•Refer to Service Manual RS6100004 for installation, op-
eration, and troubleshooting information.
•All safety information must be followed as provided in the
Service Manual.
Models listed on page 3.
®
This manual is to be used by qualified HVAC technicians only. Goodman
does not assume any responsibility for property damage or personal injury
due to improper service procedures performed by an unqualified person.
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
GROUND MAY RESULT IN PRODUCT DAMAGE, PERSONAL INJURY OR DEATH.
2
DISCONNECT ALL POWER BEFORE SERVICING. MULTIPLE POWER
SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
ONLY INDIVIDUALS MEETING THE REQUIREMENTS OF AN "ENTRY
LEVEL TECHNICIAN" AS SPECIFIED BY THE AIR CONDITIONING AND
REFRIGERATION INSTITUTE (ARI) MAY USE THIS INFORMATION. ATTEMPTING TO INSTALL OR REPAIR THIS UNIT WITHOUT SUCH BACK-
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
* Indicates minor revision & is not used for order entry or inventory management
TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY,
WARNING
WARNING
WARNING
WARNING
HAZARDOUS CONDITIONS MAY RESULT FROM THE USE OF SUCH NON-APPROVED DEVICES.
OR DEATH, DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF
THIS APPLIANCE.
DO NOT CONNECT OR USE ANY DEVICE THAT IS NOT DESIGN CERTIFIED BY GOODMAN FOR USE WITH THIS UNIT. SERIOUS PROPERTY
DAMAGE, PERSONAL INJURY, REDUCED UNIT PERFORMANCE AND/OR
3
PRODUCT DESIGN
GSH14 SEER split system heat pump models are available
in 1 1/2 through 5 ton sizes. They are designed for 208/230
volt single phase applications.
Air is drawn through the outdoor coil by a propeller fan, and is
discharged vertically out the top of the unit. No additional
restriction (ductwork) shall be applied.
The suction and liquid line connections are of the sweat type
for field piping with refrigerant type copper. Non-back seating
valves are factory installed to accept the field run copper.
The total refrigerant charge for a normal installation is factory
installed in the condensing unit. This charge is for the matching evaporator coil and a 15 foot refrigerant line set.
Systems should be properly sized by heat gain and loss
calculations made according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent. It is
the contractors responsibility to ensure the system has adequate capacity to heat or cool the conditioned space.
GSH14 units use high-efficiency Copeland
sors and there are a number of design characteristics which
are different from the scroll compared to the traditional reciprocating compressor.
Due to their design Scroll compressors are inherently more
tolerant of liquid refrigerant.
GSH14 model heat pumps do not use a reversing relay to
energize the reversing valve. The reversing valve is energized
in the cooling cycle through the "O" terminal on the room
thermostat.
This unit is for outdoor installation only. Refer to minimum
figure for clearances from the sides of the unit to full walls
and other objects.
NOTE: This unit cannot be completely enclosed. At least
one side must be unrestricted.
These clearances will help avoid air recirculation. If installing
two or more units at the same location, allow at least 24
inches between units. If only one side is restricted (for example, against the outside wall of a house), the unit may be
placed as close as 8" to that one wall.
®
scroll compres-
DO NOT locate the unit:
* Directly under a vent termination for a gas appliance.
* Within 3 feet of a clothes drier vent
* Where the refreezing of defrost water would create
a hazard
* Where water may rise into the unit.
NOT
RECOMMENDED
BBB
AA
A
AAAAA
C
AA
AA
C
AA
CC
B
AA
OK!
OK!
OK!
ModelDimensions - W x D x H
GSH140181A*29 x 29 x 34¼
GSH140241A*29 x 29 x 38¼
OK!
OK!
OK!
GSH140301A*29 x 29 x 38¼
GSH140361A*35½ x 35½ x 38¼
GSC140421A*35½ x 35½ x 38¼
GSC140481A*35½ x 35½ x 38¼
GSC140601A*35½ x 35½ x 38¼
Maximum Overcurrent Device
Electrical Conduit Size
Power Supply (Inches)1/2 or 3/41/2 or 3/41/2 or 3/41/2 or 3/41/2 or 3/41/2 or 3/41/2 or 3/4
Approximate Shipping Weight199207207242242266280
(1)
Wire size should be determined in acordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
(2)
May use fuses or HACR type Circuit Breakers of the same size as noted.
(1)
(2)
11.814.716.318.321.527.827.3
20202030304040
GSH140241A*
GSH140301A*
GSH140361A*
GSH140421A*
GSH140481A*
GSH140601A*
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/
circuit breakers and wires in accordance with all national and/or local electrical codes. Use copper wire only.
LO PR616571766569758067717883707582877479869176818994
Shaded area is AR I Ratin g Co ndit ionsIDB : En tering Ind oor Dry Bu lb T em pe ra tureKW = Tot al sys tem powerAMPS=out door un it amps (comp. +fan)