Luminaire Type:
Catalog Number
(autopopulated):
Gotham Architectural Downlighting
Compact Fluorescent Surface Downlights
FEAT URES ORDERING INFORMATION
14” PDPF
High Elevations
®
Performance Downlight Pendant
Vertical Triple-Tube Lamp
DECORATIVE HOUSING
• Durable, heavy-gauge aluminum housing allows for a dedicated optical system
with unparalleled performance. Textured polyester powder paint finish available
in matte black, satin silver or white.
• Upper ballast module houses all gear, including available emergency battery pack.
DECORATIVE ELEMENT
• Available with decorative glass refractor in white, amber or blue. Glass is pressed,
colored glass with an acid-etched exterior finish and a matte white painted interior
décor. Provides a color-luminous accent to highlight the ceiling cavity.
OPTICAL SYSTEM
• Self-flanged, semi-specular or matte-diffuse reflector. Patented Bounding Ray™
Optical Principle design (U.S. Patent No. 5,800,050) provides lamp before
lamp image and smooth transition from top of the reflector to bottom. Reflector
flange visually integrates with housing.
• Optional 1/8” clear or prismatic glass lens.
EXAMPLE: PDPF 4/32TRT 14AR MVOLT BL DWG ACC
Series # of lamps Wattage/Lamp Aperture/Trim color Finish Lens type Voltage Color
PDPF 1/
26TRT
2/
3/
4/
32TRT
42TRT
57TRT
1
14AR Clear
14PR Pewter
14UBR Umber
14WTR Wheat
(blank) Semi-
LD Matte-
MOUNTING OPTIONS
• PM - Pendant-mount entry provided for 3/8” National Pipe Thread stem. Swivel
mounting accessories available (see stem options).
• ACC - Aircraft cable and cord mount provided with 10ft. aircraft cable and
black cord.
ELECTRICAL SYSTEM
• Vertically mounted, positive-latch, thermoplastic socket(s).
• Class P, thermally protected high-power-factor electronic ballast(s).
LISTING
• Fixtures are UL listed for damp locations. Listed and labeled to comply with
Canadian standards.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
2
specular
diffuse
(blank) No lens
CGL Clear glass lens
T73 Tempered
prismatic lens
MVOLT
120
277
347
BL Matte black
SS Satin silver
WH White
3
Glass element
(blank) No glass
DWG White glass
DAG Amber glass
DBG Blue glass
Mounting Stem options Ballast
PM
ACC
4
5
Pendant 3/8”
thread mount
Aircraft cable
and cord
6
3/8” stem and
CYS
canopy with 5° “hang
straight” swivel
6
CRS
3/8” stem and canopy
with 45° swivel
7
(blank) Electronic ballast
8
ECOS
ADEZ
S5 HW
Lutron® EcoSystem® electronic dimming
ballast. Minimum dimming level 5%.
9
Advance Mark 10® electronic dimming
ballast. Minimum dimming level 5%.
1,9,10
SIMPLY5™ electronic dimming system
Options
11
DS
12
GMF
12
GLR
9
EL
13
WLP
Dual switching
Single slow-blow fuse
Single fast-blow fuse
Emergency battery pack with integral test switch.
1-lamp, 42W maximum
With 3500 K lamp (shipped separately)
ballast less RELOC.
ACCESSORIES order as separate catalog numbers (shipped separately)
NEPP5 D Sensor Switch
®
nLight® 0-10V dimming relay.
NOTES
ORDERING NOTES
1. Available in 1 or 2 lamp only.
2. Multi-volt electronic ballast capable of operating on any line voltage from
120V through 277V, 50 or 60Hz.
3. Additional architectural colors available; see www.lithonia.com/archcolors.
4. Available with CYS or CRS stem option only.
5. Provided with 10ft. aircraft cable and black cord. White cord standard when
white pendant is ordered. Consult factory for additional lengths.
6. For use with pendant mount (PM) units only. Length of stem must be specified
(from 12” to 48” in 2” even increments). EX: CYS12. Stems greater than 48”,
up to 240”, provided with couplers. Consult factory for exterior use.
PDPF-14-OPEN
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2008-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/13. Specifications subject to change without notice.
7. For additional ballast types, refer to TECH-250.
8. Not available with ACC mounting option.
9. Available in 120V or 277V only. 3-lamp max.
10. Not available with 57TRT.
11. Standard on 3- and 4-lamp fixtures. Stem required for DMHL and S5 HW.
12. Not available with MVOLT. Must specify voltage.
13. 4000 K lamp for 320MHC.

14” PDPF
High Elevations
Performance Downlight Pendant, Vertical Triple-Tube Lamp
®
DIMENSIONAL DATA ELECTRICAL
All dimensions are inches (centimeters) unless otherwise noted.
Metal or Glass
Aperture: 14 (35.6)
Overall Diameter: 15-1/2 (39.4)
Height: 23 (58.4)
ENERGY
(Ca lculated in accordance with NEMA standard LE-5A)
Annual*
Energy
LER.DVH
Cost
$4.99
48
$5.57
43
$5.54
43
*
Comparative yearly lighting energy cost per 1000 lumens
Lamps
(1) 57W TRT
(3) 42W TRT
(4) 42W TRT
Lamp
Lumens
4300
9600
12800
Ballast
Factor
1.00
1.00
1.00
Input
Watts
62
139
164
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2008-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/13. Specifications subject to change without notice.
PDPF-14-OPEN
PAGE 2 OF 3

14” PDPF
High Elevations
Performance Downlight Pendant, Vertical Triple-Tube Lamp
®
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
PDPF 3/42TRT 14AR DWG
90°
80°
500
1000
1500
2000
0° 10° 20° 30°
70°
60°
50°
40°
PDPF 4/42TRT 14AR
90°
80°
600
1200
1800
2400
0° 10° 20° 30°
70°
60°
50°
40°
(3) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 2.0 S/MH, TEST NO. LTL16537
From 0° AveLumens
0
1341
5
1441
1951
2468
2532
2016
496
27
30
39
44
145
563
1138
1572
1513
522
32
32
43
15
25
35
45
55
65
75
85
90
Zone Lumens % Lamp
1845.9
0° - 30°
3418.0
0° - 40°
5453.4
0° - 60°
5559.7
0° - 90°
0° - 180°
432.8
5992.6
*E ciency
*62.4
90° - 180°
19.2
35.6
56.8
57.9
4.5
pf
pc
80%70% 50%
pw
50%30% 50%30% 50%30%
1
.66
2
.60
3
.54
4
.48
5
.44
6
.39
7
.36
8
.33
9
.30
10
.27
.64
.56
.49
.44
.39
.34
.31
.28
.25
.23
.64
.58
.52
.47
.43
.39
.35
.32
.29
.27
20%
(4) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 2.0 S/MH, TEST NO. LTL16551
From 0° AveLumens
0
1701
5
1808
2452
3169
3287
2492
789
38
12
2
0
182
709
1461
2035
1889
755
52
13
3
15
25
35
45
55
65
75
85
90
Zone Lumens % Lamp
2352.3
0° - 30°
4387.3
0° - 40°
7031.6
0° - 60°
7100.1
0° - 90°
90° - 180°
0° - 180°
0.0
7100.1
*E ciency
*55.5
18.4
34.3
54.9
55.5
0.0
pf
pc
80%70% 50%
pw
50%30% 50%30% 50%30%
1
.60
2
.54
3
.49
4
.44
5
.40
6
.36
7
.33
8
.30
9
.27
10
.25
.58
.51
.45
.40
.35
.31
.28
.25
.23
.21
.59
.53
.48
.43
.39
.35
.32
.29
.27
.25
20%
.63
.55
.48
.43
.38
.34
.30
.27
.25
.22
.57
.50
.45
.39
.35
.31
.28
.25
.23
.21
.61
.55
.50
.45
.41
.37
.34
.31
.28
.26
.57
.51
.46
.42
.38
.34
.31
.29
.26
.24
.60
.53
.47
.41
.37
.33
.30
.27
.24
.22
.55
.49
.43
.39
.34
.31
.28
.25
.23
.20
Mount
height
8
10
12
14
16
Mount
height
8
10
12
14
16
Inital fc
at beam
center
49.9
23.8
14.9
10.1
7.4
Inital fc
at beam
center
62.3
30.2
18.8
12.9
9.3
50% be am angle
88.7°
fc at
beam
Beam
diameter
diameter
edge
25.0
10.8
13.4
14.7
8.4
18.6
5.7
22.5
4.1
26.4
50% be am angle
88.6°
fc at
beam
Beam
edge
31.2
10.7
16.8
14.6
10.4
18.6
7.1
22.5
5.2
26.4
10% be am angle
107.5°
fc at
beam
Beam
diameter
diameter
edge
5.0
15.0
2.7
20.5
1.7
25.9
1.1
31.4
0.8
36.8
10% be am angle
108.5°
fc at
beam
Beam
edge
6.2
15.3
3.3
20.9
2.1
26.4
1.4
32.0
1.0
37.5
PDPF 4/42TRT 14AR DWG
90°
80°
600
1200
1800
2400
0° 10° 20° 30°
70°
60°
50°
40°
PDPF 1/57TRT 14AR DWG
90°
80°
200
400
600
800
0° 10° 20° 30°
70°
60°
50°
40°
(4) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 2.1 S/MH, TEST NO. LTL16553
From 0° AveLumens
0
1617
5
1720
2330
3054
3135
2457
777
35
37
47
53
173
675
1406
1947
1862
745
45
39
51
15
25
35
45
55
65
75
85
90
Zone Lumens % Lamp
2254.4
0° - 30°
4201.6
0° - 40°
6808.3
0° - 60°
6942.6
0° - 90°
0° - 180°
511.7
7454.3
*E ciency
*58.2
90° - 180°
17.6
32.8
53.2
54.2
4.0
pc
pw
1
2
3
4
5
6
7
8
9
10
(1) CF57DT/E/IN/835, 4300 LUMENS PER LAMP, 1.7 S/MH, TEST NO. LTL16569
From 0° AveLumens
0
852
5
885
895
1006
1063
860
554
57
18
20
22
83
256
468
655
659
492
122
19
22
15
25
35
45
55
65
75
85
90
Zone Lumens % Lamp
806.5
0° - 30°
1461.8
0° - 40°
2612.1
0° - 60°
2774.4
0° - 90°
0° - 180°
206.7
2981.1
*E ciency
*69.3
90° - 180°
18.8
34.0
60.7
64.5
4.8
pf
pc
pw
1
2
3
4
5
6
7
8
9
10
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
80%70% 50%
50%30% 50%30% 50%30%
.62
.60
.60
.58
.69
.60
.52
.45
.40
.35
.31
.28
.25
.23
.51
.45
.40
.35
.31
.28
.25
.23
.21
.67
.60
.54
.48
.43
.39
.35
.32
.29
.27
.57
.51
.46
.42
.38
.34
.31
.29
.26
.24
.65
.57
.50
.44
.39
.34
.31
.27
.25
.22
.55
.52
.71
.61
.53
.46
.40
.36
.32
.28
.26
.23
.46
.41
.36
.32
.29
.26
.23
.21
.71
.63
.56
.50
.45
.41
.37
.33
.31
.28
.54
.49
.44
.40
.36
.32
.30
.27
.25
20%
.50
.45
.40
.37
.33
.30
.28
.25
80% 70%50%
50% 30% 50%30% 50% 30%
.73
.65
.58
.51
.46
.41
.38
.34
.31
.29
.56
.49
.43
.39
.34
.31
.27
.25
.22
.20
Mount
height
Mount
height
8
10
12
14
16
8
10
12
14
16
Inital fc
at beam
center
59.4
28.7
17.9
12.2
8.9
Inital fc
at beam
center
28.1
15.1
9.4
6.4
4.7
50% be am angle
89.3°
fc at
beam
Beam
9.4
10.9
14.8
18.8
22.7
26.7
80.8°
fc at
beam
edge
14.1
7.6
4.7
3.2
2.3
edge
diameter
50% be am angle
Beam
diameter
12.8
16.2
19.6
23.0
10% be am angle
Beam
diameter
29.7
16.0
9.9
6.8
4.9
10% be am angle
Beam
diameter
16.6
22.6
28.7
34.7
40.8
15.4
21.0
26.6
32.1
37.7
113.0°
108.8°
fc at
beam
edge
2.8
1.5
0.9
0.6
0.5
fc at
beam
edge
5.9
3.2
2.0
1.4
1.0
PDPF-14-OPEN
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com