Gossen MetraWatt METRATHERM Operating Instructions Manual

METRATHERM1
Portable Infrared Thermometer
3-349-386-15
2/4.10
Operating Instructions
2 GMC-I Messtechnik GmbH
1 Product Description ...................................................................3
2 Safety Warnings .........................................................................5
3 Instrument Overview ..................................................................6
4 Temperature Measurement .......................................................8
4.1 Measurement with Infrared Sensor ............................................................8
4.1.1 Standard Measurements .......................................................................8
4.1.2 Special Functions .................................................................................9
4.1.3 Memory Functions ..............................................................................10
4.2 Thermocouple Measurements – TC Function ............................................11
5
Infrared Thermometer Mode of Operation and Parameters
Configuration ...................................................................................... 12
5.1 Field of Vision Ratio .................................................................................12
5.2 Emissivity – Parameter  
5.3 Temperature Limit Values ........................................................................13
6 Technical Data ........................................................................14
7 Maintenance ............................................................................15
7.1 Unit of Measure and Laser On/Off Switches ..............................................15
7.2 Battery Replacement ...............................................................................15
7.3 Cleaning the Lens ................................................................................... 16
7.4 Cleaning the Housing ..............................................................................16
8 Appendix ..................................................................................16
8.1 Emissivity Table ..................................................................................... 16
8.2 PC Display and Recording Program (data logger) ......................................18
8.2.1 PC System Requirements ....................................................................18
8.2.2 Installation .........................................................................................18
8.2.3 Starting the Application Software .........................................................19
8.2.4 Recording Measurement Data – Data Logger Function .........................20
9 Product Support .......................................................................21
10 Repair and Replacement Parts Service
Calibration Center and Rental Instrument Service ...................21
GMC-I Messtechnik GmbH 3
1 Product Description
The METRATHERM1 is a contactless infrared temperature measuring
instrument. It fulfills the requirements of applicable European and national EC directives. This is confirmed by means of the CE mark. A corresponding declaration of conformity can be requested from GMC-I Messtechnik GmbH.
The instrument fulfills the following standards: EN61326: Electrical equipment for control technology and laboratory
use
IEC61000-4-2:
Testing of interference immunity to the discharge of static electricity
IEC61000-4-3:
Testing of interference immunity to high frequency electromagnetic fields
IEC61000-4-8:
Testing of interference immunity to magnetic fields with energy technology frequencies
Product Features
Infrared temperature measuring range: –50 to 1000° C (–58 to 1832° F)
Exact positioning with laser sighting (can be activated if desired)
High D:S ratio of 50:1
Emissivity adjustable from 0.1 to 1.00 in steps of 0.01
Additional measuring option with type K thermocouple
Illuminated LCD panel
Selectable unit of measure: °C or °F
Single and continuous measurements
Storage of current measured temperature, lowest and highest
temperature or maximum temperature difference T
10 memory locations for individual measurements
Alarm function: acoustic signal in the event of violation of adjustable limit values
USB port for data transmission to a PC
PC software for displaying and recording measured values (data logger function) on included CD ROM
4 GMC-I Messtechnik GmbH
Applications
Temperature measurement at large distances, and thus at a safe distance from potential danger zones
Electrical troubleshooting
Automotive repair and maintenance
Air conditioning
Scientific experiments
Manufacturing processes in the field of semiconductor technology
Contacts in electrical switch boxes
Food monitoring and processing
Included
1 METRATHERM1 measuring instrument
19 V battery 1 screw-on carrying strap 1 type K thermocouple 1 USB adapter cable for data transmission to a PC 1 CD ROM with installation software for PC display and
recording program (data logger)
1 set of operating instructions in English and German
GMC-I Messtechnik GmbH 5
2 Safety Warnings
Read the following safety precautions carefully before placing the measuring instrument into service. Repairs and maintenance work which are not described in these operating instructions should only be executed by qualified personnel.
Laser Warning!
Never aim the laser beam directly at the eye! Exercise care with reflective surfaces! Keep the instrument out of the reach of children!
Safety Precautions
Never immerse the instrument in water.
This product is not suitable for medical examinations. When measuring body temperature, the measured value serves as a reference value only. The instrument has been designed for industrial, scientific and technical applications.
Symbols on the Device
Warning concerning a point of danger (attention: observe documentation!)
Laser warning
Indicates EC conformity
The device may not be disposed of with the trash. Further information regarding the WEEE mark can be accessed on the Internet at www.gossenmetrawatt.com by entering the search term WEEE.
!
6 GMC-I Messtechnik GmbH
3 Instrument Overview
Housing
Control Panel
Laser Aperture
Control Panel / Display
Termina ls
Measuring
USB Port
Battery Compartment
Trigger
Thread for Attaching Carrying Strap or Tripod (not included)
Type K Thermocouple
Laser Beam
IR Measuring Window
and Lid
PC Connection
Measuring Function Selection
Continuous Measurement On/Off
Save / Delete
Adjust Parameter Value
°C / °F (selectable)
Max. / Min. / Average Value
Scan / HOLD (single measurement)
Main Temperature Display
Auxiliary Temperature Display
Battery Level
Memory Function
Laser Active
Limit Value Alarm
Temp. Difference T
Acoustic Alarm for Exceeded Limit Value
Parameter Value
Memory Location Selection
Acoustic Alarm On/Off
Adjust Parameter Value Memory Location Selection
Measured Values
Thermocouple (TC)
AUTO (continuous measurement)
Emissivity
Indicates double function
GMC-I Messtechnik GmbH 7
Operating Mode Selection and Parameter Settings
HOLD/SCAN
DATA
MAX
MIN
AVG
T
TC
HAL
LAL
Operating Mode – Selecting Functions
Configuration Mode – Setting Parameters
MODE
Acquire and display temp. during measurement (see chapter 4.1.1 for continuous measurement)
Access stored data with the help of the and
scroll keys (see chapter 4.1.3)
MAXimum temperature during a measuring sequence (see chapter 4.1.2)
MINimum temperature during a measuring sequence (see chapter 4.1.2)
Average temperature during a measuring sequence (see chapter 4.1.2)
Largest temperature difference during a measuring sequence (see chapter 4.1.2)
Measurement with thermocouple (see chapter 4.2)
Adjustable emissivity for increased accuracy with various materials (see chapter 5.2)
Warning signal adjustment for maximum temperature (see chapter 5.3)
Warning signal adjustment for minimum temperature (see chapter 5.3)



Loading...
+ 15 hidden pages