INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS
07
08
2.3.2 MOUNTING
Remember that this inverter is heavy! Please be careful when lifting out from the package.
[2]
The polarity of PV strings or on the inverter cannot be connected by reverse, otherwise
inverter could be damaged.
[3]
Step 2
Connect PV cable to DC connectors (Pic 9)
2.4.1 PV CONNECTION
Before connecting PV panels/strings to inverter, please make sure requirements are followed as below :
NOTE:There will be MC4 or Amphenol DC plugs in accessory box, the detailed connection as below:
• The minimum isolation resistance to ground of the PV string must
exceed 18.33kΩ in case of any shock hazard
• PV strings could not connect to earth/grounding conductor
• Use the DC plugs in the accessory box
• The total short-circuit current of PV string must not exceed
inverter’s max DC current
NOTE:
• Please use DC plugs and connectors in
GoodWe accessory box
• PV cable should be standard, 2.5-4mm
2
PV
cable
NOTE:
NOTE:
• PV cable must be tightly crimped into the
connectors
• For Amphenol connector, the limit buckle
cannot be pressed
• There will be a click sound if connectors are
inset correctly into DC plugs
• There will be a
click sound if
connectors are
inset correctly into
DC plugs
Prepare PV cables and DC plugs (Pic 8)
Screw the cap on and plug onto inverter side (Pic 10)
MC4 series
AMPHENOL series
2.5-4mm²
7mm
2.5-4mm²
7mm
Pic 8 Pic 9
2.4 ELECTRICAL WIRING CONNECTION
Pic 10
NOTE: Bearing capacity of the wall must be higher
than 30KG, otherwise may not be able to keep
inverter from dropping.
• Please use the mounting bracket as a template to
drill 6 holes on right positions (10mm in diameter,
and 80mm in depth) (Pic 4)
• Use expansion bolts in accessory box and fix the
mounting bracket onto the wall tightly
self-tapping
screws
Wall bracket Expansion pipe
Step 1
Pic 4
Step 2
Carry the inverter by holding the heating
sink on two sides and Place the inverter on
the mounting bracket. (Pic 5)
NOTE: Make sure the heat sink on inverter is
rightly joint with mounting bracket.
Pic 5
A lock could be used for anti-theft if it is
necessary for individual requirement.
(Pic 7)
Step 4
Pic 7
Step 3
Ground cable shall be connected to ground
plate on grid side (Pic 6)
Pic 6
Step 1 Step 2
Step 3
The inverter is suitable for mounting on concrete or other non-combustible surface only