GORMAN‐RUPP OF CANADA LIMITED D ST. THOMAS, ONTARIO, CANADAPrinted in U.S.A.
e2008 The Gorman‐Rupp Company
Register your new
Gorman‐Rupp pump online at
www.grpumps.com
Valid serial number and e‐mail address required.
RECORD YOUR PUMP MODEL AND SERIAL NUMBER
Please record your pump model and serial number in the
spaces provided below. Your Gorman‐Rupp distributor
needs this information when you require parts or service.
Pump Model:
Serial Number:
TABLE OF CONTENTS
INTRODUCTIONPAGE I - 1.................................................
SAFETY ‐ SECTION APAGE A - 1............................................
INSTALLATION - SECTION BPAGE B - 1....................................
PREINSTALLATION INSPECTIONPAGE B - 1............................................
POSITIONING PUMPPAGE B -1.......................................................
LiftingPAGE B - 1.................................................................
MountingPAGE B - 2.............................................................
SUCTION AND DISCHARGE PIPINGPAGE B - 2.........................................
MaterialsPAGE B - 2..............................................................
Line ConfigurationPAGE B - 2......................................................
Connections to PumpPAGE B - 2..................................................
GaugesPAGE B - 2...............................................................
SUCTION LINESPAGE B - 2...........................................................
FittingsPAGE B - 2...............................................................
StrainersPAGE B - 2..............................................................
SealingPAGE B - 2...............................................................
Suction Lines In SumpsPAGE B - 3.................................................
Suction Line PositioningPAGE B - 3................................................
DISCHARGE LINESPAGE B - 4........................................................
SiphoningPAGE B - 4.............................................................
ValvesPAGE B - 4................................................................
LUBRICATIONPAGE B - 4.............................................................
BearingsPAGE B - 4..............................................................
Seal AssemblyPAGE B - 4.........................................................
ALIGNMENTPAGE B - 4..............................................................
Coupled DrivesPAGE B - 5........................................................
V‐Belt DrivesPAGE B - 5...........................................................
ELECTRICAL CONNECTIONSPAGE B - 6...............................................
GROUNDINGPAGE B - 6.............................................................
OPERATION - SECTION CPAGE C - 1......................................
PRIMINGPAGE C - 1.................................................................
Hand PrimersPAGE C - 1..........................................................
Exhaust PrimersPAGE C - 2.......................................................
Auxiliary EjectorsPAGE C - 2.......................................................
Vacuum PumpsPAGE C - 2........................................................
STARTINGPAGE C - 2................................................................
RotationPAGE C - 2..............................................................
OPERATIONPAGE C - 3..............................................................
LeakagePAGE C - 3..............................................................
Liquid Temperature And OverheatingPAGE C - 3.....................................
Strainer CheckPAGE C - 3.........................................................
Pump Vacuum CheckPAGE C - 3..................................................
Operational ChecksPAGE C - 3....................................................
STOPPINGPAGE C - 4................................................................
Cold Weather PreservationPAGE C - 4..............................................
i
TABLE OF CONTENTS
(continued)
BEARING TEMPERATURE CHECKPAGE C - 4..........................................
LUBRICATIONPAGE C - 4.............................................................
Seal AssemblyPAGE C - 4.........................................................
BearingsPAGE C - 5..............................................................
Power SourcePAGE C - 5.........................................................
TROUBLESHOOTING - SECTION DPAGE D - 1..............................
PREVENTIVE MAINTENANCEPAGE D - 3...............................................
PUMP MAINTENANCE AND REPAIR ‐ SECTION EPAGE E - 1.................
STANDARD PERFORMANCE CURVEPAGE E - 1........................................
PARTS LIST:
Pump End AssemblyPAGE E - 3...................................................
PUMP AND SEAL DISASSEMBLY AND REASSEMBLYPAGE E - 4.........................
Pump Casing and Impeller RemovalPAGE E - 4......................................
Wear Ring RemovalPAGE E - 5....................................................
Seal RemovalPAGE E - 5..........................................................
Shaft and Bearing Removal And DisassemblyPAGE E - 5.............................
Shaft and Bearing Reassembly and InstallationPAGE E - 6............................
Wear Ring InstallationPAGE E - 7..................................................
Seal InstallationPAGE E - 7........................................................
Impeller and Pump Casing InstallationPAGE E - 9....................................
Final Pump AssemblyPAGE E - 9..................................................
LUBRICATIONPAGE E - 9.............................................................
Seal AssemblyPAGE E - 9.........................................................
BearingsPAGE E - 9..............................................................
ii
VGH SERIES
OM-06130
INTRODUCTION
Thank You for purchasing a Gorman‐Rupp pump.
Read this manual carefully to learn how to safely
install and operate your pump. Failure to do so
could result in personal injury or damage to the
pump.
This manual will alert personnel to known proce
dures which require special attention, to those
which could damage equipment, and to those
which could be dangerous to personnel. However,
this manual cannot possibly anticipate and provide
detailed precautions for every situation that might
occur during maintenance of the unit. Therefore, it
is the responsibility of the owner/maintenance per
sonnel to ensure that only safe, established main
tenance procedures are used, and that any proce
dures not addressed in this manual are performed
only after establishing that neither personal safety
nor pump integrity are compromised by such prac
tices.
This pump is a VGH Series, centrifugal model with
an enclosed impeller. The pump is designed for
pumping clear liquids that do not contain large en
trained solids. The basic material of construction
for wetted parts is ductile iron, with a gray iron im
peller, cast iron wear rings and steel impeller shaft.
The pump may be approved or modified for handl
ing volatile, flammable liquids only by the Gorman‐
Rupp Company or an authorized distributor.
For information or technical assistance on the pow
er source, contact the power source manufactur
er's local dealer or representative.
The following are used to alert maintenance per
sonnel to procedures which require special atten
tion, to those which could damage equipment, and
to those which could be dangerous to personnel:
Immediate hazards which WILL result in
severe personal injury or death. These
instructions describe the procedure re
quired and the injury which will result
from failure to follow the procedure.
Hazards or unsafe practices which
COULD result in severe personal injury
or death. These instructions describe
the procedure required and the injury
which could result from failure to follow
the procedure.
If there are any questions regarding the pump or
its application which are not covered in this man
ual or in other literature accompanying this unit,
please contact your Gorman‐Rupp distributor, or:
The Gorman‐Rupp Company
P.O. Box 1217
Mansfield, Ohio 44901-1217
Phone: (419) 755-1011
or:
Gorman‐Rupp of Canada Limited
70 Burwell Road
St. Thomas, Ontario N5P 3R7
Phone: (519) 631-2870
Hazards or unsafe practices which COULD
result in minor personal injury or product
or property damage. These instructions
describe the requirements and the possi
ble damage which could result from failure
to follow the procedure.
NOTE
Instructions to aid in installation, operation,and
maintenance, or which clarify a procedure.
PAGE I - 1INTRODUCTION
VGH SERIES
OM-06130
SAFETY ‐ SECTION A
This information applies to VGH Series
basic pumps. Gorman‐Rupp has no
control over or particular knowledge of
the power source which will be used.
Refer to the manual accompanying the
power source before attempting to be
gin operation.
Because pump installations are seldom
identical, this manual cannot possibly
provide detailed instructions and pre
cautions for each specific application.
Therefore, it is the owner/installer's re
sponsibility to ensure that applications
not addressed in this manual are per
formed only after establishing that nei
ther operator safety nor pump integrity
are compromised by the installation.
trained solids. Only the Gorman‐Rupp
Company or an authorized Gorman‐
Rupp distributor may modify a pump or
approve its use for handling volatile,
flammable liquids. If the pump is used
for handling volatile, flammable liquids,
all drivers and/or controls must meet in
dustry standards and codes for use in
an explosive atmosphere. Do not at
tempt to pump liquids for which the
pump, driver and/or controls have not
been approved, or which may damage
the pump or endanger personnel as a
result of pump failure.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Lock out or disconnect the power
source to ensure that the pump will
remain inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
This pump is designed to handle clear
liquids that do not contain large en
If this pump has been approved for use
with volatile and/or flammable liquids,
be certain proper safety practices are
followed before operating or servicing
the pump. Provide adequate ventilation,
prohibit smoking, wear static‐resistant
clothing and shoes. Clean up all fuel
spills immediately after occurrence.
Do not install and operate a non‐explo
sion proof motor in an explosive atmo
sphere. Install, connect, and operate
the motor in accordance with the Na
tional Electric Code and all local codes.
If there is a conflict between the instruc
tions in the manual accompanying the
unit and the National Electric Code or
the applicable local code, the National
or local code shall take precedence.
PAGE A - 1SAFETY
If this pump is used with volatile and/or
flammable liquids, overheating may
produce dangerous fumes. Take pre
cautions to ensure the area surrounding
the pump is adequately ventilated. Al
low the pump to cool and use extreme
caution when venting the pump, or
when removing covers, plates, plugs, or
fittings.
Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam
age to equipment. Suction and dis
charge hoses and piping must be re
moved from the pump before lifting.
VGH SERIESOM-06130
of time. If operated against a closed dis
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.
Overheated pumps can cause severe
burns and injuries. If overheating of the
pump occurs:
1. Stop the pump immediately.
2. Ventilate the area.
3. Allow the pump to completely cool.
4. Check the temperature before
opening any covers, plates,
gauges, or plugs.
5. Vent the pump slowly and cau
tiously.
6. Refer to instructions in this manual
before restarting the pump.
After the pump has been installed, make
certain that the pump and all piping or
hose connections are tight, properly
supported and secure before operation.
Do not operate the pump without the
shields and/or guards in place over the
drive shaft, belts, and/or couplings, or
other rotating parts. Exposed rotating
parts can catch clothing, fingers, or
tools, causing severe injury to person
nel.
Do not operate the pump against a
closed discharge valve for long periods
Do not remove plates, covers, gauges,
pipe plugs, or fittings from an over
heated pump. Vapor pressure within the
pump can cause parts being disen
gaged to be ejected with great force. Al
low the pump to completely cool before
servicing.
Never run this pump backwards. Be cer
tain that rotation is correct before fully
engaging the pump.
Pumps and related equipment must be in
stalled and operated according to all na
tional, local and industry standards.
PAGE A - 2SAFETY
VGH SERIESOM-06130
INSTALLATION - SECTION B
Review all SAFETY information in Section A.
Since pump installations are seldom identical, this
section offers only general recommendations and
practices required to inspect, position, and ar
range the pump and piping.
Most of the information pertains to a standard
static lift application where the pump is positioned
above the free level of liquid to be pumped.
If installed in a flooded suction application where
the liquid is supplied to the pump under pressure,
some of the information such as mounting, line
configuration, and priming must be tailored to the
specific application. Since the pressure supplied
to the pump is critical to performance and safety,
be sure to limit the incoming pressure to 50% of the
maximum permissible operating pressure as
shown on the pump performance curve (see Sec
tion E, Page 1).
For further assistance, contact your Gorman‐Rupp
distributor or the Gorman‐Rupp Company.
PREINSTALLATION INSPECTION
The pump assembly was inspected and tested be
fore shipment from the factory. Before installation,
inspect the pump for damage which may have oc
curred during shipment. Check as follows:
a. Inspect the pump and engine for cracks,
dents, damaged threads, and other obvious
damage.
b. Check for and tighten loose attaching hard
ware. Since gaskets tend to shrink after dry
ing, check for loose hardware at mating sur
faces.
AND REPAIR section of this manual and per
form duties as instructed.
e. If the pump has been stored for more than 12
months, some of the components or lubri
cants may have exceeded their maximum
shelf life. These must be inspected or replaced to ensure maximum pump service.
If the maximum shelf life has been exceeded, or if
anything appears to be abnormal, contact your
Gorman‐Rupp distributor or the factory to deter
mine the repair or updating policy. Do not put the
pump into service until appropriate action has
been taken.
POSITIONING PUMP
Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam
age to equipment. Suction and dis
charge hoses and piping must be re
moved from the pump before lifting.
Lifting
Pump unit weights will vary depending on the
mounting and drive provided. Check the shipping
tag on the unit packaging for the actual weight, and
use lifting equipment with appropriate capacity.
Drain the pump and remove all customer‐installed
equipment such as suction and discharge hoses
or piping before attempting to lift existing, installed
units.
c. Carefully read all tags, decals, and markings
on the pump assembly, and perform all duties
indicated.
d. Check levels and lubricate as necessary. Re
fer to LUBRICATION in the MAINTENANCE
The pump assembly can be seriously
damaged if the cables or chains used to lift
and move the unit are improperly wrapped
around the pump.
PAGE B - 1INSTALLATION
OM-06130VGH SERIES
Mounting
Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount
ing is essential for proper operation.
The pump may have to be supported or shimmed
to provide for level operation or to eliminate vibra
tion.
SUCTION AND DISCHARGE PIPING
Materials
Either pipe or hose maybe used for suction and
discharge lines; however, the materials must be
compatible with the liquid being pumped. If hose is
used in suction lines, it must be the rigid‐wall, rein
forced type to prevent collapse under suction. Us
ing piping couplings in suction lines is not recom
mended.
Line Configuration
Keep suction and discharge lines as straight as
possible to minimize friction losses. Make mini
mum use of elbows and fittings, which substan
tially increase friction loss. If elbows are necessary,
use the long‐radius type to minimize friction loss.
tapped, drill and tap the suction and discharge
lines not less than 18 inches (457,2 mm) from the
suction and discharge ports and install the lines.
Installation closer to the pump may result in erratic
readings.
SUCTION LINES
To avoid air pockets which could affect pump prim
ing, the suction line must be as short and direct as
possible. When operation involves a suction lift, the
line must always slope upward to the pump from
the source of the liquid being pumped; if the line
slopes down to the pump at any point along the
suction run, air pockets will be created.
Fittings
Suction lines should be the same size as the pump
inlet. If reducers are used in suction lines, they
should be the eccentric type, and should be in
stalled with the flat part of the reducers uppermost
to avoid creating air pockets. Valves are not nor
mally used in suction lines, but if a valve is used,
install it with the stem horizontal to avoid air pock
ets.
Strainers
Connections to Pump
Before tightening a connecting flange, align it ex
actly with the pump port. Never pull a pipe line into
place by tightening the flange bolts and/or cou
plings.
Lines near the pump must be independently sup
ported to avoid strain on the pump which could
cause excessive vibration, decreased bearing life,
and increased shaft and seal wear. If hose‐type
lines are used, they should have adequate support
to secure them when filled with liquid and under
pressure.
Gauges
Most pumps are drilled and tapped for installing
discharge pressure and vacuum suction gauges.
If these gauges are desired for pumps that are not
PAGE B - 2INSTALLATION
If a strainer is not furnished with the pump, but is
installed by the pump user, make certain that the
total area of the openings in the strainer is at least
three or four times the cross section of the suction
line, and that the openings will not permit passage
of solids larger than the solids handling capability
of the pump.
This pump is designed to handle up to 1-1/16 inch
(27 mm) diameter spherical solids.
Sealing
Since even a slight leak will affect priming, head,
and capacity, especially when operating with a
high suction lift, all connections in the suction line
should be sealed with pipe dope to ensure an air
tight seal. Follow the sealant manufacturer's rec
ommendations when selecting and applying the
pipe dope. The pipe dope should be compatible
with the liquid being pumped.
VGH SERIESOM-06130
Suction Lines In Sumps
If a single suction line is installed in a sump, it
should be positioned away from the wall of the
sump at a distance equal to 1 1/2 times the diame
ter of the suction line.
If there is a liquid flow from an open pipe into the
sump, the flow should be kept away from the suc
tion inlet because the inflow will carry air down into
the sump, and air entering the suction line will re
duce pump efficiency.
If it is necessary to position inflow close to the suc
tion inlet, install a baffle between the inflow and the
suction inlet at a distance 1‐1/2 times the diameter
of the suction pipe. The baffle will allow entrained
air to escape from the liquid before it is drawn into
the suction inlet.
If two suction lines are installed in a single sump,
the flow paths may interact, reducing the efficiency
of one or both pumps. To avoid this, position the
suction inlets so that they are separated by a dis
tance equal to at least 3 times the diameter of the
suction pipe.
Suction Line Positioning
The depth of submergence of the suction line is
critical to efficient pump operation.
recommended minimum submergence vs. veloc
ity.
Figure 1 shows
NOTE
The pipe submergence required may be reduced
by installing a standard pipe increaser fitting at the
end of the suction line. The larger opening size will
reduce the inlet velocity. Calculate the required
submergence using the following formula based
on the increased opening size (area or diameter).
Figure 1. Recommended Minimum Suction Line Submergence vs. Velocity
PAGE B - 3INSTALLATION