GPC15 SEER Multi-Position
Package Air Conditioners
Refer to Service Manual RS6300008 for installation, operation, and troubleshooting information.
All safety information must be followed as provided in the Service Manual.
Refer to the appropriate Parts Catalog for part number information.
Models listed on page 3.
Models qualify for the 2009 and 2010 Federal Tax Credits for Energy Efficiency**
**Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax professional if they have questions about the applicability of these credits.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures or services performed by an unqualified person.
Copyright © 2009 Goodman Manufacturing Company, L.P.
RT6322008r3
August 2009
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
GPC1524M41 * *
BRAND:
G: Goodman Bra nd or Distinctions
Cooling/Heating
®
PRODUCT
TYPE:
Package
15 : 15 SE E R
PRODUCT FAMILY:
C: Cooling
H: Heat P um p
PRODUCT
SERIES:
Ra ting
NOMINAL CAPACITY:
24: 24,000 B TUH 30: 30,000 B TUH 36: 36,000 B TUH 42: 42,000 B TUH 48: 48,000 B TUH
CONFIGURATION
H : Ho riz ontal
M: Mul ti Positio n
REFRIGERANT:
2: R-22
4: R-410A
MINOR R EVI SION:
MAJOR REVISION :
VOLTAGE:
1: 208- 230V/ 1ph/60Hz 3: 208- 230v/ 3ph/60Hz 4: 460v/3ph /60Hz
WARNING
WARNING
WARNING
arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment.
2
Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.
Goodman will not be responsible for any injury or property damage
WARNING
HIGH VOLTAGE!
WARNING
WARNING
individuals meeting the requirements of an "entry level technician" as specified by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death.
Installation and repair of this unit should be performed
ONLY by
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
GPC1524M41A* GPC1530M41A* GPC1536M41A* GPC1542M41A* GPC1548M41A*
Models qualify for the 2009 and 2010 Federal Tax Credits
for Energy Efficiency**
**Note that these tax credits are subject to specific requirements set forth in the American Recovery and Reinvestment Act of 2009 and in the Internal Revenue Code. Goodman recommends that consumers consult a tax professional if they have questions about the applicability of these credits.
WARNING
WARNING
WARNING
WARNING
Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices.
The United States Environmental Protection Agency (“EPA”) has issued various regulations re­garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA office.
Do not connect or use any device that is not design certified by Goodman for use with this unit.
WARNING
WARNING
do not store combustible materials or use gasoline or other flammable liquids or vapors in the vicinity of this appliance.
To prevent the risk of property damage, personal injury, or death,
3
PRODUCT DESIGN
GPC Package Cooling Units are designed for outdoor instal­lations only in either residential or light commercial applica­tions and are available in 2, 2-1/2, 3, 3-1/2 and 4 ton sizes. They are designed for 208/230 volt single phase applications.
The connecting ductwork (Supply and Return) can be con­nected for either horizontal or vertical airflow. In the vertical application, a matching Roof Curb is recommended and a horizontal duct cover kit is required.
A return air filter must be installed behind the return air grille(s) or provision must be made for a filter in an accessible loca­tion within the return air duct. The minimum filter area should not be less than those sizes listed in the Specification Sec­tion. Under no circumstances should the unit be operated without return air filters.
A 3/4” PVC pipe is provided for removal of condensate water from the indoor coil In order to provide proper condensate flow, a drain trap is supplied and shipped loose inside the unit for field installation. (Do not reduce the drain line size.)
Refrigerant flow control is achieved by use of restrictor ori­fices. GPC units use the FasTest Access Fitting System with a saddle that is either soldered to the suction and liquid lines or is fastened with a locking nut to the access fitting box (core) and then screwed into the saddle. Do not re-
move the core from the saddle until the refrigerant charge has been removed. Failure to do so could re­sult in property damage or personal injury.
The single phase units use permanent split capacitor (PSC) design compressors. Starting components are therefore not required for these units. A low microfarad run capacitor as­sists the compressor to start and remains in the circuit dur­ing operation.
The outdoor fan motors are single phase capacitor type mo­tors. GPC1524-48M41* units have X-13 indoor blower mo­tors that are energized by a 24V signal from the thermostat and are constant torque motors with very low power con­sumption. The X-13 features an integral control module.
Air for condensing (cooling cycle) is drawn through the out­door coil by a propeller fan, and is discharged vertically out the top of the unit. The outdoor coil is designed for .0 static. No additional restriction (ductwork) shall be applied.
Conditioned air is drawn through the filter(s), field installed, across the coil and back into the conditioned space by the indoor blower.
GPC15 models use Copeland Scroll Compressors. There
are a number of design characteristics which are different from the traditional reciprocating compressor.
- Due to their design Scroll Compressors are inherently more tolerant of liquid refrigerant. NOTE: Even though the compressor section of a Scroll compressor is more toler­ant of liquid refrigerant, continued floodback or flooded start conditions may wash oil from the bearing surfaces causing premature bearing failure.
- Scroll Compressors use white oil which is compatible with 3GS oil which may be used if additional oil is re­quired.
- Operating pressures and amp draws may differ from stan­dard reciprocating compressors. This information may be found in the "Cooling Performance Data" section.
Location and Clearances
NOTE: To ensure proper condensate drainage, unit must be installed in a level position.
48" MIN
12" MIN
36" MIN (FOR SERVICE)
.
12" MIN
3"
MIN
36" MIN
(FOR SERVICE)
Outside Slab Installation - Multi-positional (M)
NOTE: Roof overhang should be no more than 36" and
provisions made to deflect the warm discharge air out from the overhang.
Minimum clearances are required to avoid air recirculation and keep the unit operating at peak efficiency.
4
PRODUCT DESIGN
Roof Curb
Rooftop Installation - Multi-positional (M)
NOTE: To ensure proper condensate drainage, unit must be
installed in a level position. In installations where the unit is installed above ground level
and not serviceable from the ground (Example: Roof Top in­stallations), the installer must provide service platform for ser­vice person with rails or guards in accordance with local codes or ordinances or in their absence with the latest edition of the Uniform Mechanical Code Section 305.
NOTE: Unit can also use roof curb (and platform for leveling, where necessary) to utilize bottom discharge.
WARNING
TO PREVENT POSSIBLE PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT POSITION DURING ALL RIGGING AND MOVING OPERATIONS. TO FACILITATE LIFTING AND MOVING IF A CRANE IS USED, PLACE THE UNIT IN AN ADEQUATE CABLE SLING.
IMPORTANT: If using bottom discharge with roof curb,
ductwork should be attached to the curb prior to installing the unit.
Refer to Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.
5
PRODUCT DESIGN
GPC15[24-48]M41*
HKR ELECTRICAL DATA
Circuit #1 Circuit #2
Model and Heat Kit Usage
GPC1524M41*
HKR05A,CA HKR08A,CA HKR10A,CA 45 / 51 60 / 60 ---- ---- 9.50 / 32,400
GPC1530M41*
HKR05A,CA 24 / 27 30 / 30 -- -- 4.75 / 16,200 HKR08A,CA 34 / 39 40 / 40 -- -- 7.0 / 23,800 HKR10A,CA 45 / 52 60 / 60 -- -- 9.5 / 32,400 HKR15A,CA 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
GPC1536M41*
HKR05A,CA HKR08A,CA HKR10A,CA HKR15A,CA 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
GPC1542M41*
HKR05A,CA 24 / 27 30 / 30 -- -- 4.75 / 16,200 HKR08A,CA 34 / 39 40 / 40 -- -- 7.0 / 23,800 HKR10A,CA 45 / 52 60 / 60 -- -- 9.5 / 32,400 HKR15A,CA 45 / 52 60 / 60 22 / 25 30 / 30 14.25 / 48,600
GPC1548M41*
HKR05A,CA HKR08A,CA HKR10A,CA HKR15A,CA HKR20A,CA 46 / 52 60 / 60 43 / 49 60 / 60 19.50 / 66,500
Minimum Ci rcuit
Ampacity
at 208 / 240V
24 / 27 30 / 30 ---- ---- 4 .7 5 / 16,200 33 / 28 40 / 40 ---- ---- 7 .0 0 / 23,800
24 / 27 30 / 30 ---- ---- 4 .7 5 / 16,200 34 / 39 40 / 40 ---- ---- 7 .0 0 / 23,800 45 / 52 60 / 60 ---- ---- 9 .5 0 / 32,400
25 / 28 30 / 30 ---- ---- 4 .7 5 / 16,200 34 / 40 40 / 40 ---- ---- 7 .0 0 / 23,800 46 / 53 60 / 60 ---- ---- 9 .5 0 / 32,400 46 / 52 60 / 60 22 / 25 30 / 3 0 14.25 / 48, 600
Maximum Maximum
Overcurrent Overcurrent
Protection (amps) Protection (amps)
at 208 / 240V at 208 / 240V
Minimum Circuit
Ampacity
at 208 / 240V
kW & BTU
at 240V
Actual
IMPORTANT NOTE: A separate power supply is required for the HKR heater kit.
Heating kW Correction Factor
Supply Votage
Correction Factor
Multiply rated kW by correction factor to get actual kW
All wires and overcurrent protection devices are sized for use with electric heaters only and without
WARNING
WARNING
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during refrigeration cycle.
240 230 220 210 208
1.0 0.93 0.85 0.78 0.76
6
PRODUCT DIMENSIONS
GPC15[24-48]M41*
SUCTION/LIQUID PRESSURE PORT
CONDENSATE DRAIN CONNECTION 3/4” NPT FEMALE
47
18 7/8
POWER WIRE ENTRANCE
4 1/8
2 1/8
6 ½
8
?
B
3
CONTROL WIRE ENTRANCE
1 3/8
51
?
16
5 ½
16
A
B
2 34
SUPPLY
RETURN
MEDIUM CHASSIS
GPC1524M41* GPC1530M41* GPC1536M41*
LARGE CHASSIS
GPC1542M41* GPC1548M41*
BLOWER ACCESS PANEL
7
PACKAGE COOLING SPECIFICATIONS
GPC15[24-48]M41A*
COOLING CAPACITY UNIT ELECTRICAL SPECIFICATION
COMPRESSOR
CONDENS E R FAN MOTOR
CONDENS E R FAN CONDENS E R COIL
EVAPORATOR BLOWER MOTOR
EVAPORATOR BLOWER
EVAPORATOR COIL
GENE RAL INFORM ATION
COOLING CAPACITY, BTUH 24,000 28,000 35,000 40,000 45,500 SEER / EER 14.5 / 12. 0 14.5 / 12. 0 14.5 / 12. 0 14.5 / 12. 0 15.0 / 12.0 VOLTAGE (NAMEPLATE) 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 AMPS 15.8 17.5 20.1 22.2 24.2 MIN CIRCUIT AMP ACITY 19.0 21.0 24.2 26.7 29.2 MAX OVERCURRENT PROTECTION 30 35 40 40 45 TYPE SCROLL SCROLL SCROLL SCROLL SCROLL RATED LOAD AMPS 12.8 14.1 16.7 17.9 19.9 LOCKED ROTOR AMPS 58.3 73.0 79.0 112.0 109.0 HORSEPOWER 1/6 1/4 1/4 1/4 1/4 RPM 815 837 837 1075 1075 FULL LOAD AMPS 1.1 1.5 1.5 1.4 1.4 LOCKED R OTOR AMPS 1.7 3.0 3.0 2.9 2.9 BLADE DIAMETER (I NCHES) 22 22 22 22 22 NUMBER OF BLADES 3 3 3 3 3 FACE ARE A (SQ. F T.) 12.33 12.33 12.33 15.38 15.38 NUMBER OF ROWS 122 2 2 FINS PER INCH 24 16 16 16 16 HORSE PO WER - N O. O F S P EEDS 1/2 - 5 1/2 - 5 1/2 - 5 3/4 - 5 3/4 - 5 FULL LOAD AMPS 1.9 1.9 1.9 2.9 2.9 LOCKED ROTOR AMPS --- --- --- --- --­MOTOR SPE ED TAP-COOLING X-13 T2 T2 T2 T2 T2 RPM 1,050 1,050 1,050 1,050 1,050 DIAMETER X WIDTH (INCHES) 10 x 9 10 x 9 10 x 9 10 x 9 10 x 9 RATED SCFM COOLING 850 1,050 1,150 1,350 1,350 MAX EXTERNAL STATIC PRESS ("w.c.) 0.5 0.5 0.5 0.5 0.5 FACE AREA (SQ. FT.) 4.52 4.52 4.52 6.17 6.17 NUMBER OF ROWS 334 4 4 FINS PER INCH 16 16 14 14 14 FILTER SIZE * 25 x 25 x 1 25 x 25 x 1 25 x 25 x 1 (2) 20 x 20 x 1 (2) 20 x 20 x 1 DRAIN SIZE (INCHES) 3 /4" 3/4" 3/4" 3/4" 3/4" EXPANSION DEVICE 0.057 0.065 0.068 0.072 0.076 REFRIGERANT CHARGE R410A (OZS.) 80 100 115 140 170
POWE R SUPPLY CONDUIT KN OCKOUT SIZE (INCHES)
LOW VOLTAGE CONDUIT KN OCKOUT SIZE (INCHES)
SHIPPING WEIGHT (LBS.) 375 384 416 459 459 OPERATING WEIGHT (LBS.) 354 363 395 438 438
GPC1 52 4M41* GPC1530M41* GPC1536M41* GPC1542M41* GPC1548M41*
3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4 3/4, 1, 1-1/4
1/2 1/2 1/2 1/2 1/2
(1)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
*
Calculated external filter size based on air velocity of 300 ft/min.
Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
Unit specifications are subject to change without notice. ALWAYS refer to the units serial plate for the most up-to-date general and electrical information.
IMPORTANT: While this data is presented as a guide, it is important to electrically connect the unit and properly size wires and fuses/circuit breakers
in accordance with the National Electrical Code and/or all local codes. Data shown is w/o electric heaters.
All wires and overcurrent protection devices are sized for use with electric heaters only and without
WARNING
WARNING
refrigeration. If heaters are not installed with above wire size, overheating and fire could occur. See PACKAGE COOLING SPECIFICATIONS section for minimum circuit ampacity and maximum overcurrent protection during refrigeration cycle.
8