Go Power! GP-600 User Manual

Page 1
Go PGo P
Go P
Go PGo P
GP-600 Inverter
oo
o
oo
ww
er! Maner! Man
w
er! Man
ww
er! Maner! Man
ual
Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 T el: 866-247-6527 Fax: 866-607-6527
Email: info@gpelectric.com
Page 2
Go Power! Modified Sine Wave Inverter
Table of Contents
1. INTRODUCTION 3
2. SPECIFICATIONS 3
3. FEATURES 4
4. INSTALLATION 5
5. OPERATION 8
6. OPERA TING LIMITS 8
7. TROUBLESHOOTING 9
8. MAINTENANCE 10
9. WARRANTY 10
Owner’s Manual
Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Toll Free Tel: 866-247-6527 Toll Free Fax: 866-607-6527
Email: info@gpelectric.com
Rev2.0 GPModifiedSWInstallGuide.doc
2
11
Page 3
Go Power! Modified Sine Wave Inverter
Owner’s Manual
Go Power! Modified Sine Wave Inverter
Owner’s Manual
Low battery alarm on all the time, LED indicator is red.
Low input voltage.
Poor DC wiring, poor battery condition.
Have qualified service techni­cian check and replace.
Make sure that inverter is connected to 12 V battery. Check regulation of charging system.
Recharge battery. Use proper cable and make solid connec­tions. Use new battery.
8. Maintenance
Very little maintenance is required to keep your inverter operating properly. You should clean the exterior of the unit periodically with a dry cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals.
9. Warranty
We warrant this product against defects in materials and workmanship for a period of 12 months from the date of purchase and will repair or replace any defective Go Power! Inverter when directly returned, postage prepaid, to the manufacturer. This warranty will be considered void if the unit has suffered any obvious physical damage or alteration either internally or externally, and does not cover damage arising from improper use such as plugging the unit into an unsuitable power sources, attempting to operate products with excessive power consumption requirements, reverse polarity, or use in unsuitable climates.
This is the only warranty and the company makes no other warranties, express or implied, including warranties of merchantability and fitness for a particular purpose. Repair or replacement are your sole remedies and shall not be liable for damages, whether direct, incidental, special or consequential, even though caused by negli­gence or other fault.
1. Introduction
The Go Power! Inverter series provides mobile power for people on the go. Run standard AC appliances wherever you travel. Silent, lightweight and simple to use, Go Power! Inverters can be used in a wide range of applications including remote homes, RVs, boats and long haul trucks. It will operate most televisions and VCR’s, personal computers and small appliances including drills, sanders, grind­ers, mixers, blenders and microwaves. The inverter must have a greater power rating than the load to which it is providing power.
To get the most out of your power inverter, it must be installed and used properly.
Please read the instructions in this manual before installing and using your inverter.
2. Specifications
2.1 GP-600 Inverter 12V
Output 600 W Output wave form Modified Sine Wave Output voltage 115 VAC rms Regulation +5%-10% DC input voltage 10-15 V Low battery alarm ± 2% 10.5 V Low battery shut-down ± 2% 10 V Efficiency 80-90% Frequency ±1% 60 Hz No load current 0.2 A Surge rating 860 W Over thermal protection Yes Cooling fan Yes - continuous Overload protection Yes Dimensions (LxWxH) 230 x 85 x 51 mm
9” x 3.4” x 2”
Net weight 2.1 kg
4.6 lbs
Inverter Install Kit Included
10 3
Page 4
Go Power! Modified Sine Wave Inverter
Owner’s Manual
Go Power! Modified Sine Wave Inverter
Owner’s Manual
3. Features
3.1 Front view – GP-600
a) AC outlet
a) AC outlet:
Outlet sockets available: North America
b) ON/ OFF switch:
Leave in the OFF position during installation.
c) Power:
Lights green when GP-600 is on.
d) Fault:
Lights red when when fault has occured.
c) Power
d) Fault
b) ON/ OFF switch
The power inverter will also shut down if the input voltage exceeds 15 V. This protects the inverter against excessive input voltage. Although the power inverter incorporates protection against over voltage, it may still be damaged if the input voltage is allowed to exceed 20 V.
7. Troubleshooting
7.1 Common problems
a) Buzz in audio systems
Some inexpensive stereo systems will emit a buzzing noise from their loud speakers when operated from the power inverter. This is because the power supply in the device does not adequately filter the modified sine wave produced by the power inverter. The only solution is to use a sound system that incorporates a higher quality power supply.
b) Television interference
Operation of the power inverter can interfere with television reception on some channels. If this situation occurs, the following steps may help to alleviate the problem.
• Do not operate high power loads with the power inverter while watching television.
• Make sure that the antenna feeding your television provides an adequate (“snow free”) signal and that you are using good quality cable between the antenna and the television.
• Move the television as far away from the power inverter as possible.
• Keep the cables between the battery and the power inverter as short as possible and twist them together with about 2 to 3 twists per foot. This minimizes radiated interference from the cables.
7.2 Troubleshooting guide
Problem and Symptoms
Low AC output voltage 95-105 VAC.
Possible Cause
Using standard voltmeter. Overload.
Solution
Use true RMS averaging meter.
No output voltage and LED indicator is red.
No output voltage, LED indicator is red.
No output voltage, no lights.
4
Overload.
High input voltage.
Internal fuse open.
Reduce load.
Make sure that inverter is connected to 12 V battery. Check regulation of charging system. Reduce load.
Make sure that inverter is connected to 12 V battery. Check regulation of charging system.
9
Page 5
Go Power! Modified Sine Wave Inverter
Owner’s Manual
Go Power! Modified Sine Wave Inverter
Owner’s Manual
5. Operation
To operate the power inverter, turn it on using the ON/OFF switch on the front panel. The power inverter is now ready to deliver AC power to your loads. If you are operat­ing several loads from the power inverter, turn them on separately after the inverter has been turned ON. This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once.
5.1 Controls and indicators
The ON/OFF switch turns the control circuit in the power inverter ON and OFF. It does not disconnect power from the power inverter.
When the switch is in the OFF position, the power inverter draws no current from the battery. When the switch is in the ON position but with no load, the power idle current is approximately 1 A (see product specifications for exact current draw).
6. Operating limits
6.1 Overtemp
The fault LED will come on when the inverter has shut itself down because the inverter has become overheated. The power inverter may overheat because it has been operated at power levels above it’s rating, or because it has been installed in a location, which does not allow it to dissipate heat properly. The power inverter will restart automatically once it has cooled off.
6.2 Overload
The fault LED will come on when the power inverter has shut itself down because its output circuit has been short-circuited or drastically overloaded. Switch the ON/ OFF switch to OFF, correct the fault condition, and then switch the ON/OFF switch back to ON.
Some induction motors used in refrigerators, freezers, pumps and other motor oper­ated equipment require very high surge currents to start. The power inverter may not be able to start some of these motors, even though their rated current draw is within the power inverter.
3.1 Rear view – GP-600
b) Battery terminals
a) Ventilation port
a) Ventilation port:
Do not obstruct, allow at least 1 inch for air flow.
b) Battery terminals: Connect to 12 V battery or other 12 V power
source. Note that “+” is positive, “-” is negative. Reverse polarity connection will blow internal fuse and may damage inverter permanently.
Note: Minimum inverter DC cable & DC inverter fuse sizes, see section 4.3 and 4.4.
4. Installation
4.1 Where to install
The power inverter should be installed in a location that meets the following require­ments:
If the motor refuses to start, observe the battery voltage indicator while trying to start the motor. If the battery voltage indicator drops below 11 volts while the inverter is attempting to start the motor, this may be why the motor will not start. Make sure that the battery connections are good and that the battery is fully charged. If the connections are good and the battery is charged, but the voltage still drops below 11 volts, you may need to use a larger battery.
6.3 Input voltage
The power inverter will operate from input voltage ranging 10 V – 15 V. If the voltage drops below 10.7 V, an audible low battery warning will sound and the fault LED will be on. The power inverter will shut down if the input voltage drops below 10 V. This protects your battery from being over discharged.
a) Dry - Do not allow water to drip or splash on the inverter. b) Cool - Ambient air temperature should be between 0°C and 40°C (the cooler the
better).
c ) Ventilated - Allow at least two inches of clearance around the inverter for airflow.
Ensure the ventilation openings on the rear and bottom of the unit are not ob structed.
d) Safe - Do not install the inverter in the same compartment as batteries or in any
compartment capable of igniting flammable liquids such as gasoline.
e) Inverter should be located within 10 feet of the batteries.
58
Page 6
Go Power! Modified Sine Wave Inverter
Owner’s Manual
Go Power! Modified Sine Wave Inverter
Owner’s Manual
4.2 Hook-up and testing
To hook-up the inverter please follow these guidelines:
Caution
Do not connect this inverter and another AC source (generator or utility power) to the AC wiring or AC loads at the same time. Doing so will destroy the inverter and void the warranty, regardless whether the inverter is switched on or off. If you are using more than one AC source for the AC wiring or AC loads, it is highly recommended that you install an automatic transfer switch (GP-TS), available from Go-Power Electric Inc.
1. Unpack and inspect your Go Power! Inverter, check to see that the power switch is in the OFF position
2. Attach the DC inverter cables to the DC power input terminals on the rear panel of the power inverter. The (+) terminal is positive and (-) terminal is negative. Con nect the cables to the terminals by placing the lug connector at the base of the terminal and tightening the terminal screw or nut. Clamp the wires securely and ensure connections are tight.
Caution! A reverse polarity connection may permanently damage the inverter. Damage caused by reverse polarity connection is not covered by our warranty.
3. First connect the cable from the negative terminal of the inverter to the negative terminal of the battery. Make a secure connection.
Caution! Loose connections result in excessive voltage drop and may cause overheated wires and melted insulation. Ensure connections are tight.
4. Before proceeding further, carefully check that the cable you have just con nected is going from the negative terminal of inverter to the negative terminal of the power source (battery).
8. Set the power inverter switch to the OFF position. The power LED light may blink and go dim. The internal alarm may sound momentarily . This is normal. Plug the test load into the AC receptacle on the front panel of the inverter.
9. Set the power inverter switch to the ON position and turn the test load on; the inverter should supply power to the load. If you plan to measure the output voltage of the inverter, a true rms meter must be used for accurate readings.
4.3 Cables
Cables are included with the unit. The battery interconnect cables supplied with the GP­600 inverter are not fused. If these cables are used, it is recommended a 70 amp fuse is placed in-line with the positive wire. If user supplied cables are preferred, please use 8 ft or less of #6 Cable with a 70 Amp fuse. Install the inverter fuse into the positive lead. Fuse should be located within 12” of battery. Ensure all connections are tight and secure.
4.4 Inverter Fuse Example
GP-600 - 110 amp fuse with 10’ #4 wire
GP Inverter
GP Fuse
*Installation using two 12 volt batteries.
12 V Batteries
5. Install the inverter fuse into the positive lead. Fuse should be located within 12” of battery. Ensure all connections are tight and secure. (See 4.3)
6. Connect the cable from the positive terminal of inverter to the positive terminal of the battery. Make a secure connection. Check your polarity.
Caution! Connecting this inverter to AC distribution wiring or AC loads in which the neutral and ground are connected (bonded) will damage the unit and void the warranty.
7. Set the power switch to the ON position. Check that the power LED is ON, and if not, check your battery bank and the connections to the inverter.
Warning! You may observe a spark when you make this connection since current may flow to charge capacitors in the power inverter. Do not make this connection in the presence of flammable fumes, as explosion or fire may result.
GP Fuse
6 V Batteries
GP Inverter
*Installation using two 6 volt batteries.
76
Loading...