Gotham 10 LGF SpecSheet

Page 1
Luminaire Type: Catalog Number (autopopulated):
Gotham Architectural Downlighting Compact Fluorescent Downlights
10” LGF
Round Lens
Wet Location Horizontal Triple-Tube Lamp
FEAT URES ORDERING INFORMATION
OPTICAL SYSTEM
Aluminum upper reflector coated with highly reflective white paint provides high efficiency and an evenly illuminated aperture appearance.
Available with tempered prismatic lens (T73), flat Fresnel lens (FFL) or flat opal lens (FOL).
Regressed white door (RW) or stepped black baffle (SB) are available with white painted flange provided.
Door is retained by self-aligning, torsion support springs, preventing gaps between door and ceiling.
MECHANICAL SYSTEM
16-gauge galvanized steel mounting/plaster frame with integral yoke to retain optical system. Maximum 1-1/4” ceiling thickness.
16-gauge galvanized steel mounting bars with continuous 4” vertical adjust­ment are shipped pre-installed. Post installation adjustment possible without the use of tools from above or below ceiling.
Galvanized steel junction box with hinged access covers and spring latch. Two combination 1/2”–3/4” and three 1/2” knockouts for straight-through conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors, rated for 90°C.
EXAMPLE: LGF 2/26TRT 10RW T73 MVOLT
ELECTRICAL SYSTEM
Galvanized steel lampholder housing.
Horizontally-mounted, four-pin, positive-latch, thermoplastic socket(s).
Class P, thermally-protected, high power factor, electronic ballast(s) mounted to the junction box.
LISTING
Fixtures are UL Listed for thru-branch wiring, non-IC recessed mounting and wet locations. Listed and labeled to comply with Canadian standards.
WARRANTY
1-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Number of lamps/ Wattage/Lamp Door frame Lens type Voltage Ballast
LGF 1
18TRT
1
2 3
26TRT 32TRT 42TRT 57TRT
2
10RW Regressed
white door
10SB Stepped
black baffle
T73 Tempered prismatic lens FFL Flat fresnel lens FOL Flat opal lens
MVOLT 120 277 347
3
ECOS EcoSystem electronic dimming ballast.
ADEZ
ADZT
Minimum dimming level 5%.
4,5
Advance Mark X® electronic dimming ballast. Minimum dimming level 5%
5
Advance Mark VII™ electronic dimming ballast
Options
CP Chicago plenum
6
TRDA RRL
Tamper resistant door assembly
5,7,8
RELOC®-ready luminaire. Provides compatibility with Lithonia RELOC system. Access
above ceiling required.
DS
Dual Switching
GMF Single, slow-blow fuse (not available with MVOLT) GLR Single, fast-blow fuse (not available with MVOLT) WLP Lamp (shipped separately)
ACCESSORIES order as separate catalog numbers (shipped separately)
SCA10
LGF-10-ROUND-LENS
PAGE 1 OF 3
Sloped ceiling adapter. Degree of slope must be specified (10D, 15D, 20D, 25D, 30D). Ex: SCA10 10D.
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2005-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 10/02/13. Specifications subject to change without notice.
RIF Radio interference filter
9
QDS ELR ELRSD
Quick Disconnect System for easy ballast replacement
10
Emergency battery pack. Remote test switch provided
10
High lumen output emergency battery pack. Remote test switch and self­diagnostics module provided
GSKT Foam gasketing ships uninstalled NEPP
Interface for Sensor Switch® nLight® network with integral power supply. Refer to TN-623-01.
Page 2
10” LGF
(45.1)
Overlap Trim:11-1/8 (28.3)
Round Lens
Wet Location, Horizontal Triple-Tube Lamp
DIMENSIONAL DATA NOTES
All dimensions are inches (centimeters) unless otherwise noted.
8-5/8
(21.9)
17-1/4 (43.8)
Aperture: 9-3/4 (24.8) Ceiling Opening: 10-1/2 (26.7)
17-3/4
ORDERING NOTES
1. Will also operate 26DTT 4-PIN lamp.
2. Not available in 3 lamp configurations.
3. Multi-volt electronic ballast capable of operating on any voltage from 120V through 277V, 50 or 60 Hz.
4. Not available with MVOLT.
5. Not available with 347V.
6. Uses Torx T15 rejection pin drive system.
7. Not available with 57TRT.
8. For compatible RELOC systems, refer to TECH-110.
9. Not available with ELR option.
10. For dimensional changes refer to TECH-140. For 57W and 70W consult factory.
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2005-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 10/02/13. Specifications subject to change without notice.
LGF-10-ROUND-LENS
PAGE 2 OF 3
Page 3
10” LGF
90°
1200
1600
2000
1200
1600
2000
90°
120
160
200
1200
1600
2000
Round Lens
Wet Location, Horizontal Triple-Tube Lamp
PHOTOMETRY
Distribution Curve Distribution Data Output Data Coefficient of Utilization Illuminance: Single Luminaire 30” Above Floor
LGF 2/42TRT 10RW T73
80°
400
800
0° 10° 20° 30°
70°
60°
50°
40°
LGF 2/42TRT 10RW FFL
90°
80°
400
800
0° 10° 20° 30°
70°
60°
50°
40°
42TRT LAMP, 1.1 S/MH, 3200 RATED LUMENS, TEST NO. LTL14196
From 0° AveLumens
0
2026
5
2022 1946 1712 1261
744 353 160
55 13
0
192 547 782 784 575 323 161
62 15
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
1521.9
0° - 30°
2305.9
0° - 40°
3204.0
0° - 60°
3443.0
0° - 90°
90° - 180°
0° - 180°
0.0
3443.0
*E fficiency
*53.8
23.8
36.0
50.1
53.8
0.0
pf pc
80% 70% 50%
pw
50% 30% 50% 30% 50% 30%
1
.58
2
.52
3
.47
4
.43
5
.39
6
.36
7
.33
8
.31
9
.28
10
.26
42TRT LAMP, 1.1 S/MH, 3200 RATED LUMENS, TEST NO. LTL14197
From 0° AveLumens
0
2183
5
2184 2101 1780 1195
677 366 169
56 13
0
208 589 811 745 527 332 170
63 15
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
1608.2
0° - 30°
2353.3
0° - 40°
3212.3
0° - 60°
3461.3
0° - 90°
90° - 180°
0° - 180°
0.0
3461.3
*54.1
*E fficiency
25.1
36.8
50.2
54.1
0.0
pf pc
80%70% 50%
pw
50% 30% 50%30% 50%30%
1
.58
2
.53
3
.48
4
.44
5
.40
6
.37
7
.34
8
.31
9
.29
10
.27
.56 .50 .44 .39 .35 .32 .29 .27 .25 .23
.57 .50 .44 .40 .36 .32 .30 .27 .25 .23
.57 .51 .47
.42 .39 .36 .33 .30 .28 .26
20%
.57 .52
.47 .43 .39 .36 .33 .31 .29 .27
20%
.55 .49 .43 .39 .35 .32 .29 .27 .24 .23
.56 .49 .44 .39 .35 .32 .29 .27 .25 .23
.55 .50 .45 .41 .38 .35 .32 .30 .28 .26
.55 .50 .46 .42 .38 .35 .33 .30 .28 .26
.53 .47 .42 .38 .34 .31 .29 .26 .24 .22
.54 .48 .43 .38 .35 .32 .29 .27 .25 .23
Mount height
8 10 12 14 16
Mount height
8 10 12 14 16
Inital fc at be am
center
67.0
36.0
22.4
15.3
11.1
Inital fc at be am
center
72.2
38.8
24.2
16.5
12.0
50% be am angle
58.9° fc at
beam
Beam
6.2
8.5
10.7
13.0
15.3
edge
33.5
18.0
11.2
7.7
5.6
diameter
50% be am angle
56.8° fc at
beam
Beam
5.9
edge
diameter
8.1
10.3
12.4
14.6
10% be am angle
Beam
diameter
11.8
16.2
20.5
24.8
29.1
10% be am angle
Beam
diameter
36.1
19.4
12.1
8.3
6.0
94.2°
11.3
15.5
19.6
23.7
27.8
fc at
beam
edge
91.7°
6.7
3.6
2.2
1.5
1.1
beam
fc at
edge
7.2
3.9
2.4
1.7
1.2
LGF 3/42TRT 10RW T73
80°
400
800
0
0
0
0° 10° 20° 30°
70°
60°
50°
40°
LGF 3/42TRT 10RW FFL
90°
80°
400
800
0° 10° 20° 30°
70°
60°
50°
40°
42TRT LAMP, 1.1 S/MH, 3200 RATED LUMENS, TEST NO. LTL14214
From 0° AveLumens
0
2203
5
2194 2086 1823 1350
791 376 169
57 14
0
208 587 834 838 612 343 171
66 16
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
1628.3
0° - 30°
2466.4
0° - 40°
3421.4
0° - 60°
3674.0
0° - 90°
90° - 180°
0° - 180°
0.0
3674.0
*E fficiency
*38.3
17.0
25.7
35.6
38.3
0.0
pf pc pw
1 2 3 4 5 6 7 8 9
10
42TRT LAMP, 1.1 S/MH, 3200 RATED LUMENS, TEST NO. LTL14215
From 0° AveLumens
0
2275
5
2265 2148 1868 1392
783 396 183
61 15
0
215 604 855 860 610 360 184
69 17
15 25 35 45 55 65 75 85 90
Zone Lumens % Lamp
1673.5
0° - 30°
2533.1
0° - 40°
3503.3
0° - 60°
3773.0
0° - 90°
90° - 180°
0° - 180°
0.0
3773.0
*E fficiency
*39.3
17.4
26.4
36.5
39.3
0.0
pf pc pw
1 2 3 4 5 6 7 8 9
10
PHOTOMETRY NOTES
Tested to current IES and NEMA standards under stabilized laboratory conditions.
Actual performance may differ as a result of end-user environment and application.
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
LGF-10-ROUND-LENS
PAGE 3 OF 3
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2005-2013 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 10/02/13. Specifications subject to change without notice.
.40 .35 .31 .28 .25 .23 .21 .19 .17 .16
.41 .36 .32 .29 .26 .23 .21 .20 .18 .17
.40 .37 .33
.30 .28 .25 .23 .22 .20 .19
.42 .38
.34 .31 .28 .26 .24 .22 .21 .19
20%
20%
.39 .35 .31 .28 .25 .23 .21 .19 .17 .16
.40 .36 .32 .28 .26 .23 .21 .19 .18 .17
.39 .35 .32 .29 .27 .25 .23 .21 .20 .18
.40 .36 .33 .30 .28 .25 .23 .22 .20 .19
.38 .34 .30 .27 .24 .22 .20 .19 .17 .16
.39 .35 .31 .28 .25 .23 .21 .19 .18 .16
80% 70% 50%
50% 30% 50% 30% 50% 30%
.41 .37 .34 .31 .28 .26 .24 .22 .20 .19
80%70% 50%
50%30% 50%30% 50%30%
.42 .38 .35 .31 .29 .26 .24 .22 .21 .19
Mount height
8 10 12 14 16
Mount height
8 10 12 14 16
Inital fc
at be am
center
72.8
39.2
24.4
16.7
12.1
Inital fc at be am
center
75.2
40.4
25.2
17.2
12.5
50% be am angle
58.2° fc at
beam
Beam
diameter
diameter
edge
36.4
6.1
19.6
8.4
10.6
12.2
8.3
12.8
6.0
15.0
50% be am angle
58.0° fc at
Beam
beam
edge
37.6
6.1
20.2
8.3
12.6
10.5
8.6
12.8
6.2
15.0
10% be am angle
93.9° fc at
beam
Beam
diameter
diameter
edge
7.3
11.8
3.9
16.1
2.4
20.3
24.6
1.7
1.2
28.9
10% be am angle
93.3° fc at
beam
Beam
edge
7.5
11.7
4.0
15.9
2.5
20.1
1.7
24.4
1.2
28.6
Loading...