PURE SINE WAVE INVERTER REMOTE
GP-ISW-R-12/24
User Manual
GP-ISW-R
© 2018 Go Power!® a wholly-owned subsidiary of Valterra Products, LLC.
Worldwide Technical Support and Product Information gpelectric.com
Go Power! Corporate Headquarters
201-710 Redbrick St. Victoria, BC Canada V8T 5J3
Tel: 1.866.247.6527
80325_MANUAL_ISW-R_RevB
gpelectric.com
GP-ISW-R
15
14
13
12
11
10
®

page 2 | gpelectric.com
1. CONTENTS
2. FEATURES .......................................................................................................................... 2
3. SPECIFICATION ................................................................................................................. 2
4. INTRODUCTION .................................................................................................................3
4.1 FRONT PANEL INTRODUCTION .................................................................... 3
4.2 REAR PANEL INTRODUCTION ...................................................................... 5
1.0 TABLE OF CONTENTS
2.0 FEATURES
The GP-ISW-R remote allows the switching on and off of any GP-ISW inverter from a
remote location. The LED display indicates the following:
• Battery bank voltage display
• Output power display
• Error condition indicator (High Battery, Low Battery, Over Temperature, Over
Load conditions)
• Action condition indicator (INV, POWER SAVING, GRID)
3.0 SPECIFICATIONS
Specication Item GP-ISW-R-12/24
Input Voltage 10.5 ~ 66VDC
Operating Temperature Range 0 ~ 40°C
Storage Temperature Range -30°C ~ 70°C
Standby Current Draw < 80mA
Compatible Inverters GP-ISW700/1000/1500/2000/3000/4000

gpelectric.com | page 3
4.1 FRONT PANEL INTRODUCTION
gpelectric.com
GP-ISW-R-12
15
14
13
12
11
10
®
1
3 2
4
11 POWER ON/OFF BUTTON
Power ON/OFF button turns the inverter on or off.
2 OUTPUT POWER INDICATOR
Output power indicator shows the power draw from the inverter by the load. Ideally,
the output power indicator should remain in the green & orange area of the bar
chart.
If the output power indicator is up to the red area, the OLP LED will ash and the
inverter will shut down.
Power ON/OFF button Battery voltage indicator
Output power indicator Other indicators
11 3
2 4
Note: the 24 volt inverter remote’s Battery voltage
indicator reads “20, 22, 24, 26, 28, 30.”
4. INTRODUCTION

page 4 | gpelectric.com
4. INTRODUCTION
3
4
BATTERY VOLTAGE INDICATOR
Battery voltage indicator will move up and down as the battery voltage changes.
Ideally, the voltage should remain in the green area of the bar chart.
If the voltage goes into the red area at the top and bottom of the bar chart, the
inverter may shut down.
OTHER INDICATORS
• OVP (Over voltage protection):
Indicates that the inverter will shut down because its input voltage is above the
voltage limit.
• UVP (Under voltage protection):
Indicates that inverter will shut down because its input voltage is below the
voltage minimum.
• OLP (Overload protection indicator):
Indicates the inverter will shut down due to a short circuit or overload
protection.
• OTP (Over temperature protection indicator):
Indicates the inverter will shut down due to over temperature protection. Once
the inverter cools down, the indicator will turn off automatically.
• INV indicator:
Indicates the inverter is ready.
• PWR. SAV. indicator:
Power saving functions are described below:
LED Meaning Inverter Output
Solid Ready ON
Flashing Active OFF
Off Inactive
• GRID indicator:
Indicates the AC Grid is connected to the inverter (only functional when
connecting inverter series with Transfer Relay).

gpelectric.com | page 5
4. INTRODUCTION
4.2 REAR PANEL INTRODUCTION
89
76
Ø4.5
77
10.5
6.5 72
AUX
22±1.0
10±0.5
Ø4.5±0.3
5
6
7
5 AUX PORT
Note: the AUX port is only used in work trucks.
The connector (shown above) attached to AUX wire (AWG 14 or 16) must be connected with a 12V / 0.5A fuse.
• Ignition Lockout function:
Turns OFF the inverter when the auxiliary input wiring is connected to the ACC
with 12 volts.
• Return Override function:
Turns ON the inverter when the auxiliary input wiring is connected to the
reversed gear shift with 12 volts.
Connector
AUX port JP1
Phone jack connector
5 7
6

page 6 | gpelectric.com
4. INTRODUCTION
6 PHONE JACK CONNECTOR
1. Before connecting, make sure to switch the inverter to REMOTE mode.
2. Connect the RJ-11 cable between the ISW-R remote and the inverter.
WARNING!
DO NOT use a standard telephone cable.
A
6
1
B
6
1
12.4±0.3
6.5±0.2
14.6±0.3
3.1±0.2
12.4±0.3
6.5±0.2
14.6±0.3
3.1±0.2
A
6
5
4
3
2
1
WIRE COLOR
YELLOW
BLUE
GREEN
WHITE
BLACK
RED
B
6
5
4
3
2
1

gpelectric.com | page 7
7 JP1
The JP1 is to set either the Return Override function or the Ignition Lockout
function.
• JP1 jumper “Short” - Return Override function:
Turns ON the inverter when the auxiliary input wiring is connected to the
reversed gear shift with 12 volts.
• JP1 jumper “Open” - Ignition Lockout function:
Turns OFF the inverter when the auxiliary input wiring is connected to the ACC
with 12 volts.
• The connector which is connected to AUX power must be used with a 12V /
0.5A fuse.
Triggered signal
JP1 Inverter Status
AUX
1 Open OFF
0 Open ON
1 Short ON
0 Short OFF
Note: default mode is Open.