
6BG Blue
glass
DWHG Matte
white
DBLB Matte
black
DNAS Satin
silver
MVOLT
120
277
347
1
(blank) Electronic ballast
2
ADZT
ECOS
ADEZ
Advance Mark 7® electronic
0-10V dimming ballast
2,3
Lutron EcoSystem® electronic dimming ballast
4
Advance Mark 10®
electronic line-voltage
dimming ballast
4,5
DMHL3
Lutron Hi-Lume® 1% electronic dimming ballast
2,6
ELR
2,6
ELRHL
2,6
ELRSD
ELRB94
2,6
BGTD
WLP 3500 K lamp (shipped separately)
7
RRL
Emergency battery pack. Remote test switch provided.
High lumen output emergency battery pack. Remote
test switch provided.
Emergency battery pack with self diagnostics. Remote
test switch provided.
2,6
Bodine B94 emergency battery pack. Remote test
switch provided.
Bodine GTD™ generator transfer device
RELOC®-ready luminaire. Provides compatibility with
Lithonia RELOC system. Access above ceiling required.
CP Chicago plenum
NEPP
GMF
GLR
Interface for Sensor Switch® nLight® network with
integral power supply. Refer to TN-623-01.
4
Single, slow-blow fuse
4
Single, fast-blow fuse
ORDERING NOTES
1. Multi-volt electronic ballast capable of operating on any line voltage from
120V through 277V, 50 or 60 HZ.
2. Not available with 347V.
3. Not available with 13W.
4. 120V or 277V only.
PDRGF-6-SHADE
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/07/14. Specifications subject to change without notice.
5. Available in 26W and 32W only.
6. For dimensional changes, refer to TECH-140.
7. For compatible RELOC systems, refer to TECH-110.

6” PDRGF
Overlap Trim: 7-7/8 (20.0)
Semi-recessed Glass Shade
Triple-Tube and Double Twin-Tube Lamps
DIMENSIONAL DATA
All dimensions are inches (centimeters) unless otherwise noted.
(34.0)
9-5/16
3-1/2
(23.6)
(8.9)
15-7/8
(40.3)
Shade Aperture: 5-1/4 (13.4)
Ceiling Opening: 7-1/8 (18.1)
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/07/14. Specifications subject to change without notice.
PDRGF-6-SHADE
PAGE 2 OF 3

6” PDRGF
Semi-recessed Glass Shade
Triple-Tube and Double Twin-Tube Lamps
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
PDRGF 6AG
50
PDRGF 6BG
0
0
0° 10° 20° 30°
80°
70°
60°
50°
40°
80°
70°
60°
50°
40°
18TRT amber glass, 1200 rated lumens, 1.2 s/mh, Test No. LTL15796
From 0° AveLumens
0
150
5
154
165
145
92
60
36
20
11
15
46
66
58
46
32
20
12
4
4
0
15
25
35
45
55
65
75
85
90
Zone Lumens % Lamp
127.2
0° - 30°
185.6
0° - 40°
264.1
0° - 60°
300.0
0° - 90°
90° - 180°
0° - 180°
0.0
300.0
*E ciency
*25.0
10.6
15.5
22.0
25.0
0.0
pf
pc
pw
50%30% 50%30% 50% 30%
1
.27
2
.24
3
.21
4
.19
5
.18
6
.16
7
.15
8
.14
9
.13
10
.12
26TRT blue glass, 1800 rated lumens, 1.3 s/mh, Test No. LTL15792
From 0° AveLumens
0
240
5
245
264
242
174
106
65
36
18
24
75
110
108
82
58
36
19
5
6
0
15
25
35
45
55
65
75
85
90
Zone Lumens % Lamp
208.6
0° - 30°
316.6
0° - 40°
457.4
0° - 60°
518.4
0° - 90°
90° - 180°
0° - 180°
0.0
518.4
*E ciency
*28.8
11.6
17.6
25.4
28.8
0.0
pc
50%30% 50% 30% 50% 30%
pw
1
.31
2
.27
3
.25
4
.22
5
.20
6
.18
7
.17
8
.16
9
.14
10
.13
.30
.26
.23
.20
.18
.16
.15
.13
.12
.11
.26
.22
.20
.17
.16
.14
.13
.12
.11
.10
.30
.27
.24
.22
.20
.18
.17
.15
.14
.13
.26
.23
.21
.19
.17
.16
.15
.14
.13
.12
20%
.29
.25
.22
.20
.18
.16
.14
.13
.12
.11
.25
.22
.19
.17
.16
.14
.13
.12
.11
.10
.29
.26
.23
.21
.19
.18
.16
.15
.14
.13
.25
.23
.20
.18
.17
.15
.14
.13
.12
.11
80%70% 50%
80%70% 50%
.28
.25
.22
.19
.17
.16
.14
.13
.12
.11
.24
.21
.19
.17
.15
.14
.13
.12
.11
.10
Mount
height
10
12
14
16
Mount
height
8
10
12
14
16
8
Inital fc
at be am
center
5.0
2.7
1.7
1.1
0.8
Inital fc
at be am
center
7.9
4.3
2.7
1.8
1.3
50% be am angle
61.2°
fc at
beam
Beam
11.2
13.6
16.0
6.9
9.4
11.9
14.4
16.9
6.5
8.9
64.1°
edge
2.5
1.3
0.8
0.6
0.4
fc at
beam
edge
4.0
2.1
1.3
0.9
0.7
diameter
50% be am angle
Beam
diameter
10% be am angle
96.6°
fc at
beam
Beam
12.3
16.8
21.3
25.8
30.3
12.8
17.5
22.1
26.8
31.4
98.6°
edge
fc at
beam
edge
0.8
0.4
0.3
0.2
0.1
diameter
10% be am angle
Beam
diameter
0.5
0.3
0.2
0.1
0.1
PDRGF 6WG
80°
60°
200
40°
32TRT white glass, 2400 rated lumens, 1.4 s/mh, Test No. LTL15788
AveLumens
0
266
5
275
15
303
25
299
35
247
45
177
55
127
65
94
75
72
85
53
90
0
137
154
138
114
Zone Lumens % Lamp
0° - 30°
249.7
0° - 40°
27
86
94
76
53
0° - 60°
0° - 90°
90° - 180°
0° - 180°
403.5
655.1
878.6
0.0
878.6
*Efficiency
*36.6
pc 80% 70% 50%
pw 50%30% 10% 50% 30%10% 50%30% 10%
10.4
16.8
27.3
36.6
0.0
0
1
2
3
4
5
RCR
6
7
8
9
10
44
44
44
34
35
37
27
30
32
23
25
28
19
22
25
17
19
23
15
17
20
13
15
19
12
14
17
11
13
16
10
12
14
43
33
35
36
27
29
32
23
25
28
19
22
25
17
19
22
15
17
20
13
15
18
12
14
17
11
13
15
10
11
14
32
33
35
26
28
30
27
24
21
19
18
16
15
14
Mounting
22
24
21
19
17
15
14
12
11
Height
19
8.0
17
10.0
15
12.0
13
14.0
12
16.0
11
10
41
41
41
43
43
50% beam -
7.8
10.6
13.5
16.3
19.1
70.6°
Inital FC
Center
Beam Diameter FC DiameterFC
8.8
4.7
2.9
2.0
1.5
4.4
2.4
1.5
1.0
0.7
10% beam -
108.0°
15.2
20.7
26.2
31.7
37.2
0.9
0.5
0.3
0.2
0.1
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
PDRGF-6-SHADE
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2007-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/07/14. Specifications subject to change without notice.