Gotham 10 AFW SpecSheet

Luminaire Type: Catalog Number (autopopulated):
Gotham Architectural Downlighting Compact Fluorescent Downlights
10” AFW
Open Wallwash
Horizontal Lamp Triple-Tube
FEAT URES ORDERING INFORMATION
OPTICAL SYSTEM
Self-flanged, semi-specular or matte-diffuse reflector. Fluted vertical upper section works in conjunction with patented Bounding Ray™ Optical Principle to provide lamp before lamp image and smooth transition from top of reflector to bottom. Hybrid kicker reflector for wallwash. Minimum flange matches reflector finish. White painted flange optional.
Hybrid kicker reflector has highly specular finish on bottom 3/4” and transitions to diffuse on the rest of the kicker reflector.
Hinged lampdoor seals upper trim for optimal fixture efficiency and the reduc­tion of stray light in the plenum.
MECHANICAL SYSTEM
16-gauge galvanized steel mounting/plaster frame with integral yoke to retain optical system. Maximum 1-1/2” ceiling thickness.
16-gauge galvanized steel mounting bars with continuous 4” vertical adjust­ment are shipped pre-installed. Post-installation adjustment possible without the use of tools from above or below the ceiling.
Galvanized steel junction box with bottom-hinged access covers and spring
EXAMPLE: AFW 3/42TRT 10AR MVOLT
latches. Two combination 1/2”–3/4” and three 1/2” knockouts for straight­through conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors, rated for 90°C.
ELECTRICAL SYSTEM
Horizontally mounted, four-pin, positive-latch, thermoplastic socket(s).
Class P, thermally protected high-power-factor electronic ballast(s) mounted to the junction box (CP and EL ballast mounted on ballast tray).
SIMPLY5™ technology available.
LISTING
Fixtures are UL listed for thru-branch wiring, recessed mounting and damp locations. Listed and labeled to comply with Canadian standards (see Options).
WARRANTY
1-year limited warranty. Complete warranty terms located at
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Series Wattage/Lamp Aperture/Trim color Finish Lens type Voltage Ballast
AFW 1/18TRT
1/26TRT 1/32TRT 1/42TRT 1/57TRT 2/18TRT
10AR Clear 10PR Pewter 10WTR Wheat
2
1
10CR
10GR
2
Champagne gold Gold
(blank) Semi-specular LD Matte-diffuse
(blank) No lens
CGL Clear glass lens PCL Clear polycarbonate
lens
MVOLT 120 277 347
3
(blank) GEB10 standard. Electronic ballast.
ECOS
ADEZ
2/26TRT 2/32TRT 2/42TRT 2/57TRT
1
ADZT
3/18TRT 3/26TRT 3/32TRT 3/42TRT
Requires four-pin lamp
3, 4
Lutron® EcoSystem® electronic dimming ballast. Minimum dimming level 5%
5
Advance Mark 10® electronic dim­ming ballast. Minimum dimming level 5%
5
Advance Mark 7® electronic dimming ballast. Minimum dimming level 5%
Options
WLP 3500 K lamp (shipped separately) TRW White painted flange
5,6
ELR GMF RIF Radio Interference Filter RRL
Emergency battery pack with remote test switch
5
Single, slow-blow fuse (not available with MVOLT)
7
RELOC®-ready luminaire. Provides compatibility with Lithonia RELOC system. Access above ceiling required.
HW Hardwire for S5 system; replaces RELOC
AFW-10-OPEN-TRT
PAGE 1 OF 4
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2003-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/14. Specifications subject to change without notice.
8
QDS
Quick disconnect for easy ballast replacement
CWW Corner wallwash DWW Double wallwash
8
CP
Chicago plenum (consult factory)
CSA CSA certified NEPP
®
WRL
Interface for Sensor Switch® nLight® network with integral power supply. Refer to
TN-623-01.
9
Wattage restriction label
WL Wet location; lens required
10” AFW
(44.5)
)
Overlap Trim: 11-1/8 (28.3)
Open Wallwash
Horizontal Lamp, Triple-Tube
DIMENSIONAL DATA NOTES
All dimensions are inches (centimeters) unless otherwise noted.
9-3/4 (24.8)
17-3/16 (43.7
Aperture: 9-3/4 (24.8) Ceiling Opening: 10-1/2 (26.7)
17-1/2
ENERGY
LER.DOL Annual Lamps Lamp Ballast Input
Calculated in accordance with NEMA standard LE-5.
Energy Cost Lumens Factor Watts
40 $5.94 3/42TRT 9600 .98 135
ORDERING NOTES
1. For use with Sylvania lamps only
2. Not recommended for use with compact fluorescent lamp. Consult factory.
3. Multi-volt electronic ballast capable of operating on any voltage from 120V through 277V, 50 or 60 Hz.
4. Not available with 57W.
5. Consult factory for specific availability.
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2003-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/14. Specifications subject to change without notice.
6. For dimensional changes, refer to TECH-140.
7. For compatible RELOC systems, refer to TECH-110.
8. Not available with emergency options.
9. Must specify wattage. Ex.: WRL32
AFW-10-OPEN-TRT
PAGE 2 OF 4
room
wall
10” AFW
AFW 2/32TRT 10AR
(2) 2400 Test
Vertical Plane angle
95° 000000000
AFW 2/42TRT 10AR
(2) 3200 Test
Vertical Plane angle
95° 000000000
AFW 3/32TRT 10AR
(3) 2400 Test
Vertical Plane angle
95° 000000000
Open Wallwash
Horizontal Lamp, Triple-Tube
PHOTOMETRY
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not more than distance to wall) for best results.
Fixture/Lamp Candlepower Data Footcandle values
157
1
2
135
0
0
0
112
1
2
1
67
0
90
0
1
22
2
0
45
0
2
CF32DT/E/IN/835 lamp
total rated lumens no. LTL9680
CF42DT/E/IN/835 lamp
total rated lumens no. LTL9681
CF32DT/E/IN/835 lamp
total rated lumens no. LTL9677
angle
Room side Wall side
Room 157½°135° 112½° 90° 67½° 45° 22½° Wall
0° 1223 1223 1223 1223 1223 1223 1223 1223 1223
5° 1662 1581 1453 1330 1261 1247 1304 1331 1333 15° 2091 2112 1959 1623 1402 143314711371 1307 25° 1951 1980 1984 1772 1490 142614121250 1131 35° 1555 1536 1450 1291 1096 106911811188 1199 45° 971 951 899 799 687 765 970 10761124 55° 49 50 45 39 50 223 495640 717 65° 10 10 10 10 19 100 230283 288 75° 5555733779098 85° 0011136812
angle
Room side Wall side
Room 157½°135° 112½° 90° 67½° 45° 22½° Wall
0° 1555 1555 1555 1555 1555 1555 1555 1555 1555
5° 2017 1948 1840 1693 1580 1548 1587 1621 1624 15° 2523 2587 2395 2059 1728 170417561708 1648 25° 2242 2328 2346 2157 1740 167617111559 1439 35° 1398 1453 1440 1357 1358 164318341937 1963 45° 1140 1105 1029 933 752 881 1109 1261 1306 55° 59 64 60 54 63 277 585781 883 65° 13 13 13 13 25 128 283350 361 75° 888810 44 98 113 121 85° 01223691115
angle
0° 1829 1829 1829 1829 1829 1829 1829 1829 1829
5° 2008 2022 2014 1928 1827 1782 1762 1722 1709 15° 2499 2427 2355 2200 1977 183517221741 1731 25° 2508 2415 2259 2069 1788 173516751678 1630 35° 1781 1757 1685 1547 1318 126213811492 1574 45° 982 969 925 857 721 709 945 11751332 55° 65 72 64 61 79 283 499693 758 65° 11 11 11 12 31 164 279316 321 75° 766711 60 99 111 119 85° 00112914 11 17
Room side Wall side
Room 157½°135° 112½° 90° 67½° 45° 22½° Wall
Luminaire 3' from wall Luminaire 3' from wall
on 3' centers on 4' centers
119161916117 2554856463221 3676968544933 4585659424335 5404442333327 6313433242621 7252627192217 8192121161715 9161717131412
10 13 14 14 11 11 10
Luminaire 3' from wall Luminaire 3' from wall
on 3' centers on 4' centers
123202320139 2685969583926 3788379635839 4676868495241 5485450394133 6394241293327 7313234242621 8242626202118 9202121161714
10 16 17 17 13 14 12
Luminaire 3' from wall Luminaire 3' from wall
on 3' centers on 4' centers
1222023191319 2615562513751 3757277634864 4656566494850 5505352404041 6394141303231 7313233242525 8242626202021 9192121161717
10 16 17 17 13 14 14
PHOTOMETRY NOTES
Tested to current IES and NEMA standards under stabilized laboratory conditions.
Actual performance may differ as a result of end-user environment and application.
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
AFW-10-OPEN-TRT
PAGE 3 OF 4
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2003-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/14. Specifications subject to change without notice.
room
wall
10” AFW
AFW 3/42TRT 10AR
(3) 3200 Test
Vertical Plane angle
95° 000000000
Open Wallwash
Horizontal Lamp, Triple-Tube
PHOTOMETRY
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not more than distance to wall) for best results.
Fixture/Lamp Candlepower Data Footcandle values
157
1
2
135
0
0
0
112
1
2
1
67
0
90
0
1
22
2
0
45
0
2
CF42DT/E/IN/835 lamp
total rated lumens no. LTL9676
angle
Room side Wall side
Room 157½°135° 112½° 90° 67½° 45° 22½° Wall
0° 2756 2756 2756 2756 2756 2756 2756 2756 2756 5° 3123 3090 3012 2905 2760 2686 2657 2621 2601 15° 3818 3779 3597 3319 2876 270426102594 2567 25° 3737 3726 3462 3077 2501 243423422326 2229 35° 2859 2855 2683 2405 2085 199120112043 2029 45° 1488 1488 1439 1321 1182 125815241763 1827 55° 72 75 71 66 109 486 863 1140 1269 65° 17 18 18 19 48 256 457546 558 75° 11 11 11 12 17 86 163 190 207 85° 1122312211726
Luminaire 3' from wall Luminaire 3' from wall
on 3' centers on 4' centers
1383439322232 2103 93 104866287 3112113113 90 78 91 4929494687369 5737675585859 6576060454645 7454748363837 8353838293031 9283131242525
10 23 25 25 19 21 21
PHOTOMETRY NOTES
Tested to current IES and NEMA standards under stabilized laboratory conditions.
Actual performance may differ as a result of end-user environment and application.
Consult factory or IES file for microgroove baffle, black cone or other photometric reports.
GOTHAM ARCHITECTURAL DOWNLIGHTING | 1400 Lester Road Conyers GA 30012 | P 800.315.4982 | gothamlighting.com
© 2003-2014 Acuity Brands Lighting, Inc. All Rights Reserved. Rev. 01/08/14. Specifications subject to change without notice.
AFW-10-OPEN-TRT
PAGE 4 OF 4
Loading...