• Self-flanged, semi-specular or matte-diffuse reflector. Fluted vertical upper
section works in conjunction with patented Bounding Ray™ Optical Principle to
provide lamp before lamp image and smooth transition from top of reflector to
bottom. Hybrid kicker reflector for wallwash. Minimum flange matches reflector
finish. White painted flange optional.
• Hybrid kicker reflector has highly specular finish on bottom 3/4” and transitions
to diffuse on the rest of the kicker reflector.
• Hinged lampdoor seals upper trim for optimal fixture efficiency and the reduction of stray light in the plenum.
MECHANICAL SYSTEM
• 16-gauge galvanized steel mounting/plaster frame with integral yoke to retain
optical system. Maximum 1-1/2” ceiling thickness.
• 16-gauge galvanized steel mounting bars with continuous 4” vertical adjustment are shipped pre-installed. Post-installation adjustment possible without
the use of tools from above or below the ceiling.
• Galvanized steel junction box with bottom-hinged access covers and spring
EXAMPLE: AFW 3/42TRT 10AR MVOLT
latches. Two combination 1/2”–3/4” and three 1/2” knockouts for straightthrough conduit runs. Capacity: 8 (4 in, 4 out) No. 12 AWG conductors, rated
for 90°C.
• Class P, thermally protected high-power-factor electronic ballast(s) mounted to
the junction box (CP and EL ballast mounted on ballast tray).
• SIMPLY5™ technology available.
LISTING
• Fixtures are UL listed for thru-branch wiring, recessed mounting and damp
locations. Listed and labeled to comply with Canadian standards (see Options).
WARRANTY
• 1-year limited warranty. Complete warranty terms located at
7. For compatible RELOC systems, refer to TECH-110.
8. Not available with emergency options.
9. Must specify wattage. Ex.: WRL32
AFW-10-OPEN-TRT
PAGE 2 OF 4
room
wall
10” AFW
AFW 2/32TRT 10AR
(2)
2400
Test
VerticalPlane angle
95°000000000
AFW 2/42TRT 10AR
(2)
3200
Test
VerticalPlane angle
95°000000000
AFW 3/32TRT 10AR
(3)
2400
Test
VerticalPlane angle
95°000000000
Open Wallwash
Horizontal Lamp, Triple-Tube
PHOTOMETRY
TECHNICAL INFORMATION
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.
Footcandle values are initial and tables are based on minimum of six units. For fixture-to-wall
distance other than those shown, use maximum of one-to-one spacing (distance between fixtures not
more than distance to wall) for best results.