GOSSEN METRAWATT METRAHIT X-TRA, METRAHIT PRO, METRAHIT BASE User Manual

METRAHITX-TRAPROBASE
TRMS Digital Multimeters
• Digital Hand-Held Multimeter with RMS Measurement V
• 4½-place display (11,999 digits), with display illumination
• DKD calibration certificate
METRAHITBASE
• Current measurement via clip-on current sensor: The transformation ratio is adjustable from 1 mV:1 mA to 1 mV:1 A, and is accounted for by the display.
METRAHITX-
Additional “low-resistance” (1 MΩ) alternating voltage measurement
• 1 kHz / -3 dB low-pass filter can be activated
• Direct current measurement from 10 nA to 10 A, and 16 A for short periods
METRAHITX-TRA
Temperature measurement with Pt100(0) resistance thermometer
Broad range capacitance measurement
Frequency and keying ratio measurement at 2 to 5 V signals or up to 1 MHz
• Data memory and internal clock, power pack adapter socket
Bidirectional infrared interface for exchanging data with a PC
AC TRMS
, V
AC+DC TRMS
TRAand METRAHIT⏐PRO
, VDC, Hz (V), Hz (A), Ω, V , °C/°F (TC)
DQS Certified per
DIN EN ISO 9001:2000
reg. no.1262
3-349-350-03
2/3.06
Applications
The multimeter is suitable for universal use in electrical engineering, electrical installation, laboratory applications, telecommunication, training etc.
The instrument can be used in the field and is equipped with internal, mains-independent supply power.
Features
Three Connector Jacks with Automatic Blocking Sockets (ABS) *
All current ranges are implemented via a single connector jack which prevents any possibility of operator error. Beyond this, the automatic blocking sockets prevent incorrect connection of the measurement cables, as well as selection of the wrong measured quantity. Danger to the user, the instrument and the device under test resulting from operator error is thus ruled out.
* Patented (patent no. DE 40 27 801 C2 and US 5,166,599)
Overload Protection
The instrument is safeguarded for up to 1000 V in all measuring functions by overload protection. Voltages of greater than 1000 V and current of greater than 10 or 16 A are indicated acoustically. Dangerous contact voltages are indicated when the 1 kHz low­pass filter is activated. The FUSE display appears at METRAHITX- instruments in order to indicate that the fuse for the current mea­suring input has blown.
TRA and METRAHITPRO
RMS Value with Distorted Waveshape
The utilized measuring method allows for waveshape independent RMS measurement (TRMS AC and AC+DC) for voltage and current (METRAHITX-
TRA up to 20 kHz).
Activatable Filter for V AC Measurement
A 1 kHz low-pass filter can be activated if required, for example when measuring motor voltage at electronic frequency converters. The input signal is checked by a voltage comparator for dangerous voltages as long as the low-pass filter is activated.
Measuring 5 V Square-Wave Signals with the METRAHITX-
TRA
This function makes it possible to test circuits and transmission cables by measuring the frequency and the keying ratio of pulses with amplitudes of 2 to 5 V and frequencies of 100 Hz to 1 MHz.
Analog Scale for Quick Trend Display – Bar Graph or Pointer
The analog scale (with additional negative range for zero­frequency quantities) allows for faster recognition of measured value fluctuation than is possible with a digital display. The instrument can be switched back and forth between bar graph and pointer display.
Automatic or Manual Measuring Range Selection
Measured quantities are selected by means of a rotary switch and a function key. The measuring range is automatically matched to the measured values. The measuring range can also be selected and fixed manually with a key.
GMC-I Gossen-Metrawatt GmbH
METRAHITX-TRA⏐PROBASE
TRMS Digital Multimeters
Fast Acoustic Continuity Test
Testing for short circuiting and interruption is possible with the selector switch in the position. The threshold value for acoustic signaling can be set to 1, 10, 20, 30, 40 or 90 Ω.
Automatic Storage of Measured Values *
The DATA function automatically saves the digitally displayed measured value after settling in. Acoustic signaling is also used to indicate whether the new measured value deviates from the initial reference value by less or more than 0.1% of the measuring range.
* Patented
Storage of Min-Max Values
Comparable to the slave-pointer function of an analog instrument, the device saves the highest and lowest measured values after the MIN/MAX function has been activated or reset. These extreme values can be queried at the display.
Battery Charging Status – Power Saving Circuit
The battery charging status is indicated by means of four sym­bols.
The device is switched off automatically if the measured value remains unchanged for a period of between 10 and 59 minutes (adjustable), and if none of the controls are activated during this time. Automatic shutdown can be deactivated by switching the instrument to continuous operation.
METRAHITX-
TRA: The infrared interface can be switched off in the
standby mode.
Protective Cover for Harsh Conditions
The instrument is protected against damage in the event of impacts or dropping by means of a soft rubber cover with tilt stand and test probe holder. The rubber material also assures that the instrument does not wander if it is set up on a vibrating surface.
Infrared Data Interface with METRAHITX-
TRA
The device can be remote configured, and momentary and stored measurement data can be read out via the bidirectional infrared interface. The USBX-TRA interface adapter and METRAVIEW software are required to this end (see accessories). Interface protocol and device driver software for LabVIEW
®
(National
Instruments™) are available upon request.
Selection List
Function
V AC / Hz (Ri = 10 MΩ) TRMS
V AC (Ri = 1 MΩ) TRMS
V AC+DC (Ri = 10 MΩ) TRMS
V DC (Ri = 10 MΩ)
... 1 MHz 5 V AC
Keying ratio as %
Hz (V AC)
Bandwidth, V AC
A AC / Hz
A AC+DC TRMS
A DC
Fuses
A AC / Hz
A AC+DC
A DC
Hz (A AC)
Clip factor Resistance Ω
Continuity
Diode ... 5.1 V
Temperature TC (K)
Temperature RTD
Capacitance
Min-Max / data hold
4 MBit memory
IR Interface
Power pack adapter socket
Protection
Measuring category
1)
2)
TRMS
1 )
Ri = 1 M
For 15,400 measured values, sampling rate adjustable from 0.1 second to 9 hours IP 65 in preparation
TRMS
TRMS
1)
METRA
HIT⏐X-
TRA
METRAHIT⏐PRO
Filter
1kHz 1kHz
Filter
1kHz 1kHz
•••
•••
——
——
... 100 kHz ... 100 kHz ... 100 kHz
15 Hz ... 20 kHz 15 Hz ... 10 kHz 15 Hz ... 1 kHz
100 μA
1/10/100 mA
1 A / 10 (16) A
10 A / 1000 V 10 A / 1000 V
1)
1)
Ω
—— —— ——
... 30 kHz ... 30 kHz ... 30 kHz
——
•••
•••
•••
•••
——
——
•••
——
——
——
2)
IP 52
1000 V CAT III
600 V CAT IV
1 A / 10 (16) A
IP 52
1000 V CAT III
600 V CAT IV
METRA
Filter
Filter
2)
HIT⏐B
IP 52
1000 V CAT II I
600 V CAT IV
Included
ASE
DKD Calibration Certificate
The multimeters are furnished with an internationally valid DKD calibration certificate (recognized by EA and ILAC). A
fter the specified calibration interval has elapsed (recommended interval: 1 to 3 years), the multimeters can be inexpensively recalibrated in our own DKD calibration laboratory.
1multimeter 1
pair of safety measurement cables (1.5 m) with 4 mm test probes,
1000 V CAT III, 600 V CAT IV (KS17-2) 2 batteries, 1.5 V, type AA 1 condensed operating instructions, English/German 1 CD ROM (operating instructions in English and German),
METRAV
IEW demo software in preparation
1 DKD calibration certificate
Applicable Regulations and Standards
IEC/EN 61010, part 1:2001/VDE 0411-1:2002
DIN EN 61326 VDE 0843, part 20
DIN EN 60529 DIN VDE 0470, part 1
2 GMC-I Gossen-Metrawatt GmbH
Safety requirements for electrical equipment for measurement, control and laboratory use
Electrical equipment for control technology and laboratory use – EMC requirements
Test instruments and test procedures – degrees of protection provided by enclosures (IP code)
1 protective rubber cover (METRA HITX-
TRA only)
Voluntary Manufacturer’s Guarantee
24 months for materials and workmanship 1 to 3 years for calibration (depending upon application)
Characteristic Values
METRAHITX-TRA⏐PROBASE
TRMS Digital Multimeters
Resolution at Upper
Meas.
Function
Hz (A )
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
Measuring Range
100 mV 10 μV11MΩ 11 MΩ // < 50 pF 0.09 + 5 with ZERO 1 + 30 (> 300 d) 1)1 + 30 (> 300 d)
1 V 100 μV11MΩ 11 MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
V
A
X-TRA
PRO
A
BASE
Ω
F
TRA
X-
Hz (V) Hz (A)
Hz (V) Hz (A)
MHz
X-
TRA
%
X-
TRA
°C/°F
Values of less than 200 digits are suppressed in the mV range. 15 (20) ... 45 ... 65 Hz At 0° ... + 40° C Displays up to max. 5.1 V, “OL” in excess of 5.1 V. Applies to measurements at film capacitors Lowest measurable frequency for sinusoidal measuring signals symmetrical to the zero point Overload capacity of the voltage measurement input: power limiting: frequency x voltage max. 3 x 10 Overload capacity of the current measurement input: See current measuring ranges for maximum current values. Input sensitivity, sinusoidal signal, 10% to 100% of the measuring range Plus sensor deviation Residual value deviates within 1 ... 30 d from the zero point due to TRMS con­verter when probe tips are short-circuited
10 V 1 mV 10 MΩ 10 MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
100 V 10 mV 10 MΩ 10 MΩ // < 50 pF 0.05 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
1000 V 100 mV 10 MΩ 10 MΩ // < 50 pF 0.09 + 3 0.5 + 9 (> 200 d) 1 + 30 (> 300 d)
100 μA 10 nA 12 mV 12 mV 0.5 + 5 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
1 mA 100 nA 120 mV 120 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
X-TRA
10 mA 1 μA 16 mV 16 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
100 mA 10 μA 160 mV 160 mV 0.5 + 3 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
1 A 100 μA 40 mV 40 mV 0.9 + 10 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
PRO
METRAHIT
10 A 1 mA 600 mV 600 mV 0.9 + 10 1.5 + 10 (> 200 d) 1.5 + 30 (> 200 d)
Factor: 1:1/10/100/1000
0.1/1/10/100 A 100 mV
1/10/100/1000 A 1 V
10/100/1000/10000 A
100 Ω 10 mΩ < 1.4 V Approx. 300 μA0.2 + 5
1kΩ 100 mΩ < 1.4 V Approx. 250 μA0.2 + 5
10 kΩ 1 Ω < 1.4 V Approx. 100 μA0.2 + 5
100 kΩ 10 Ω < 1.4 V Approx. 12 μA0.2 + 5
1MΩ 100 Ω < 1.4 V Approx. 1.2 μA0.2 + 5 10 MΩ 1kΩ < 1.4 V Approx. 125 nA 0.5 + 10 40 MΩ 10 kΩ < 1.4 V Approx. 20 nA 2.0 + 10
100 Ω —0.1Ω Approx. 8 V Approx. 1 mA const. 1 + 5
3)
5,1 V
10 nF 10 pF 10 MΩ 0.7 V 1 + 6
100 nF 100 pF 1 MΩ 0.7 V 1 + 6
1 μF1nF100kΩ 0.7 V 1 + 6 10 μF10nF12kΩ 0.7 V 1 + 6
100 μF100nF3kΩ 0.7 V 5 + 6
1000 μF1μF3kΩ 0.7 V 5 + 6
100.00 Hz 0.01 Hz
1.0000 kHz 0.1 Hz
10.000 kHz 1 Hz
100.00 kHz 10 Hz 10 Hz
30.00 kHz 10 Hz 10 Hz
100 Hz ... 1 MHz 100 Hz 100 Hz 0.05 + 3 > 2 V ... 5 V
2.0 ... 98 % 0.01% 100 Hz ... 1 kHz 1 Hz 0.1 R > 2 V ... 5 V
5.0 ... 95 % 0.01% ... 10 kHz 1 Hz 0.1 R > 2 V ... 5 V
10 .... 90 % 0.01% ... 100 kHz 1 Hz 0.1 R > 2 V ... 5 V
Pt100
– 200.0 ...
X-TRA
+850.0° C – 150.0 ...
Pt1000
X-TRA
+850.0° C
K
– 250.0 ...
(NiCr-Ni)
+1372.0° C
Range Limit
11,999 1199
Voltage drop, approx. at upper range limit
Input Input impedance
10 V Plus clip-on current sensor error
Open-circuit voltage
1 mV Approx. 8 V Approx. 1 mA const. 0.5 + 3
0.1 °C
... 20 (1) kHz sinusoidal. See influence error on page 4.
Input Impedance
~ /
Voltage measurement input approx. 1 MΩ
Discharge resist. U
6
V x Hz for U > 100 V
(V socket)
Meas. current at
range limit
0 max
5)
f
min
1Hz
±(... % rdg. + ... d) ±(... % rdg. + ... d) ±(... % rdg. + ... d)
±(0.5% rdg. + 10 d)
±(... % rdg. + ... d)
±(... % rdg. + ... d)
±(... % rdg. + ... d)
8)
0.05 + 3
±(... % rdg. + ... d)
0.3 + 15
0.3 + 15
1% + 5 K
Key: R = measuring range, d= digit(s), rdg. = measured value (reading)
Intrinsic Error
under Reference Conditions
10)
~
10)
~
±(1% rdg. + 30 d)
> 300 d
with active ZERO function
4)
with ZERO function active
4)
4)
4)
4)
4)
9)
9)
9)
10)
10)
±(1% rdg. + 30 d)
> 300 d
Overload Capacity
Value Time
1)
1000 V
DC AC
RMS
sine
6)
0.2 A
10 A: 5 min
16 A: 30 s
Measurement input
1000 V RMS Max. 10 s
1000 V
DC AC
RMS
sine
1000 V
DC AC
RMS
sine
Hz (V) 6):
Hz (A )6):
1000 V
7)
Hz (A):
1000 V Max. 10 s
1000 V
DC/AC
RMS Sine
Continu-
ous
Continu-
ous
Max. 10 s
Max. 10 s
Max. 10 s
Max. 10 s
2)
GMC-I Gossen-Metrawatt GmbH 3