GOSSEN METRAWATT METRISO 1000A User Manual

METRISO®1000A Insulation Tester
Nominal voltages: 50 V, 100 V, 250 V, 500 V und 1000 V
Quick testing with signal lamp
Low impedance measurement 0 ... 4 Ω
• Voltage measurement up to 1000 V
3-348-807-03
7/6.06
Nominal voltages 50 V, 100 V, 250 V, 500 V and 1000 V
Quick testing with signal lamp
The signal lamp in the test prod serves to illuminate the work area, and also indicates an evaluation of the insulation resistance as OK or Failure. As long as this lamp is lit, the minimum values for insu­lation resistance per VDE 0100 have been met.
Low impedance measurement 0 ... 4 Ω
Low impedance measurement in accordance with VDE 0413, Part 4 is also possible.
Voltage measurement to 1000 V
The instrument is also equipped with a 1000 V measuring range for direct and alternating current. This is especially advantageous for the testing of devices for the absence of voltage, and the dis­charge of capacitive devices under test.
Minimal use of batteries
Measurement only occurs when the ON/OFF button is depressed. This provides for long service life of the batteries.
Dial gauge with signal lamp
The condition of the batteries is indicated by the color of the sig­nal lamp at the left side of the dial gauge. This lamp also serves to indicate that the instrument is switched on.
Applicable regulations and standards
IEC 61010-1 EN 61010-1 VDE 0411-1
EN 61557 VDE 0413
Part 1 Part 2 Part 4
DIN EN 61326 VDE 0843 Part 20
EN 60529 DIN VDE 0470 Part 1
DINEN60051 Direct-acting and direct-display electrical measuring
Safety regulations for electrical measuring, control and laboratory equipment – General requirements
Measuring and monitoring instruments for the testing of electrical safety in systems with nominal voltages of up to 1000 V AC and 1500 V DC General requirements Insulation resistance measuring instruments Resistance measuring instruments
Electrical equipment for measurement, control and laboratory use – EMC requirements
Test instruments and test procedures – Degree of protection provided by enclosures (IP code)
instruments and their accessories
GMC-I Gossen-Metrawatt GmbH
METRISO®1000A Insulation Tester
Technical Data
rdg.
rdg.
rdg.
rdg.
rdg.
rdg.
Nominal
Voltage
2)
50 V
100 V 120 V
250 V 300 V
500 V 600 V
1000 V 1200 V
Measuring
Function
1000 V 0 ... 1000 V ± 2.5 %
R1, R2, R3
U
= 50 V
N
R1, R2, R3
U
= 100 V
N
R1, R2, R3
U
= 250 V
N
R1, R2, R3
= 500 V
U
N
R1, R2, R3
U
= 1000 V
N
4 Ω 0 ... 4 Ω± 1.5 %
1)
)
As related to scale length
Scale lengths: R1 l = 46 mm
2)
Within the marked area of the respective scale (nominal range of use)
Measuring Range
0 ... 40 kΩ
200 kΩ ... 20 MΩ 40 kΩ
0 ... 80 kΩ
400 kΩ ... 40 MΩ 80 kΩ
0 ... 200 kΩ
1 MΩ ... 100 MΩ 200 kΩ
0 ... 400 kΩ
2 MΩ ... 200 MΩ 400 kΩ
0 ... 0.8 MΩ
4 MΩ ... 400 MΩ 800 kΩ
R2 l = 71 mm R3 l = 80 mm Ω l = 67 mm U l = 66 mm
Inherent Devia-
tion at Reference
Conditions
1)
± 1.5 %
± 1.5 %
± 1.5 %
± 1.5 %
± 1.5 %
Measuring
Error
±25%
±25%
±25%
±25%
±25%
±10%
Nominal/
Measuring
U
—I
Current
N
1.0 mA
I
N
200 mA 9 V > 200 mA 0,315 A
m
Turn-on performance for insulation resistance measurement
An electronic voltage limiter prevents the voltage at the device under test from substantially exceeding nominal voltage at turn­on (see following characteristic curves).
Open­circuit
Voltage
U
o
60 V
Fre-
quency/
Short­circuit
Current I
DC /
40 ... 200 Hz900 kΩ 1200 V
<12mA
Resistance
k
Internal
R
i
30 kΩ
60 kΩ
150 kΩ
300 kΩ
600 kΩ
Switching Value
for Resistance
> 100 kΩ 1200 V max. 10 s20 kΩ ... 1 MΩ 10 kΩ
> 200 kΩ 1200 V max. 10 s40 kΩ ... 2 MΩ 20 kΩ
> 500 kΩ 1200 V max. 10 s100 kΩ ... 5 MΩ 50 kΩ
> 1 MΩ 1200 V max. 10 s200 kΩ ...10 MΩ 100 kΩ
> 2 MΩ 1200 V max. 10 s400 kΩ ... 20 MΩ 200 kΩ
Overload Capacity
Value Duration
continu-
ous
continu-
ous
Accuracy
Insulation resistance Class 1.5 in reference to scale length
after electrical zero balance
Direct and alternating current class 2.5
Display
Movement Moving coil with core magnet
Ux [V]
500
400
300
200
100
Ux [V]
600
500
400
300
200
100
Range R1
UN= 500 V
0
500
1000
Rx
[kΩ]
Ux [V]
600
500
Rx [MΩ]
400
300
200
100
0
Range R2
UN= 500 V
0
0,5
2
1,5
1
Range R3
UN=500V
Rx [MΩ]
2 GMC-I Gossen-Metrawatt GmbH
Loading...
+ 2 hidden pages