HRVATSKI REGISTAR BRODOVA Croatian Register of Shipping
POTVRDA O TIPNOM ODOBRENJU
TYPE APPROVAL CERTIFICATE
Br/ No 03-001161 / 030808
Potvrđuje se da je ovaj proizvod, u skladu s Pravilima za klasifikaciju pomorskih brodova, Dio 1. - Opći propisi, Odjeljak 3. - Tipno odobrenje
proizvoda, odobren za ugradnju na brodove i postrojenja pod nadzorom Hrvatskog registra brodova.
This is to certify that this product on the basis of the Rules for the classification of sea-going ships, Part 1 - General requirements, Chapter 3 - Type approval of products, is
approved for use on board ships and installations under supervision of the Croatian Register of Shipping.
TIP I OPIS PROIZVODA:
TYPE AND DESCRIPTION OF PRODUCT:
Electronic Engine Control and Monitoring System for Caterpillar Engines
C7 ACERT, C9, C9 ACERT, C32 ACERT, MaK M32 CR
ADEM IV (A4E4)
CATERPILLAR Inc.
PROIZVOĐAČ:
ANUFACTURER:
PROIZVOD UDOVOLJAVA SLIJEDEĆIM PRAVILIMA/PROPISIMA:
THE PRODUCT MEETS FOLLOWING RULES/REGULATIONS:
Hrvatski registar brodova : Pravila za tehnički nadzor pomorskih brodova, Dio 13 i Dio 9
Croatian Register of Shipping: Rules for the Technical Supervision of Sea-Going Ships, Part 13
PODRUČJE PRIMJENE/POSEBNI GRANIČNI UVJETI:
IELD OF APPLICATION/SPECIAL OPERATIONAL LIMIT
Correct configuration and set up for each delivery to be tested during commissioning, after
installation, under the supervision of a Society Surveyor.
pproval also valid for ships to be granted with class notations: AUT 1, AUT 2 and AUT 3.
3701 State Road 26 East
LAFAYETTE, Indiana 47905-4856
UNITED STATES OF AMERICA
and Part 9
:
ODOBRENJE VRIJEDI DO:
PPROVAL IS VALID UNTIL:
Mjesto i datum
lace and date
Split, 2009-03-18
2013-03-18
M.P.
(Seal)
UZ UVJETE NAVEDENE NA POLEĐINI
SUBJECT TO CONDITION OVERLEAF
Goran Begović, dipl.ing.
QF-PTO-01 1 / 2 2009-01
Odobrenje je valjano ako je ovaj proizvod izveden prema slijedećoj dokumentaciji:
The approval is valid if this product is manufactured in accordance with the following documentation:
PRODUCT DESCRIPTION:
C7 & C9
ADEM IV Control and Monitoring System
System level schematics (with sensors and I/O) 256-7835 243-0451 TBD
Control Gp. - ADEM IV 274-1955 274-1955
Air Cooled ECM Assembly Drawing 28018069
Air Cooled Housing 23003128
Schematic 28018074
Schematic - Power Supply 28018081
Board Assembly ph3main_sig1.pdf -and-
Board Assembly - Power Supply ph3pwbdbottom.pdf -and-
Associated Sensors/Components (Governing function only)
Primary Speed Timing
Secondary Speed Timing
Engine Oil Pressure
Boost Pressure/ Inlet Air Pressure
Exhaust Temperature Sensor
Other Temperature sensors: Coolant Temperature, Fuel
Temperature, Intake Air Temperature
Injectors
ECM Software Version
ECM Suffix Code
Fuel Pressure sensors
ACERT
(Prop.)
109-7194 201-6616 338-0839
109-7195 201-6615
267-9710 253-0597 241-9595
A4E4v2
(Version 2),
June 2005
JV JV JV
C32 ACERT
(Prop.)
ph3maintop.pdf
ph3pwrbdtop.pdf
194-6725 161-1705
218-3840 161-1704
163-7882
130-9811
A4E4v2
(Version 2),
June 2005
C9 (Aux.)
245-4630
A4E4v2
(Version 2),
June 2005
MaK M32 CR
(Prop/Aux)
338-0840
338-0842
338-0843
TYPE APPROVAL DOCUMENTATION:
- ADEM IV – A4:E4v2 Electronic Control Module - Product Information Sheet
- EC-29 Marine Society Test Plan for ADEM IV, Ver. 1.1, September 27,2005.
- EC-29 Marine Society Testing Procedure For A4E4v2 System, Ver. 1.1, September 30, 2005.
- EMC Test Report of the A4E4v2 Marine Engine Controller (1083), October 04, 2005.
- IP Enclosure Test Reports 33260-1/33260-2, September 27-28,2005.
- Functional Test Report, C32 ACERT, September 28,2005.
- Witness Test Summary Report, Ver1.0, October 24,2005.
CLAUSE FOR APPLICATION SOFTWARE CONTROL:
All changes in software are to be recorded as long as the system is in use on board. The records
of all changes are to be forwarded to CRS for evaluation and approval. Major changes in the
software are to be approved before being installed in the computer.
NOTES:
♦ The ADEM IV control for propulsion engine, with single engine application, is acceptable in
combination with an additional back-up ECM as an approved means for independent operation and
safety protection.
♦ Gensets and propulsion engines, in dual or multi engine applications, can be operated with a single
ADEM IV control module.
♦ An auxiliary engine used for emergency genset power, must use ADEM IV with back-up ECM as an
approved means for independent operation and over-speed protection only.
♦ Any relaxation from a.m. applications may be accepted after consideration by the Class Society.
Ovo odobrenje ne isključuje zahtjev za nadzorom tijekom izradbe proizvoda kod proizvođača, u skladu s gore navedenim Pravilima.
This approval does not eliminate the need for inspection during manufacturing of the product into manufacturers shop in compliance with a.m. Rules.
Raščlana Zamjenjuje potvrdu
13.01.00 03-000970/030600
QF-PTO-01 2 / 2 2009-01