Gotham 4 AFV SpecSheet

Luminaire Type: Catalog Number (autopopulated):
Gotham Architectural Downlighting Compact Fluorescent Downlights
4” AFV
Open Reflector
Vertical Lamp Double Twin-Tube or Triple-Tube
FEAT URES ORDERING INFORMATION
OPTICAL SYSTEM
Self-flanged, semi-specular or matte-diffuse reflector. Patented Vertisys® ­Bounding Ray™ Optical Principle design (US Patent No. 5,800,050).
MECHANICAL SYSTEM
16-gauge galvanized steel construction; maximum 1-5/8” ceiling thickness.
Telescopic mounting bars maximum of 32” and minimum of 15”, preinstalled, 4” vertical adjustment.
Toolless post-installation adjustments.
Junction box capacity: 8 (4 in, 4 out) 12AWG rated for 90°C.
ELECTRICAL SYSTEM
Rugged aluminum lampholder housing.
Vertically mounted, positive-latch, thermoplastic socket.
Class P, thermally protected, high-power-factor electronic ballast mounted to the junction box.
SIMPLY5™ technology available.
EXAMPLE: AFV 26TRT 4AR MVOLT WLP
LISTING
Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and damp locations. Listed and labeled to comply with Canadian standards.
WARRANTY
1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Wattage/Lamp Aperture/Trim color Finish Lens type Voltage
AFV 13DTT
13TRT 18TRT 26TRT 32TRT
4AR Clear 4PR Pewter 4WTR Wheat
1
4MB
Black baffle
1
4WB
White baffle
4WR White reflector
(blank) Semi-specular LD Matte-diffuse
(blank) No lens
CGL Clear glass lens PCL Clear polycarbonate lens T73 Tempered prismatic lens CAL Clear acrylic lens A12 Prismatic acrylic lens
MVOLT 120 277 347
PPC Prismatic polycarbonate lens
2
3
Ballast
(blank) Electronic ballast
2, 4
ECOS
ADEZ
ADZT
Lutron® EcoSystem® electronic dimming ballast. Minimum dimming level 5%
4, 5
Advance Mark 10® electronic dimming ballast. Minimum dimming level 5%
2
Advance Mark 7® electronic dimming ballast. Minimum dimming level 5%
Options
5, 6
ELR ELRHL
GMF GLR
Emergency battery pack with remote test switch
5, 6
High-lumen-output emergency battery pack with remote test switch
7
Single, slow-blow fuse
7
Single, fast-blow fuse
TRW White painted flange (standard on MB and WB) TRBL Black painted flange GSKT Foam gasketing WLP With 3500 K lamp (shipped separately)
ACCESSORIES order as separate catalog numbers (shipped separately)
SCA4 Sloped ceiling adapter. Degree of slope must be specified (10D, 15D, 20D, 25D, 30D). Ex: SCA4 10D.
AFV-4-OPEN
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2003-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/30/14. Specifications subject to change without notice.
8
RRL
RELOC®-ready luminaire. Provides compat­ibility with Lithonia RELOC system. Access above ceiling required.
HW Hardwire for S5 system; replaces RELOC
9
CP BDP NEPP Interface for Sensor Switch
Chicago plenum
9, 10
Ballast disconnect plug
®
nLight® network with integral power supply. Refer to TN-623-01.
WL Wet location; lens required
11
WRL
Wattage restriction label
TWS Twist lock socket
4” AFV
(34.0)
Open Reflector
Vertical Lamp, Double Twin-Tube or Triple-Tube
DIMENSIONAL DATA ELECTRICAL NOTES
All dimensions are inches (centimeters) unless otherwise noted.
15-7/8 (40.3)
13-3/8
9-3/8 (23.8)
Aperture: 4-5/16 (11) Ceiling Opening: 5-1/8 (13) Overlap Trim: 5-7/16 (13.8) Lens recess: 1-1/2 (3.8)
ENERGY
(Calculated in accordance eith NEMA standard LE-5A)
Annual*
Energy
LER.DOH
Cost
$11.47
21
$ 9.07
26
$11.38
21
*
Comparative yearly lighting energy cost per 1000 lumens
Lamps (1) 13W DTT (1) 18W TRT (1) 26W TRT
Lamp
Lumens
900 1200 1800
Ballast
Factor
1.0
1.0
1.0
Input
Watts
16 20 28
ORDERING NOTES
1. Not available with finishes.
2. Multi-volt electronic ballast capable of operating on any voltage from 120V through 277V, 50 or 60 Hz.
3. For additional ballast types, refer to TECH-250.
4. Not available with 13W.
5. Available in 120V or 277V only.
6. For dimensional changes, refer to TECH-140.
7. Not available with MVOLT; must specify voltage
8. For compatible RELOC systems, refer to TECH-110.
9. Not available with ELR or ELRHL option.
10. Meets codes that require in-fixture disconnect.
11. Must specify wattage: Ex.: WRL26