Gorman-Rupp Pumps 84A2-F3L User Manual

ACE
OM−00900−07
August 22, 2005
INSTALLATION, OPERATION,
WITH PARTS LIST
80 SERIES PUMP
MODEL
84A2−F3L
THE GORMAN-RUPP COMPANY D MANSFIELD, OHIO
www.grpumps.com
GORMAN-RUPP OF CANADA LIMITED D ST. THOMAS, ONTARIO, CANADA Printed in U.S.A.
eCopyright by the Gorman-Rupp Company
Register your new Gorman-Rupp pump online at www.grpumps.com/register.
Valid serial number and e-mail address required.
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.
RECORD YOUR PUMP MODEL AND SERIAL NUMBER
Please record your pump model and serial number in the spaces provided below. Your Gorman-Rupp distributor needs this information when you require parts or service.
Pump Model:
Serial Number:
TABLE OF CONTENTS
INTRODUCTION PAGE I − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY - SECTION A PAGE A − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION − SECTION B PAGE B − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Dimensions PAGE B − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PREINSTALLATION INSPECTION PAGE B − 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Battery Specifications And Installation PAGE B − 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
POSITIONING PUMP PAGE B − 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lifting PAGE B − 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting PAGE B − 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SUCTION AND DISCHARGE PIPING PAGE B − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Materials PAGE B − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Line Configuration PAGE B − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connections to Pump PAGE B − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gauges PAGE B − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SUCTION LINES PAGE B − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fittings PAGE B − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sealing PAGE B − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suction Line Positioning PAGE B − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FLOAT SWITCHES PAGE B − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation PAGE B − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DISCHARGE LINES PAGE B − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Siphoning PAGE B − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Valves PAGE B − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bypass Lines PAGE B − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALIGNMENT PAGE B − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATION − SECTION C PAGE C − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRIMING PAGE C − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STARTING PAGE C − 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Starting PAGE C − 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Automatic Starting PAGE C − 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATION PAGE C − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lines With a Bypass PAGE C − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lines Without a Bypass PAGE C − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Leakage PAGE C − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Liquid Temperature And Overheating PAGE C − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Strainer Check PAGE C − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Vacuum Check PAGE C − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPPING PAGE C − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Stopping PAGE C − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Automatic Stopping PAGE C − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety Shutdown System PAGE C − 4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OPERATION IN EXTREME HEAT PAGE C − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BEARING TEMPERATURE CHECK PAGE C − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cold Weather Preservation PAGE C − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
i
TABLE OF CONTENTS
(continued)
TROUBLESHOOTING − SECTION D PAGE D − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PREVENTIVE MAINTENANCE PAGE D − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PUMP MAINTENANCE AND REPAIR - SECTION E PAGE E − 1. . . . . . . . . . . . . . . . . .
STANDARD PERFORMANCE CURVE PAGE E − 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PARTS LISTS:
Pump Model PAGE E − 3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump End Assembly PAGE E − 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Drive Assembly PAGE E − 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PUMP AND SEAL DISASSEMBLY AND REASSEMBLY PAGE E − 7. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suction Check Valve Removal PAGE E − 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Separating Pump and Intermediate from Engine PAGE E − 7. . . . . . . . . . . . . . . . . . . . . . . . . . .
Loosening the Impeller PAGE E − 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Casing and Wear Plate Removal PAGE E − 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Impeller Removal PAGE E − 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Seal Removal and Disassembly PAGE E − 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Separating Intermediate And Drive Assembly From Engine PAGE E − 9. . . . . . . . . . . . . . . . . .
Shaft And Bearing Removal And Disassembly PAGE E − 10. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shaft and Bearing Reassembly And Installation PAGE E − 11. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Securing Intermediate And Drive Assembly To Engine PAGE E − 12. . . . . . . . . . . . . . . . . . . . . .
Seal Reassembly and Installation PAGE E − 12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Impeller Installation PAGE E − 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Casing and Wear Plate Installation PAGE E − 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suction Check Valve Installation PAGE E − 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Final Pump Reassembly PAGE E − 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LUBRICATION PAGE E − 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Seal Assembly PAGE E − 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bearings PAGE E − 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Engine PAGE E − 16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ii
8O SERIES
OM−00900

INTRODUCTION

Thank You for purchasing a Gorman-Rupp pump. Read this manual carefully to learn how to safely
install and operate your pump. Failure to do so could result in personal injury or damage to the pump.
This Installation, Operation, and Maintenance manual is designed to help you achieve the best performance and longest life from your Gorman­Rupp pump.
This pump is an 80 Series, semi-open impeller, self­priming centrifugal model with a suction check valve. The pump is designed for handling most non-volatile, non-flammable liquids containing specified entrained solids. It is powered by a three cylinder air-cooled Deutz diesel engine, model F3L−912D. The basic material of construction for all wetted parts is gray iron and steel.
If there are any questions regarding the pump or its application which are not covered in this manual or in other literature accompanying this unit, please contact your Gorman-Rupp distributor, or write:
neither operator safety nor pump integrity are com­promised by the installation. Pumps and related equipment must be installed and operated ac­cording to all national, local and industry stan­dards.
The following are used to alert maintenance per­sonnel to procedures which require special atten­tion, to those which could damage equipment, and to those which could be dangerous to personnel:
Immediate hazards which WILL result in severe personal injury or death. These instructions describe the procedure re­quired and the injury which will result from failure to follow the procedure.
The Gorman-Rupp Company
P.O. Box 1217
Mansfield, Ohio 44901−1217
Phone: (419) 755−1011
or:
Gorman-Rupp of Canada Limited
70 Burwell Road
St. Thomas, Ontario N5P 3R7
Phone: (519) 631−2870
For information or technical assistance on the en­gine, contact the engine manufacturer’s local dealer or representative.
Because pump installations are seldom identical, this manual cannot possibly provide detailed in­structions and precautions for every aspect of each specific application. Therefore, it is the re­sponsibility of the owner/installer of the pump to ensure that applications not addressed in this manual are performed only after establishing that
Hazards or unsafe practices which COULD result in severe personal injury or death. These instructions describe the procedure required and the injury which could result from failure to follow the procedure.
Hazards or unsafe practices which COULD result in minor personal injury or product or property damage. These instructions describe the requirements and the possi­ble damage which could result from failure to follow the procedure.
NOTE
Instructions to aid in installation, operation,and maintenance, or which clarify a procedure.
PAGE I − 1INTRODUCTION
80 SERIES
OM−00900
SAFETY − SECTION A
This information applies to 80 Series Engine Driven pumps. Refer to the man­ual accompanying the engine before at­tempting to begin operation.
Because pump installations are seldom identical, this manual cannot possibly provide detailed instructions and pre­cautions for each specific application. Therefore, it is the owner/installer’s re­sponsibility to ensure that applications not addressed in this manual are per­formed only after establishing that nei­ther operator safety nor pump integrity are compromised by the installation.
Before attempting to open or service the pump:
al automatic starting system, it is sub­ject to automatic restart. Keep hands and clothing away from the unit to pre­vent injury during automatic operation. Disconnect the positive battery cable before performing any maintenance. Failure to do so may result in serious personal injury.
Before attempting to install, operate, or service this pump, familiarize yourself with this manual, and with all other liter­ature shipped with the pump. Unfamil­iarity with all aspects of pump operation covered in this manual could lead to de­struction of equipment, injury, or death to personnel.
1. Familiarize yourself with this man­ual.
2. Switch off the engine ignition and disconnect the positive battery cable to ensure that the pump will remain inoperative.
3. Allow the pump to completely cool if overheated.
4. Check the temperature before opening any covers, plates, or plugs.
5. Close the suction and discharge valves.
6. Vent the pump slowly and cau­tiously.
7. Drain the pump.
If the pump is equipped with the option-
This pump is designed to handle most non-volatile, non-flammable liquids containing specified entrained solids. Do not attempt to pump volatile, corro-
sive, or flammable materials, or any liq­uids which may damage the pump or en­danger personnel as a result of pump failure.
Use lifting and moving equipment in good repair and with adequate capacity to prevent injuries to personnel or dam­age to equipment. Suction and dis­charge hoses and piping must be re­moved from the pump before lifting.
PAGE A − 1SAFETY
After the pump has been positioned, make certain that the pump and all pip­ing or hose connections are tight, prop­erly supported and secure before oper­ation.
Do not operate the pump against a closed discharge valve for long periods of time. If operated against a closed dis­charge valve, pump components will deteriorate, and the liquid could come to a boil, build pressure, and cause the pump casing to rupture or explode.
Do not remove plates, covers, gauges, pipe plugs, or fittings from an over­heated pump. Vapor pressure within the pump can cause parts being disen­gaged to be ejected with great force. Al­low the pump to completely cool before servicing.
Pumps and related equipment must be in­stalled and operated according to all na­tional, local and industry standards.
80 SERIESOM−00900
Do not operate an internal combustion engine in an explosive atmosphere. When operating an internal combustion engine in an enclosed area, make sure exhaust fumes are piped to the outside. These fumes contain carbon monoxide, a deadly gas that is colorless, tasteless and odorless.
Fuel used by internal combustion en­gines presents an extreme explosion and fire hazard. Make certain that all fuel lines are securely connected and free of leaks. Never refuel a hot or run­ning engine. Avoid overfilling the fuel tank. Always use the correct type of fuel.
Never tamper with the governor to gain more power. The governor establishes safe operating limits that should not be exceeded. The maximum continuous operating speed for this pump is 2300 RPM.
PAGE A − 2 SAFETY
80 SERIES OM−00900
INSTALLATION − SECTION B
Review all SAFETY information in Section A.
Since pump installations are seldom identical, this section offers only general recommendations and practices required to inspect, position, and ar­range the pump and piping.
Most of the information pertains to a standard static lift application where the pump is positioned above the free level of liquid to be pumped.
If installed in a flooded suction application where the liquid is supplied to the pump under pressure, some of the information such as mounting, line configuration, and priming must be tailored to the specific application. Since the pressure supplied
OUTLINE DRAWING
to the pump is critical to performance and safety, be sure to limit the incoming pressure to 50% of the maximum permissible operating pressure as shown on the pump performance curve. (See Sec­tion E, Page 1.) If the pump is fitted with a Gorman­Rupp double grease lubricated seal, the maximum incoming pressure must be reduced to 10 p.s.i.
For further assistance, contact your Gorman-Rupp distributor or the Gorman-Rupp Company.
Pump Dimensions
See Figure 1 for the approximate physical dimen­sions of this pump.
Figure 1. Pump Model 84A2−F3L
PREINSTALLATION INSPECTION
The pump assembly was inspected and tested be­fore shipment from the factory. Before installation, inspect the pump for damage which may have oc­curred during shipment. Check as follows:
a. Inspect the pump and engine for cracks,
dents, damaged threads, and other obvious damage.
b. Check for and tighten loose attaching hard-
ware. Since gaskets tend to shrink after dry-
PAGE B − 1INSTALLATION
OM−00900 80 SERIES
ing, check for loose hardware at mating sur­faces.
c. Carefully read all tags, decals, and markings
on the pump assembly, and perform all duties indicated.
d. Check levels and lubricate as necessary. Re-
fer to LUBRICATION in the MAINTENANCE AND REPAIR section of this manual and per­form duties as instructed.
e. If the pump and
engine have been stored for
more than 12 months, some of the compo­nents or lubricants may have exceeded their maximum shelf life. These must be inspected or replaced to ensure maximum pump serv­ice.
If the maximum shelf life has been exceeded, or if anything appears to be abnormal, contact your Gorman-Rupp distributor or the factory to deter­mine the repair or updating policy. Do not put the pump into service until appropriate action has been taken.
POSITIONING PUMP
Use lifting and moving equipment in good repair and with adequate capacity to prevent injuries to personnel or dam­age to equipment. Suction and dis­charge hoses and piping must be re­moved from the pump before lifting.
Lifting
Pump unit weights will vary depending on the mounting and drive provided. Check the shipping tag on the unit packaging for the actual weight, and use lifting equipment with appropriate capacity. Drain the pump and remove all customer-installed equipment such as suction and discharge hoses or piping before attempting to lift existing, installed units.
Battery Specifications And Installation
Unless otherwise specified on the pump order, the engine battery was not included with the unit. Re­fer to the following specifications when selecting a battery.
Table 1. Battery Specifications
Reserve
Capacity
@ 80_ F
(Minutes)
365
Amp/
Hr.
Rating
175
Approx.
Overall
Dims.
(Inches)
20.5L x
8.75W x
9.75H
Voltage
12 Volts
Cold Crank Amps
@ 0_ F
960−975
Refer to the information accompanying the battery and/or electrolyte solution for activation and charg­ing instructions.
Before installing the battery, clean the positive and negative cable connectors, and the battery termi­nals. Secure the battery by tightening the holddown brackets. The terminals and clamps may be coated with petroleum jelly to retard corro­sion. Connect and tighten the positive cable first, then the negative cable.
The pump assembly can be seriously damaged if the cables or chains used to lift and move the unit are improperly wrapped around the pump.
Mounting
Locate the pump in an accessible place as close as practical to the liquid being pumped. Level mount­ing is essential for proper operation.
The pump may have to be supported or shimmed to provide for level operation or to eliminate vibra­tion.
If the pump has been mounted on a moveable base, make certain the base is stationary by setting the brake and blocking the wheels before attempt­ing to operate the pump.
To ensure sufficient lubrication and fuel supply to the engine, do not position the pump and engine more than 15_ off horizontal for continuous opera­tion. The pump and engine may be positioned up to 30_ off horizontal for intermittent operation
only; however, the engine manufacturer should be
PAGE B − 2 INSTALLATION
80 SERIES OM−00900
consulted for continuous operation at angles greater than 15_.
SUCTION AND DISCHARGE PIPING
Materials
Either pipe or hose maybe used for suction and discharge lines; however, the materials must be compatible with the liquid being pumped. If hose is used in suction lines, it must be the rigid-wall, rein­forced type to prevent collapse under suction. Us­ing piping couplings in suction lines is not recom­mended.
Line Configuration
Keep suction and discharge lines as straight as possible to minimize friction losses. Make mini­mum use of elbows and fittings, which substan­tially increase friction loss. If elbows are necessary, use the long-radius type to minimize friction loss.
Connections to Pump
Before tightening a connecting flange, align it ex­actly with the pump port. Never pull a pipe line into place by tightening the flange bolts and/or cou­plings.
Lines near the pump must be independently sup­ported to avoid strain on the pump which could cause excessive vibration, decreased bearing life, and increased shaft and seal wear. If hose-type lines are used, they should have adequate support to secure them when filled with liquid and under pressure.
Gauges
Most pumps are drilled and tapped for installing discharge pressure and vacuum suction gauges. If these gauges are desired for pumps that are not tapped, drill and tap the suction and discharge lines not less than 18 inches (457,20 mm) from the suction and discharge ports and install the lines. Installation closer to the pump may result in erratic readings.
possible. When operation involves a suction lift, the line must always slope upward to the pump from the source of the liquid being pumped; if the line slopes down to the pump at any point along the suction run, air pockets will be created.
Fittings
Suction lines should be the same size as the pump inlet. If reducers are used in suction lines, they should be the eccentric type, and should be in­stalled with the flat part of the reducers uppermost to avoid creating air pockets. Valves are not nor­mally used in suction lines, but if a valve is used, install it with the stem horizontal to avoid air pock­ets.
Strainers
If a strainer is furnished with the pump, be certain to use it; any spherical solids which pass through a strainer furnished with the pump will also pass through the pump itself.
If a strainer is not furnished with the pump, but is installed by the pump user, make certain that the total area of the openings in the strainer is at least three or four times the cross section of the suction line, and that the openings will not permit passage of solids larger than the solids handling capability of the pump.
This pump is designed to handle up to 1-1/8 inch (28,6 mm) diameter spherical solids.
Sealing
Since even a slight leak will affect priming, head, and capacity, especially when operating with a high suction lift, all connections in the suction line should be sealed with pipe dope to ensure an air­tight seal. Follow the sealant manufacturer’s rec­ommendations when selecting and applying the pipe dope. The pipe dope should be compatible with the liquid being pumped.
Suction Line Positioning
SUCTION LINES
To avoid air pockets which could affect pump prim­ing, the suction line must be as short and direct as
The depth of submergence of the suction line is critical to efficient pump operation. Figure 2 shows recommended minimum submergence vs. veloc-
ity.
PAGE B − 3INSTALLATION
OM−00900 80 SERIES
NOTE
The pipe submergence required may be reduced by installing a standard pipe increaser fitting at the end of the suction line. The larger opening size will
reduce the inlet velocity. Calculate the required submergence using the following formula based on the increased opening size (area or diameter).
Figure 2. Recommended Minimum Suction Line Submergence vs. Velocity
FLOAT SWITCHES
Installation
The standard pump is not furnished with a means to automatically regulate liquid level. However, if the unit is equipped with the optional auto-start control system, the pump can be conformed to start and stop as the liquid level in the wet well or sump rises and falls. The autostart option employs either a single or double float switch system, where a bulb raises or lowers (floats) with the liquid level, thus activating an enclosed miniature switch. The floats are equipped with a socket type connector that plugs into a matching receptacle on the auto­start control box.
Standard floats are equipped with 50 feet (15,2 m) of cable.
When installing the floats, note the following:
a. Be sure to provide sufficient room in the wet
well or sump so that floats do not get ob­structed or drawn into the suction line. If a flex­ible suction hose is used, it may be extended to lay along the bottom of the wet well or sump and the float can be attached to the hose above the point where it bends along the bot­tom. Direct the suction line toward the flow, and the float(s) away from the flow. If a stand­pipe is available, attach the float switch cable to the standpipe in the sump at the approxi­mate desired liquid level.
b. In a single float system, the cable can be teth-
ered to the suction line or standpipe approxi­mately 6 inches (152 mm) above the float. This setting allows approximately 9 inches (229 mm) of liquid rise between pump start/ stop. The start/stop interval may be increased by extending the float end of the cable. The liquid level in the sump will increase approxi­mately 8 inches (203 mm) between start/stop
PAGE B − 4 INSTALLATION
80 SERIES OM−00900
intervals for every 6 inches (152 mm) of cable increase.
c. If a double float switch system is used, posi-
tion the Start" float at the desired high water
ENGINE
CONTROL
BOX
ON
(Emptying)
OFF
(Filling)
OPERATING
CABLE
TETHER
RANGE
(See Table Below)
POINT
OFF
(Emptying)
1.25" Pipe (Not Furnished)
ON
(Filling)
level in the sump, and the Stop" float at the desired low water level in the pump.
d. Refer to Figure 3 for additional float switch
data.
3.0
(0.9)
2.5
(.76)
2.0
(0.6)
1.5
(.46)
1.0
(0.3)
0.5
(.15)
1.0
(0.3)
APPROXIMATE FREE CORD LENGTH IN FT. (M)
2.0
(0.6)
3.0
(0.9)
4.0
(1.2)
Figure 3. Float Switch Data
DISCHARGE LINES
Siphoning
Do not terminate the discharge line at a level lower than that of the liquid being pumped unless a si­phon breaker is used in the line. Otherwise, a si­phoning action causing damage to the pump could result.
Valves
If a throttling valve is desired in the discharge line, use a valve as large as the largest pipe to minimize friction losses. Never install a throttling valve in a suction line.
With high discharge heads, it is recommended that a throttling valve and a system check valve be in­stalled in the discharge line to protect the pump from excessive shock pressure and reverse rota­tion when it is stopped.
If the application involves a high discharge head, gradually close the discharge throttling valve before stopping the pump.
Bypass Lines
If a system check valve is used due to high dis­charge head, it may be necessary to vent trapped air from the top of the pump during the priming process. This may be accomplished by installing a bypass line from the top of the pump, back to the source of liquid. The end of the bypass line must be submerged. The line must be large enough to pre­vent clogging, but not so large as to affect pump discharge capacity.
ALIGNMENT
The alignment of the pump and engine is critical for trouble-free mechanical operation. The driver and pump must be mounted so that their shafts are aligned with and parallel to each other. Refer to Se-
curing Intermediate And Drive Assembly To En­gine in MAINTENANCE AND REPAIR, Section E
for details.
PAGE B − 5INSTALLATION