Goodman Mfg GSC13 User Manual 2

GSC13
Split SyStem Air Conditioner
13 Seer / r-22
to 5 tonS
Nomenclature ....................................... 2
Product Specications .......................... 3
Expanded Cooling Data ....................... 4
AHRI Ratings ....................................... 18
Dimensions ......................................... 18
Wiring Diagram .................................. 19
Accessories .......................................... 20
Standard Features
• Energy-efcient compressor
Quiet condenser fan system
• Factory-installed liquid-line lter drier
• Copper tube/aluminum n coil
For use with R-22 refrigerant;
charged with inert gas for shipping
R-22 piston kit included
Brass liquid and suction service
valves with sweat connections
Contactor with lug connections
Ground lug connection
ETL Listed
SS-GSC13 www.goodmanmfg.com 11/13
Cabinet Features
Louver design sound control top
Steel louver coil guard
Heavy-gauge galvanized-steel cabinet
Attractive Architectural Gray powder-paint nish with 500-hour salt-spray approval
When properly anchored, meets the 2010
Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
* Complete warranty details available from your
local dealer or at www.goodmanmfg.com.
Supersedes 9/13
P
Brand Engineering *
G
Goodman® (Standard
Minor Revision
Feature Set Models)
Engineering *
Product Category Major Revision
S Split System
Electrical
Unit Type 1 208/230 V, 1 Phase, 60 Hz
C Condenser R-22
H Heat Pump R-22 Nominal Capacity
018 1½ Tons 042 3½ Tons
Efficiency 024 2 Tons 048 4 Tons
13 13 SEER 030 2½ Tons 060 5 Tons
036 3 Tons
* Neither used for order entry
or inventory management.
11
A
S
2
1
G
C3036
6,7,8134,5
9110
A
roduct SPecificationS

nomenClAture

2 www.goodmanmfg.com SS-GSC13

SpeCifiCAtionS

P
roduct SPecificationS
GSC13
0181G*
Cooling Capacities
Tonnage 2 3 4 5
Decibels 76 76 72 75 76 76 77
Compressor
RLA 6.8 10.8 13.5 13.4 15.4 19.2 21.8
LRA 40 56 68 74 87 112 137
Condenser Fan Motor
Horsepower 1/8 1/8 1/8 1/6 ¼ ¼ ¼
FLA 0.65 0.65 0.7 1.1 1.5 1.5 1.5
Refrigeration System
Refrigerant Line Size
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Line Size (“O.D.) ¾" ¾" ¾" ⅞" 1⅛" 1⅛" 1⅛"
Refrigerant Connecon Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Valve Size (“O.D.) ³ ¾" ¾" ¾" ¾" ³ ¾" ³ ⅞" 4 ⅞" 4
Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge 87 77 66 77 108 128 118
Electrical Data
AC Volts-Hz 208-230/ 60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60
Min. Circuit Ampacity¹ 9.2 14.2 17.6 17.9 20.8 25.5 28.8
Max. Overcurrent Device² 15 25 30 30 35 40 50
Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253
Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"
Equipment Weight (lbs) 116 116 142 141 141 176 207
Ship Weight (lbs) 130 130 159 159 159 194 225
GSC13
0241F*
GSC13
0301E*
GSC13
0361G*
GSC13
0421C*
GSC13
0481C*
GSC13
0601D*
¹ Wire size should be determined in accordance with Naonal Electrical Codes; extensive wire runs will require larger wire sizes ² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted. ³ Installer will need to supply ¾” to ⅞” adapters for sucon line connecons. ⁴ Installer will need to supply ⅞” to 1⅛” adapters for sucon line connecons.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Charge with refrigerant charge listed on S&R plate; 15’ of ⅜” line included in this charge. System charge must be adjusted per Installaon Instrucons Final Charge Procedure.
SS-GSC13 www.goodmanmfg.com 3
P
roduct SPecificationS
expAnded rAtinGS — GSC130181G*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 16.4 17.0 18.6 - 15.6 16.2 17.7 - 14.4 15.0 16.4 -
22 20 17 12 22 20 17 12 22 20 17 11 20 19 15 11
∆T 22 20 16 11 22 20 17 11
kW 1.05 1.07 1.11 1.15 1.14 1.17 1.21 1.25 1.22 1.25 1.29 1.34 1.29 1.32 1.37 1.42 1.35 1.38 1.43 1.49 1.40 1.44 1.49 1.54
4.4 4.5 4.6 4.8 4.7 4.8 5.0 5.1 5.1 5.2 5.4 5.6 5.4 5.5 5.7 5.9 5.7 5.9 6.1 6.3 6.1 6.2 6.4 6.6
Amps
HI PR 135 146 154 161 152 164 173 180 173 186 196 205 197 212 224 233 222 238 252 263 245 263 278 290
LO PR 61 65 71 76 65 69 75 80 67 72 78 83 71 75 82 88 74 79 86 92 77 82 89 95
MBh 17.9 18.5 20.0 21.5 17.5 18.0 19.5 21.0 17.1 17.6 19.1 20.5 16.7 17.2 18.6 20.0 15.9 16.3 17.7 19.0 14.7 15.1 16.4 17.6
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
∆T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10
kW 1.06 1.08 1.12 1.16 1.15 1.18 1.22 1.26 1.23 1.26 1.30 1.35 1.30 1.33 1.38 1.43 1.36 1.39 1.45 1.50 1.41 1.45 1.50 1.56
Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.3 6.1 6.3 6.5 6.7
HI PR 137 147 155 162 154 165 174 182 175 188 198 207 199 214 226 236 224 241 254 265 247 266 281 293
LO PR 62 66 72 77 65 70 76 81 68 72 79 84 71 76 83 88 75 80 87 93 77 82 90 96
4.4 4.5 4.6 - 4.7 4.8 5.0 - 5.1 5.2 5.4 - 5.4 5.5 5.7 - 5.7 5.9 6.1 - 6.1 6.2 6.4 -
∆T 19 17 13 - 19 17 13 - 19 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
MBh 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.1 15.6 17.1 - 14.7 15.2 16.7 - 14.0 14.5 15.9 - 12.9 13.4 14.7 -
kW 1.01 1.03 1.07 - 1.10 1.12 1.16 - 1.17 1.20 1.25 - 1.24 1.27 1.32 - 1.30 1.33 1.38 - 1.35 1.38 1.43 -
HI PR 130 140 148 - 146 157 166 - 166 179 189 - 189 203 215 - 213 229 242 - 235 253 267 -
Amps 4.2 4.3 4.5 - 4.6 4.7 4.8 - 4.9 5.0 5.2 - 5.2 5.4 5.5 - 5.5 5.7 5.9 - 5.9 6.0 6.2 -
LO PR 59 63 68 - 62 66 72 - 65 69 75 - 68 72 79 - 71 76 83 - 74 78 86 -
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
MBh 17.1 17.7 19.4 - 16.7 17.3 19.0 - 16.3 16.9 18.5 - 15.9 16.5 18.1 - 15.1 15.7 17.2 - 14.0 14.5 15.9 -
kW 1.04 1.06 1.10 - 1.13 1.15 1.20 - 1.21 1.24 1.28 - 1.28 1.31 1.36 - 1.34 1.37 1.42 - 1.39 1.42 1.47 -
HI PR 134 144 152 - 150 162 171 - 171 184 194 - 195 210 221 - 219 236 249 - 242 261 275 -
Amps 4.3 4.4 4.6 - 4.7 4.8 4.9 - 5.0 5.2 5.3 - 5.4 5.5 5.7 - 5.7 5.8 6.0 - 6.0 6.2 6.4 -
LO PR 61 65 71 - 64 68 75 - 67 71 77 - 70 75 81 - 73 78 85 - 76 81 88 -
MBh 17.6 18.3 20.0 - 17.2 17.9 19.6 - 16.8 17.4 19.1
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
kW 1.05 1.07 1.11 - 1.14 1.17 1.21 - 1.22 1.25 1.29 - 1.29 1.32 1.37 - 1.35 1.38 1.43 - 1.40 1.44 1.49 -
HI PR 135 146 154 - 152 164 173 - 173 186 196 - 197 212 224 - 221 238 252 - 245 263 278 -
Amps
LO PR 61 65 71 - 65 69 75 - 67 72 78 - 71 75 82 - 74 79 86 - 77 82 89 -
MBh 16.1 16.5 17.9 19.2 15.7 16.2 17.5 18.8 15.3 15.8 17.1 18.3 15.0 15.4 16.7 17.9 14.2 14.6 15.8 17.0 13.2 13.5 14.7 15.7
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆T 22 20 17 12 22 21 17 12 22 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11
kW 1.02 1.04 1.08 1.12 1.11 1.13 1.17 1.22 1.19 1.21 1.26 1.30 1.25 1.28 1.33 1.38 1.31 1.34 1.39 1.44 1.36 1.40 1.45 1.50
Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.8 5.0 5.0 5.1 5.2 5.4 5.3 5.4 5.6 5.8 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.5
HI PR 131 141 149 156 147 159 168 175 168 180 191 199 191 206 217 226 215 231 244 255 237 255 270 281
LO PR 59 63 69 74 63 67 73 78 65 70 76 81 69 73 80 85 72 77 84 89 74 79 86 92
MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 20.3 16.6 17.1 18.5 19.9 16.2 16.7 18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
525
600
70
675
525
600
75
675
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
4 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
expAnded rAtinGS — GSC130181G* (Cont.)
P
roduct SPecificationS
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
MBh 16.4 16.7 17.9 19.1 16.0 16.3 17.4 18.6 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 14.5 14.8 15.8 16.9 13.4 13.7 14.6 15.6
S/T 0.86 0.81 0.66 0.5 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.5 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.6 0.99 0.93 0.76 0.57
∆T 25 24 21 16 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 23 22 19 15
kW 1.03 1.05 1.09 1.1 1.12 1.14 1.19 1.23 1.20 1.22 1.27 1.3 1.27 1.30 1.34 1.39 1.32 1.36 1.41 1.5 1.37 1.41 1.46 1.51
Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.9 5.1 5.0 5.1 5.3 5.5 5.3 5.4 5.6 5.8 5.6 5.8 6.0 6.2 6.0 6.1 6.3 6.5
HI PR 133 143 151 157.3 149 160 169 177 169 182 192 200.8 193 208 219 229 217 234 247 257.2 240 258 272 284
LO PR 60 64 70 74.3 63 68 74 79 66 70 77 81.6 69 74 81 86 73 77 84 89.9 75 80 87 93
MBh 17.7 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 15.7 16.0 17.1 18.3 14.5 14.8 15.8 16.9
S/T 0.90 0.84 0.68 0.5 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.5 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.6 1.00 0.96 0.78 0.59
∆T 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 24 23 20 16 22 22 19 15
kW 1.06 1.08 1.12 1.2 1.15 1.18 1.22 1.26 1.23 1.26 1.30 1.4 1.30 1.33 1.38 1.43 1.36 1.40 1.45 1.5 1.41 1.45 1.50 1.56
Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.3 6.1 6.3 6.5 6.7
HI PR 137 147 155 162.2 154 165 174 182 175 188 198 207.0 199 214 226 236 224 241 254 265.2 247 266 281 293
LO PR 62 66 72 76.6 65 70 76 81 68 72 79 84.2 71 76 83 88 75 80 87 92.6 77 82 90 96
20.3 17.0 17.4 18.5 19.8 16.1 16.5 17.6 18.8 14.9 15.3 16.3 17.4
MBh 18.3 18.7 19.9 21.3 17.8 18.2 19.5 20.8 17.4 17.8 19.0
S/T 0.94 0.88 0.72 0.5 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.6 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.6 1.00 1.00 0.82 0.62
∆T 23 22 19 16 24 23 20 16 24 23 20 16 23 23 20 16 22 22 20 16 20 21 18 15
kW 1.07 1.09 1.13 1.2 1.16 1.19 1.23 1.27 1.24 1.27 1.32 1.4 1.31 1.34 1.39 1.45 1.37 1.41 1.46 1.5 1.43 1.46 1.52 1.57
4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.2 5.2 5.3 5.5 5.7 5.5 5.6 5.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8
Amps
HI PR 138 149 157 163.8 155 167 176 184 176 190 200 209.0 201 216 228 238 226 243 257 267.8 250 269 284 296
LO PR 63 67 73 77.4 66 70 77 82 69 73 80 85.0 72 77 84 89 76 80 88 93.6 78 83 91 97
MBh 16.6 17.0 17.8 19.0 16.3 16.6 17.4 18.5 15.9 16.2 16.9 18.1 15.5 15.8 16.5 17.6 14.7 15.0 15.7 16.8 13.6 13.9 14.5 15.5
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73
∆T 26 26 25 21 27 26 25 21 27 26 25 22 27 26 25 22 26 26 25 21 24 24 23 20
kW 1.04 1.06 1.10 1.14 1.13 1.15 1.20 1.24 1.21 1.24 1.28 1.33 1.28 1.31 1.36 1.41 1.34 1.37 1.42 1.47 1.39 1.42 1.47 1.53
Amps 4.3 4.4 4.6 4.7 4.7 4.8 4.9 5.1 5.0 5.2 5.3 5.5 5.4 5.5 5.7 5.9 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6
HI PR 134 144 152 159 150 162 171 178 171 184 194 203 195 210 221 231 219 236 249 260 242 261 275 287
LO PR 61 65 71 75 64 68 74 79 67 71 77 82 70 74 81 87 73 78 85 91 76 81 88 94
MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 20.1 17.2 17.5 18.4 19.6 16.8 17.1 17.9 19.1 15.9 16.2 17.0 18.2 14.8 15.0 15.8 16.8
S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76
26 26 24 21 26 26 25 21 24 25 24 21 23 23 23 20
∆T 26 26 24 21 26 26 24 21
kW 1.07 1.09 1.13 1.17 1.16 1.19 1.23 1.27 1.24 1.27 1.32 1.36 1.31 1.34 1.39 1.45 1.37 1.41 1.46 1.51 1.43 1.46 1.52 1.57
4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.2 5.2 5.3 5.5 5.7 5.5 5.6 5.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8
Amps
HI PR 138 149 157 164 155 167 176 184 176 190 200 209 201 216 228 238 226 243 257 268 250 269 284 296
LO PR 63 67 73 77 66 70 77 82 69 73 80 85 72 77 84 89 76 80 88 94 78 83 91 97
MBh 18.6 18.9 19.8 21.2 18.1 18.5 19.4 20.7 17.7 18.1 18.9 20.2 17.3 17.6 18.4 19.7 16.4 16.7 17.5 18.7 15.2 15.5 16.2 17.3
S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80
∆T 25 25 23 20 25 25 23 20 24 25 23 20 24 24 24 20 22 23 23 20 21 21 22 19
kW 1.08 1.10 1.14 1.18 1.17 1.20 1.24 1.29 1.25 1.28 1.33 1.38 1.32 1.36 1.41 1.46 1.39 1.42 1.47 1.53 1.44 1.48 1.53 1.59
Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.3 5.2 5.3 5.5 5.7 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.5 6.2 6.4 6.6 6.8
HI PR 140 150 159 165 157 169 178 186 178 192 202 211 203 218 231 240 228 246 259 271 252 271 287 299
LO PR 63 67 73 78 67 71 78 83 69 74 81 86 73 78 85 90 76 81 89 94 79 84 92 98
600
85
675
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
525
600
80
675
525
SS-GSC13 www.goodmanmfg.com 5
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
P
roduct SPecificationS
expAnded rAtinGS — GSC130241f*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 20.8 21.5 23.6 - 19.7 20.5 22.4 - 18.3 19.0 20.8 -
20 19 15 10 20 19 15 11 20 18 15 10 19 17 14 10
∆T 20 18 15 10 20 19 15 10
kW 1.54 1.58 1.63 1.69 1.67 1.71 1.78 1.84 1.79 1.84 1.90 1.97 1.90 1.95 2.02 2.09 1.99 2.04 2.11 2.19 2.07 2.12 2.20 2.28
7.2 7.3 7.5 7.8 7.7 7.8 8.1 8.3 8.2 8.4 8.6 8.9 8.7 8.9 9.2 9.5 9.2 9.4 9.7 10.0 9.7 9.9 10.2 10.5
Amps
HI PR 140 150 159 166 157 169 178 186 178 192 203 211 203 218 231 241 228 246 260 271 252 272 287 299
LO PR 59 63 69 74 63 67 73 78 65 69 76 81 69 73 80 85 72 77 84 89 74 79 86 92
MBh 22.7 23.4 25.3 27.2 22.2 22.8 24.7 26.5 21.7 22.3 24.1 25.9 21.1 21.8 23.6 25.3 20.1 20.7 22.4 24.0 18.6 19.1 20.7 22.2
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.94 0.84 0.64 0.41
∆T 19 18 14 10 19 18 15 10 19 18 15 10 19 18 15 10 19 18 14 10 18 17 14 9
kW 1.55 1.59 1.65 1.71 1.69 1.73 1.79 1.86 1.81 1.85 1.92 1.99 1.92 1.96 2.04 2.11 2.01 2.06 2.13 2.21 2.09 2.14 2.22 2.30
HI PR 141 152 160 167 158 170 180 188 180 194 205 213 205 221 233 243 231 248 262 273 255 274 290 302
Amps 7.3 7.4 7.6 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.7 9.0 8.8 9.0 9.2 9.5 9.3 9.5 9.7 10.1 9.7 10.0 10.3 10.6
LO PR 60 64 70 74 63 68 74 79 66 70 77 82 69 74 80 86 73 77 84 90 75 80 87 93
7.2 7.3 7.5 - 7.7 7.8 8.1 - 8.2 8.4 8.6 - 8.7 8.9 9.2 - 9.2 9.4 9.7 - 9.7 9.9 10.2 -
∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
S/T 0.67 0.56 0.38 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.76 0.64 0.44 -
MBh 20.0 20.8 22.7 - 19.6 20.3 22.2 - 19.1 19.8 21.7 - 18.6 19.3 21.1 - 17.7 18.3 20.1 - 16.4 17.0 18.6 -
kW 1.48 1.52 1.57 - 1.61 1.65 1.71 - 1.73 1.77 1.83 - 1.83 1.87 1.94 - 1.91 1.96 2.03 - 1.99 2.04 2.11 -
HI PR 134 144 152 - 150 162 171 - 171 184 194 - 195 210 221 - 219 236 249 - 242 261 275 -
Amps 7.0 7.1 7.3 - 7.5 7.6 7.8 - 8.0 8.1 8.4 - 8.4 8.6 8.9 - 8.9 9.1 9.4 - 9.4 9.6 9.8 -
LO PR 57 61 66 - 60 64 70 - 63 67 73 - 66 70 77 - 69 73 80 - 71 76 83 -
∆T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 -
S/T 0.69 0.58 0.40 - 0.71 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.79 0.66 0.46 -
MBh 21.7 22.5 24.6 - 21.2 22.0 24.1 - 20.7 21.4 23.5 - 20.2 20.9 22.9 - 19.2 19.9 21.8 - 17.8 18.4 20.2 -
kW 1.52 1.56 1.62 - 1.66 1.70 1.76 - 1.78 1.82 1.89 - 1.88 1.93 2.00 - 1.97 2.02 2.09 - 2.05 2.10 2.17 -
HI PR 138 149 157 - 155 167 176 - 176 190 200 - 201 216 228 - 226 243 257 - 250 269 284 -
Amps 7.2 7.3 7.5 - 7.6 7.8 8.0 - 8.2 8.3 8.6 - 8.6 8.8 9.1 - 9.1 9.3 9.6 - 9.6 9.8 10.1 -
LO PR 59 63 68 - 62 66 72 - 65 69 75 - 68 72 79 - 71 76 83 - 74 78 86 -
MBh 22.3 23.2 25.4 - 21.8 22.6 24.8 - 21.3 22.1 24.2
∆T 17 14 11 - 17 14 11 - 17 14 11 - 17 15 11 - 17 14 11 - 16 13 10 -
S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -
kW 1.54 1.58 1.63 - 1.67 1.71 1.78 - 1.79 1.84 1.90 - 1.90 1.95 2.02 - 1.99 2.04 2.11 - 2.07 2.12 2.19 -
HI PR 140 150 159 - 157 169 178 - 178 192 202 - 203 218 231 - 228 246 259 - 252 271 287 -
Amps
LO PR 59 63 69 - 63 67 73 - 65 69 76 - 69 73 80 - 72 76 84 - 74 79 86 -
MBh 20.4 21.0 22.7 24.4 19.9 20.5 22.2 23.8 19.4 20.0 21.6 23.2 18.9 19.5 21.1 22.7 18.0 18.5 20.1 21.5 16.7 17.2 18.6 19.9
S/T 0.76 0.68 0.51 0.33 0.78 0.70 0.53 0.34 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.87 0.78 0.59 0.38
∆T 20 19 15 11 20 19 15 11 20 19 15 11 21 19 16 11 20 19 15 11 19 17 14 10
kW 1.50 1.53 1.59 1.65 1.63 1.67 1.73 1.79 1.74 1.79 1.85 1.92 1.85 1.89 1.96 2.03 1.93 1.98 2.05 2.13 2.01 2.06 2.13 2.21
Amps 7.0 7.2 7.4 7.6 7.5 7.7 7.9 8.1 8.0 8.2 8.4 8.7 8.5 8.7 8.9 9.2 9.0 9.2 9.4 9.7 9.4 9.6 9.9 10.2
HI PR 135 146 154 161 152 164 173 180 173 186 196 205 197 212 224 233 222 238 252 263 245 263 278 290
LO PR 58 61 67 71 61 65 71 75 63 67 74 78 67 71 77 82 70 74 81 86 72 77 84 89
MBh 22.1 22.7 24.6 26.4 21.5 22.2 24.0 25.8 21.0 21.7 23.4 25.2 20.5 21.1 22.9 24.5 19.5 20.1 21.7 23.3 18.1 18.6 20.1 21.6
S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.81 0.61 0.39
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
700
800
70
900
700
800
75
900
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
6 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
expAnded rAtinGS — GSC130241f* (Cont.)
P
roduct SPecificationS
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
MBh 20.7 21.2 22.6 24.2 20.2 20.7 22.1 23.6 19.8 20.2 21.6 23.1 19.3 19.7 21.0 22.5 18.3 18.7 20.0 21.4 17.0 17.3 18.5 19.8
S/T 0.83 0.78 0.63 0.5 0.86 0.81 0.66 0.49 0.88 0.83 0.67 0.5 0.91 0.85 0.69 0.52 0.94 0.89 0.72 0.5 0.95 0.89 0.73 0.54
∆T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 21 20 18 14
kW 1.51 1.55 1.60 1.7 1.64 1.68 1.74 1.81 1.76 1.80 1.87 1.9 1.86 1.91 1.98 2.05 1.95 2.00 2.07 2.2 2.03 2.08 2.15 2.23
Amps 7.1 7.2 7.4 7.7 7.6 7.7 7.9 8.2 8.1 8.3 8.5 8.8 8.6 8.8 9.0 9.3 9.0 9.2 9.5 9.8 9.5 9.7 10.0 10.3
HI PR 137 147 155 162.2 154 165 174 182 175 188 198 207.0 199 214 226 236 224 241 254 265.2 247 266 281 293
LO PR 58 62 68 72.1 62 66 72 76 64 68 74 79.2 67 72 78 83 70 75 82 87.2 73 78 85 90
MBh 22.5 22.9 24.5 26.2 21.9 22.4 23.9 25.6 21.4 21.9 23.4 25.0 20.9 21.3 22.8 24.4 19.8 20.3 21.7 23.2 18.4 18.8 20.1 21.4
S/T 0.86 0.81 0.66 0.5 0.89 0.84 0.68 0.51 0.91 0.86 0.70 0.5 0.94 0.88 0.72 0.54 0.98 0.92 0.75 0.6 0.99 0.93 0.75 0.56
∆T 22 21 18 15 22 22 19 15 22 22 19 15 23 22 19 15 22 21 19 15 21 20 17 14
kW 1.55 1.59 1.65 1.7 1.69 1.73 1.79 1.86 1.81 1.85 1.92 2.0 1.92 1.96 2.04 2.11 2.01 2.06 2.13 2.2 2.09 2.14 2.22 2.30
Amps 7.3 7.4 7.6 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.7 9.0 8.8 9.0 9.2 9.5 9.3 9.5 9.7 10.1 9.7 10.0 10.3 10.6
HI PR 141 152 160 167.2 158 170 180 188 180 194 205 213.4 205 221 233 243 231 248 262 273.4 255 274 290 302
LO PR 60 64 70 74.3 63 68 74 79 66 70 77 81.6 69 74 81 86 73 77 84 89.8 75 80 87 93
25.7 21.5 22.0 23.5 25.1 20.4 20.9 22.3 23.8 18.9 19.3 20.7 22.1
MBh 23.1 23.6 25.2 27.0 22.6 23.1 24.7 26.4 22.0 22.5 24.1
S/T 0.90 0.85 0.69 0.5 0.93 0.88 0.71 0.53 0.96 0.90 0.73 0.5 1.00 0.93 0.75 0.56 1.00 0.96 0.78 0.6 1.00 0.97 0.79 0.59
∆T 21 20 18 14 22 21 18 14 22 21 18 14 22 21 18 14 21 21 18 14 19 19 17 13
kW 1.57 1.60 1.66 1.7 1.70 1.75 1.81 1.88 1.83 1.87 1.94 2.0 1.93 1.98 2.05 2.13 2.03 2.08 2.15 2.2 2.10 2.16 2.24 2.32
7.3 7.5 7.7 7.9 7.8 8.0 8.2 8.4 8.4 8.5 8.8 9.1 8.9 9.0 9.3 9.6 9.3 9.5 9.8 10.1 9.8 10.0 10.3 10.7
Amps
HI PR 142 153 162 168.9 160 172 182 189 182 196 207 215.5 207 223 235 245 233 251 265 276.1 257 277 293 305
LO PR 61 65 70 75.1 64 68 74 79 67 71 77 82.4 70 74 81 87 73 78 85 90.7 76 81 88 94
MBh 21.1 21.5 22.5 24.0 20.6 21.0 22.0 23.5 20.1 20.5 21.5 22.9 19.6 20.0 20.9 22.3 18.6 19.0 19.9 21.2 17.3 17.6 18.4 19.7
S/T 0.87 0.84 0.76 0.61 0.90 0.87 0.78 0.64 0.92 0.89 0.80 0.65 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.96 0.87 0.71
∆T 24 24 22 19 24 24 23 20 24 24 23 20 25 24 23 20 24 24 23 19 23 22 21 18
kW 1.52 1.56 1.62 1.68 1.66 1.70 1.76 1.82 1.78 1.82 1.89 1.96 1.88 1.93 2.00 2.07 1.97 2.02 2.09 2.17 2.05 2.10 2.17 2.26
Amps 7.1 7.3 7.5 7.7 7.6 7.8 8.0 8.2 8.2 8.3 8.6 8.8 8.6 8.8 9.1 9.4 9.1 9.3 9.6 9.9 9.6 9.8 10.1 10.4
HI PR 138 149 157 164 155 167 176 184 176 190 200 209 201 216 228 238 226 243 257 268 250 269 284 296
LO PR 59 63 68 73 62 66 72 77 65 69 75 80 68 72 79 84 71 76 83 88 74 78 85 91
MBh 22.8 23.3 24.4 26.0 22.3 22.7 23.8 25.4 21.8 22.2 23.3 24.8 21.2 21.7 22.7 24.2 20.2 20.6 21.6 23.0 18.7 19.1 20.0 21.3
S/T 0.90 0.87 0.79 0.64 0.93 0.90 0.81 0.66 0.96 0.92 0.83 0.68 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.73 1.00 1.00 0.90 0.73
24 24 22 19 24 24 22 19 23 23 22 19 21 22 21 18
∆T 24 23 22 19 24 24 22 19
kW 1.57 1.60 1.66 1.72 1.70 1.75 1.81 1.88 1.83 1.87 1.94 2.01 1.93 1.98 2.05 2.13 2.03 2.08 2.15 2.23 2.10 2.16 2.24 2.32
7.3 7.5 7.7 7.9 7.8 8.0 8.2 8.4 8.4 8.5 8.8 9.1 8.9 9.0 9.3 9.6 9.3 9.5 9.8 10.1 9.8 10.0 10.3 10.7
Amps
HI PR 142 153 162 169 160 172 182 189 182 196 207 216 207 223 235 245 233 251 265 276 257 277 293 305
LO PR 61 65 70 75 64 68 74 79 67 71 77 82 70 74 81 87 73 78 85 91 76 81 88 94
MBh 23.5 24.0 25.1 26.8 23.0 23.4 24.5 26.2 22.4 22.9 24.0 25.6 21.9 22.3 23.4 24.9 20.8 21.2 22.2 23.7 19.3 19.6 20.6 21.9
S/T 0.95 0.91 0.82 0.67 0.98 0.95 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.94 0.77
∆T 23 22 21 18 23 23 21 19 23 23 21 19 22 23 22 19 21 22 21 18 20 20 20 17
kW 1.58 1.62 1.68 1.74 1.72 1.76 1.83 1.89 1.84 1.89 1.96 2.03 1.95 2.00 2.07 2.15 2.04 2.10 2.17 2.25 2.12 2.18 2.26 2.34
Amps 7.4 7.5 7.7 8.0 7.9 8.0 8.2 8.5 8.4 8.6 8.9 9.1 8.9 9.1 9.4 9.7 9.4 9.6 9.9 10.2 9.9 10.1 10.4 10.8
HI PR 144 155 164 171 161 174 183 191 184 198 209 218 209 225 238 248 235 253 267 279 260 280 295 308
LO PR 61 65 71 76 65 69 75 80 67 72 78 83 71 75 82 87 74 79 86 92 77 82 89 95
800
85
900
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
700
800
80
900
700
SS-GSC13 www.goodmanmfg.com 7
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
P
roduct SPecificationS
expAnded rAtinGS — GSC130301**
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 26.1 27.0 29.6 - 24.8 25.7 28.1 - 22.9 23.8 26.1 -
21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
∆T 21 19 16 11 21 20 16 11
kW 1.96 2.00 2.06 2.12 2.10 2.14 2.21 2.28 2.23 2.27 2.35 2.42 2.34 2.39 2.46 2.54 2.43 2.49 2.57 2.65 2.52 2.57 2.65 2.74
7.2 7.4 7.6 7.9 7.8 7.9 8.2 8.5 8.4 8.6 8.8 9.2 8.9 9.1 9.4 9.8 9.5 9.7 10.0 10.3 10.0 10.2 10.6 10.9
Amps
HI PR 153 165 174 182 172 185 195 204 195 210 222 232 223 240 253 264 250 269 285 297 277 298 314 328
LO PR 60 64 70 74 64 68 74 79 66 70 77 82 69 74 81 86 73 77 84 90 75 80 87 93
MBh 28.5 29.3 31.8 34.1 27.8 28.7 31.0 33.3 27.2 28.0 30.3 32.5 26.5 27.3 29.5 31.7 25.2 25.9 28.1 30.1 23.3 24.0 26.0 27.9
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.78 0.59 0.38 0.91 0.81 0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
∆T 20 19 15 11 20 19 15 11 21 19 15 11 21 19 16 11 20 19 15 11 19 18 14 10
kW 1.97 2.01 2.07 2.14 2.12 2.16 2.23 2.30 2.24 2.29 2.36 2.44 2.36 2.41 2.48 2.57 2.45 2.51 2.59 2.67 2.54 2.59 2.68 2.76
Amps 7.3 7.5 7.7 7.9 7.8 8.0 8.3 8.5 8.5 8.7 8.9 9.2 9.0 9.2 9.5 9.8 9.5 9.8 10.1 10.4 10.1 10.3 10.6 11.0
HI PR 155 166 176 183 174 187 197 206 197 212 224 234 225 242 255 266 253 272 287 300 279 301 318 331
LO PR 61 65 71 75 64 68 75 79 67 71 77 83 70 75 81 87 73 78 85 91 76 81 88 94
7.2 7.4 7.6 - 7.8 7.9 8.2 - 8.4 8.6 8.8 - 8.9 9.1 9.4 - 9.5 9.7 10.0 - 10.0 10.2 10.5 -
∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
S/T 0.67 0.56 0.39 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.64 0.44 - 0.77 0.64 0.44 -
MBh 25.1 26.0 28.5 - 24.5 25.4 27.9 - 23.9 24.8 27.2 - 23.4 24.2 26.5 - 22.2 23.0 25.2 - 20.6 21.3 23.3 -
kW 1.90 1.94 1.99 - 2.04 2.08 2.14 - 2.16 2.20 2.27 - 2.27 2.31 2.39 - 2.36 2.41 2.48 - 2.44 2.49 2.57 -
HI PR 147 158 167 - 165 178 188 - 188 202 213 - 214 230 243 - 240 259 273 - 266 286 302 -
Amps 7.0 7.1 7.4 - 7.5 7.7 7.9 - 8.1 8.3 8.5 - 8.6 8.8 9.1 - 9.1 9.3 9.6 - 9.6 9.9 10.2 -
LO PR 58 61 67 - 61 65 71 - 63 67 74 - 67 71 77 - 70 74 81 - 72 77 84 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
MBh 27.2 28.2 30.9 - 26.6 27.5 30.2 - 25.9 26.9 29.5 - 25.3 26.2 28.7 - 24.0 24.9 27.3 - 22.3 23.1 25.3 -
kW 1.94 1.98 2.04 - 2.08 2.13 2.19 - 2.21 2.26 2.33 - 2.32 2.37 2.44 - 2.41 2.47 2.55 - 2.50 2.55 2.63 -
HI PR 152 163 172 - 170 183 193 - 193 208 220 - 220 237 250 - 248 267 282 - 274 295 311 -
Amps 7.2 7.3 7.6 - 7.7 7.9 8.1 - 8.3 8.5 8.8 - 8.9 9.1 9.3 - 9.4 9.6 9.9 - 9.9 10.1 10.5 -
LO PR 60 63 69 - 63 67 73 - 65 70 76 - 69 73 80 - 72 77 84 - 74 79 86 -
MBh 28.0 29.0 31.8 - 27.4 28.4 31.1 - 26.7 27.7 30.3
∆T 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.44 - 0.77 0.64 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
kW 1.96 2.00 2.06 - 2.10 2.14 2.21 - 2.23 2.27 2.34 - 2.34 2.39 2.46 - 2.43 2.49 2.57 - 2.52 2.57 2.65 -
HI PR 153 165 174 - 172 185 195 - 195 210 222 - 223 239 253 - 250 269 285 - 277 298 314 -
Amps
LO PR 60 64 70 - 64 68 74 - 66 70 77 - 69 74 81 - 73 77 84 - 75 80 87 -
MBh 25.5 26.3 28.5 30.5 24.9 25.7 27.8 29.8 24.4 25.1 27.1 29.1 23.8 24.5 26.5 28.4 22.6 23.2 25.2 27.0 20.9 21.5 23.3 25.0
S/T 0.76 0.68 0.51 0.33 0.79 0.70 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.59 0.38 0.87 0.78 0.59 0.38
∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 17 11 22 20 16 11 20 19 15 10
kW 1.91 1.95 2.01 2.07 2.05 2.09 2.16 2.23 2.17 2.22 2.29 2.36 2.28 2.33 2.41 2.48 2.38 2.43 2.50 2.58 2.46 2.51 2.59 2.67
Amps 7.1 7.2 7.4 7.7 7.6 7.7 8.0 8.3 8.2 8.4 8.6 8.9 8.7 8.9 9.2 9.5 9.2 9.4 9.7 10.1 9.7 10.0 10.3 10.6
HI PR 149 160 169 176 167 179 189 198 190 204 215 225 216 232 245 256 243 261 276 288 268 289 305 318
LO PR 58 62 68 72 62 66 72 76 64 68 74 79 67 72 78 83 71 75 82 87 73 78 85 90
MBh 27.7 28.5 30.8 33.1 27.0 27.8 30.1 32.3 26.4 27.2 29.4 31.6 25.7 26.5 28.7 30.8 24.5 25.2 27.3 29.2 22.7 23.3 25.2 27.1
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
950
75
1069
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
831
950
70
1069
831
8 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
expAnded rAtinGS — GSC130301** (Cont.)
P
roduct SPecificationS
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
MBh 26.0 26.6 28.4 30.3 25.4 25.9 27.7 29.6 24.8 25.3 27.1 28.9 24.2 24.7 26.4 28.2 23.0 23.5 25.1 26.8 21.3 21.7 23.2 24.8
S/T 0.83 0.78 0.64 0.5 0.86 0.81 0.66 0.49 0.88 0.83 0.68 0.5 0.91 0.86 0.70 0.52 0.95 0.89 0.72 0.5 0.96 0.90 0.73 0.55
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 22 19 15
kW 1.93 1.97 2.02 2.1 2.07 2.11 2.17 2.24 2.19 2.24 2.31 2.4 2.30 2.35 2.42 2.50 2.39 2.45 2.52 2.6 2.48 2.53 2.61 2.70
Amps 7.1 7.3 7.5 7.7 7.6 7.8 8.0 8.3 8.2 8.4 8.7 9.0 8.8 9.0 9.3 9.6 9.3 9.5 9.8 10.2 9.8 10.0 10.4 10.7
HI PR 150 161 171 177.8 168 181 191 200 191 206 218 227.0 218 235 248 258 245 264 279 290.8 271 292 308 321
LO PR 59 63 68 72.9 62 66 72 77 65 69 75 80.1 68 72 79 84 71 76 83 88.1 74 78 86 91
MBh 28.2 28.8 30.7 32.9 27.5 28.1 30.0 32.1 26.9 27.4 29.3 31.3 26.2 26.8 28.6 30.6 24.9 25.4 27.2 29.0 23.1 23.6 25.2 26.9
S/T 0.86 0.81 0.66 0.5 0.89 0.84 0.68 0.51 0.92 0.86 0.70 0.5 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.6 0.99 0.93 0.76 0.57
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 18 15
kW 1.97 2.01 2.07 2.1 2.12 2.16 2.23 2.30 2.25 2.29 2.36 2.4 2.36 2.41 2.49 2.57 2.45 2.51 2.59 2.7 2.54 2.59 2.68 2.76
Amps 7.3 7.5 7.7 7.9 7.8 8.0 8.3 8.5 8.5 8.7 8.9 9.2 9.0 9.2 9.5 9.8 9.5 9.8 10.1 10.4 10.1 10.3 10.6 11.0
HI PR 155 166 176 183.3 174 187 197 206 197 212 224 234.0 225 242 256 266 253 272 287 299.8 279 301 318 331
LO PR 61 65 71 75.2 64 68 75 79 67 71 77 82.5 70 75 81 87 73 78 85 90.9 76 81 88 94
32.3 27.0 27.6 29.5 31.5 25.6 26.2 28.0 29.9 23.7 24.3 25.9 27.7
MBh 29.0 29.6 31.7 33.9 28.3 29.0 30.9 33.1 27.7 28.3 30.2
S/T 0.91 0.85 0.69 0.5 0.94 0.88 0.72 0.54 0.96 0.90 0.73 0.5 1.00 0.93 0.76 0.57 1.00 0.97 0.79 0.6 1.00 1.00 0.79 0.59
∆T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 22 22 19 15 20 21 18 14
kW 1.99 2.03 2.09 2.2 2.13 2.18 2.24 2.32 2.26 2.31 2.38 2.5 2.38 2.43 2.51 2.59 2.47 2.53 2.61 2.7 2.56 2.61 2.70 2.79
7.4 7.5 7.7 8.0 7.9 8.1 8.3 8.6 8.5 8.7 9.0 9.3 9.1 9.3 9.6 9.9 9.6 9.9 10.2 10.5 10.2 10.4 10.7 11.1
Amps
HI PR 156 168 178 185.2 175 189 199 208 199 215 227 236.3 227 244 258 269 255 275 290 302.8 282 304 321 335
LO PR 61 65 71 75.9 65 69 75 80 67 72 78 83.4 71 75 82 88 74 79 86 91.8 77 82 89 95
MBh 26.4 27.0 28.2 30.1 25.8 26.3 27.6 29.4 25.2 25.7 26.9 28.7 24.6 25.1 26.3 28.0 23.4 23.8 25.0 26.6 21.7 22.1 23.1 24.7
S/T 0.87 0.84 0.76 0.62 0.90 0.87 0.79 0.64 0.93 0.90 0.81 0.66 0.96 0.92 0.83 0.68 0.99 0.96 0.87 0.70 1.00 0.97 0.87 0.71
∆T 26 25 24 21 26 25 24 21 26 25 24 21 26 26 24 21 26 25 24 21 24 24 22 19
kW 1.94 1.98 2.04 2.10 2.08 2.13 2.19 2.26 2.21 2.26 2.33 2.40 2.32 2.37 2.44 2.52 2.41 2.47 2.54 2.63 2.50 2.55 2.63 2.72
Amps 7.2 7.3 7.5 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.8 9.1 8.8 9.1 9.3 9.7 9.4 9.6 9.9 10.3 9.9 10.1 10.5 10.8
HI PR 152 163 172 180 170 183 193 202 193 208 220 229 220 237 250 261 248 267 282 294 274 295 311 325
LO PR 60 63 69 74 63 67 73 78 65 70 76 81 69 73 80 85 72 77 84 89 74 79 86 92
MBh 28.7 29.2 30.6 32.6 28.0 28.5 29.9 31.9 27.3 27.9 29.2 31.1 26.7 27.2 28.5 30.4 25.3 25.8 27.0 28.8 23.5 23.9 25.0 26.7
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.90 0.73
25 25 24 20 26 25 24 21 25 25 23 20 23 23 22 19
∆T 25 25 23 20 25 25 24 20
kW 1.99 2.03 2.09 2.15 2.13 2.18 2.24 2.32 2.26 2.31 2.38 2.46 2.38 2.43 2.51 2.59 2.47 2.53 2.61 2.69 2.56 2.61 2.70 2.79
7.4 7.5 7.7 8.0 7.9 8.1 8.3 8.6 8.5 8.7 9.0 9.3 9.1 9.3 9.6 9.9 9.6 9.9 10.2 10.5 10.2 10.4 10.7 11.1
Amps
HI PR 156 168 178 185 175 189 199 208 199 215 227 236 227 244 258 269 255 275 290 303 282 304 321 335
LO PR 61 65 71 76 65 69 75 80 67 72 78 83 71 75 82 88 74 79 86 92 77 82 89 95
MBh 29.5 30.1 31.5 33.6 28.8 29.4 30.8 32.8 28.1 28.7 30.0 32.1 27.5 28.0 29.3 31.3 26.1 26.6 27.8 29.7 24.2 24.6 25.8 27.5
S/T 0.95 0.92 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
∆T 24 24 22 19 24 24 23 20 24 24 23 20 24 24 23 20 22 23 23 20 21 21 21 18
kW 2.00 2.04 2.10 2.17 2.15 2.19 2.26 2.33 2.28 2.33 2.40 2.48 2.40 2.45 2.53 2.61 2.49 2.55 2.63 2.72 2.58 2.64 2.72 2.81
Amps 7.4 7.6 7.8 8.1 8.0 8.1 8.4 8.7 8.6 8.8 9.1 9.4 9.2 9.4 9.7 10.0 9.7 9.9 10.3 10.6 10.3 10.5 10.8 11.2
HI PR 158 170 179 187 177 191 201 210 201 217 229 239 229 247 261 272 258 278 293 306 285 307 324 338
LO PR 62 66 72 77 65 70 76 81 68 72 79 84 71 76 83 88 75 80 87 93 77 82 90 96
950
85
1069
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
831
950
80
1069
831
SS-GSC13 www.goodmanmfg.com 9
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
P
roduct SPecificationS
expAnded CoolinG dAtA — GSC130361G*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 31.2 32.3 35.4 - 29.6 30.7 33.6 - 27.4 28.4 31.2 -
22 20 17 12 22 21 17 12 22 20 17 11 21 19 16 11
9.1 9.3 9.6 - 9.8 10.1 10.4 - 10.6 10.9 11.2 - 11.3 11.6 12.0 - 12.1 12.3 12.7 - 12.7 13.1 13.5 -
9.1 9.3 9.6 10.0 9.8 10.1 10.4 10.7 10.6 10.9 11.2 11.6 11.3 11.6 12.0 12.4 12.1 12.3 12.7 13.2 12.7 13.1 13.5 14.0
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
∆T 19 17 13 - 19 17 13 - 20 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
S/T 0.67 0.56 0.39 - 0.70 0.58 0.40 - 0.71 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.77 0.64 0.45 -
MBh 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.7 32.5 - 27.9 29.0 31.7 - 26.5 27.5 30.1 - 24.6 25.5 27.9 -
kW 2.31 2.36 2.43 - 2.48 2.53 2.61 - 2.63 2.68 2.77 - 2.76 2.82 2.91 - 2.87 2.93 3.03 - 2.97 3.03 3.13 -
963
HI PR 141 152 160 - 158 170 180 - 180 194 205 - 205 221 233 - 231 248 262 - 255 274 290 -
Amps 8.8 9.0 9.3 - 9.5 9.7 10.0 - 10.3 10.5 10.8 - 10.9 11.2 11.6 - 11.6 11.9 12.3 - 12.3 12.6 13.0 -
LO PR 59 62 68 - 62 66 72 - 64 69 75 - 68 72 79 - 71 75 82 - 73 78 85 -
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 13 - 18 15 12 -
S/T 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.80 0.67 0.46 -
MBh 32.5 33.7 36.9 - 31.8 32.9 36.1 - 31.0 32.2 35.2 - 30.3 31.4 34.4 - 28.8 29.8 32.7 - 26.6 27.6 30.2 -
kW 2.37 2.42 2.49 - 2.54 2.59 2.67 - 2.69 2.75 2.84 - 2.83 2.89 2.98 - 2.94 3.01 3.10 - 3.04 3.11 3.21 -
1100
70
HI PR 146 157 165 - 163 176 186 - 186 200 211 - 212 228 240 - 238 256 270 - 263 283 299 -
Amps 9.0 9.2 9.5 - 9.7 10.0 10.3 - 10.5 10.8 11.1 - 11.2 11.5 11.9 - 11.9 12.2 12.6 - 12.6 12.9 13.4 -
LO PR 60 64 70 - 64 68 74 - 66 71 77 - 70 74 81 - 73 78 85 - 76 80 88 -
MBh 33.5 34.7 38.1 - 32.7 33.9 37.2 - 32.0 33.1 36.3
∆T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
S/T 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.84 0.70 0.49 -
kW 2.39 2.43 2.51 - 2.56 2.61 2.69 - 2.71 2.77 2.86 - 2.85 2.91 3.00 - 2.97 3.03 3.13 - 3.07 3.13 3.23 -
HI PR 147 158 167 - 165 178 187 - 188 202 213 - 214 230 243 - 240 259 273 - 266 286 302 -
Amps
LO PR 61 65 71 - 65 69 75 - 67 71 78 - 70 75 82 - 74 79 86 - 76 81 89 -
1238
MBh 30.5 31.4 34.0 36.5 29.8 30.7 33.2 35.7 29.1 30.0 32.5 34.8 28.4 29.3 31.7 34.0 27.0 27.8 30.1 32.3 25.0 25.7 27.9 29.9
S/T 0.76 0.68 0.52 0.33 0.79 0.71 0.54 0.34 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.36 0.87 0.78 0.59 0.38 0.88 0.78 0.59 0.38
∆T 22 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11
kW 2.33 2.38 2.45 2.52 2.50 2.55 2.63 2.71 2.65 2.71 2.79 2.88 2.78 2.84 2.93 3.03 2.90 2.96 3.05 3.15 2.99 3.06 3.16 3.26
963
Amps 8.9 9.1 9.4 9.7 9.6 9.8 10.1 10.5 10.4 10.6 10.9 11.3 11.0 11.3 11.7 12.1 11.7 12.0 12.4 12.9 12.4 12.7 13.1 13.6
HI PR 143 153 162 169 160 172 182 190 182 196 207 216 207 223 236 246 233 251 265 276 258 277 293 305
LO PR 59 63 69 73 63 67 73 77 65 69 76 81 68 73 79 85 72 76 83 89 74 79 86 92
MBh 33.1 34.1 36.9 39.6 32.3 33.3 36.0 38.7 31.5 32.5 35.2 37.7 30.8 31.7 34.3 36.8 29.2 30.1 32.6 35.0 27.1 27.9 30.2 32.4
S/T 0.79 0.71 0.54 0.34 0.82 0.73 0.56 0.36 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.81 0.62 0.40
∆T 22 20 17 11 22 20 17 12
kW 2.39 2.43 2.51 2.58 2.56 2.61 2.69 2.78 2.72 2.77 2.86 2.95 2.85 2.91 3.00 3.10 2.97 3.03 3.13 3.23 3.07 3.13 3.24 3.34
1100
75
HI PR 147 158 167 174 165 178 187 196 188 202 213 222 214 230 243 253 240 259 273 285 266 286 302 315
Amps
LO PR 61 65 71 76 65 69 75 80 67 71 78 83 70 75 82 87 74 79 86 91 76 81 89 95
MBh 34.1 35.1 38.0 40.8 33.3 34.3 37.1 39.8 32.5 33.5 36.2 38.9 31.7 32.6 35.3 37.9 30.1 31.0 33.6 36.0 27.9 28.7 31.1 33.4
S/T 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.62 0.40 0.95 0.85 0.64 0.41 0.95 0.85 0.65 0.42
∆T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10
kW 2.40 2.45 2.53 2.60 2.58 2.63 2.72 2.80 2.74 2.79 2.88 2.97 2.87 2.94 3.03 3.13 2.99 3.06 3.15 3.26 3.09 3.16 3.26 3.37
1238
Amps 9.2 9.4 9.7 10.0 9.9 10.1 10.5 10.8 10.7 11.0 11.3 11.8 11.4 11.7 12.1 12.5 12.2 12.5 12.9 13.3 12.9 13.2 13.6 14.1
HI PR 148 160 169 176 167 179 189 197 190 204 215 225 216 232 245 256 243 261 276 288 268 289 305 318
LO PR 62 66 72 76 65 69 76 81 68 72 79 84 71 76 83 88 75 79 87 92 77 82 90 95
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
10 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
expAnded CoolinG dAtA — GSC130361G* (Cont.)
P
roduct SPecificationS
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
MBh 31.1 31.8 33.9 36.3 30.4 31.0 33.1 35.4 29.6 30.3 32.4 34.6 28.9 29.5 31.6 33.7 27.5 28.1 30.0 32.1 25.4 26.0 27.8 29.7
S/T 0.84 0.79 0.64 0.5 0.87 0.81 0.66 0.50 0.89 0.83 0.68 0.5 0.92 0.86 0.70 0.52 0.95 0.89 0.73 0.5 0.96 0.90 0.73 0.55
∆T 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 23 22 19 16
kW 2.35 2.40 2.47 2.5 2.52 2.57 2.65 2.73 2.67 2.73 2.81 2.9 2.81 2.87 2.96 3.05 2.92 2.98 3.08 3.2 3.02 3.08 3.18 3.29
Amps 9.0 9.2 9.5 9.8 9.7 9.9 10.2 10.6 10.5 10.7 11.0 11.4 11.1 11.4 11.8 12.2 11.8 12.1 12.5 13.0 12.5 12.8 13.2 13.7
HI PR 144 155 164 170.7 162 174 184 192 184 198 209 217.9 209 225 238 248 236 253 268 279.2 260 280 296 308
LO PR 60 64 70 74.1 63 67 73 78 66 70 76 81.3 69 73 80 85 72 77 84 89.5 75 80 87 93
MBh 33.7 34.4 36.8 39.3 32.9 33.6 35.9 38.4 32.1 32.8 35.1 37.5 31.3 32.0 34.2 36.6 29.8 30.4 32.5 34.7 27.6 28.2 30.1 32.2
S/T 0.87 0.81 0.66 0.5 0.90 0.84 0.69 0.51 0.92 0.87 0.70 0.5 0.95 0.89 0.73 0.54 0.99 0.93 0.75 0.6 1.00 0.93 0.76 0.57
∆T 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 25 24 20 16 23 22 19 15
kW 2.40 2.45 2.53 2.6 2.58 2.63 2.72 2.80 2.74 2.79 2.88 3.0 2.87 2.94 3.03 3.13 2.99 3.06 3.15 3.3 3.09 3.16 3.26 3.37
Amps 9.2 9.4 9.7 10.1 9.9 10.1 10.5 10.8 10.7 11.0 11.3 11.8 11.4 11.7 12.1 12.5 12.2 12.5 12.9 13.3 12.9 13.2 13.6 14.1
HI PR 149 160 169 176.0 167 179 189 198 190 204 215 224.6 216 232 245 256 243 261 276 287.8 268 289 305 318
LO PR 62 66 72 76.4 65 69 76 81 68 72 79 83.8 71 76 83 88 75 79 87 92.3 77 82 90 95
38.6 32.3 33.0 35.2 37.7 30.7 31.3 33.5 35.8 28.4 29.0 31.0 33.1
MBh 34.7 35.4 37.9 40.5 33.9 34.6 37.0 39.5 33.1 33.8 36.1
S/T 0.91 0.85 0.69 0.5 0.94 0.88 0.72 0.54 0.97 0.91 0.74 0.6 1.00 0.94 0.76 0.57 1.00 1.00 0.79 0.6 1.00 1.00 0.80 0.60
∆T 23 22 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 21 22 18 15
kW 2.42 2.47 2.55 2.6 2.60 2.65 2.74 2.82 2.76 2.82 2.90 3.0 2.90 2.96 3.05 3.15 3.02 3.08 3.18 3.3 3.12 3.19 3.29 3.40
9.3 9.5 9.8 10.1 10.0 10.2 10.6 10.9 10.8 11.1 11.4 11.9 11.6 11.8 12.2 12.7 12.3 12.6 13.0 13.5 13.0 13.3 13.7 14.2
Amps
HI PR 150 161 170 177.8 168 181 191 199 191 206 218 226.9 218 235 248 258 245 264 279 290.7 271 292 308 321
LO PR 62 66 72 77.1 66 70 77 81 68 73 80 84.7 72 77 84 89 75 80 88 93.2 78 83 91 96
MBh 31.6 32.2 33.8 36.0 30.9 31.5 33.0 35.2 30.2 30.7 32.2 34.3 29.4 30.0 31.4 33.5 27.9 28.5 29.8 31.8 25.9 26.4 27.6 29.5
S/T 0.88 0.85 0.76 0.62 0.91 0.88 0.79 0.64 0.93 0.90 0.81 0.66 0.96 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 0.97 0.88 0.71
∆T 27 26 25 21 27 26 25 22 27 26 25 22 27 27 25 22 27 26 25 21 25 25 23 20
kW 2.37 2.41 2.49 2.56 2.54 2.59 2.67 2.76 2.69 2.75 2.84 2.93 2.83 2.89 2.98 3.08 2.94 3.01 3.10 3.20 3.04 3.11 3.21 3.31
Amps 9.0 9.2 9.5 9.9 9.7 10.0 10.3 10.6 10.5 10.8 11.1 11.5 11.2 11.5 11.9 12.3 11.9 12.2 12.6 13.1 12.6 12.9 13.4 13.9
HI PR 145 157 165 172 163 176 186 194 186 200 211 220 211 228 240 251 238 256 270 282 263 283 299 312
LO PR 60 64 70 75 64 68 74 79 66 71 77 82 70 74 81 86 73 78 85 90 76 80 88 94
MBh 34.3 34.9 36.6 39.0 33.5 34.1 35.7 38.1 32.7 33.3 34.9 37.2 31.9 32.5 34.0 36.3 30.3 30.9 32.3 34.5 28.0 28.6 29.9 31.9
S/T 0.91 0.88 0.79 0.64 0.94 0.91 0.82 0.67 0.97 0.93 0.84 0.68 1.00 0.96 0.87 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.91 0.74
26 26 25 21 27 26 25 21 25 26 24 21 23 24 23 20
∆T 26 26 24 21 26 26 25 21
kW 2.42 2.47 2.55 2.62 2.60 2.65 2.74 2.82 2.76 2.82 2.90 3.00 2.90 2.96 3.05 3.15 3.02 3.08 3.18 3.28 3.12 3.19 3.29 3.40
9.3 9.5 9.8 10.1 10.0 10.2 10.6 10.9 10.8 11.1 11.4 11.9 11.6 11.8 12.2 12.7 12.3 12.6 13.0 13.5 13.0 13.3 13.7 14.2
Amps
HI PR 150 161 170 178 168 181 191 199 191 206 218 227 218 235 248 258 245 264 279 291 271 292 308 321
LO PR 62 66 72 77 66 70 77 81 68 73 80 85 72 77 84 89 75 80 88 93 78 83 91 96
MBh 35.3 36.0 37.7 40.2 34.5 35.1 36.8 39.3 33.7 34.3 35.9 38.3 32.8 33.5 35.0 37.4 31.2 31.8 33.3 35.5 28.9 29.5 30.8 32.9
S/T 0.95 0.92 0.83 0.67 0.99 0.95 0.86 0.70 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.95 0.77 1.00 1.00 0.95 0.77
∆T 25 25 23 20 25 25 24 20 25 25 24 20 24 25 24 21 23 24 23 20 21 22 22 19
kW 2.44 2.49 2.57 2.65 2.62 2.68 2.76 2.85 2.78 2.84 2.93 3.02 2.92 2.98 3.08 3.18 3.04 3.11 3.21 3.31 3.14 3.21 3.32 3.43
Amps 9.4 9.6 9.9 10.2 10.1 10.3 10.6 11.0 10.9 11.2 11.5 12.0 11.7 11.9 12.3 12.8 12.4 12.7 13.1 13.6 13.1 13.4 13.9 14.4
HI PR 151 163 172 180 170 183 193 201 193 208 220 229 220 237 250 261 248 267 282 294 274 295 311 324
LO PR 63 67 73 78 67 71 77 82 69 74 80 86 73 77 84 90 76 81 88 94 79 84 91 97
963
1100
85
1238
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
963
1100
80
1238
SS-GSC13 www.goodmanmfg.com 11
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
P
roduct SPecificationS
expAnded rAtinGS — GSC130421C*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 36.9 38.3 42.0 - 35.1 36.4 39.9 - 32.5 33.7 36.9 -
21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10
∆T 21 19 16 11 21 20 16 11
kW 2.20 2.26 2.34 2.43 2.40 2.46 2.55 2.65 2.58 2.64 2.74 2.85 2.73 2.80 2.91 3.02 2.86 2.94 3.05 3.16 2.98 3.05 3.17 3.29
8.3 8.5 8.8 9.1 8.9 9.1 9.4 9.7 9.6 9.9 10.2 10.5 10.3 10.5 10.8 11.2 10.9 11.1 11.5 11.9 11.5 11.7 12.1 12.5
Amps
HI PR 131 141 149 156 147 159 167 175 168 180 190 199 191 205 217 226 215 231 244 255 237 255 270 281
LO PR 62 66 72 77 66 70 76 81 68 73 79 85 72 76 83 89 75 80 87 93 78 83 90 96
MBh 40.4 41.6 45.0 48.3 39.4 40.6 44.0 47.2 38.5 39.6 42.9 46.1 37.6 38.7 41.9 44.9 35.7 36.7 39.8 42.7 33.1 34.0 36.8 39.5
S/T 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.66 0.43
∆T 20 19 15 10 20 19 15 11 20 19 15 11 21 19 15 11 20 19 15 11 19 17 14 10
kW 2.22 2.28 2.36 2.45 2.42 2.48 2.58 2.67 2.60 2.67 2.77 2.87 2.76 2.83 2.93 3.05 2.89 2.97 3.08 3.19 3.01 3.08 3.20 3.32
Amps 8.4 8.6 8.8 9.1 9.0 9.2 9.5 9.8 9.7 9.9 10.2 10.6 10.3 10.6 10.9 11.3 11.0 11.2 11.6 12.0 11.6 11.8 12.2 12.6
HI PR 133 143 151 157 149 160 169 176 169 182 192 201 193 207 219 228 217 233 246 257 240 258 272 284
LO PR 63 67 73 78 66 71 77 82 69 74 80 85 73 77 84 90 76 81 88 94 79 84 91 97
8.3 8.5 8.8 - 8.9 9.1 9.4 - 9.6 9.9 10.2 - 10.2 10.5 10.8 - 10.9 11.1 11.5 - 11.5 11.7 12.1 -
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.79 0.66 0.46 -
MBh 35.6 36.9 40.4 - 34.8 36.0 39.5 - 33.9 35.2 38.5 - 33.1 34.3 37.6 - 31.4 32.6 35.7 - 29.1 30.2 33.1 -
kW 2.12 2.17 2.25 - 2.31 2.37 2.46 - 2.48 2.54 2.64 - 2.63 2.70 2.80 - 2.76 2.83 2.93 - 2.87 2.94 3.05 -
HI PR 126 136 143 - 141 152 161 - 161 173 183 - 183 197 208 - 206 222 234 - 228 245 259 -
Amps 8.1 8.2 8.5 - 8.6 8.8 9.1 - 9.3 9.5 9.8 - 9.9 10.1 10.4 - 10.5 10.7 11.1 - 11.1 11.3 11.7 -
LO PR 60 64 69 - 63 67 73 - 66 70 76 - 69 73 80 - 72 77 84 - 75 80 87 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
S/T 0.72 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.78 0.66 0.45 - 0.81 0.68 0.47 - 0.82 0.69 0.48 -
MBh 38.6 40.0 43.8 - 37.7 39.0 42.8 - 36.8 38.1 41.7 - 35.9 37.2 40.7 - 34.1 35.3 38.7 - 31.6 32.7 35.8 -
kW 2.18 2.23 2.32 - 2.38 2.44 2.53 - 2.55 2.62 2.71 - 2.71 2.78 2.88 - 2.84 2.91 3.02 - 2.95 3.03 3.14 -
HI PR 130 140 148 - 146 157 166 - 166 179 189 - 189 203 215 - 213 229 242 - 235 253 267 -
Amps 8.3 8.4 8.7 - 8.9 9.1 9.3 - 9.6 9.8 10.1 - 10.2 10.4 10.7 - 10.8 11.0 11.4 - 11.4 11.6 12.0 -
LO PR 62 66 72 - 65 69 76 - 68 72 79 - 71 76 83 - 75 79 87 - 77 82 90 -
MBh 39.7 41.2 45.1 - 38.8 40.2 44.0 - 37.9 39.2 43.0
∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 11 - 16 14 11 -
S/T 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.82 0.69 0.48 - 0.85 0.71 0.49 - 0.86 0.72 0.50 -
kW 2.20 2.26 2.34 - 2.40 2.46 2.55 - 2.58 2.64 2.74 - 2.73 2.80 2.91 - 2.86 2.94 3.05 - 2.98 3.05 3.17 -
HI PR 131 141 149 - 147 159 167 - 168 180 190 - 191 205 217 - 215 231 244 - 237 255 270 -
Amps
LO PR 62 66 72 - 66 70 76 - 68 73 79 - 72 76 83 - 75 80 87 - 78 83 90 -
MBh 36.2 37.3 40.3 43.3 35.3 36.4 39.4 42.3 34.5 35.5 38.5 41.3 33.7 34.7 37.5 40.3 32.0 32.9 35.6 38.3 29.6 30.5 33.0 35.4
S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.81 0.61 0.39
∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 2.14 2.19 2.27 2.36 2.33 2.39 2.48 2.57 2.50 2.57 2.66 2.76 2.65 2.72 2.82 2.93 2.78 2.85 2.96 3.07 2.89 2.97 3.08 3.20
Amps 8.1 8.3 8.5 8.8 8.7 8.9 9.2 9.5 9.4 9.6 9.9 10.2 10.0 10.2 10.5 10.9 10.6 10.8 11.2 11.6 11.2 11.4 11.8 12.2
HI PR 127 137 145 151 143 154 162 169 163 175 185 193 185 199 210 219 208 224 237 247 230 248 262 273
LO PR 60 64 70 75 64 68 74 79 66 71 77 82 70 74 81 86 73 78 85 90 76 80 88 93
MBh 39.2 40.4 43.7 46.9 38.3 39.4 42.7 45.8 37.4 38.5 41.7 44.7 36.5 37.6 40.6 43.6 34.6 35.7 38.6 41.4 32.1 33.0 35.8 38.4
S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.59 0.38 0.89 0.80 0.60 0.39 0.93 0.83 0.63 0.40 0.93 0.84 0.63 0.41
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
1225
1400
70
1575
1225
1400
75
1575
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
12 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
expAnded rAtinGS — GSC130421C* (Cont.)
P
roduct SPecificationS
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
MBh 36.8 37.6 40.2 43.0 36.0 36.8 39.3 42.0 35.1 35.9 38.3 41.0 34.3 35.0 37.4 40.0 32.6 33.3 35.5 38.0 30.2 30.8 32.9 35.2
S/T 0.86 0.81 0.66 0.5 0.89 0.84 0.68 0.51 0.91 0.86 0.70 0.5 0.94 0.88 0.72 0.54 0.98 0.92 0.75 0.6 0.99 0.93 0.75 0.56
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15
kW 2.16 2.21 2.30 2.4 2.36 2.41 2.50 2.60 2.53 2.59 2.69 2.8 2.68 2.75 2.85 2.96 2.81 2.88 2.99 3.1 2.92 3.00 3.11 3.23
Amps 8.2 8.4 8.6 8.9 8.8 9.0 9.3 9.6 9.5 9.7 10.0 10.3 10.1 10.3 10.6 11.0 10.7 10.9 11.3 11.7 11.3 11.5 11.9 12.3
HI PR 129 138 146 152.5 144 155 164 171 164 177 187 194.6 187 201 213 222 210 226 239 249.4 232 250 264 276
LO PR 61 65 71 75.5 64 69 75 80 67 71 78 82.9 70 75 82 87 74 78 86 91.3 76 81 89 94
MBh 39.9 40.8 43.6 46.6 39.0 39.8 42.6 45.5 38.0 38.9 41.5 44.4 37.1 37.9 40.5 43.3 35.3 36.0 38.5 41.2 32.7 33.4 35.7 38.1
S/T 0.89 0.84 0.68 0.5 0.92 0.87 0.71 0.53 0.95 0.89 0.72 0.5 0.98 0.92 0.75 0.56 1.00 0.95 0.78 0.6 1.00 0.96 0.78 0.58
∆T 23 22 19 16 24 23 20 16 24 23 20 16 24 23 20 16 23 23 20 16 21 21 18 15
kW 2.22 2.28 2.36 2.5 2.42 2.48 2.58 2.67 2.60 2.67 2.77 2.9 2.76 2.83 2.94 3.05 2.89 2.97 3.08 3.2 3.01 3.08 3.20 3.32
Amps 8.4 8.6 8.8 9.1 9.0 9.2 9.5 9.8 9.7 9.9 10.2 10.6 10.3 10.6 10.9 11.3 11.0 11.2 11.6 12.0 11.6 11.8 12.2 12.6
HI PR 133 143 151 157.2 149 160 169 176 169 182 192 200.6 193 207 219 229 217 233 246 257.1 240 258 272 284
LO PR 63 67 73 77.8 66 71 77 82 69 74 80 85.5 73 77 84 90 76 81 88 94.1 79 84 91 97
45.7 38.2 39.1 41.7 44.6 36.3 37.1 39.7 42.4 33.6 34.4 36.7 39.3
MBh 41.1 42.0 44.9 48.0 40.1 41.0 43.8 46.9 39.2 40.0 42.8
S/T 0.94 0.88 0.71 0.5 0.97 0.91 0.74 0.55 1.00 0.93 0.76 0.6 1.00 0.96 0.78 0.59 1.00 1.00 0.81 0.6 1.00 1.00 0.82 0.61
∆T 22 22 19 15 23 22 19 15 23 22 19 15 22 22 19 15 21 22 19 15 20 20 18 14
kW 2.24 2.30 2.38 2.5 2.45 2.51 2.60 2.70 2.63 2.69 2.79 2.9 2.79 2.86 2.96 3.08 2.92 2.99 3.11 3.2 3.04 3.11 3.23 3.35
8.5 8.6 8.9 9.2 9.1 9.3 9.6 9.9 9.8 10.0 10.3 10.7 10.4 10.7 11.0 11.4 11.0 11.3 11.7 12.1 11.7 11.9 12.3 12.7
Amps
HI PR 134 144 152 158.8 150 162 171 178 171 184 194 202.6 195 210 221 231 219 236 249 259.7 242 260 275 287
LO PR 64 68 74 78.6 67 71 78 83 70 74 81 86.3 73 78 85 91 77 82 89 95.0 79 85 92 98
MBh 37.5 38.2 40.0 42.7 36.6 37.3 39.1 41.7 35.7 36.4 38.1 40.7 34.9 35.5 37.2 39.7 33.1 33.8 35.4 37.7 30.7 31.3 32.8 34.9
S/T 0.90 0.87 0.79 0.64 0.93 0.90 0.81 0.66 0.96 0.92 0.83 0.68 0.99 0.95 0.86 0.70 1.00 0.99 0.89 0.73 1.00 1.00 0.90 0.73
∆T 25 25 24 20 26 25 24 21 26 25 24 21 26 25 24 21 25 25 24 21 23 23 22 19
kW 2.18 2.23 2.32 2.40 2.38 2.44 2.53 2.62 2.55 2.62 2.71 2.82 2.71 2.77 2.88 2.99 2.84 2.91 3.02 3.13 2.95 3.02 3.14 3.26
Amps 8.3 8.4 8.7 9.0 8.9 9.1 9.3 9.6 9.6 9.8 10.1 10.4 10.2 10.4 10.7 11.1 10.8 11.0 11.4 11.8 11.4 11.6 12.0 12.4
HI PR 130 140 148 154 146 157 166 173 166 178 188 197 189 203 215 224 213 229 241 252 235 253 267 278
LO PR 62 66 72 76 65 69 76 81 68 72 79 84 71 76 83 88 75 79 87 92 77 82 90 95
MBh 40.6 41.4 43.3 46.2 39.7 40.4 42.3 45.2 38.7 39.5 41.3 44.1 37.8 38.5 40.3 43.0 35.9 36.6 38.3 40.9 33.2 33.9 35.5 37.9
S/T 0.94 0.90 0.81 0.66 0.97 0.94 0.84 0.68 0.99 0.96 0.87 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.93 0.75 1.00 1.00 0.94 0.76
25 25 23 20 25 25 24 20 24 24 23 20 22 22 22 19
∆T 25 25 23 20 25 25 23 20
kW 2.24 2.30 2.38 2.47 2.45 2.51 2.60 2.70 2.63 2.69 2.79 2.90 2.79 2.86 2.96 3.08 2.92 2.99 3.11 3.23 3.04 3.11 3.23 3.35
8.5 8.6 8.9 9.2 9.1 9.3 9.6 9.9 9.8 10.0 10.3 10.7 10.4 10.7 11.0 11.4 11.0 11.3 11.7 12.1 11.7 11.9 12.3 12.7
Amps
HI PR 134 144 152 159 150 162 171 178 171 184 194 203 195 210 221 231 219 236 249 260 242 260 275 287
LO PR 64 68 74 79 67 71 78 83 70 74 81 86 73 78 85 91 77 82 89 95 79 85 92 98
MBh 41.8 42.6 44.6 47.6 40.8 41.6 43.6 46.5 39.9 40.6 42.6 45.4 38.9 39.7 41.5 44.3 37.0 37.7 39.5 42.1 34.2 34.9 36.5 39.0
S/T 0.98 0.95 0.85 0.69 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.97 0.79 1.00 1.00 0.98 0.80
∆T 24 24 22 19 24 24 23 19 23 24 23 20 23 23 23 20 22 22 22 19 20 20 21 18
kW 2.26 2.32 2.41 2.50 2.47 2.53 2.63 2.73 2.65 2.72 2.82 2.93 2.81 2.88 2.99 3.11 2.95 3.02 3.14 3.26 3.07 3.14 3.26 3.39
Amps 8.5 8.7 9.0 9.3 9.2 9.4 9.6 10.0 9.9 10.1 10.4 10.8 10.5 10.8 11.1 11.5 11.1 11.4 11.8 12.2 11.8 12.0 12.4 12.9
HI PR 135 146 154 160 152 163 173 180 173 186 196 205 197 212 224 233 221 238 251 262 244 263 278 290
LO PR 64 68 75 79 68 72 79 84 70 75 82 87 74 79 86 92 78 83 90 96 80 85 93 99
1400
85
1575
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
1225
1400
80
1575
1225
SS-GSC13 www.goodmanmfg.com 13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
P
roduct SPecificationS
expAnded rAtinGS — GSC130481C*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 42.4 43.9 48.1 - 40.2 41.7 45.7 - 37.3 38.6 42.3 -
21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10
10.2 10.4 10.8 - 11.0 11.2 11.6 - 11.9 12.2 12.6 - 12.7 13.0 13.4 - 13.4 13.8 14.2 - 14.2 14.6 15.0 -
10.2 10.4 10.8 11.1 11.0 11.2 11.6 12.0 11.9 12.2 12.6 13.0 12.7 13.0 13.4 13.9 13.4 13.8 14.2 14.7 14.2 14.6 15.0 15.6
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
S/T 0.68 0.57 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.78 0.65 0.45 - 0.78 0.66 0.45 -
MBh 40.8 42.3 46.3 - 39.9 41.3 45.3 - 38.9 40.3 44.2 - 38.0 39.3 43.1 - 36.1 37.4 41.0 - 33.4 34.6 37.9 -
kW 2.46 2.52 2.62 - 2.69 2.75 2.86 - 2.88 2.96 3.07 - 3.06 3.14 3.26 - 3.21 3.29 3.41 - 3.34 3.42 3.55 -
1400
HI PR 127 136 144 - 142 153 161 - 162 174 184 - 184 198 209 - 207 223 235 - 229 246 260 -
Amps 9.9 10.1 10.4 - 10.6 10.9 11.2 - 11.5 11.7 12.1 - 12.2 12.5 12.9 - 13.0 13.3 13.7 - 13.7 14.0 14.5 -
LO PR 60 63 69 - 63 67 73 - 66 70 76 - 69 73 80 - 72 77 84 - 75 79 87 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.43 - 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.67 0.47 - 0.81 0.68 0.47 -
MBh 44.2 45.8 50.2 - 43.2 44.8 49.0 - 42.2 43.7 47.9 - 41.1 42.6 46.7 - 39.1 40.5 44.4 - 36.2 37.5 41.1 -
kW 2.53 2.60 2.69 - 2.76 2.83 2.94 - 2.97 3.04 3.16 - 3.15 3.23 3.35 - 3.30 3.39 3.52 - 3.44 3.52 3.66 -
1600
70
HI PR 131 140 148 - 146 158 166 - 167 179 189 - 190 204 216 - 213 230 243 - 236 254 268 -
Amps 10.1 10.4 10.7 - 10.9 11.1 11.5 - 11.8 12.1 12.4 - 12.6 12.9 13.3 - 13.3 13.6 14.1 - 14.1 14.4 14.9 -
LO PR 62 65 71 - 65 69 75 - 68 72 78 - 71 75 82 - 74 79 86 - 77 82 89 -
MBh 45.5 47.2 51.7 - 44.5 46.1 50.5 - 43.4 45.0 49.3
∆T 17 15 11 - 17 15 11 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.45 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.85 0.71 0.49 - 0.85 0.71 0.49 -
kW 2.56 2.62 2.72 - 2.79 2.86 2.97 - 3.00 3.07 3.19 - 3.18 3.26 3.38 - 3.34 3.42 3.55 - 3.47 3.56 3.69 -
HI PR 132 142 150 - 148 159 168 - 168 181 191 - 192 206 218 - 216 232 245 - 238 256 271 -
Amps
LO PR 62 66 72 - 66 70 76 - 68 73 79 - 72 76 83 - 75 80 87 - 78 83 90 -
1800
MBh 41.5 42.7 46.2 49.6 40.5 41.7 45.2 48.5 39.6 40.7 44.1 47.3 38.6 39.7 43.0 46.2 36.7 37.8 40.9 43.9 34.0 35.0 37.9 40.6
S/T 0.78 0.69 0.53 0.34 0.81 0.72 0.55 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.39 0.89 0.80 0.60 0.39
∆T 21 19 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 2.48 2.55 2.64 2.74 2.71 2.78 2.88 2.99 2.91 2.99 3.10 3.22 3.09 3.17 3.29 3.41 3.24 3.32 3.45 3.58 3.37 3.46 3.59 3.72
1400
Amps 10.0 10.2 10.5 10.9 10.7 11.0 11.3 11.7 11.6 11.8 12.2 12.7 12.3 12.6 13.0 13.5 13.1 13.4 13.8 14.3 13.8 14.2 14.6 15.2
HI PR 128 138 145 152 144 154 163 170 163 176 185 193 186 200 211 220 209 225 238 248 231 249 263 274
LO PR 60 64 70 75 64 68 74 79 66 70 77 82 70 74 81 86 73 78 85 90 75 80 88 93
MBh 45.0 46.3 50.1 53.8 43.9 45.2 48.9 52.5 42.9 44.1 47.8 51.3 41.8 43.1 46.6 50.0 39.7 40.9 44.3 47.5 36.8 37.9 41.0 44.0
S/T 0.81 0.72 0.55 0.35 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.37 0.88 0.79 0.60 0.38 0.92 0.82 0.62 0.40 0.93 0.83 0.63 0.40
∆T 21 19 16 11 21 19 16 11
kW 2.56 2.62 2.72 2.82 2.79 2.86 2.97 3.08 3.00 3.07 3.19 3.31 3.18 3.26 3.39 3.52 3.34 3.42 3.55 3.69 3.47 3.56 3.69 3.84
1600
75
HI PR 132 142 150 156 148 159 168 175 168 181 191 199 192 206 218 227 216 232 245 256 238 256 271 282
Amps
LO PR 62 66 72 77 66 70 76 81 68 73 79 84 72 76 83 89 75 80 87 93 78 83 90 96
MBh 46.3 47.7 51.6 55.4 45.2 46.6 50.4 54.1 44.2 45.5 49.2 52.8 43.1 44.4 48.0 51.5 40.9 42.1 45.6 48.9 37.9 39.0 42.2 45.3
S/T 0.84 0.76 0.57 0.37 0.88 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.96 0.86 0.65 0.42 0.97 0.87 0.66 0.42
∆T 20 18 15 10 20 19 15 11 20 19 15 11 20 19 15 11 20 19 15 10 19 17 14 10
kW 2.58 2.65 2.75 2.85 2.82 2.89 3.00 3.11 3.03 3.10 3.22 3.34 3.21 3.29 3.42 3.55 3.37 3.45 3.58 3.72 3.50 3.59 3.73 3.87
1800
Amps 10.3 10.5 10.9 11.2 11.1 11.3 11.7 12.1 12.0 12.3 12.7 13.1 12.8 13.1 13.5 14.0 13.6 13.9 14.3 14.9 14.3 14.7 15.2 15.7
HI PR 133 143 151 158 149 161 170 177 170 183 193 201 194 208 220 229 218 234 247 258 241 259 273 285
LO PR 63 67 73 78 66 71 77 82 69 73 80 85 72 77 84 90 76 81 88 94 78 83 91 97
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
14 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
expAnded rAtinGS — GSC130481C* (Cont.)
P
roduct SPecificationS
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
MBh 42.2 43.2 46.1 49.3 41.3 42.2 45.0 48.1 40.3 41.2 44.0 47.0 39.3 40.1 42.9 45.9 37.3 38.1 40.7 43.6 34.6 35.3 37.7 40.3
S/T 0.85 0.80 0.65 0.5 0.88 0.83 0.67 0.50 0.91 0.85 0.69 0.5 0.93 0.88 0.71 0.53 0.97 0.91 0.74 0.6 0.98 0.92 0.75 0.56
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15
kW 2.51 2.57 2.67 2.8 2.74 2.81 2.91 3.02 2.94 3.02 3.13 3.2 3.12 3.20 3.32 3.45 3.27 3.35 3.48 3.6 3.40 3.49 3.62 3.76
Amps 10.0 10.3 10.6 10.9 10.8 11.0 11.4 11.8 11.7 12.0 12.3 12.8 12.4 12.7 13.1 13.6 13.2 13.5 14.0 14.5 14.0 14.3 14.8 15.3
HI PR 129 139 147 153.1 145 156 165 172 165 177 187 195.4 188 202 213 223 211 227 240 250.4 233 251 265 277
LO PR 61 65 71 75.3 64 68 75 80 67 71 78 82.7 70 75 82 87 74 78 85 91.0 76 81 88 94
MBh 45.8 46.8 50.0 53.4 44.7 45.7 48.8 52.2 43.6 44.6 47.6 50.9 42.6 43.5 46.5 49.7 40.4 41.3 44.1 47.2 37.5 38.3 40.9 43.7
S/T 0.88 0.83 0.67 0.5 0.92 0.86 0.70 0.52 0.94 0.88 0.72 0.5 0.97 0.91 0.74 0.55 1.00 0.94 0.77 0.6 1.00 0.95 0.77 0.58
∆T 23 22 19 15 24 23 20 16 24 23 20 16 24 23 20 16 23 22 19 16 22 21 18 15
kW 2.58 2.65 2.75 2.9 2.82 2.89 3.00 3.11 3.03 3.10 3.22 3.3 3.21 3.29 3.42 3.55 3.37 3.45 3.59 3.7 3.50 3.59 3.73 3.87
Amps 10.3 10.5 10.9 11.2 11.1 11.3 11.7 12.1 12.0 12.3 12.7 13.1 12.8 13.1 13.5 14.0 13.6 13.9 14.3 14.9 14.3 14.7 15.2 15.7
HI PR 133 143 151 157.9 149 161 170 177 170 183 193 201.5 194 208 220 229 218 234 248 258.1 241 259 273 285
LO PR 63 67 73 77.7 66 71 77 82 69 73 80 85.3 72 77 84 90 76 81 88 93.9 78 84 91 97
52.4 43.8 44.8 47.9 51.2 41.7 42.6 45.5 48.6 38.6 39.4 42.1 45.0
MBh 47.1 48.2 51.5 55.0 46.0 47.0 50.3 53.7 44.9 45.9 49.1
S/T 0.93 0.87 0.71 0.5 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.6 1.00 0.95 0.78 0.58 1.00 1.00 0.81 0.6 1.00 1.00 0.81 0.61
∆T 22 21 19 15 23 22 19 15 23 22 19 15 22 22 19 15 21 22 19 15 20 20 17 14
kW 2.61 2.67 2.77 2.9 2.85 2.92 3.03 3.14 3.06 3.13 3.25 3.4 3.24 3.32 3.45 3.58 3.40 3.49 3.62 3.8 3.54 3.63 3.77 3.91
10.4 10.6 11.0 11.3 11.2 11.4 11.8 12.2 12.1 12.4 12.8 13.2 12.9 13.2 13.6 14.1 13.7 14.0 14.5 15.0 14.5 14.8 15.3 15.9
Amps
HI PR 135 145 153 159.4 151 162 172 179 172 185 195 203.5 196 210 222 232 220 237 250 260.7 243 262 276 288
LO PR 63 67 74 78.4 67 71 78 83 70 74 81 86.1 73 78 85 90 77 82 89 94.8 79 84 92 98
MBh 43.0 43.8 45.9 48.9 42.0 42.8 44.8 47.8 41.0 41.8 43.7 46.7 40.0 40.7 42.7 45.5 38.0 38.7 40.5 43.3 35.2 35.9 37.6 40.1
S/T 0.89 0.86 0.78 0.63 0.93 0.89 0.81 0.65 0.95 0.92 0.83 0.67 0.98 0.95 0.85 0.69 1.00 0.98 0.89 0.72 1.00 0.99 0.89 0.72
∆T 25 25 23 20 26 25 24 21 26 25 24 21 26 25 24 21 25 25 24 20 23 23 22 19
kW 2.53 2.60 2.69 2.80 2.76 2.83 2.94 3.05 2.97 3.04 3.16 3.28 3.15 3.23 3.35 3.48 3.30 3.39 3.52 3.65 3.44 3.52 3.66 3.80
Amps 10.1 10.4 10.7 11.0 10.9 11.1 11.5 11.9 11.8 12.1 12.4 12.9 12.6 12.8 13.3 13.7 13.3 13.6 14.1 14.6 14.1 14.4 14.9 15.4
HI PR 130 140 148 155 146 158 166 174 167 179 189 197 190 204 216 225 213 230 242 253 236 254 268 279
LO PR 62 65 71 76 65 69 75 80 68 72 78 84 71 75 82 88 74 79 86 92 77 82 89 95
MBh 46.6 47.5 49.7 53.0 45.5 46.4 48.5 51.8 44.4 45.3 47.4 50.6 43.3 44.1 46.2 49.3 41.1 41.9 43.9 46.9 38.1 38.9 40.7 43.4
S/T 0.93 0.89 0.81 0.65 0.96 0.93 0.84 0.68 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.92 0.75 1.00 1.00 0.93 0.75
25 25 23 20 25 25 24 20 24 24 23 20 22 22 22 19
∆T 25 24 23 20 25 25 23 20
kW 2.61 2.67 2.77 2.88 2.85 2.92 3.03 3.14 3.06 3.13 3.25 3.38 3.24 3.32 3.45 3.58 3.40 3.49 3.62 3.76 3.54 3.63 3.77 3.91
10.4 10.6 11.0 11.3 11.2 11.4 11.8 12.2 12.1 12.4 12.8 13.2 12.9 13.2 13.6 14.1 13.7 14.0 14.5 15.0 14.5 14.8 15.3 15.9
Amps
HI PR 135 145 153 159 151 162 172 179 172 185 195 203 196 210 222 232 220 237 250 261 243 262 276 288
LO PR 63 67 74 78 67 71 78 83 70 74 81 86 73 78 85 90 77 82 89 95 79 84 92 98
MBh 48.0 48.9 51.2 54.6 46.8 47.7 50.0 53.3 45.7 46.6 48.8 52.1 44.6 45.5 47.6 50.8 42.4 43.2 45.2 48.3 39.3 40.0 41.9 44.7
S/T 0.97 0.94 0.85 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.90 0.73 1.00 1.00 0.93 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.79
∆T 24 23 22 19 24 24 22 19 23 24 22 19 23 23 23 20 22 22 22 19 20 20 21 18
kW 2.63 2.70 2.80 2.90 2.87 2.95 3.06 3.17 3.09 3.16 3.28 3.41 3.27 3.36 3.48 3.62 3.43 3.52 3.65 3.80 3.57 3.66 3.80 3.95
Amps 10.5 10.7 11.0 11.4 11.3 11.5 11.9 12.3 12.2 12.5 12.9 13.4 13.0 13.3 13.7 14.2 13.8 14.1 14.6 15.1 14.6 14.9 15.4 16.0
HI PR 136 146 154 161 152 164 173 181 173 187 197 206 197 213 224 234 222 239 252 263 245 264 279 291
LO PR 64 68 74 79 68 72 79 84 70 75 82 87 74 79 86 91 77 82 90 96 80 85 93 99
1600
85
1800
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
1400
1600
80
1800
1400
SS-GSC13 www.goodmanmfg.com 15
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
P
roduct SPecificationS
expAnded rAtinGS — GSC130601d*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 50.0 51.8 56.8 - 47.5 49.2 53.9 - 44.0 45.6 49.9 -
24 22 18 12 24 22 18 13 24 22 18 12 22 20 17 12
11.9 12.2 12.5 - 12.8 13.1 13.5 - 13.9 14.2 14.7 - 14.8 15.2 15.7 - 15.7 16.1 16.6 - 16.7 17.1 17.6 -
11.9 12.2 12.5 13.0 12.8 13.1 13.5 14.0 13.9 14.2 14.7 15.2 14.8 15.2 15.7 16.2 15.7 16.1 16.6 17.3 16.7 17.1 17.6 18.3
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
∆T 21 18 14 - 21 18 14 - 21 18 14 - 21 18 14 - 21 18 14 - 20 17 13 -
S/T 0.66 0.55 0.38 - 0.68 0.57 0.39 - 0.70 0.58 0.40 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.75 0.63 0.44 -
MBh 48.1 49.9 54.7 - 47.0 48.7 53.4 - 45.9 47.6 52.1 - 44.8 46.4 50.9 - 42.5 44.1 48.3 - 39.4 40.8 44.8 -
kW 2.92 2.99 3.11 - 3.19 3.27 3.40 - 3.43 3.52 3.65 - 3.64 3.73 3.87 - 3.82 3.91 4.06 - 3.97 4.07 4.23 -
1400
HI PR 126 136 143 - 141 152 161 - 161 173 183 - 183 197 208 - 206 222 234 - 228 245 259 -
Amps 11.5 11.7 12.1 - 12.4 12.6 13.1 - 13.4 13.7 14.1 - 14.3 14.6 15.1 - 15.2 15.5 16.0 - 16.1 16.4 17.0 -
LO PR 56 60 66 - 60 63 69 - 62 66 72 - 65 69 76 - 68 73 79 - 71 75 82 -
∆T 20 18 13 - 21 18 14 - 21 18 14 - 21 18 14 - 21 18 13 - 19 17 13 -
S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.78 0.65 0.45 - 0.78 0.65 0.45 -
MBh 52.2 54.1 59.2 - 50.9 52.8 57.9 - 49.7 51.5 56.5 - 48.5 50.3 55.1 - 46.1 47.8 52.3 - 42.7 44.3 48.5 -
kW 3.01 3.08 3.20 - 3.28 3.37 3.50 - 3.53 3.62 3.76 - 3.75 3.84 3.99 - 3.93 4.03 4.18 - 4.09 4.19 4.35 -
1600
70
HI PR 130 140 148 - 146 157 166 - 166 178 188 - 189 203 215 - 212 229 241 - 235 253 267 -
Amps 11.8 12.0 12.4 - 12.7 13.0 13.4 - 13.8 14.1 14.5 - 14.7 15.0 15.5 - 15.6 16.0 16.5 - 16.5 16.9 17.5 -
LO PR 58 62 68 - 61 65 71 - 64 68 74 - 67 71 78 - 70 75 82 - 73 77 84 -
MBh 53.7 55.7 61.0 - 52.5 54.4 59.6 - 51.2 53.1 58.2
∆T 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 20 17 13 - 18 16 12 -
S/T 0.71 0.60 0.41 - 0.74 0.62 0.43 - 0.76 0.63 0.44 - 0.78 0.65 0.45 - 0.81 0.68 0.47 - 0.82 0.68 0.47 -
kW 3.04 3.11 3.23 - 3.32 3.40 3.53 - 3.56 3.65 3.79 - 3.78 3.88 4.03 - 3.97 4.07 4.23 - 4.13 4.23 4.40 -
HI PR 131 141 149 - 147 158 167 - 167 180 190 - 191 205 217 - 215 231 244 - 237 255 269 -
Amps
LO PR 59 62 68 - 62 66 72 - 64 69 75 - 68 72 79 - 71 76 82 - 73 78 85 -
1800
MBh 49.0 50.4 54.6 58.6 47.8 49.2 53.3 57.2 46.7 48.1 52.0 55.8 45.5 46.9 50.8 54.5 43.3 44.5 48.2 51.7 40.1 41.3 44.7 47.9
S/T 0.75 0.67 0.51 0.33 0.77 0.69 0.52 0.34 0.79 0.71 0.54 0.35 0.82 0.73 0.55 0.36 0.85 0.76 0.58 0.37 0.86 0.77 0.58 0.37
∆T 24 22 18 13 24 22 18 13 24 22 18 13 24 23 18 13 24 22 18 13 23 21 17 12
kW 2.95 3.02 3.14 3.26 3.22 3.30 3.43 3.56 3.46 3.55 3.68 3.83 3.67 3.77 3.91 4.06 3.85 3.95 4.10 4.26 4.01 4.11 4.27 4.43
1400
Amps 11.6 11.8 12.2 12.6 12.5 12.8 13.2 13.6 13.5 13.8 14.3 14.8 14.4 14.8 15.2 15.8 15.3 15.7 16.2 16.8 16.2 16.6 17.1 17.8
HI PR 127 137 145 151 143 154 162 169 162 175 185 193 185 199 210 219 208 224 237 247 230 248 261 273
LO PR 57 61 66 70 60 64 70 74 63 67 73 77 66 70 76 81 69 73 80 85 71 76 83 88
MBh 53.0 54.6 59.1 63.4 51.8 53.3 57.7 62.0 50.6 52.1 56.4 60.5 49.3 50.8 55.0 59.0 46.9 48.3 52.2 56.1 43.4 44.7 48.4 51.9
S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.89 0.80 0.60 0.39
∆T 24 22 18 12 24 22 18 12
kW 3.04 3.11 3.23 3.35 3.32 3.40 3.53 3.67 3.56 3.66 3.79 3.94 3.78 3.88 4.03 4.18 3.97 4.07 4.23 4.39 4.13 4.24 4.40 4.57
1600
75
HI PR 131 141 149 156 147 159 167 175 168 180 190 199 191 205 217 226 215 231 244 254 237 255 269 281
Amps
LO PR 59 63 68 73 62 66 72 77 65 69 75 80 68 72 79 84 71 76 82 88 73 78 85 91
MBh 54.6 56.2 60.9 65.3 53.4 54.9 59.5 63.8 52.1 53.6 58.1 62.3 50.8 52.3 56.6 60.8 48.3 49.7 53.8 57.7 44.7 46.0 49.8 53.5
S/T 0.81 0.73 0.55 0.35 0.84 0.75 0.57 0.37 0.86 0.77 0.58 0.38 0.89 0.80 0.60 0.39 0.92 0.83 0.63 0.40 0.93 0.83 0.63 0.41
∆T 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 23 21 17 12 21 20 16 11
kW 3.06 3.14 3.26 3.39 3.35 3.43 3.56 3.70 3.60 3.69 3.83 3.98 3.82 3.92 4.07 4.22 4.01 4.11 4.27 4.43 4.17 4.28 4.44 4.61
1800
Amps 12.0 12.3 12.6 13.1 12.9 13.2 13.6 14.1 14.0 14.3 14.8 15.3 14.9 15.3 15.8 16.4 15.9 16.3 16.8 17.4 16.8 17.2 17.8 18.4
HI PR 133 143 151 157 149 160 169 176 169 182 192 201 193 207 219 228 217 233 246 257 240 258 272 284
LO PR 59 63 69 73 63 67 73 78 65 69 76 81 68 73 79 85 72 76 83 89 74 79 86 92
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
16 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
expAnded rAtinGS — GSC130601d* (Cont.)
P
roduct SPecificationS
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
MBh 49.8 50.9 54.4 58.2 48.7 49.7 53.1 56.8 47.5 48.5 51.9 55.4 46.4 47.4 50.6 54.1 44.0 45.0 48.1 51.4 40.8 41.7 44.5 47.6
S/T 0.82 0.77 0.62 0.5 0.85 0.80 0.65 0.48 0.87 0.82 0.66 0.5 0.90 0.84 0.69 0.51 0.93 0.87 0.71 0.5 0.94 0.88 0.72 0.54
∆T 27 26 22 18 27 26 23 18 27 26 23 18 27 26 23 18 27 26 22 18 25 24 21 17
kW 2.98 3.05 3.17 3.3 3.25 3.34 3.46 3.59 3.50 3.58 3.72 3.9 3.71 3.80 3.95 4.10 3.89 3.99 4.14 4.3 4.05 4.15 4.31 4.48
Amps 11.7 11.9 12.3 12.8 12.6 12.9 13.3 13.8 13.6 14.0 14.4 14.9 14.5 14.9 15.4 15.9 15.5 15.8 16.3 16.9 16.3 16.7 17.3 17.9
HI PR 129 138 146 152.4 144 155 164 171 164 177 187 194.5 187 201 212 222 210 226 239 249.3 232 250 264 275
LO PR 58 61 67 71.2 61 65 71 75 63 67 73 78.2 66 71 77 82 70 74 81 86.1 72 77 84 89
MBh 54.0 55.2 58.9 63.0 52.7 53.9 57.6 61.5 51.5 52.6 56.2 60.1 50.2 51.3 54.8 58.6 47.7 48.7 52.1 55.7 44.2 45.2 48.2 51.6
S/T 0.85 0.80 0.65 0.5 0.88 0.83 0.67 0.50 0.90 0.85 0.69 0.5 0.93 0.87 0.71 0.53 0.97 0.91 0.74 0.6 0.97 0.91 0.74 0.56
∆T 26 25 22 18 27 26 22 18 27 26 22 18 27 26 22 18 27 25 22 18 25 24 21 16
kW 3.07 3.14 3.26 3.4 3.35 3.43 3.56 3.70 3.60 3.69 3.83 4.0 3.82 3.92 4.07 4.22 4.01 4.11 4.27 4.4 4.17 4.28 4.44 4.61
Amps 12.0 12.3 12.7 13.1 12.9 13.2 13.6 14.1 14.0 14.3 14.8 15.3 14.9 15.3 15.8 16.4 15.9 16.3 16.8 17.4 16.8 17.2 17.8 18.4
HI PR 133 143 151 157.2 149 160 169 176 169 182 192 200.6 193 207 219 228 217 233 246 257.0 240 258 272 284
LO PR 59 63 69 73.4 63 67 73 78 65 69 76 80.6 68 73 80 85 72 76 83 88.7 74 79 86 92
61.9 51.7 52.9 56.5 60.4 49.1 50.2 53.6 57.3 45.5 46.5 49.7 53.1
MBh 55.6 56.8 60.7 64.9 54.3 55.5 59.3 63.4 53.0 54.2 57.9
S/T 0.89 0.84 0.68 0.5 0.92 0.87 0.70 0.53 0.95 0.89 0.72 0.5 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.6 1.00 0.96 0.78 0.58
∆T 25 24 21 17 26 25 21 17 26 25 21 17 26 25 22 17 25 24 21 17 23 23 20 16
kW 3.09 3.17 3.29 3.4 3.38 3.47 3.60 3.74 3.63 3.73 3.87 4.0 3.86 3.96 4.11 4.26 4.05 4.15 4.31 4.5 4.21 4.32 4.48 4.66
12.1 12.4 12.8 13.2 13.0 13.3 13.8 14.3 14.1 14.5 14.9 15.5 15.1 15.4 15.9 16.5 16.0 16.4 16.9 17.6 17.0 17.4 17.9 18.6
Amps
HI PR 134 144 152 158.7 150 162 171 178 171 184 194 202.6 195 209 221 231 219 236 249 259.5 242 260 275 287
LO PR 60 64 70 74.1 63 67 74 78 66 70 76 81.4 69 74 80 86 72 77 84 89.6 75 80 87 93
MBh 50.7 51.7 54.1 57.7 49.5 50.5 52.9 56.4 48.3 49.3 51.6 55.1 47.2 48.1 50.3 53.7 44.8 45.7 47.8 51.0 41.5 42.3 44.3 47.3
S/T 0.86 0.83 0.75 0.61 0.89 0.86 0.77 0.63 0.91 0.88 0.79 0.64 0.94 0.91 0.82 0.67 0.98 0.94 0.85 0.69 0.99 0.95 0.86 0.70
∆T 29 28 27 23 29 28 27 23 29 28 27 23 29 29 27 23 29 28 27 23 27 26 25 22
kW 3.01 3.08 3.20 3.32 3.28 3.37 3.49 3.63 3.53 3.62 3.76 3.90 3.74 3.84 3.99 4.14 3.93 4.03 4.18 4.35 4.09 4.19 4.35 4.52
Amps 11.8 12.0 12.4 12.9 12.7 13.0 13.4 13.9 13.8 14.1 14.5 15.1 14.7 15.0 15.5 16.1 15.6 16.0 16.5 17.1 16.5 16.9 17.5 18.1
HI PR 130 140 148 154 146 157 166 173 166 178 188 196 189 203 215 224 212 229 241 252 235 253 267 278
LO PR 58 62 68 72 61 65 71 76 64 68 74 79 67 71 78 83 70 75 82 87 73 77 84 90
MBh 54.9 56.0 58.6 62.6 53.6 54.7 57.3 61.1 52.4 53.4 55.9 59.7 51.1 52.1 54.5 58.2 48.5 49.5 51.8 55.3 45.0 45.8 48.0 51.2
S/T 0.89 0.86 0.78 0.63 0.92 0.89 0.80 0.65 0.95 0.91 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 0.99 0.89 0.72
28 28 26 23 29 28 27 23 28 28 26 23 26 26 25 21
∆T 28 28 26 23 28 28 26 23
kW 3.09 3.17 3.29 3.42 3.38 3.47 3.60 3.74 3.63 3.73 3.87 4.02 3.86 3.96 4.11 4.26 4.05 4.15 4.31 4.48 4.21 4.32 4.48 4.66
12.1 12.4 12.8 13.2 13.0 13.3 13.8 14.3 14.1 14.5 14.9 15.5 15.1 15.4 15.9 16.5 16.0 16.4 16.9 17.6 17.0 17.4 17.9 18.6
Amps
HI PR 134 144 152 159 150 162 171 178 171 184 194 203 195 209 221 231 219 236 249 260 242 260 275 287
LO PR 60 64 70 74 63 67 74 78 66 70 76 81 69 74 80 86 72 77 84 90 75 80 87 93
MBh 56.6 57.7 60.4 64.4 55.3 56.3 59.0 62.9 53.9 55.0 57.6 61.4 52.6 53.6 56.2 59.9 50.0 51.0 53.4 56.9 46.3 47.2 49.4 52.7
S/T 0.93 0.90 0.81 0.66 0.97 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.89 0.72 1.00 1.00 0.93 0.75 1.00 1.00 0.93 0.76
∆T 27 27 25 22 27 27 25 22 27 27 25 22 27 27 26 22 26 26 25 22 24 24 24 20
kW 3.12 3.20 3.32 3.45 3.41 3.50 3.63 3.77 3.67 3.76 3.91 4.06 3.89 3.99 4.15 4.31 4.08 4.19 4.35 4.52 4.25 4.36 4.53 4.70
Amps 12.2 12.5 12.9 13.3 13.2 13.5 13.9 14.4 14.3 14.6 15.1 15.6 15.2 15.6 16.1 16.7 16.2 16.6 17.1 17.7 17.1 17.5 18.1 18.8
HI PR 135 146 154 160 152 163 172 180 173 186 196 205 197 212 223 233 221 238 251 262 244 263 278 290
LO PR 61 64 70 75 64 68 74 79 66 71 77 82 70 74 81 86 73 78 85 91 76 81 88 94
1600
85
1800
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
1400
1600
80
1800
1400
SS-GSC13 www.goodmanmfg.com 17
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
P
roduct SPecificationS

AHRI RAtIngs

Outdoor
Unit
GSC130241F* CA*F1824*6B*+EEP 22,800 17,600 13 11 800 4700186
GSC130301(D,E)* CA*F3030*6B*+EEP 27,600 21,000 13 11 950 4705227
GSC130481C* CA*F4961*6A*+EEP 44,500 33,800 13 11 1,600 5528473
GSC130421C* CA*F4860*6B*+EEP 39,500 28,200 13 11 1,400 5528472
GSC130363B* CA*F3642*6C*+EEP 33,400 24,200 13 11 1,200 5528487
GSC130361G* CA*F3642*6C*+EEP 33,400 24,200 13 11 1,200 5528471
GSC130601D* CA*F4961*6A*+EEP 53,000 38,000 13 11 1,600 5528476
GSC130603C* CA*F4961*6A*+EEP 53,000 38,000 13 11 1,600 5528477
GSC130483C* CA*F4961*6A*+EEP 44,500 33,800 13 11 1,600 5528474
GSC130181G* CA*F1824*6B*+EEP 18,000 13,000 13 11 600 5897360
GSC130484BD CA*F4961*6A*+EEP 44,500 33,800 13 11 1,600 6468399
GSC130604BD CA*F4961*6A*+EEP 53,000 38,000 13 11 1,600 6468400
¹ BTU/h
² Seasonal Energy Eciency Rao; tested and rated per AHRI 210/240 ³ Energy Eciency Rao @ 80 °F/67 °F Inside - 95 °F
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• When matching the outdoor unit to the indoor unit, use the piston supplied with the out­door unit or that specified on the piston kit chart supplied with the indoor unit.
• EEP: Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38 is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling me delay.
Coil
Total¹ Sens.¹ SEER² EER³
Cooling Ratings
CFM AHRI #
18 www.goodmanmfg.com SS-GSC13

WIRIng DIAgRAm

0140R00015P-A
T2
SEE RATING PLAT E
OUTDOOR POWER SUPP LY
T1
P
roduct SPecificationS
C
SC
CH
1
2
SR
5
RCCF
S
COMP
X
U
A
IO
C
SA
F
I
A
M
(IF USED)
R
N
X
N
I
U
A
A
M
IO
CM
C
C
USE N.E.C. CLASS 2 WIRE
NOTES:
1) TO INDOOR UNIT LOW VOLTAG E
TERMINAL BLOCK AND INDOOR
THERMOSTAT
2) START ASSIST FACTORY
Y
EQUIPPED WHEN REQUIRED.
C
L1 L2
POLE CONTACTOR ONLY
ALTERNATE DOUBLE
NOTE 1
LVJB
Y
C
YL
BL
COLOR CODE
BK --------------- BLACK
BL --------------- BLUE
BR --------------- BROWN
OR --------------- ORANGE
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
YL ---------------- YELLOW
BL
RD
SC
RD
RD
RD
BKBK
BK
BL
CONTROL BOX
C
L2
T2
T1
L1
YL
WIRING CODE
FACTORY WIRING
YL
RD
IELD WIRING
HIGH VOLT AGE
LOW V OLTAGE
OPTIONAL HIGH VOLT AGE
F
HIGH VOLT AGE
LOW V OLTAGE
YL
YL
YL
F
RCCF
HERM
C
BR
PU
RD
RD
SA
(IF USED)
NOTE 2
COMPONENT CODE
C --------------- CONTACTOR
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
IO -------------- INTERNAL OVERLOAD
LVJB ---------- LOW VOLTAGE JUNCTION BOX
RCCF --------- RUN CAPACITOR FOR COMPRESSOR & FAN
SA ------------- START ASSIST
SC ------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
SR ------------- START RELAY FOR COMPRESSOR (OPTIONAL)
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
High Voltage: Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
USE COPPER
CONDUCTORS ONLY
EQUIPMENT GROUND
S
AUX
MAIN
COMP
BK
RD
R
C
YL
Warning
Wiring is subject to change. Always
BR
BK
PU
BL
1
SR
BK
5
YL
2
L2
T2
L1
T1
POLE CONT ACTOR
ALTERNATE DOUBLE
AUX
MAIN
IO
CM
refer to the wiring diagram or the
SS-GSC13 www.goodmanmfg.com 19
unit for the most up-to-date wiring.
P
roduct SPecificationS
DImensIons
W
D
H
Model
GSC130181G* 26 26 27½
GSC130241F* 23½ 23½ 25¾
GSC130301E* 26 26 30¼
GSC130361G* 29 29 30¼
GSC130421BC* 29 29 30¼
GSC130481C* 29 29 36¼
GSC130601D* 29 29 40

Dimensions

W" D" H"

AccessoRIes

Model Description
ABK-20 Anchor Bracket Kit
ABK-21 Anchor Bracket Kit
ASC-01 An-Short Cycle Kit X X X X X X X
CSR-U-1 Hard-start Kit X X X X X X X
CSR-U-2 Hard-start Kit X
CSR-U-3 Hard-start Kit
FSK01A Freeze Protecon Kit
LSK01A Liquid Line Solenoid Kit
0263M00019 Crankcase Heater X
OT18-60A Outdoor Thermostat X X X X X X X
Contains 20 brackets; four brackets needed to anchor unit to pad ¹ Installed on indoor coil ² Field-installed, non-bleed, expansion valve kit — Condensing units and heat pumps with reciprocang
compressors require the use of start-assist components when used in conjuncon with an indoor coil using a non-bleed thermal expansion valve refrigerant metering device or liquid line solenoid kit.
1
GSC13
018**
X X
X X X X X X X
2
X X X X X X X
GSC13 024**
GSC13 030**
X X X X X
GSC13 036**
GSC13
042**
GSC13 048**
GSC13 060**
Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specications or designs without
notice or without incurring obligations. © 2013 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA.