Gotham 14 PDPF SpecSheet

Luminaire Type: Catalog Number (autopopulated):
Gotham Architectural Downlighting Compact Fluorescent Surface Downlights
FEAT URES ORDERING INFORMATION
14” PDPF
High Elevations
®
Performance Downlight Pendant Vertical Triple-Tube Lamp
DECORATIVE HOUSING
• Durable, heavy-gauge aluminum housing allows for a dedicated optical system with unparalleled performance. Textured polyester powder paint finish available in matte black, satin silver or white.
• Upper ballast module houses all gear, including available emergency battery pack.
DECORATIVE ELEMENT
• Available with decorative glass refractor in white, amber or blue. Glass is pressed, colored glass with an acid-etched exterior finish and a matte white painted interior décor. Provides a color-luminous accent to highlight the ceiling cavity.
OPTICAL SYSTEM
• Self-flanged, semi-specular or matte-diffuse reflector. Patented Bounding Ray™ Optical Principle design (U.S. Patent No. 5,800,050) provides lamp before lamp image and smooth transition from top of the reflector to bottom. Reflector flange visually integrates with housing.
• Optional 1/8” clear or prismatic glass lens.
EXAMPLE: PDPF 4/32TRT 14AR MVOLT BL DWG ACC
Series # of lamps Wattage/Lamp Aperture/Trim color Finish Lens type Voltage Color
PDPF 1/
26TRT 2/ 3/ 4/
32TRT
42TRT
57TRT
1
14AR Clear 14PR Pewter 14UBR Umber 14WTR Wheat
(blank) Semi-
LD Matte-
MOUNTING OPTIONS
• PM - Pendant-mount entry provided for 3/8” National Pipe Thread stem. Swivel mounting accessories available (see stem options).
• ACC - Aircraft cable and cord mount provided with 10ft. aircraft cable and black cord.
ELECTRICAL SYSTEM
• Vertically mounted, positive-latch, thermoplastic socket(s).
• Class P, thermally protected high-power-factor electronic ballast(s).
LISTING
• Fixtures are UL listed for damp locations. Listed and labeled to comply with Canadian standards.
WARRANTY
• 1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
2
specular
diffuse
(blank) No lens
CGL Clear glass lens T73 Tempered
prismatic lens
MVOLT 120 277 347
BL Matte black SS Satin silver WH White
3
Glass element
(blank) No glass
DWG White glass DAG Amber glass DBG Blue glass
Mounting Stem options Ballast
PM
ACC
4
5
Pendant 3/8” thread mount Aircraft cable and cord
6
3/8” stem and
CYS
canopy with 5° “hang straight” swivel
6
CRS
3/8” stem and canopy with 45° swivel
7
(blank) Electronic ballast
8
ECOS
ADEZ
S5 HW
Lutron® EcoSystem® electronic dimming ballast. Minimum dimming level 5%.
9
Advance Mark 10® electronic dimming ballast. Minimum dimming level 5%.
1,9,10
SIMPLY5™ electronic dimming system
Options
11
DS
12
GMF
12
GLR
9
EL
13
WLP
Dual switching Single slow-blow fuse Single fast-blow fuse Emergency battery pack with integral test switch. 1-lamp, 42W maximum With 3500 K lamp (shipped separately)
ballast less RELOC.
ACCESSORIES order as separate catalog numbers (shipped separately)
NEPP5 D Sensor Switch
®
nLight® 0-10V dimming relay.
NOTES
ORDERING NOTES
1. Available in 1 or 2 lamp only.
2. Multi-volt electronic ballast capable of operating on any line voltage from 120V through 277V, 50 or 60Hz.
3. Additional architectural colors available; see www.lithonia.com/archcolors.
4. Available with CYS or CRS stem option only.
5. Provided with 10ft. aircraft cable and black cord. White cord standard when white pendant is ordered. Consult factory for additional lengths.
6. For use with pendant mount (PM) units only. Length of stem must be specified (from 12” to 48” in 2” even increments). EX: CYS12. Stems greater than 48”, up to 240”, provided with couplers. Consult factory for exterior use.
PDPF-14-OPEN
PAGE 1 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2008-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/13. Specifications subject to change without notice.
7. For additional ballast types, refer to TECH-250.
8. Not available with ACC mounting option.
9. Available in 120V or 277V only. 3-lamp max.
10. Not available with 57TRT.
11. Standard on 3- and 4-lamp fixtures. Stem required for DMHL and S5 HW.
12. Not available with MVOLT. Must specify voltage.
13. 4000 K lamp for 320MHC.
14” PDPF High Elevations
Performance Downlight Pendant, Vertical Triple-Tube Lamp
®
DIMENSIONAL DATA ELECTRICAL
All dimensions are inches (centimeters) unless otherwise noted.
Metal or Glass
Aperture: 14 (35.6) Overall Diameter: 15-1/2 (39.4) Height: 23 (58.4)
ENERGY
(Ca lculated in accordance with NEMA standard LE-5A)
Annual*
Energy
LER.DVH
Cost
$4.99
48
$5.57
43
$5.54
43
*
Comparative yearly lighting energy cost per 1000 lumens
Lamps (1) 57W TRT (3) 42W TRT (4) 42W TRT
Lamp
Lumens
4300 9600
12800
Ballast
Factor
1.00
1.00
1.00
Input
Watts
62 139 164
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2008-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/13. Specifications subject to change without notice.
PDPF-14-OPEN
PAGE 2 OF 3
14” PDPF
pf
20%
High Elevations
Performance Downlight Pendant, Vertical Triple-Tube Lamp
®
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
PDPF 3/42TRT 14AR DWG
90°
80°
500
1000
1500
2000
0° 10° 20° 30°
70°
60°
50°
40°
PDPF 4/42TRT 14AR
90°
80°
600
1200
1800
2400
0° 10° 20° 30°
70°
60°
50°
40°
(3) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 2.0 S/MH, TEST NO. LTL16537
From 0° AveLumens
0
1341
5
1441 1951 2468 2532 2016
496
27 30 39 44
145
563 1138 1572 1513
522
32 32 43
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
1845.9
0° - 30°
3418.0
0° - 40°
5453.4
0° - 60°
5559.7
0° - 90°
0° - 180°
432.8
5992.6
*E ciency
*62.4
90° - 180°
19.2
35.6
56.8
57.9
4.5
pf pc
80%70% 50%
pw
50%30% 50%30% 50%30%
1
.66
2
.60
3
.54
4
.48
5
.44
6
.39
7
.36
8
.33
9
.30
10
.27
.64 .56 .49 .44 .39 .34 .31 .28 .25 .23
.64 .58
.52 .47 .43 .39 .35 .32 .29 .27
20%
(4) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 2.0 S/MH, TEST NO. LTL16551
From 0° AveLumens
0
1701
5
1808 2452 3169 3287 2492
789
38 12
2 0
182
709 1461 2035 1889
755
52 13
3
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
2352.3
0° - 30°
4387.3
0° - 40°
7031.6
0° - 60°
7100.1
0° - 90°
90° - 180°
0° - 180°
0.0
7100.1
*E ciency
*55.5
18.4
34.3
54.9
55.5
0.0
pf pc
80%70% 50%
pw
50%30% 50%30% 50%30%
1
.60
2
.54
3
.49
4
.44
5
.40
6
.36
7
.33
8
.30
9
.27
10
.25
.58 .51 .45 .40 .35 .31 .28 .25 .23 .21
.59 .53
.48 .43 .39 .35 .32 .29 .27 .25
20%
.63 .55 .48 .43 .38 .34 .30 .27 .25 .22
.57 .50 .45 .39 .35 .31 .28 .25 .23 .21
.61 .55 .50 .45 .41 .37 .34 .31 .28 .26
.57 .51 .46 .42 .38 .34 .31 .29 .26 .24
.60 .53 .47 .41 .37 .33 .30 .27 .24 .22
.55 .49 .43 .39 .34 .31 .28 .25 .23 .20
Mount height
8 10 12 14 16
Mount height
8 10 12 14 16
Inital fc at beam
center
49.9
23.8
14.9
10.1
7.4
Inital fc at beam
center
62.3
30.2
18.8
12.9
9.3
50% be am angle
88.7° fc at
beam
Beam
diameter
diameter
edge
25.0
10.8
13.4
14.7
8.4
18.6
5.7
22.5
4.1
26.4
50% be am angle
88.6° fc at
beam
Beam
edge
31.2
10.7
16.8
14.6
10.4
18.6
7.1
22.5
5.2
26.4
10% be am angle
107.5° fc at
beam
Beam
diameter
diameter
edge
5.0
15.0
2.7
20.5
1.7
25.9
1.1
31.4
0.8
36.8
10% be am angle
108.5° fc at
beam
Beam
edge
6.2
15.3
3.3
20.9
2.1
26.4
1.4
32.0
1.0
37.5
PDPF 4/42TRT 14AR DWG
90°
80°
600
1200
1800
2400
0° 10° 20° 30°
70°
60°
50°
40°
PDPF 1/57TRT 14AR DWG
90°
80°
200
400
600
800
0° 10° 20° 30°
70°
60°
50°
40°
(4) CF42DT/E/IN/835, 3200 LUMENS PER LAMP, 2.1 S/MH, TEST NO. LTL16553
From 0° AveLumens
0
1617
5
1720 2330 3054 3135 2457
777
35 37 47 53
173
675 1406 1947 1862
745
45 39 51
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
2254.4
0° - 30°
4201.6
0° - 40°
6808.3
0° - 60°
6942.6
0° - 90°
0° - 180°
511.7
7454.3
*E ciency
*58.2
90° - 180°
17.6
32.8
53.2
54.2
4.0
pc pw
1 2 3 4 5 6 7 8 9
10
(1) CF57DT/E/IN/835, 4300 LUMENS PER LAMP, 1.7 S/MH, TEST NO. LTL16569
From 0° AveLumens
0
852
5
885
895 1006 1063
860
554
57 18 20 22
83 256 468 655 659 492 122
19
22
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
806.5
0° - 30°
1461.8
0° - 40°
2612.1
0° - 60°
2774.4
0° - 90°
0° - 180°
206.7
2981.1
*E ciency
*69.3
90° - 180°
18.8
34.0
60.7
64.5
4.8
pf pc pw
1 2 3 4 5 6 7 8 9
10
PHOTOMETRY NOTES
• Tested to current IES and NEMA standards under stabilized laboratory conditions.
• Actual performance may differ as a result of end-user environment and application.
• Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
80%70% 50%
50%30% 50%30% 50%30%
.62
.60
.60
.58
.69 .60 .52 .45 .40 .35 .31 .28 .25 .23
.51 .45 .40 .35 .31 .28 .25 .23 .21
.67 .60 .54 .48 .43 .39 .35 .32 .29 .27
.57 .51 .46 .42 .38 .34 .31 .29 .26 .24
.65 .57 .50 .44 .39 .34 .31 .27 .25 .22
.55
.52
.71 .61 .53 .46 .40 .36 .32 .28 .26 .23
.46 .41 .36 .32 .29 .26 .23 .21
.71 .63
.56 .50 .45 .41 .37 .33 .31 .28
.54
.49 .44 .40 .36 .32 .30 .27 .25
20%
.50 .45 .40 .37 .33 .30 .28 .25
80% 70%50%
50% 30% 50%30% 50% 30%
.73 .65 .58 .51 .46 .41 .38 .34 .31 .29
.56 .49 .43 .39 .34 .31 .27 .25 .22 .20
Mount height
Mount height
8 10 12 14 16
8 10 12 14 16
Inital fc at beam
center
59.4
28.7
17.9
12.2
8.9
Inital fc at beam
center
28.1
15.1
9.4
6.4
4.7
50% be am angle
89.3° fc at
beam
Beam
9.4
10.9
14.8
18.8
22.7
26.7
80.8° fc at
beam
edge
14.1
7.6
4.7
3.2
2.3
edge
diameter
50% be am angle
Beam
diameter
12.8
16.2
19.6
23.0
10% be am angle
Beam
diameter
29.7
16.0
9.9
6.8
4.9
10% be am angle
Beam
diameter
16.6
22.6
28.7
34.7
40.8
15.4
21.0
26.6
32.1
37.7
113.0°
108.8°
fc at
beam
edge
2.8
1.5
0.9
0.6
0.5
fc at
beam
edge
5.9
3.2
2.0
1.4
1.0
PDPF-14-OPEN
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2008-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/13. Specifications subject to change without notice.