Gotham 6 LGF SpecSheet

Page 1
Luminaire Type: Catalog Number (autopopulated):
Gotham Architectural Downlighting Compact Fluorescent Downlights
6” LGF
Round Lens
Wet Location Horizontal Triple-Tube Lamp
FEAT URES ORDERING INFORMATION
OPTICAL SYSTEM
Aluminum upper reflector coated with highly reflective white paint provides high efficiency and an evenly illuminated aperture appearance.
Available with tempered prismatic lens (T73), flat Fresnel lens (FFL) or flat opal lens (FOL).
Regressed white door (RW) or stepped black baffle (SB) are available with white painted flange provided.
Door is retained by self-aligning, torsion support springs, preventing gaps between door and ceiling.
MECHANICAL SYSTEM
16-gauge galvanized steel mounting/plaster frame with integral yoke to retain optical system. Maximum 1-1/2” ceiling thickness.
16-gauge galvanized steel mounting bars with continuous 4” vertical adjust­ment are shipped pre-installed. Post installation adjustment possible without the use of tools from above or below ceiling.
Galvanized steel junction box with hinged access covers and spring latch. Two combination 1/2”–3/4” and three 1/2” knockouts for straight-through conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors, rated for 90°C.
EXAMPLE: LGF 1/26TRT 6RW T73 MVOLT
ELECTRICAL SYSTEM
Galvanized steel lampholder housing.
Horizontally-mounted, four-pin, positive-latch, thermoplastic socket.
Class P, thermally-protected, high power factor, electronic ballast mounted to the junction box.
LISTING
Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and wet locations. Listed and labeled to comply with Canadian standards.
WARRANTY
1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Wattage/Lamp Door frame Lens type Voltage Ballast
LGF 1/18TRT
1/26TRT 1/32TRT 1/42TRT
1
6RW Regressed white door 6SB Stepped black baffle
T73 Tempered prismatic lens FFL Flat fresnel lens FOL Flat opal lens PPC Prismatic polycarbonate lens
MVOLT 120 277 347
(blank) Electronic ballast (standard)
ECOS EcoSystem electronic dimming ballast. Minimum
ADEZ
2
ADZT
dimming level 5%.
3,4
Advance Mark X® electronic dimming ballast. Minimum dimming level 5%
4
Advance Mark VII™ electronic dimming ballast
Options
CP Chicago plenum
5
TRDA RRL
Tamper resistant door assembly
6
RELOC®-ready luminaire. Provides compatibility with Lithonia RELOC system. Access
above ceiling required.
GMF Single, slow-blow fuse (not available with MVOLT) GLR Single, fast-blow fuse (not available with MVOLT) WLP Lamp (shipped separately)
ACCESSORIES order as separate catalog numbers (shipped separately)
SCA6
LGF-6-ROUND-LENS
PAGE 1 OF 3
Sloped ceiling adapter. Degree of slope must be specified (10D, 15D, 20D, 25D, 30D). Ex: SCA6 10D.
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2005-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 10/02/13. Specifications subject to change without notice.
RIF Radio interference filter
7
QDS
Quick Disconnect System for easy ballast replacement
ELR8Emergency battery pack. Remote test switch
8
ELRSD
High lumen output emergency battery pack. Remote test switch provided
GSKT Foam gasketing ships uninstalled NEPP
Interface for Sensor Switch® nLight® network with integral power supply. Refer to TN-623-01.
Page 2
6” LGF
Overlap Trim: 7-1/2 (19.1)
Round Lens
Wet Location, Horizontal Triple-Tube Lamp
DIMENSIONAL DATA ELECTRICAL NOTES
All dimensions are inches (centimeters) unless otherwise noted.
6-3/4
(17.1)
15-7/8 (40.3)
Aperture: 6-1/4 (15.9)
13-7/8 (35.2)
Ceiling Opening: 7-1/8 (18.1)
ORDERING NOTES
1. Will also operate 26DTT 4-PIN lamp.
2. Multi-volt electronic ballast capable of operating on any voltage from 120V through 277V, 50 or 60 Hz.
3. Not available with MVOLT.
4. Not available with 347V.
5. Uses Torx T20 rejection pin drive system. You may order RK1 T20DRV U Torx driver accessory.
6. For compatible RELOC systems, refer to TECH-110.
7. Not available with ELR or ELRSD option.
8. For dimensional changes refer to TECH-140.
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2005-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 10/02/13. Specifications subject to change without notice.
LGF-6-ROUND-LENS
PAGE 2 OF 3
Page 3
6” LGF
90°
100
200
300
400
500
600
700
0° 10° 20° 30°
100
200
300
400
500
600
700
800
Round Lens
Wet Location, Horizontal Triple-Tube Lamp
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
LGF 1/32TRT 6RW T73
80°
70°
60°
50°
40°
0° 10° 20° 30°
LGF 1/32TRT 6RW FFL
90°
80°
70°
60°
50°
40°
32TRT LAMP, 1.1 S/MH, 2400 RATED LUMENS, TEST NO. LTL14212
From 0° AveLumens
0
760
5
758 724 627 460 270 130
62 23
72 203 287 286 209 119
62
26
6
6
0
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
562.1
0° - 30°
848.1
0° - 40°
1176.6
0° - 60°
1271.4
0° - 90°
90° - 180°
0° - 180°
0.0
1271.4
*E fficiency
*53.0
23.4
35.3
49.0
53.0
0.0
pf pc pw
50% 30% 50%30% 50%30%
1
.57
2
.52
3
.47
4
.42
5
.39
6
.35
7
.33
8
.30
9
.28
10
.26
32TRT LAMP, 1.1 S/MH, 2400 RATED LUMENS, TEST NO. LTL14213
F rom 0° AveLumens
0
848
5 15 25 35 45 55 65 75 85 90
855 800 661 487 296 163
82 30
81 224 304 303 229 148
82
33
7
8
0
Zone Lumens % Lamp
608.8
0° - 30°
911.3
0° - 40°
1288.2
0° - 60°
1410.0
0° - 90°
90° - 180°
0° - 180°
0.0
1410.0
*E fficiency
*58.7
25.4
38.0
53.7
58.7
0.0
pf pc pw
50% 30% 50% 30% 50% 30%
1
.63
2
.57
3
.51
4
.47
5
.42
6
.39
7
.36
8
.33
9
.31
10
.29
.55 .49 .43 .39 .35 .31 .29 .26 .24 .22
.61 .54 .47 .42 .38 .34 .31 .29 .26
.24
.56
.51 .46 .42 .38 .35 .32 .30 .28 .26
.62 .56 .50 .46 .42 .38 .35 .33 .30 .28
20%
20%
.54 .48 .43 .38 .34 .31 .28 .26 .24 .22
.60 .53 .47 .42 .38 .34 .31 .28 .26 .24
.54 .49 .44 .40 .37 .34 .31 .29 .27 .25
.59 .54 .49 .44 .41 .37 .34 .32 .30 .28
80%70% 50%
80% 70% 50%
.52 .47 .42 .37 .34 .31 .28 .26 .24 .22
.58 .51 .46 .41 .37 .34 .31 .28 .26 .24
Mount height
8 10 12 14 16
Mount height
8 10 12 14 16
Inital fc
at be am
center
25.1
13.5
8.4
5.7
4.2
Inital fc
at be am
center
28.0
15.1
9.4
6.4
4.7
50% be am angle
57.9° fc at
beam
Beam
6.1
8.3
10.5
12.7
14.9
Beam
5.8
7.9
10.1
12.2
14.3
55.8°
edge
12.6
6.8
4.2
2.9
2.1
fc at
beam
edge
14.0
7.5
4.7
3.2
2.3
diameter
50% be am angle
diameter
10% be am angle
93.8° fc at
beam
Beam
11.7
16.0
20.3
24.6
28.8
Beam
11.8
16.1
20.4
24.7
28.9
94.0°
edge
2.5
1.4
0.8
0.6
0.4
fc at
beam
edge
2.8
1.5
0.9
0.6
0.5
diameter
10% be am angle
diameter
PHOTOMETRY NOTES
Tested to current IES and NEMA standards under stabilized laboratory conditions.
Actual performance may differ as a result of end-user environment and application.
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
LGF-6-ROUND-LENS
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2005-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 10/02/13. Specifications subject to change without notice.