Goodman Mfg GSC13 User Manual 2

GSC13
Split SyStem Air Conditioner
13 Seer / r-22
to 5 tonS
Nomenclature ....................................... 2
Product Specications .......................... 3
Expanded Cooling Data ....................... 4
AHRI Ratings ....................................... 18
Dimensions ......................................... 18
Wiring Diagram .................................. 19
Accessories .......................................... 20
Standard Features
• Energy-efcient compressor
Quiet condenser fan system
• Factory-installed liquid-line lter drier
• Copper tube/aluminum n coil
For use with R-22 refrigerant;
charged with inert gas for shipping
R-22 piston kit included
Brass liquid and suction service
valves with sweat connections
Contactor with lug connections
Ground lug connection
ETL Listed
SS-GSC13 www.goodmanmfg.com 11/13
Cabinet Features
Louver design sound control top
Steel louver coil guard
Heavy-gauge galvanized-steel cabinet
Attractive Architectural Gray powder-paint nish with 500-hour salt-spray approval
When properly anchored, meets the 2010
Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
* Complete warranty details available from your
local dealer or at www.goodmanmfg.com.
Supersedes 9/13
P
Brand Engineering *
G
Goodman® (Standard
Minor Revision
Feature Set Models)
Engineering *
Product Category Major Revision
S Split System
Electrical
Unit Type 1 208/230 V, 1 Phase, 60 Hz
C Condenser R-22
H Heat Pump R-22 Nominal Capacity
018 1½ Tons 042 3½ Tons
Efficiency 024 2 Tons 048 4 Tons
13 13 SEER 030 2½ Tons 060 5 Tons
036 3 Tons
* Neither used for order entry
or inventory management.
11
A
S
2
1
G
C3036
6,7,8134,5
9110
A
roduct SPecificationS

nomenClAture

2 www.goodmanmfg.com SS-GSC13

SpeCifiCAtionS

P
roduct SPecificationS
GSC13
0181G*
Cooling Capacities
Tonnage 2 3 4 5
Decibels 76 76 72 75 76 76 77
Compressor
RLA 6.8 10.8 13.5 13.4 15.4 19.2 21.8
LRA 40 56 68 74 87 112 137
Condenser Fan Motor
Horsepower 1/8 1/8 1/8 1/6 ¼ ¼ ¼
FLA 0.65 0.65 0.7 1.1 1.5 1.5 1.5
Refrigeration System
Refrigerant Line Size
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Line Size (“O.D.) ¾" ¾" ¾" ⅞" 1⅛" 1⅛" 1⅛"
Refrigerant Connecon Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜"
Sucon Valve Size (“O.D.) ³ ¾" ¾" ¾" ¾" ³ ¾" ³ ⅞" 4 ⅞" 4
Valve Type Sweat Sweat Sweat Sweat Sweat Sweat Sweat
Refrigerant Charge 87 77 66 77 108 128 118
Electrical Data
AC Volts-Hz 208-230/ 60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60 208/230-60
Min. Circuit Ampacity¹ 9.2 14.2 17.6 17.9 20.8 25.5 28.8
Max. Overcurrent Device² 15 25 30 30 35 40 50
Min / Max Volts 197/253 197/253 197/253 197/253 197/253 197/253 197/253
Electrical Conduit Size ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"
Equipment Weight (lbs) 116 116 142 141 141 176 207
Ship Weight (lbs) 130 130 159 159 159 194 225
GSC13
0241F*
GSC13
0301E*
GSC13
0361G*
GSC13
0421C*
GSC13
0481C*
GSC13
0601D*
¹ Wire size should be determined in accordance with Naonal Electrical Codes; extensive wire runs will require larger wire sizes ² Must use me-delay fuses or HACR-type circuit breakers of the same size as noted. ³ Installer will need to supply ¾” to ⅞” adapters for sucon line connecons. ⁴ Installer will need to supply ⅞” to 1⅛” adapters for sucon line connecons.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Charge with refrigerant charge listed on S&R plate; 15’ of ⅜” line included in this charge. System charge must be adjusted per Installaon Instrucons Final Charge Procedure.
SS-GSC13 www.goodmanmfg.com 3
P
roduct SPecificationS
expAnded rAtinGS — GSC130181G*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 16.4 17.0 18.6 - 15.6 16.2 17.7 - 14.4 15.0 16.4 -
22 20 17 12 22 20 17 12 22 20 17 11 20 19 15 11
∆T 22 20 16 11 22 20 17 11
kW 1.05 1.07 1.11 1.15 1.14 1.17 1.21 1.25 1.22 1.25 1.29 1.34 1.29 1.32 1.37 1.42 1.35 1.38 1.43 1.49 1.40 1.44 1.49 1.54
4.4 4.5 4.6 4.8 4.7 4.8 5.0 5.1 5.1 5.2 5.4 5.6 5.4 5.5 5.7 5.9 5.7 5.9 6.1 6.3 6.1 6.2 6.4 6.6
Amps
HI PR 135 146 154 161 152 164 173 180 173 186 196 205 197 212 224 233 222 238 252 263 245 263 278 290
LO PR 61 65 71 76 65 69 75 80 67 72 78 83 71 75 82 88 74 79 86 92 77 82 89 95
MBh 17.9 18.5 20.0 21.5 17.5 18.0 19.5 21.0 17.1 17.6 19.1 20.5 16.7 17.2 18.6 20.0 15.9 16.3 17.7 19.0 14.7 15.1 16.4 17.6
S/T 0.86 0.77 0.58 0.37 0.89 0.79 0.60 0.39 0.91 0.81 0.62 0.40 0.94 0.84 0.64 0.41 0.97 0.87 0.66 0.42 0.98 0.88 0.67 0.43
∆T 21 19 16 11 21 20 16 11 21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10
kW 1.06 1.08 1.12 1.16 1.15 1.18 1.22 1.26 1.23 1.26 1.30 1.35 1.30 1.33 1.38 1.43 1.36 1.39 1.45 1.50 1.41 1.45 1.50 1.56
Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.3 6.1 6.3 6.5 6.7
HI PR 137 147 155 162 154 165 174 182 175 188 198 207 199 214 226 236 224 241 254 265 247 266 281 293
LO PR 62 66 72 77 65 70 76 81 68 72 79 84 71 76 83 88 75 80 87 93 77 82 90 96
4.4 4.5 4.6 - 4.7 4.8 5.0 - 5.1 5.2 5.4 - 5.4 5.5 5.7 - 5.7 5.9 6.1 - 6.1 6.2 6.4 -
∆T 19 17 13 - 19 17 13 - 19 17 13 - 20 17 13 - 19 17 13 - 18 16 12 -
S/T 0.69 0.58 0.40 - 0.72 0.60 0.42 - 0.74 0.61 0.43 - 0.76 0.63 0.44 - 0.79 0.66 0.46 - 0.80 0.66 0.46 -
MBh 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.1 15.6 17.1 - 14.7 15.2 16.7 - 14.0 14.5 15.9 - 12.9 13.4 14.7 -
kW 1.01 1.03 1.07 - 1.10 1.12 1.16 - 1.17 1.20 1.25 - 1.24 1.27 1.32 - 1.30 1.33 1.38 - 1.35 1.38 1.43 -
HI PR 130 140 148 - 146 157 166 - 166 179 189 - 189 203 215 - 213 229 242 - 235 253 267 -
Amps 4.2 4.3 4.5 - 4.6 4.7 4.8 - 4.9 5.0 5.2 - 5.2 5.4 5.5 - 5.5 5.7 5.9 - 5.9 6.0 6.2 -
LO PR 59 63 68 - 62 66 72 - 65 69 75 - 68 72 79 - 71 76 83 - 74 78 86 -
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 -
S/T 0.72 0.60 0.42 - 0.74 0.62 0.43 - 0.76 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.68 0.47 - 0.82 0.69 0.48 -
MBh 17.1 17.7 19.4 - 16.7 17.3 19.0 - 16.3 16.9 18.5 - 15.9 16.5 18.1 - 15.1 15.7 17.2 - 14.0 14.5 15.9 -
kW 1.04 1.06 1.10 - 1.13 1.15 1.20 - 1.21 1.24 1.28 - 1.28 1.31 1.36 - 1.34 1.37 1.42 - 1.39 1.42 1.47 -
HI PR 134 144 152 - 150 162 171 - 171 184 194 - 195 210 221 - 219 236 249 - 242 261 275 -
Amps 4.3 4.4 4.6 - 4.7 4.8 4.9 - 5.0 5.2 5.3 - 5.4 5.5 5.7 - 5.7 5.8 6.0 - 6.0 6.2 6.4 -
LO PR 61 65 71 - 64 68 75 - 67 71 77 - 70 75 81 - 73 78 85 - 76 81 88 -
MBh 17.6 18.3 20.0 - 17.2 17.9 19.6 - 16.8 17.4 19.1
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
S/T 0.75 0.63 0.44 - 0.78 0.65 0.45 - 0.80 0.67 0.46 - 0.83 0.69 0.48 - 0.86 0.72 0.50 - 0.86 0.72 0.50 -
kW 1.05 1.07 1.11 - 1.14 1.17 1.21 - 1.22 1.25 1.29 - 1.29 1.32 1.37 - 1.35 1.38 1.43 - 1.40 1.44 1.49 -
HI PR 135 146 154 - 152 164 173 - 173 186 196 - 197 212 224 - 221 238 252 - 245 263 278 -
Amps
LO PR 61 65 71 - 65 69 75 - 67 72 78 - 71 75 82 - 74 79 86 - 77 82 89 -
MBh 16.1 16.5 17.9 19.2 15.7 16.2 17.5 18.8 15.3 15.8 17.1 18.3 15.0 15.4 16.7 17.9 14.2 14.6 15.8 17.0 13.2 13.5 14.7 15.7
S/T 0.79 0.70 0.53 0.34 0.82 0.73 0.55 0.36 0.84 0.75 0.57 0.36 0.86 0.77 0.58 0.38 0.90 0.80 0.61 0.39 0.90 0.81 0.61 0.39
∆T 22 20 17 12 22 21 17 12 22 21 17 12 23 21 17 12 22 21 17 12 21 19 16 11
kW 1.02 1.04 1.08 1.12 1.11 1.13 1.17 1.22 1.19 1.21 1.26 1.30 1.25 1.28 1.33 1.38 1.31 1.34 1.39 1.44 1.36 1.40 1.45 1.50
Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.8 5.0 5.0 5.1 5.2 5.4 5.3 5.4 5.6 5.8 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.5
HI PR 131 141 149 156 147 159 168 175 168 180 191 199 191 206 217 226 215 231 244 255 237 255 270 281
LO PR 59 63 69 74 63 67 73 78 65 70 76 81 69 73 80 85 72 77 84 89 74 79 86 92
MBh 17.4 17.9 19.4 20.8 17.0 17.5 19.0 20.3 16.6 17.1 18.5 19.9 16.2 16.7 18.1 19.4 15.4 15.8 17.2 18.4 14.3 14.7 15.9 17.1
S/T 0.82 0.73 0.55 0.36 0.85 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.80 0.61 0.39 0.93 0.83 0.63 0.40 0.94 0.84 0.63 0.41
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
525
600
70
675
525
600
75
675
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
4 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
expAnded rAtinGS — GSC130181G* (Cont.)
P
roduct SPecificationS
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
MBh 16.4 16.7 17.9 19.1 16.0 16.3 17.4 18.6 15.6 15.9 17.0 18.2 15.2 15.6 16.6 17.8 14.5 14.8 15.8 16.9 13.4 13.7 14.6 15.6
S/T 0.86 0.81 0.66 0.5 0.90 0.84 0.68 0.51 0.92 0.86 0.70 0.5 0.95 0.89 0.72 0.54 0.98 0.92 0.75 0.6 0.99 0.93 0.76 0.57
∆T 25 24 21 16 25 24 21 17 25 24 21 17 25 24 21 17 25 24 21 17 23 22 19 15
kW 1.03 1.05 1.09 1.1 1.12 1.14 1.19 1.23 1.20 1.22 1.27 1.3 1.27 1.30 1.34 1.39 1.32 1.36 1.41 1.5 1.37 1.41 1.46 1.51
Amps 4.3 4.4 4.5 4.7 4.6 4.7 4.9 5.1 5.0 5.1 5.3 5.5 5.3 5.4 5.6 5.8 5.6 5.8 6.0 6.2 6.0 6.1 6.3 6.5
HI PR 133 143 151 157.3 149 160 169 177 169 182 192 200.8 193 208 219 229 217 234 247 257.2 240 258 272 284
LO PR 60 64 70 74.3 63 68 74 79 66 70 77 81.6 69 74 81 86 73 77 84 89.9 75 80 87 93
MBh 17.7 18.1 19.4 20.7 17.3 17.7 18.9 20.2 16.9 17.3 18.5 19.7 16.5 16.8 18.0 19.2 15.7 16.0 17.1 18.3 14.5 14.8 15.8 16.9
S/T 0.90 0.84 0.68 0.5 0.93 0.87 0.71 0.53 0.95 0.89 0.73 0.5 0.98 0.92 0.75 0.56 1.00 0.96 0.78 0.6 1.00 0.96 0.78 0.59
∆T 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 24 23 20 16 22 22 19 15
kW 1.06 1.08 1.12 1.2 1.15 1.18 1.22 1.26 1.23 1.26 1.30 1.4 1.30 1.33 1.38 1.43 1.36 1.40 1.45 1.5 1.41 1.45 1.50 1.56
Amps 4.4 4.5 4.7 4.8 4.8 4.9 5.0 5.2 5.1 5.3 5.4 5.6 5.5 5.6 5.8 6.0 5.8 5.9 6.1 6.3 6.1 6.3 6.5 6.7
HI PR 137 147 155 162.2 154 165 174 182 175 188 198 207.0 199 214 226 236 224 241 254 265.2 247 266 281 293
LO PR 62 66 72 76.6 65 70 76 81 68 72 79 84.2 71 76 83 88 75 80 87 92.6 77 82 90 96
20.3 17.0 17.4 18.5 19.8 16.1 16.5 17.6 18.8 14.9 15.3 16.3 17.4
MBh 18.3 18.7 19.9 21.3 17.8 18.2 19.5 20.8 17.4 17.8 19.0
S/T 0.94 0.88 0.72 0.5 1.00 0.91 0.74 0.56 1.00 0.94 0.76 0.6 1.00 0.97 0.79 0.59 1.00 1.00 0.82 0.6 1.00 1.00 0.82 0.62
∆T 23 22 19 16 24 23 20 16 24 23 20 16 23 23 20 16 22 22 20 16 20 21 18 15
kW 1.07 1.09 1.13 1.2 1.16 1.19 1.23 1.27 1.24 1.27 1.32 1.4 1.31 1.34 1.39 1.45 1.37 1.41 1.46 1.5 1.43 1.46 1.52 1.57
4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.2 5.2 5.3 5.5 5.7 5.5 5.6 5.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8
Amps
HI PR 138 149 157 163.8 155 167 176 184 176 190 200 209.0 201 216 228 238 226 243 257 267.8 250 269 284 296
LO PR 63 67 73 77.4 66 70 77 82 69 73 80 85.0 72 77 84 89 76 80 88 93.6 78 83 91 97
MBh 16.6 17.0 17.8 19.0 16.3 16.6 17.4 18.5 15.9 16.2 16.9 18.1 15.5 15.8 16.5 17.6 14.7 15.0 15.7 16.8 13.6 13.9 14.5 15.5
S/T 0.91 0.87 0.79 0.64 0.94 0.91 0.82 0.66 0.96 0.93 0.84 0.68 0.99 0.96 0.86 0.70 1.00 0.99 0.90 0.73 1.00 1.00 0.91 0.73
∆T 26 26 25 21 27 26 25 21 27 26 25 22 27 26 25 22 26 26 25 21 24 24 23 20
kW 1.04 1.06 1.10 1.14 1.13 1.15 1.20 1.24 1.21 1.24 1.28 1.33 1.28 1.31 1.36 1.41 1.34 1.37 1.42 1.47 1.39 1.42 1.47 1.53
Amps 4.3 4.4 4.6 4.7 4.7 4.8 4.9 5.1 5.0 5.2 5.3 5.5 5.4 5.5 5.7 5.9 5.7 5.8 6.0 6.2 6.0 6.2 6.4 6.6
HI PR 134 144 152 159 150 162 171 178 171 184 194 203 195 210 221 231 219 236 249 260 242 261 275 287
LO PR 61 65 71 75 64 68 74 79 67 71 77 82 70 74 81 87 73 78 85 91 76 81 88 94
MBh 18.0 18.4 19.3 20.5 17.6 18.0 18.8 20.1 17.2 17.5 18.4 19.6 16.8 17.1 17.9 19.1 15.9 16.2 17.0 18.2 14.8 15.0 15.8 16.8
S/T 0.94 0.91 0.82 0.66 0.97 0.94 0.85 0.69 1.00 0.96 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.93 0.76 1.00 1.00 0.94 0.76
26 26 24 21 26 26 25 21 24 25 24 21 23 23 23 20
∆T 26 26 24 21 26 26 24 21
kW 1.07 1.09 1.13 1.17 1.16 1.19 1.23 1.27 1.24 1.27 1.32 1.36 1.31 1.34 1.39 1.45 1.37 1.41 1.46 1.51 1.43 1.46 1.52 1.57
4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.2 5.2 5.3 5.5 5.7 5.5 5.6 5.8 6.0 5.8 6.0 6.2 6.4 6.2 6.3 6.5 6.8
Amps
HI PR 138 149 157 164 155 167 176 184 176 190 200 209 201 216 228 238 226 243 257 268 250 269 284 296
LO PR 63 67 73 77 66 70 77 82 69 73 80 85 72 77 84 89 76 80 88 94 78 83 91 97
MBh 18.6 18.9 19.8 21.2 18.1 18.5 19.4 20.7 17.7 18.1 18.9 20.2 17.3 17.6 18.4 19.7 16.4 16.7 17.5 18.7 15.2 15.5 16.2 17.3
S/T 0.98 0.95 0.86 0.70 1.00 0.98 0.89 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.94 0.76 1.00 1.00 0.98 0.79 1.00 1.00 0.98 0.80
∆T 25 25 23 20 25 25 23 20 24 25 23 20 24 24 24 20 22 23 23 20 21 21 22 19
kW 1.08 1.10 1.14 1.18 1.17 1.20 1.24 1.29 1.25 1.28 1.33 1.38 1.32 1.36 1.41 1.46 1.39 1.42 1.47 1.53 1.44 1.48 1.53 1.59
Amps 4.5 4.6 4.7 4.9 4.8 4.9 5.1 5.3 5.2 5.3 5.5 5.7 5.6 5.7 5.9 6.1 5.9 6.0 6.2 6.5 6.2 6.4 6.6 6.8
HI PR 140 150 159 165 157 169 178 186 178 192 202 211 203 218 231 240 228 246 259 271 252 271 287 299
LO PR 63 67 73 78 67 71 78 83 69 74 81 86 73 78 85 90 76 81 89 94 79 84 92 98
600
85
675
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects AHRI condions Amps = outdoor unit amps (comp.+fan)
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
525
600
80
675
525
SS-GSC13 www.goodmanmfg.com 5
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power Design Subcooling 9 ±3 °F @ the liquid service valve, ARI 95 test condions
P
roduct SPecificationS
expAnded rAtinGS — GSC130241f*
Outdoor Ambient Temperature
65 75 85 95 105 115
Entering Indoor Wet Bulb Temperature
- 20.8 21.5 23.6 - 19.7 20.5 22.4 - 18.3 19.0 20.8 -
20 19 15 10 20 19 15 11 20 18 15 10 19 17 14 10
∆T 20 18 15 10 20 19 15 10
kW 1.54 1.58 1.63 1.69 1.67 1.71 1.78 1.84 1.79 1.84 1.90 1.97 1.90 1.95 2.02 2.09 1.99 2.04 2.11 2.19 2.07 2.12 2.20 2.28
7.2 7.3 7.5 7.8 7.7 7.8 8.1 8.3 8.2 8.4 8.6 8.9 8.7 8.9 9.2 9.5 9.2 9.4 9.7 10.0 9.7 9.9 10.2 10.5
Amps
HI PR 140 150 159 166 157 169 178 186 178 192 203 211 203 218 231 241 228 246 260 271 252 272 287 299
LO PR 59 63 69 74 63 67 73 78 65 69 76 81 69 73 80 85 72 77 84 89 74 79 86 92
MBh 22.7 23.4 25.3 27.2 22.2 22.8 24.7 26.5 21.7 22.3 24.1 25.9 21.1 21.8 23.6 25.3 20.1 20.7 22.4 24.0 18.6 19.1 20.7 22.2
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.63 0.41 0.94 0.84 0.64 0.41
∆T 19 18 14 10 19 18 15 10 19 18 15 10 19 18 15 10 19 18 14 10 18 17 14 9
kW 1.55 1.59 1.65 1.71 1.69 1.73 1.79 1.86 1.81 1.85 1.92 1.99 1.92 1.96 2.04 2.11 2.01 2.06 2.13 2.21 2.09 2.14 2.22 2.30
HI PR 141 152 160 167 158 170 180 188 180 194 205 213 205 221 233 243 231 248 262 273 255 274 290 302
Amps 7.3 7.4 7.6 7.8 7.7 7.9 8.1 8.4 8.3 8.5 8.7 9.0 8.8 9.0 9.2 9.5 9.3 9.5 9.7 10.1 9.7 10.0 10.3 10.6
LO PR 60 64 70 74 63 68 74 79 66 70 77 82 69 74 80 86 73 77 84 90 75 80 87 93
7.2 7.3 7.5 - 7.7 7.8 8.1 - 8.2 8.4 8.6 - 8.7 8.9 9.2 - 9.2 9.4 9.7 - 9.7 9.9 10.2 -
∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
S/T 0.67 0.56 0.38 - 0.69 0.58 0.40 - 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.76 0.64 0.44 -
MBh 20.0 20.8 22.7 - 19.6 20.3 22.2 - 19.1 19.8 21.7 - 18.6 19.3 21.1 - 17.7 18.3 20.1 - 16.4 17.0 18.6 -
kW 1.48 1.52 1.57 - 1.61 1.65 1.71 - 1.73 1.77 1.83 - 1.83 1.87 1.94 - 1.91 1.96 2.03 - 1.99 2.04 2.11 -
HI PR 134 144 152 - 150 162 171 - 171 184 194 - 195 210 221 - 219 236 249 - 242 261 275 -
Amps 7.0 7.1 7.3 - 7.5 7.6 7.8 - 8.0 8.1 8.4 - 8.4 8.6 8.9 - 8.9 9.1 9.4 - 9.4 9.6 9.8 -
LO PR 57 61 66 - 60 64 70 - 63 67 73 - 66 70 77 - 69 73 80 - 71 76 83 -
∆T 17 15 11 - 17 15 11 - 17 15 11 - 18 15 12 - 17 15 11 - 16 14 11 -
S/T 0.69 0.58 0.40 - 0.71 0.60 0.41 - 0.73 0.61 0.42 - 0.76 0.63 0.44 - 0.79 0.66 0.45 - 0.79 0.66 0.46 -
MBh 21.7 22.5 24.6 - 21.2 22.0 24.1 - 20.7 21.4 23.5 - 20.2 20.9 22.9 - 19.2 19.9 21.8 - 17.8 18.4 20.2 -
kW 1.52 1.56 1.62 - 1.66 1.70 1.76 - 1.78 1.82 1.89 - 1.88 1.93 2.00 - 1.97 2.02 2.09 - 2.05 2.10 2.17 -
HI PR 138 149 157 - 155 167 176 - 176 190 200 - 201 216 228 - 226 243 257 - 250 269 284 -
Amps 7.2 7.3 7.5 - 7.6 7.8 8.0 - 8.2 8.3 8.6 - 8.6 8.8 9.1 - 9.1 9.3 9.6 - 9.6 9.8 10.1 -
LO PR 59 63 68 - 62 66 72 - 65 69 75 - 68 72 79 - 71 76 83 - 74 78 86 -
MBh 22.3 23.2 25.4 - 21.8 22.6 24.8 - 21.3 22.1 24.2
∆T 17 14 11 - 17 14 11 - 17 14 11 - 17 15 11 - 17 14 11 - 16 13 10 -
S/T 0.72 0.60 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.82 0.69 0.48 - 0.83 0.69 0.48 -
kW 1.54 1.58 1.63 - 1.67 1.71 1.78 - 1.79 1.84 1.90 - 1.90 1.95 2.02 - 1.99 2.04 2.11 - 2.07 2.12 2.19 -
HI PR 140 150 159 - 157 169 178 - 178 192 202 - 203 218 231 - 228 246 259 - 252 271 287 -
Amps
LO PR 59 63 69 - 63 67 73 - 65 69 76 - 69 73 80 - 72 76 84 - 74 79 86 -
MBh 20.4 21.0 22.7 24.4 19.9 20.5 22.2 23.8 19.4 20.0 21.6 23.2 18.9 19.5 21.1 22.7 18.0 18.5 20.1 21.5 16.7 17.2 18.6 19.9
S/T 0.76 0.68 0.51 0.33 0.78 0.70 0.53 0.34 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.86 0.77 0.58 0.37 0.87 0.78 0.59 0.38
∆T 20 19 15 11 20 19 15 11 20 19 15 11 21 19 16 11 20 19 15 11 19 17 14 10
kW 1.50 1.53 1.59 1.65 1.63 1.67 1.73 1.79 1.74 1.79 1.85 1.92 1.85 1.89 1.96 2.03 1.93 1.98 2.05 2.13 2.01 2.06 2.13 2.21
Amps 7.0 7.2 7.4 7.6 7.5 7.7 7.9 8.1 8.0 8.2 8.4 8.7 8.5 8.7 8.9 9.2 9.0 9.2 9.4 9.7 9.4 9.6 9.9 10.2
HI PR 135 146 154 161 152 164 173 180 173 186 196 205 197 212 224 233 222 238 252 263 245 263 278 290
LO PR 58 61 67 71 61 65 71 75 63 67 74 78 67 71 77 82 70 74 81 86 72 77 84 89
MBh 22.1 22.7 24.6 26.4 21.5 22.2 24.0 25.8 21.0 21.7 23.4 25.2 20.5 21.1 22.9 24.5 19.5 20.1 21.7 23.3 18.1 18.6 20.1 21.6
S/T 0.78 0.70 0.53 0.34 0.81 0.73 0.55 0.35 0.83 0.75 0.56 0.36 0.86 0.77 0.58 0.37 0.89 0.80 0.60 0.39 0.90 0.81 0.61 0.39
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
700
800
70
900
700
800
75
900
IDB: Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
6 www.goodmanmfg.com SS-GSC13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power