Goodman Mfg PC50 User Manual

PRODUCT SPECIFICATIONS
PC
PACKAGED AIR CONDITIONERS
The PC50 Packaged Air Conditioner features energy­effi cient cooling and heating performance in one self- contained unit. This unit is housed in a heavy-gauge, galvanized-steel cabinet protected by a high-quality, UV-resistant powder-paint fi nish. The PC50 allows for ground-level or rooftop applications, and is approved for manufactured or modular homes.
Standard Features
• Energy-effi cient compressor with internal relief valve
• PSC blower motor
• Quiet horizontal discharge
• Copper tube/aluminum fi n coil
• Totally enclosed, permanently lubricated condenser fan motor
• Fully charged system
11 SEER, 50 HERTZ
4 AND 5 TONS
NOMINAL COOLING CAPACITY:
[13.6 KW TO 16.0 KW]
Cabinet Features
• Heavy-gauge galvanized-steel cabinet with attractive Architectural Gray powder-paint fi nish
• Fully insulated blower compartment with convenient access panels
• Louvered condenser coil protection
• Common footprint
Heat Kit Selection
• HKR5-12 (12 kW)
• HKR5-15 (15 kW)
• Above electric heat kits available as eld-installed options.
SS-PC50 www.goodmanmfg.com 7/09
Supersedes 1/08
P
A
RODUCT SPECIFICATIONS
NOMENCLATURE
P C 048 5
63,4,521
Product Category Engineering
P Packaged Unit Major/ Minor Revision
Type Electrical Data
C Air Conditioner 1 208/230 V, 1 Phase, 60 Hz H Heat Pump 2 220/240 V, 1 Phase, 50 Hz
3 208/230 V, 3 Phase, 60 Hz Nominal Capacity 4 460 V, 3 Phase, 60 Hz 48 4 Tons 5 380/415 V, 3 Phase, 50 Hz 60 5 Tons
G
7,8
2 www.goodmanmfg.com SS-PC50
SPECIFICATIONS
PC048-5 PC060-5
Cooling Capacity
Total BTU/h 46,400 54,700 Sensible BTU/h 33,300 39,400 SEER / EER 11.9 / 10.2 10.9 / 9.4 Decibels 80 80
Evaporator Motor
Type DD DD Wheel (D x W) 9 x 8 10 x 8 Nominal Cooling CFM 1,365 1,693 No. of Speeds 2 2 Horsepower - RPM 1/2 - 1075 3/4 - 1075
Evaporator Coil
Face Area (ft²) 6.2 7.0 Rows Deep/ Fins per Inch 4/14 4/14 Filter Size (ft²) (2) 20 x 20 x 1 (2) 20 x 20 x 1 Drain Size (NPT) 3/4” 3/4” Refrigerant Charge (oz.) 126 125
Condenser Fan / Coil
Horsepower - RPM 1/4 - 1075 1/4 - 1075 Fan Diameter/ # Fan Blades 22 / 4 22 / 4 Face Area (ft²) 17.8 19.1 Rows Deep/ Fins per Inch 2 / 16 2 / 16
Electrical Data
Voltage/Phase/ Frequency 380-415 / 3 / 50 Compressor RLA/LRA 7.4 / 50 10.3 / 65 Indoor Blower FLA 1.4 2.2 Outdoor Fan RLA 0.8 1.2 Total Unit Amps 8.9 11.4 Min. Circuit Ampacity ¹ 11.5 16.3 Max. Overcurrent Protection ² 20 amps 20 amps Ship Weight (lbs) 400 400
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. ² May use fuses or HACR-type circuit breakers of the same size as noted. Note: Always check the S&R plate for electrical data on the unit being installed.
P
RODUCT SPECIFICATIONS
SS-PC50 www.goodmanmfg.com 3
P
RODUCT SPECIFICATIONS
EXPANDED COOLING RATINGS
PC048-5G
Indoor
Air
SCFM WB
71 48.1 23.5 4.05 46.9 23.6 4.32 45.8 23.7 4.56 43.5 23.4 4.76 40.3 21.8 4.93
1194
1365
1536
67 45.0 29.5 3.92 43.9 29.5 4.18 42.8 29.7 4.41 40.7 29.3 4.60 37.7 27.3 4.77 63 42.1 33.9 3.80 41.1 33.9 4.04 40.1 34.1 4.26 38.1 33.7 4.45 35.3 31.4 4.61 59 41.2 35.3 3.71 40.2 35.4 3.96 39.2 35.6 4.17 37.3 35.1 4.35 34.5 32.8 4.50 71 52.1 26.4 4.16 50.8 26.5 4.44 49.6 26.7 4.68 47.1 26.3 4.89 43.6 24.6 5.06 67 48.7 33.1 4.02 47.6 33.1 4.29 46.4 33.4 4.52 44.1 32.9 4.72 40.8 30.7 4.89 63 45.6 38.1 3.90 44.5 38.1 4.15 43.4 38.4 4.37 41.3 37.8 4.57 38.2 35.3 4.73 59 44.6 39.7 3.81 43.6 39.8 4.06 42.5 40.0 4.28 40.4 39.5 4.46 37.4 36.9 4.62 71 53.6 28.6 4.20 52.4 28.6 4.47 51.1 28.8 4.72 48.5 28.4 4.93 45.0 26.5 5.11 67 50.2 35.7 4.06 49.0 35.8 4.33 47.8 36.0 4.56 45.4 35.5 4.76 42.1 33.2 4.94 63 47.0 41.1 3.93 45.9 41.1 4.19 44.7 41.4 4.41 42.5 40.9 4.61 39.4 38.2 4.77 59 46.0 42.9 3.84 44.9 42.9 4.09 43.8 43.8 4.31 41.6 41.6 4.50 38.5 38.5 4.66
Total
MBTU
75 85 95 105 115
Sens
MBTU
Watts
kWh
Total
MBTU
Sens
MBTU
Condenser Air Temperature
Watts
kWh
Total
MBTU
Sens
MBTU
Watts
kWh
Total
MBTU
Sens
MBTU
Watts
kWh
Total
MBTU
Sens
MBTU
Sensible heat capacities shown are based on 80°F DB entering air at the evaporator coil. For sensible heat capacities at other than 80°F DB, deduct 84 BTU/h per 100 CFM of evaporator coil air for each degree below 80°F, or add 84 BTU/h per 100 CFM of evaporator coil air per degree above 80°F.
Total MBTU/h 43.0 Sensible MBTU/h 33.0 Latent MBTU/h 10.0
Watts
kWh
PC060-5G
Indoor
Air
SCFM WB
71 56.7 27.7 5.23 55.3 27.8 5.57 54.0 28.0 5.87 51.3 27.6 6.12 47.5 25.8 6.35
1481
1693
1905
67 53.0 34.7 5.06 51.8 34.8 5.39 50.5 35.0 5.68 48.0 34.5 5.92 44.4 32.2 6.13 63 49.6 39.9 4.90 48.4 40.0 5.21 47.3 40.3 5.49 44.9 39.7 5.73 41.6 37.1 5.93 59 48.6 41.7 4.79 47.4 41.7 5.10 46.2 42.0 5.37 43.9 41.4 5.60 40.7 38.7 5.80 71 61.4 31.2 5.36 59.9 31.2 5.71 58.5 31.4 6.02 55.6 31.0 6.29 51.5 28.9 6.52 67 57.4 39.0 5.19 56.1 39.1 5.53 54.7 39.3 5.83 52.0 38.8 6.08 48.1 36.2 6.30 63 53.8 44.9 5.02 52.5 44.9 5.35 51.2 45.2 5.64 48.6 44.6 5.88 45.1 41.7 6.09 59 52.6 46.8 4.92 51.4 46.9 5.23 50.1 47.2 5.51 47.6 46.5 5.75 44.1 43.5 5.95 71 63.2 33.7 5.41 61.7 33.7 5.76 60.2 33.9 6.08 57.2 33.5 6.34 53.0 31.3 6.57 67 59.2 42.1 5.23 57.7 42.2 5.57 56.3 42.5 5.87 53.5 41.9 6.13 49.6 39.1 6.35 63 55.4 48.5 5.07 54.1 48.5 5.39 52.7 48.8 5.68 50.1 48.2 5.93 46.4 45.0 6.14 59 54.2 50.6 4.96 52.9 50.6 5.28 51.6 51.6 5.56 49.0 49.0 5.80 45.4 45.4 6.01
Total
MBTU
75 85 95 105 115
Sens
MBTU
Watts
kWh
Total
MBTU
Sens
MBTU
Sensible heat capacities shown are based on 80°F DB entering air at the evaporator coil. For sensible heat capacities at other than 80°F DB, deduct 84 BTU/h per 100 CFM of evaporator coil air for each degree below 80°F, or add 84 BTU/h per 100 CFM of evaporator coil air per degree above 80°F.
Total MBTU/h 50.7 Sensible MBTU/h 38.9 Latent MBTU/h 11.8
Condenser Air Temperature
Watts
kWh
Total
MBTU
Sens
MBTU
Watts
kWh
Total
MBTU
Sens
MBTU
Watts
kWh
Total
MBTU
Sens
MBTU
Watts
kWh
4 www.goodmanmfg.com SS-PC50
EVAPORATOR BLOWER SPECIFICATIONS
P
RODUCT SPECIFICATIONS
Model Speed Airfl ow
0.1 [0.25] 0.2 [0.5] 0.3 [0.75] 0.4 [1.0] 0.5 [1.25]
Low CFM [L/s] 1885 [890] 1840 [870] 1795 [850] 1675 [790] 1575 [740]
PC060-5A
High CFM [L/s] 2030 [960] 1955 [920] 1900 [900] 1760 [830] 1655 [780]
Low CFM [L/s] 1540 [730] 1450 [680] 1315 [620] 1215 [570] 1070 [500]
PC048-5A
High CFM [L/s] 1590 [750] 1490 [700] 1395 [660] 1280 [600] 1120 [530]
[ ] Designates metric measurements
Notes:
1. Data shown is dry coil. Wet coil pressure drop is approx.
2. 0.1” H2O, for two-row indoor coil; 0.2” H2O, for three-row indoor coil; and 0.3” H2O, for four-row indoor coil.
3. Data shown does not include fi lter pressure drop, approx. 0.08” H2O.
4. ALL MODELS SHOULD RUN NO LESS THAN 350 CFM/TON. USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM., See Repair Parts list.
5. Reduce airfl ow by 2% for 208-volt operation.
External Static Pressure In-Water [Mbar]
SS-PC50 www.goodmanmfg.com 5
P
RODUCT SPECIFICATIONS
DIMENSIONS
38½” [978 mm]
24.000
Model
Dimensions (Inches) Dimensions (mm)
WDH WDH
PCO48-5 66” 33” 38½” 1,676 838 978 PC060-5 66” 33” 38½” 1,676 838 978
6 www.goodmanmfg.com SS-PC50
SCHEMATIC WIRING DIAGRAMS
P
RODUCT SPECIFICATIONS
BK
PU
BK
RD
GR
BL
G
EBTDR
R
XFMR-R XFMR-C
C
NOTE #2
SPEED UP
BK
RD
GR
PU
RD
BK
BR
EM
BR
2 SPEED
FC
GR
NO
K1
COM
K1
NC
M1
M2
1
3
2
EMR
RD
RD
RD
BK
BR
BL
C
RCCF
PU
1
3
C
480
TR
BL
24V
BL
RD
BL
RD
BUSHING
WH
PLF 1
3
2 1
WH
9
6
8
5
4
BR
7
BR
PU
PU
BR
CM
BL
PU
F
PU
BL
BL
BL
YL
RD
RD
BK
BK
BK
BK
RD
BK
BK
YL
BK
T3
COMP
PU
3 8 0
Y
R G W1
W2
C
++
CONTROL BOX
­4 1 5
/ 3 /
5 0
T H E R M O S T A T
T3
L3
BK
L2
T2
C
L1
T1
RD
YL
RD
T1
T2
GR WH
BR BL
SEE NOTE #3
GND
YL
RD
L1
C
T1
M1
EBTDR
P
P L
L F
F 1
1
SUPPLY VOLTAGE
380-415/3/50
T2
COMP
T1
T3
NOTE#2
EM
EBTDR
4 5 6
THERMOSTAT
T2
C
RCCF
F
P
2
L F
3
1
2
CMR
1
3
FC
R
R W2 W1
C
24V
C
T3
CM
2
13
TR
C
G
EMREBTDR
G C
Y
L3
L2
MPONENT LEGEND
CO
C
CONTACTOR
CH
CRANKCASE HEATER
CM
CONDENSER MOTOR
COMP
COMPRESSOR
ECON
ECONOMIZER
EBTD
ELECTRONIC BLOWER TIME DELAY
R
RELAY
EM
EVAPORATOR MOTOR
EMR
EVAPORATOR MOTOR RELAY
FC
FAN CAPACITOR
GND
EQUPIMENT GROUND
LVJB
LOW VOLTAGE JUNCTION BOX
PLF
FEMALE PLUG / CONNECTOR
RCCF
RUN CAPACITOR FOR COMPRESSOR AND FAN
TR
TRANSFORMER
NOTES:
1. REPLACEMENT WIRE MUST BE SAME SIZE AND TYPE INSULATION AS ORIGINAL (AT LEAST 105°C) USE COPPER CONDUCTOR ONLY.
2. TO CHANGE EVAPORATOR MOTOR SPEED REPLACE LEAD ON EMR "1" WITH LEAD ON EBTDR "M1" OR "M2"
3. USE COPPER CONDUCTORS ONLY ++ USE N.E.C. CLASS 2 WIRE
C
SEE UNIT RATING PLATE FOR TYPE AND SIZE
OF OVER CURRENT PROTECTION
F
ACTORY WIRING LINE VOLTAGE LOW VOLTAGE OPTINAL HIGH VOLTAGE
FIELD WIRING HIGH VOLTAGE LOW VOLTAGE
W
IRE CODE BK BLACK BL BLUE BR BROWN GR GREEN OR ORANGE PU PURPLE RD RED WH WHITE YL YELLOW
380-415/3/50 0140G00588 REV. A
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources
Wiring is subject to change. Always re-
may be present. Failure to do so may cause property damage, personal injury, or death.
WARNING
fer to the wiring diagram on the unit for
the most up-to-date wiring
SS-PC50 www.goodmanmfg.com 7
P
RODUCT SPECIFICATIONS
ACCESSORIES
Item # Description
PCCP101-103 Roof Curb for PC- Electric/Electric Package Unit PCP101-103 Downfl ow Plenum Kit for PC- Package Unit PCP101-103R8 Downfl ow Plenum Kit for PC- Package Unit with R-8 Insulation PCE101-103 Downfl ow Economizer for PC- Package Unit to be used with PCP101-103 PCMD101-103 Manual Damper for PC- Package Unit to be used with PCP101-103 PCMDM101-103 Motorized Damper for PC- Package Unit to be used with PCP101-103 PCMDH101-103 Manual Damper for PC- Package Unit Horizontal Applications SQRPCH101 Square-to-Round Adapters for PC- Package Unit 16” & 14” SQRPCH102-103 Square-to-Round Adapters for PC- Package Unit 18” & 14” SQRPC101 Square-to-Round Adapter for PC- Package Unit for use with PCCP101-103 Curb 16” Rounds SQRPC102-103 Square-to-Round Adapter for PC- Package Unit for use with PCCP101-103 Curb 18” Rounds PCFR101-103 External Horizontal Filter Rack PCEF101-103 Elbow & Flashing with R-8 Liner for PC- Package Unit
The above accessories are offered by McDaniel Metals • Main: (281) 987-8400 • Fax: (281) 987-9494
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifi cations or designs without notice
or without incurring obligations.
8 www.goodmanmfg.com SS-PC50
© 2007-2009 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.
Loading...