• Extended current measurement, METRA HIT 2A: ... 15 A=/~
• Resistance measurement: 1 Ω ... 1 MΩ (4 ranges)
• Capacitance: 200 mF ... 2 µF (4 ranges)
• Level: -15 ... +56 dB (6 ranges)
3-349-304-03
2/7.04
5 Ampere 15 Ampere / Class 2.5
Broad Range of Applications
A large number of measuring ranges allows for universal use of
the instruments, for example in electronics, digital technology and
a wide variety of general electrical applications.
Safety Features
The connector jacks and plugs included with the measurement
cables which are available as accessories are protected against
inadvertent contact.
Measuring Range Selector Switch
All measuring ranges are selected with a rotary switch.
Rugged Mechanical Design
The rugged plastic housing and the spring loaded bearing jewels
in the moving-coil mechanism protect the instrument from
damage due to mechanical stressing. Especially effective
protection is provided by the protective rubber cover and the
ever-ready case, both of which are available as accessories.
Applicable Regulations and Standards
IEC/EN 61010-1:2001/
VDE 0411-1:2002
EN 60529
VDE 0470, part 1
DIN EN 61326
VDE 0843, part 20
Safety requirements for electrical equipment for
measurement, control and laboratory use
Test instruments and test procedures,
degrees of protection provided by enclosures (IP code)
Electrical equipment for control technology and
laboratory use – EMC requirements
500 V CAT II
IEC/EN 61010-1, Second Edition
Characteristic Values
Voltage Measuring Ranges
VoltageOutput
0.15 V —3.15 kΩ—
0.50 V —10.00 kΩ—
1.50 V -15 ... + 6 dB31.50 kΩ6.50 kΩ
5.00 V - 5 ... + 16 dB100.00 kΩ20.00 kΩ
15.00 V + 5 ... + 26 dB315.00 kΩ65.00 kΩ
50.00 V +15 ... + 36 dB1.00 MΩ200.00 kΩ
150.00 V +25 ... + 46 dB3.15 MΩ650.00 kΩ
500.00 V +35 ... + 56 dB10.00 MΩ2.00 MΩ
1)
0 dB 0.775 V in the 1.5 V range, 0 dB 1 mW to 600 Ω
Voltage related input resistance: for : 20.0 kΩ/V
1)
METRA HIT 1A: Current Measuring Ranges
Current
50.00 µA 0.158 V—
0.50 mA 1.15 V1.00 V
5.00 mA 1.25 V1.25 V
50.00 mA 1.25 V1.25 V
500.00 mA 1.85 V1.85 V
5000.00 mA 1.73 V1.73 V
Voltage Drop, Approx.
Internal Resistance, Approx.
for : 4.0 kΩ/V
GOSSEN METRAWATT GMBH
METRA HIT 1A and METRA HIT 2A
Analog Multimeters
METRA HIT 2A: Current Measuring Ranges
Current
50 µA 0.158 V—
1.5 mA 1.16 V1.21 V
15 mA 1.25 V1.25 V
150 mA 1.25 V1.25 V
1.5 A 1.95 V1.95 V
15 A 0.43 V0.49 V
Voltage Drop, Approx.
Resistance Measuring Ranges
ResistanceScale Span
Value at Scale
Middle (R
Ω x 11 Ω ... 1 kΩ18.00 Ω83 mA
Ω x 1010 Ω ... 10 kΩ180.00 Ω 8.3 mA
Ω x 100100Ω ... 100 kΩ1.8 0 kΩ0.83 mA
Ω x 10001kΩ ... 1 MΩ18.00 kΩ0.083 mA
2)
At a battery voltage of 1.5 V
)
i
Max. Measuring
max
Approx.
2),
Current I
Capacitance Measuring Ranges
Capacitance
3)
µF x 10002000 ... 200 000 µF
µF x 100200 ... 20000 µF
µF x 1020 ... 2000 µF
µF x 12 ...200 µF
3)
Rough measurements in the resistance measuring ranges, determination
of measured values with comparative scale
Scale Span
Reference Conditions
Ambient temperature
+23°C ±2K
Normal position
of useHorizontal
Frequency40 ... 60 Hz
Line VoltageFor : sinusoidal
Relative humidity40 ... 60%
The instrument is equipped with half-wave rectification and is
RMS calibrated. It evaluates the arithmetic mean value of a
half-wave and displays different values for pulsating voltage and
current depending upon polarity.
Other influencing quantities:per IEC/EN 60 051
Ambient Conditions
Storage temp. range -25 to 65° C (without battery)
Relative humidity
Up to 75%, no condensation allowed
METRA HIT 2A: Accuracy (under reference conditions per IEC/EN 60 051)
Class 2.5 for and , max. additional intrinsic error in the 15 A
range: ±2%; in the 1.5 V~ range: +1/–2,5%,
class 2.5 for Ω (error relative to 52 mm scale length)
METRA HIT 2A: A
dditional accuracy class influence and Nominal Ranges of Use
Battery for resistance
measurementOne 1.5 V mignon cell per IEC LR6/R6
(size AA), leak-proof
Electrical Safety
Safety classII per IEC/EN 61010-1:2001/
VDE 0411-1:2002
Measuring categoryII
Nominal voltage500 V
Test voltage3.5 kV~
Fouling factor2
Fuse linksReplaceable
METRA HIT 1A
:
F1: FF630mA/700V AC (50 kA), 6.3 x 32
F2: FF6.3A/500V AC (50 kA), 6.3 x 32
METRA HIT 2A
:
F1: FF1.6A/700V AC (50 kA), 6.3 x 32
F2: FF16A/500V AC (50 kA), 6.3 x 32
Soldered permanently into place
750 mA / 600 V AC
METRA HIT 1A: Overload Capacity
Range ToRange To
0.15V –
0.5V –
1.5V –
5.0V –
15.0V –
50.0V –
150.0V –
500.0V –
50.0 µA –
0.5 mA –
5.0 mA –
50.0 mA –
500.0 mA –
5000.0 mA –
20 V
50 V
100 V
150 V
250 V
250 V
300 V
500 V
1.0 mA
5.0 mA
10.0 mA
70.0 mA
500.0 mA
3.0 A
5.0 A
1)
2)
2)
2)
2)
2)
2)
2)
3)
—
—
1.5 V
5.0 V
15.0 V
50.0 V
150.0 V
500.0 V
—
0.5 mA
5.0 mA
50.0 mA
500.0 mA
5000.0 mA
500.0 mA
METRA HIT 2A: Overload Capacity
Range ToRange To
0.15V –
0.5V –
1.5V –
5.0V –
15.0V –
50.0V –
150.0V –
500.0V –
50 µA –
1.5 mA –
15 mA –
150 mA –
:
1.5A –
15A –
1)
Fuse F1 blows in the event of overloading.
2)
Ranges are protected against overloading with PTC resistor
3)
Max. 1 minute
20 V
50 V
100 V
150 V
250 V
250 V
300 V
500 V
1.0 mA
5.0 mA
20.0 mA
150.0 mA
1.2 A
1.5 A
12.0 A
15.0 A
1)
2)
2)
2)
2)
2)
2)
2)
3)
3)
—
—
1.5 V
5.0 V
15.0 V
50.0 V
150.0 V
500.0 V
—
1.5 mA
15 mA
150 mA
1.5 A
15 A
150.0 mA
—
—
25 V
50 V
150 V
250 V
300 V
500 V
—
5.0 mA
10.0 mA
70.0 mA
3.0 A
5.0 A
—
—
25 V
50 V
150 V
250 V
300 V
500 V
—
5.0 mA
20.0 mA
1.2 A
1.5 A
12.0 A
15.0 A
2)
2)
2)
2)
2)
2)
3)
2)
2)
2)
2)
2)
2)
3)
3)
2GOSSEN METRAWATT GMBH
METRA HIT 1A and METRA HIT 2A
Analog Multimeters
Electromagnetic Compatibility (EMC)
Interference emission EN 61326:2002 class B
Interference immunity EN 61326:2002
IEC 61000-4-2:
8 kV atmospheric
discharge
IEC 61000-4-3:
3 V/m
Mechanical Design
Scale lengthA, V – 0 ... 5.0: approx. 83 mm
A, V – 0 ...15.8: approx. 77 mm
A, V~0 ... 5.0: approx. 67 mm
A, V~ 0 ... 15.8: approx. 59 mm
Ω∞... 0: approx. 52 mm
dB – 15 ... + 6: approx. 42 mm
Dimensions92 x 126 x 45 mm
WeightApprox. 0.3 kg without battery
ProtectionHousing: IP 40, terminals: IP 20 per
EN 60529/VDE 0470, part 1
Table Excerpt Regarding Significance of the IP Code
st
(1
IP XY
digit, X)
Protection against pene-
tration of solid particles
0Not protected0Not protected
1≥ 50.0 mm dia.
2≥ 12.5 mm dia.
3≥ 2.5 mm dia.
4≥ 1.0 mm dia.
5Dust protected5Jet-water
6Dust-proof6Powerful water jets
IP XY
(2nd digit, Y)
Protection against pene-
tration by water
1Vertical dripping
2Dripping (15° inclination)
3Spray water
4Splashing water
Standard Equipment
1 analog multimeter (without battery or cable set)
1 set operating instructions
Order Information
DescriptionTypeArticle Number
Analog multimeter, 5 A / 500 VMETRA HIT 1AM100A
Analog multimeter, 15 A / 500 VMETRA HIT 2AM101A
Cable set consisting of 1 pair KS17-2GTY 3620 034 P0002
Ever-ready caseF809GTY 3172 083 P01
Protective rubber coverGH185GTY 3171 185 P01
Current measuring adapter for safe,
trouble-free measurement of current
consumption via the mains plug of
connected power consumersSM16GTM 9070190E0002
F1 fuse link (shipped in package of
ten) for METRAHIT 1AFF 630 mA / 700 VZ109J
F2 fuse link (shipped in package of
10) for METRAHIT 1AFF 6.3 A / 500 VZ109K
F1 fuse link (shipped in package of
10) for METRAHIT 2A
F2 fuse link (shipped in package of
10) for METRAHIT 2AFF(UR) 16 A / 600 V AC Z109A
For additional information regarding accessories please see:
• Measuring Instruments and Testers catalog
• www.gossenmetrawatt.com
FF(UR) 1.6 A / 700 V AC
Z109E
Accessories
F809 Ever-Ready Case with Cable Compartment – For tabletop operation
– The cover can be snapped to the bottom of the case when using the shoulder strap.
GOSSEN METRAWATT GMBH3
METRA HIT 1A and METRA HIT 2A
Analog Multimeters
Current Measuring AccessoriesSuitable for
All current sensors and transformers are equipped with a connector cable (1.2 to 1.5 m long) with 4 mm safety banana plugs
TypeDesignationMeasuring RangeMeasur-
AC Current Transformer with Current Output
WZ12AClip-on current transformer15 ... 180 A~300 V /
WZ12DClip-on current transformer30 mA ... 150 A~300 V /
Z3511Clip-on current transformer4 ... 500 A~600 V /
Z3512Clip-on current transformer0.5 ... 1000 A~600 V /
Z3514Clip-on current transformer1 ... 2000 A ~600 V /
● Without restriction
ing
CAT III
CAT III
CAT III
CAT III
CAT III
Cat.
Max. to
Wire Dia.
15 mm1 mA/A45 ... 65
15 mm1 mA/A45 ... 65
30 x
63 mm
52 mm1 mA/A30...48 ... 65
64 x
150 mm
Transformation
Ratio
1 mA/A48 ... 65
1 mA/A30...48 ... 65
Frequency
Range
... 400 Hz
... 500 Hz
... 1 kHz
... 5 kHz
... 5 kHz
Intrinsic Error
±(% rdg. + ...)
3%Z219A●●
2.5% +0.1 mAZ219DAs of
3% +0.4 AGTZ 3511
0.5% ... 0.7%GTZ 3512
0.5% +0.1 AGTZ 3514
Article
Number
000 R0001
000 R0001
000 R0001
METRA HIT
1A2A
5 A
As of
50 A
As of
50 A
As of
500 A
As of
5 A
As of
50 A
As of
0 A
As of
500 A
GH185 Protective Rubber CoverWZ12 Clip-On Current TransformerSM16 Current Measuring Adapter
Edited in Germany • Subject to ch ange without notice • PDF version available on the Internet
KS17-2 Cable Set
Cable set with
permanently mounted
test probes and contactprotected angle plugs for
safe measuring. Hook
clips, alligator clips or
push-on lugs can be
attached to the test
probes for special
measuring tasks.