Gorman-Rupp Pumps 02C3-B User Manual

BC
OM‐01087‐02
April 8, 1981
Rev. B 05‐30‐13
AND MAINTENANCE MANUAL
WITH PARTS LIST
0 SERIES PUMP
MODEL
02C3-B
THE GORMAN‐RUPP COMPANY D MANSFIELD, OHIO
www.grpumps.com
GORMAN‐RUPP OF CANADA LIMITED D ST. THOMAS, ONTARIO, CANADA Printed in U.S.A.
e2009 The Gorman‐Rupp Company
Register your new
Gorman‐Rupp pump online at
www.grpumps.com
Valid serial number and e‐mail address required.
RECORD YOUR PUMP MODEL AND SERIAL NUMBER
Please record your pump model and serial number in the spaces provided below. Your Gorman‐Rupp distributor needs this information when you require parts or service.
Pump Model:
Serial Number:
TABLE OF CONTENTS
INTRODUCTION PAGE I - 1.................................................
SAFETY ‐ SECTION A PAGE A - 1............................................
INSTALLATION - SECTION B PAGE B - 1....................................
Pump Dimensions PAGE B - 1.....................................................
PREINSTALLATION INSPECTION PAGE B - 1............................................
POSITIONING PUMP PAGE B - 2.......................................................
Lifting PAGE B - 2.................................................................
Mounting PAGE B - 2.............................................................
SUCTION AND DISCHARGE PIPING PAGE B - 2.........................................
Materials PAGE B - 2..............................................................
Line Configuration PAGE B - 2......................................................
Connections to Pump PAGE B - 2..................................................
Gauges PAGE B - 2...............................................................
SUCTION LINES PAGE B - 3...........................................................
Fittings PAGE B - 3...............................................................
Strainers PAGE B - 3..............................................................
Sealing PAGE B - 3...............................................................
Suction Line Positioning PAGE B - 3................................................
DISCHARGE LINES PAGE B - 4........................................................
Siphoning PAGE B - 4.............................................................
Valves PAGE B - 4................................................................
ALIGNMENT PAGE B - 4..............................................................
Coupled Drives PAGE B - 5........................................................
V‐Belt Drives PAGE B - 5...........................................................
DRIVE BELT TENSIONING PAGE B - 6..................................................
General Rules of Tensioning PAGE B - 6.............................................
GROUNDING PAGE B - 6.............................................................
OPERATION - SECTION C PAGE C - 1......................................
PRIMING PAGE C - 1.................................................................
STARTING PAGE C - 1................................................................
Rotation PAGE C - 1..............................................................
OPERATION PAGE C - 2..............................................................
Lines With a Bypass PAGE C - 2....................................................
Lines Without a Bypass PAGE C - 2.................................................
Leakage PAGE C - 2..............................................................
Liquid Temperature And Overheating PAGE C - 2.....................................
Strainer Check PAGE C - 2.........................................................
Pump Vacuum Check PAGE C - 2..................................................
STOPPING PAGE C - 3................................................................
BEARING TEMPERATURE CHECK PAGE C - 3..........................................
Cold Weather Preservation PAGE C - 3..............................................
TROUBLESHOOTING - SECTION D PAGE D - 1..............................
PREVENTIVE MAINTENANCE PAGE D - 3...............................................
i
TABLE OF CONTENTS
(continued)
PUMP MAINTENANCE AND REPAIR ‐ SECTION E PAGE E - 1.................
STANDARD PERFORMANCE CURVE PAGE E - 1........................................
PARTS LIST:
Pump Model PAGE E - 3..........................................................
PUMP AND SEAL DISASSEMBLY AND REASSEMBLY PAGE E - 4.........................
Pump Disassembly PAGE E - 4.....................................................
Impeller Removal PAGE E - 4......................................................
Seal Removal and Disassembly PAGE E - 5..........................................
Shaft and Bearing Removal and Disassembly PAGE E - 5.............................
Shaft and Bearing Reassembly and Installation PAGE E - 6............................
Seal Reassembly and Installation PAGE E - 7........................................
Impeller Installation PAGE E - 8.....................................................
Pump Reassembly PAGE E - 9.....................................................
Final Pump Assembly PAGE E - 9..................................................
LUBRICATION PAGE E - 9.............................................................
Seal Assembly PAGE E - 9.........................................................
Bearings PAGE E - 9..............................................................
Power Source PAGE E - 9.........................................................
ii
0 SERIES
OM-01087

INTRODUCTION

Thank You for purchasing a Gorman‐Rupp pump. Read this manual carefully to learn how to safely
install and operate your pump. Failure to do so could result in personal injury or damage to the pump.
This pump is an 0 Series, closed impeller, self‐prim ing centrifugal model, with straight‐in suction, with out a suction check valve. It is designed to handle petroleum products or other clean liquids that do not contain large entrained solids. The basic mate rial of construction for wetted parts is gray iron, with cast iron impeller and steel shaft.
If there are any questions regarding the pump or its application which are not covered in this man ual or in other literature accompanying this unit, please contact your Gorman‐Rupp distributor, or write:
The Gorman‐Rupp Company
P.O. Box 1217
Mansfield, Ohio 44901-1217
Phone: (419) 755-1011
or:
Gorman‐Rupp of Canada Limited
70 Burwell Road
St. Thomas, Ontario N5P 3R7
Phone: (519) 631-2870
The following are used to alert maintenance per sonnel to procedures which require special atten tion, to those which could damage equipment, and to those which could be dangerous to personnel:
Immediate hazards which WILL result in severe personal injury or death. These instructions describe the procedure re quired and the injury which will result from failure to follow the procedure.
Hazards or unsafe practices which COULD result in severe personal injury or death. These instructions describe the procedure required and the injury which could result from failure to follow the procedure.
For information or technical assistance on the pow er source, contact the power source manufactur er's local dealer or representative.
Because pump installations are seldom identical, this manual cannot possibly provide detailed in structions and precautions for every aspect of each specific application. Therefore, it is the re sponsibility of the owner/installer of the pump to ensure that applications not addressed in this manual are performed only after establishing that neither operator safety nor pump integrity are com promised by the installation. Pumps and related equipment must be installed and operated ac cording to all national, local and industry stan dards.
Hazards or unsafe practices which COULD result in minor personal injury or product or property damage. These instructions describe the requirements and the possi ble damage which could result from failure to follow the procedure.
NOTE
Instructions to aid in installation, operation,and maintenance, or which clarify a procedure.
PAGE I - 1INTRODUCTION
0 SERIES

SAFETY ‐ SECTION A

This information applies to 0 Series ba sic pumps. Gorman‐Rupp has no con trol over or particular knowledge of the power source which will be used. Refer to the manual accompanying the power source before attempting to begin oper ation.
This manual will alert personnel to known procedures which require spe cial attention, to those which could damage equipment, and to those which could be dangerous to personnel. How ever, this manual cannot possibly antici pate and provide detailed instructions and precautions for every situation that might occur during maintenance of the unit. Therefore, it is the responsibility of the owner/maintenance personnel to ensure that only safe, established main tenance procedures are used, and that any procedures not addressed in this manual are performed only after estab lishing that neither personal safety nor pump integrity are compromised by such practices.
OM-01087
This pump is designed to handle petro leum products or other clean liquids that do not contain large entrained sol ids. Do not attempt to pump liquids which may damage the pump or endan ger personnel as a result of pump fail ure.
This pump is designed to handle petro leum products or other clean liquids that do not contain large entrained sol ids. If the pump is used for handling vol atile, flammable liquids, all drivers and/ or controls must meet industry stan dards and codes for use in an explosive atmosphere. Do not attempt to pump liq uids for which the pump, driver and/or controls have not been approved, or which may damage the pump or endan ger personnel as a result of pump fail ure.
Before attempting to open or service the pump:
1. Familiarize yourself with this man ual.
2. Disconnect or lock out the power source to ensure that the pump will remain inoperative.
3. Allow the pump to completely cool if overheated.
4. Check the temperature before opening any covers, plates, or plugs.
5. Close the suction and discharge valves.
6. Vent the pump slowly and cau tiously.
7. Drain the pump.
If this pump is used for volatile and/or flammable liquids, be certain proper safety practices are followed before op erating or servicing the pump. Provide adequate ventilation, prohibit smoking, wear static‐resistant clothing and shoes. Clean up all fuel spills immedi ately after occurrence.
Do not install and operate a non‐explo sion proof motor in an explosive atmo sphere. Install, connect, and operate the motor in accordance with the Na
PAGE A - 1SAFETY
tional Electric Code and all local codes. If there is a conflict between the instruc tions in the manual accompanying the unit and the National Electric Code or the applicable local code, the National or local code shall take precedence.
If this pump is used with volatile and/or flammable liquids, overheating may produce dangerous fumes. Take pre cautions to ensure the area surrounding the pump is adequately ventilated. Al low the pump to cool and use extreme caution when venting the pump, or when removing covers, plates, plugs, or fittings.
Use lifting and moving equipment in good repair and with adequate capacity to prevent injuries to personnel or dam age to equipment. Suction and dis charge hoses and piping must be re moved from the pump before lifting.
0 SERIESOM-01087
Do not operate the pump against a closed discharge valve for long periods of time. If operated against a closed dis charge valve, pump components will deteriorate, and the liquid could come to a boil, build pressure, and cause the pump casing to rupture or explode.
Overheated pumps can cause severe burns and injuries. If overheating of the pump occurs:
1. Stop the pump immediately.
2. Ventilate the area.
3. Allow the pump to completely cool.
4. Check the temperature before opening any covers, plates, gauges, or plugs.
5. Vent the pump slowly and cau tiously.
6. Refer to instructions in this manual before restarting the pump.
Do not remove plates, covers, gauges, pipe plugs, or fittings from an over heated pump. Vapor pressure within the pump can cause parts being disen
After the pump has been installed, make certain that the pump and all piping or
gaged to be ejected with great force. Al low the pump to cool before servicing.
hose connections are tight, properly supported and secure before operation.
Never run this pump backwards. Be cer tain that rotation is correct before fully engaging the pump.
Do not operate the pump without the shields and/or guards in place over the drive shaft, belts, and/or couplings, or other rotating parts. Exposed rotating parts can catch clothing, fingers, or tools, causing severe injury to person nel.
PAGE A - 2 SAFETY
Pumps and related equipment must be in stalled and operated according to all na tional, local and industry standards.
0 SERIES OM-01087

INSTALLATION - SECTION B

Review all SAFETY information in Section A.
Since pump installations are seldom identical, this section offers only general recommendations and practices required to inspect, position, and ar range the pump and piping.
Most of the information pertains to a standard static lift application where the pump is positioned above the free level of liquid to be pumped.
If installed in a flooded suction application where the liquid is supplied to the pump under pressure, some of the information such as mounting, line
OUTLINE DRAWING
configuration, and priming must be tailored to the specific application. Since the pressure supplied to the pump is critical to performance and safety, be sure to limit the incoming pressure to 50% of the maximum permissible operating pressure as shown on the pump performance curve.
For further assistance, contact your Gorman‐Rupp distributor or the Gorman‐Rupp Company.
Pump Dimensions
See Figure 1 for the approximate physical dimen sions of this pump.
Figure 1. Pump Model 02C3-B
PREINSTALLATION INSPECTION
The pump assembly was inspected and tested be fore shipment from the factory. Before installation, inspect the pump for damage which may have oc curred during shipment. Check as follows:
a. Inspect the pump and engine for cracks,
dents, damaged threads, and other obvious damage.
b. Check for and tighten loose attaching hard
ware. Since gaskets tend to shrink after dry ing, check for loose hardware at mating sur faces.
c. Carefully read all tags, decals, and markings
on the pump assembly, and perform all duties indicated.
d. Check levels and lubricate as necessary. Re
fer to LUBRICATION in the MAINTENANCE
PAGE B - 1INSTALLATION
OM-01087 0 SERIES
AND REPAIR section of this manual and per
form duties as instructed.
e. If the pump and engine have been stored for
more than 12 months, some of the compo nents or lubricants may have exceeded their maximum shelf life. These must be inspected or replaced to ensure maximum pump serv ice.
If the maximum shelf life has been exceeded, or if anything appears to be abnormal, contact your Gorman‐Rupp distributor or the factory to deter mine the repair or updating policy. Do not put the pump into service until appropriate action has been taken.
POSITIONING PUMP
Use lifting and moving equipment in good repair and with adequate capacity to prevent injuries to personnel or dam age to equipment. Suction and dis charge hoses and piping must be re moved from the pump before lifting.
Lifting
The pump may have to be supported or shimmed to provide for level operation or to eliminate vibra tion.
SUCTION AND DISCHARGE PIPING
Pump performance is adversely effected by in creased suction lift, discharge elevation, and fric tion losses. Contact the factory to be sure your overall application allows pump to operate within the safe operation range.
Materials
Either pipe or hose maybe used for suction and discharge lines; however, the materials must be compatible with the liquid being pumped. If hose is used in suction lines, it must be the rigid‐wall, rein forced type to prevent collapse under suction. Us ing piping couplings in suction lines is not recom mended.
Line Configuration
Keep suction and discharge lines as straight as possible to minimize friction losses. Make mini mum use of elbows and fittings, which substan tially increase friction loss. If elbows are necessary, use the long‐radius type to minimize friction loss.
Connections to Pump
Pump unit weights will vary depending on the mounting and drive provided. Check the shipping tag on the unit packaging for the actual weight, and use lifting equipment with appropriate capacity. Drain the pump and remove all customer‐installed equipment such as suction and discharge hoses or piping before attempting to lift existing, installed units.
The pump assembly can be seriously damaged if the cables or chains used to lift and move the unit are improperly wrapped around the pump.
Mounting
Locate the pump in an accessible place as close as practical to the liquid being pumped. Level mount ing is essential for proper operation.
Before tightening a connecting flange, align it ex actly with the pump port. Never pull a pipe line into place by tightening the flange bolts and/or cou plings.
Lines near the pump must be independently sup ported to avoid strain on the pump which could cause excessive vibration, decreased bearing life, and increased shaft and seal wear. If hose‐type lines are used, they should have adequate support to secure them when filled with liquid and under pressure.
Gauges
Most pumps are drilled and tapped for installing discharge pressure and vacuum suction gauges. If these gauges are desired for pumps that are not tapped, drill and tap the suction and discharge lines not less than 18 inches (457 mm) from the suction and discharge ports and install the lines. Installation closer to the pump may result in erratic readings.
PAGE B - 2 INSTALLATION