•Refer to Service Manual RS6200005 for installation, op-
eration, and troubleshooting information.
•All safety information must be followed as provided in the
Service Manual.
•Refer to the appropriate Parts Catalog for part number
information.
on page 3
®
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property
damage or personal injury due to improper service procedures or services
performed by an unqualified person.
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
Disconnect ALL power before servicing or installing this unit. Multiple
power sources may be present. Failure to do so may cause property
damage, personal injury or death.
Installation and repair of this unit should be performed ONLY by individuals meeting the requirements of an "entry level technician" as specified
by the Air Conditioning and Refrigeration Institute (ARI). Attempting to
install or repair this unit without such background may result in product
damage, personal injury or death.
Goodman will not be responsible for any injury or property damage arising
from improper service or service procedures. If you install or perform
service on this unit, you assume responsibility for any personal injury or
property damage which may result. Many jurisdictions require a license to
install or service heating and air conditioning equipment.
PRODUCT IDENTIFICATION
The model number is used for positive identification of component parts used in manufacturing. Please use this number
when requesting service or parts information.
SSZ160241A*
SSZ160361A*
SSZ160481A*
SSZ160601A*
* Indicates minor revision & is not used for order entry or inventory management
WARNING
WARNING
WARNING
WARNING
WARNING
WARNING
The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local
EPA office.
To prevent the risk of property damage, personal injury, or death, do not
store combustible materials or use gasoline or other flammable liquids or
vapors in the vicinity of this appliance.
Do not connect or use any device that is not design certified by Goodman
for use with this unit. Serious property damage, personal injury, reduced
unit performance and/or hazardous conditions may result from the use of
such non-approved devices.
3
PRODUCT DESIGN
SSZ16 models are available in 2, 3, 4 and 5 ton sizes and
use R-410A refrigerant. They are designed for 208/230 volt
single phase applications.
The condenser air is pulled through the condenser coil by a
direct drive propeller fan. This condenser air is then discharged out of the top of the cabinet.
These units are designed for free air discharge, so no additional resistance like duct work shall be attached.
The suction and liquid line connections on present models
are of the sweat type for field piping with refrigerant type copper. Front seating valves are factory installed to accept the
field run copper. The total refrigerant charge for a normal installation is factory installed in the condensing unit. SSZ units
are charged for the matching evaporator coil and a 15 foot
refrigerant line set.
Systems should be properly sized by heat gain and loss
calculations made according to methods of the Air Conditioning Contractors Association (ACCA) or equivalent. It is
the contractors responsibility to ensure the system has adequate capacity to heat or cool the conditioned space.
SSZ16 models use high-efficiency Copeland® Scroll
"Ultratech" compressors which are specifically designed for
R-410A refrigerant. There are a number of design characteristics which are different from the scroll compared to the traditional reciprocating compressor.
"Ultratech" Series scroll compressors will not have a discharge thermostat, some of the early model scroll compressors required discharge thermostats.
Due to their design Scroll compressors are inherently more
tolerant of small quantities of liquid refrigerant.
NOTE: Even though the compressor section of a Scroll compressor is more tolerant of liquid refrigerant, continued
floodback or flooded start conditions may wash oil from the
bearing surfaces causing premature bearing failure.
"Ultratech" Series scroll compressors use "POE" or
polyolester oil which is NOT compatible with mineral oil based
lubricants like 3GS. "POE" oil must be used if additional oil
is required.
These clearances will help avoid air recirculation. If installing
two or more units at the same location, allow at least 24
inches between units. If only one side is restricted (for example, against the outside wall of a house), the unit may be
placed as close as 8" to that one wall.
DO NOT locate the unit:
* Directly under a vent termination for a gas appliance.
* Within 3 feet of a clothes drier vent
* Where the refreezing of defrost water would create
a hazard
* Where water may rise into the unit.
NOT
RECOMMENDED
BBB
AAAAA
C
AA
A
Model TypeABCAA
Residential
AA
10"10"18"20"
AA
C
AA
CC
B
AA
OK!
OK!
OK!
OK!
OK!
OK!
WARNING
To avoid possible injury, explosion or death, practice
safe handling of refrigerants.
Operating pressures and amp draws may differ from standard reciprocating and/or scroll compressors. This information may be found in the "Cooling Performance Data" section.
This unit is for outdoor installation only. Refer to minimum
figure for clearances from the sides of the unit to full walls
and other objects.
NOTE: This unit cannot be completely enclosed. At least
one side must be unrestricted.
4
Light Commercial
12'12"18"24"
ModelDimensions - W x D x H
SSZ160241A*29 x 29 x 38¼
SSZ160361A*35½ x 35½ x 38¼
SSZ160481A*35½ x 35½ x 38¼
SSZ160601A*35½ x 35½ x 38¼
HEAT PUMP SPECIFICATIONS
SSZ160241A*
SSZ160361A*
SSZ160481A*
SSZ160601A*
Cooling Capacity, BTUH
24,00036,00048,00060,000
Compressor
R.L. Amps
13.414.119.825.6
L.R. Amps
58.377.0109.0118.0
Low Pressure Switch
Open
22 PSIG22 PSIG22 PSIG22 PSIG
Close
50 PSIG50 PSIG50 PSIG50 PSIG
High Pressure Switch
Open
610 PSIG610 PSIG610 PSIG610 PSIG
Close
420 PSIG420 PSIG420 PSIG420 PSIG
Condenser Fan Motor
Horsepower
1/61/61/61/6
F.L. Amps
1.11.11.11.0
Liquid Line, Inches O.D.*
3/8"3/8"3/8"3/8"
Suction Line, Inches O.D.*
3/4"7/8"1-1/8"1-1/8"
Refrigerant Charge
160.0190.0285.0280.0
Power Supply
208/230-60-1208/230-60-1208/230-60-1208/230-60-1
Minimum Circuit Ampacity
(1)
17.918.725.733.0
Maximum Overcurrent Device
(2)
30304050
Electrical Conduit Size
Power Supply (Inches)
1/2 or 3/41/2 or 3/41/2 or 3/41/2 or 3/4
Approximate Shipping Weight
282282282296
SSZ160241A* -SSZ160601A*
*
Up to 24' in equivalent line length
(1)
Wire size should be determined in accordance with National Electrical Codes; extensive wire runs will require larger wire sizes.
(2)
Maximum Overcurrent Protection Device: MUST use Time Delay Fuse or HACR type Circuit Breaker of the same size as noted.
NOTES:
•Always check the S & R plate for electrical data on the unit being installed.
•Installer will need to supply 7/8" to 1-1/8" adapters for suction line connections (4 & 5 ton units).
•Installer will need to supply 3/4" to 7/8" adapters for suction line connections (3 ton unit).
•Unit is charged with refrigerant for 15' of 3/8" liquid line. System charge must be adjusted per Installation Instructions Final Charge
Procedure.
•Installation of these units requires the specified TXV Kit to be installed on the indoor coil. THE SPECIFIED TXV IS DETERMINED BY THE
OUTDOOR UNIT, NOT THE INDOOR COIL.
NOTE: This data is provided as a guide, it is important to electrically connect the unit and properly size fuses/circuit breakers and
wires in accordance with all national and/or local electrical codes. Use copper wire only.
Unit specifications are subject to change without notice. ALWAYS refer to the unit's serial plate for the most up-to-date general
and electrical information.
HI PR395379364348340334321308295282270264259249240230222214
LO PR13312411610610197897971645652504337312721
High pressure is m easured at the liquid s ervice valve (the smaller val ve).AMPS = Outdoor unit amps (comp. +fan)
Low pressure is meas ured at the gauge port c onnection.
Calculations are based on nominal CF M and 70 °F indoor dry bul b.
*Note: Shaded area is ARI Rating Conditions at 47° outdoor ambient temberature
*To obtain BTU capacity of unit with KW of auxiliary heat, multiply by 1000 (Example: 39.01 x 1000 = 39,010 BTU)
PERFORMANCE DA TA
PERFORMANCE TEST
All data based upon listed indoor dry bulb temperature. .00 inches external static pressure on coil of outdoor section. Indoor
air cubic feet per minute (CFM) as listed in the Performance Data Sheets:
If conditions vary from this, results will change as follows:
1. As indoor dry bulb temperatures increase, a slight increase will occur in indoor air temperature drop (Delta T). Low
and high side pressures and power will not change.
2. As indoor CFM decreases, a slight increase will occur in indoor temperature drop (Delta T). A slight decrease will
occur in low and high side pressures and power.
A properly operating unit should be within plus or minus 2 degrees of the subcooling value shown in the Heat Pump
Specifications.
A properly operating unit should be within plus or minus 3 degrees of the typical (Delta T) value shown.
A properly operating unit should be within plus or minus 7 PSIG of the HI PR shown.
A properly operating unit should be within plus or minus 3 PSIG of the LO PR shown.
A properly operating unit should be within plus or minus 3 Amps of the typical value shown.
NOTE: Pressures are measured at the liquid and suction service valve ports.
17
WIRING DIAGRAMS
WARNING
L2
C
T2
SSZ160[24-48]1A*
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
C
SC
CH
1
2
SR
SEE RATING PLAT E
5
OUTDOOR POWER SUPPL Y
T1
C
L1
RCCF
S
COMP
X
U
A
IO
C
SA
F
A
M
(IF USED)
N
I
X
A
U
A
M
R
N
I
IO
DF2
DF1
CH
CM
(IF USED)
NOTE 3
HVDR
C
Y
DC
DFT
DFT
LVD R
R
POLE CO NTACTOR ONLY
ALTERNATE DOUBLE
C
RVC
LPS
HPS
Y
SUPPLY
W2
ORO
W2
INDOO R POW ER
O
R
TERMINAL BLOCK & INDOOR
THERMOSTAT.
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
USE N.E.C. CLASS 2 WIRE
2) START A SSIST FACTORY
EQU IPPED WH EN REQU IRED.
FACTORY OR FIELD INSTALLED.
3) CRANKCASE HEATER MAY BE
NOTE 1
W2
OYC
R
LVJB
OR
WH
BL
BL/PK
--------- RUN CAPACITOR FOR COMPRESSOR & FAN
--- ------- LOW VOLT AGE JUNCTION BOX
WH -------------- WHITE
YL --------------- YELLOW
COLOR CODE
BK --------------- BLACK
BL/PK ---------- BLUE/PINK STRIPE
BR --------------- BROWN
OR --------------- ORANGE
BK
BK
DF1
DF2
HVD
R
DFT
DC
LVDR
R R
W2
O O
C Y
YL/PK--------- YELLOW/PINK STRIPE
PU --------------- PURPLE
RD --------------- RED
BL/PK
RD
RD
RD
WH
OR
YLBK
BL
WIRING CODE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAG E
FIELD WIRING
HIGH VOLTAGE
LOW VOLTAGE
RDBL
SC
RD
YL/PK
RD
BK
BK
BK
BK
BL
C
RD
L2
T2
BK BK
T1
L1
YL/PK
BL
YL
BL
1
SR
BK
5
2
COMPONENT CODE
C --------------- CONTACTOR
CH --- ------ ---- CRANKCASE HEATE R
CM ------------ OUTDOOR FAN MOTOR
COMP -------- COMPRESSOR
DC ---- ------ --- DEFROST CONTROL
DFT ------ ----- DEFROST THERMOSTAT
YL
YL
YL
YL
F
RCCF
HERM
C
RD
YL
BR
RD
PU
RD
SA
(IF USED)
NOTE 2
L2
T2
L1
T1
ALTERNATE DOUBLE
------------ LOW PRESSURE SWITCH
HPS------- ------HIGH PRESSURE SWI TCH
HVDR --- ----- HIGH V OLTA GE D EFROST REL AY
IO -------------- INTERNAL OVERLOAD
LPS
LVDR --- ------ LOW V OLTAGE DEFROST RELAY
LVJB
USE COPPER
EQUIPMENT GROUND
BK
RVC
BK
AUX
MAIN
COMP
BK
RD
BL/PK
HPS
POLE CONTACTOR
BL/PK
RCCF
CONDUCTORS ONLY
DFT
RD
--- ------- --- START CAPACITOR FOR COMPRESSOR (OPTI ONAL)SR ----- ------ -- S TART RELAY FOR COMPRESSOR (OPTIONAL)
SA ------------- START ASSIST
SC
RVC -- ------ --- REVERSING VALVE COIL
YL/PK
LPS
RD
YL
YL/PK
S
R
C
BR
PU
AUX
MAIN
IO
: GOODMAN PRINT SHOP 01/06 0140R00029P
VENDOR
CONTROLS SH OWN WITH THERM OSTAT IN 'OFF' PO SITION.
BK
CH
(IF USED) NOTE 3
BK
BK
CM
RD
CONTROL BOX
18
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
WIRING DIAGRAMS
WARNING
L2
C
T2
SC
CH
RCCF
1
2
SR
SEE RATING PLATE
5
OUTDOOR POWER SUPPLY
T1
C
L1
NOTE 1
LVJB
R
RD
W2
WH
OYC
ORPUBL
Y2
YL
4
BK
DF2
HVD
CONTROL BOX
DC
LVDR
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
F
R
S
COMP
X
N
I
U
A
A
M
IO
C
HDVR
DF2
DF1
BL/PK ---------- BLUE/PINK STRIPE
COLOR CODE
BK --------------- BLACK
CMR
5
3
2
1
BL
BL/PK
BK
DF1
R
DFT
R
RD
R
W2
O
O
OR
C Y
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
3
C
SA
(IF USED)
N
I
X
A
U
A
M
IO
(HIGH)
2
POLE CONTACTOR ONLY
ALTERNATE DOUBLE
CH
CM
(IF USED)
)
W
O
CMR
NOTE 3
L
(
5
4
CMR
C
Y
DC
DFT
W2
DFT
LVDR
R
C
RVC
RVC
1
LPS
LPS
HPS
HPS
ORO
O
O
C
C
CS
CS
Y2
R
R
IRING
PU --------------- PURPLE
RD --------------- RED
WH -------------- WHITE
BR --------------- BROWN
OR --------------- ORANGE
BK
BL/PK
RD
RD
WH
BK
PU
BL
WIRING CODE
YL --------------- YELLOW
YL/PK--------- YELLOW/PINK STRIPE
FACTORY WIRING
HIGH VOLTAGE
LOW VOLTAGE
OPTIONAL HIGH VOLTAGE
HIGH VOLTAGE
LOW VOLTAGE
FIELD W
BL
RD
SC
RD
RD
RD
T2
BK
BK
T1
BK
BL
BL
BL
BK
BK
SR
BK
RD
RD
C
L2
BK BK
L1
YL/PK
BL
PU
RD
BL
1
YL
5
2
COMPONENT CODE
YL
YL
YL
YL
F
HERM
C
BR
RD
PU
C --------------- CONTACTOR
RCCF
T2
T1
CM ------------ OUTDOOR FAN MOTOR
CH ------------- CRANKCASE HEATER
SA
L2
L1
CMR ---------- CONDENSER MOTOR RELAY
(IF USED)
COMP -------- COMPRESSOR
NOTE 2
ALTERNATE
SSZ160[60]1AA
C
C
0140R00064
DFT
Y
Y
W2
W2
O
O
INDOOR POWER
NOTES:
THERMOSTAT.
2) START ASSIST FACTORY
1) TO INDOOR UNIT LOW VOLTAGE
SUPPLY
Y2
TERMINAL BLOCK & INDOOR
JUNCTION BOX
---------- LOW VOLTAGE
------------ LOW PRESSURE SWITCH
DC ------------- DEFROST CONTROL
CS ------------- COMPRESSOR SOLENOID
RD
DFT ----------- DEFROST THERMOSTAT
DT ------------- DISCHARGE THERMOSTAT
HPS-------------HIGH PRESSURE SWITCH
HVDR -------- HIGH VOLTAGE DEFROST RELAY
IO -------------- INTERNAL OVERLOAD
LPS
LVDR --------- LOW VOLTAGE DEFROST RELAY
LVJB
USE COPPER
CONDUCTORS ONLY
EQUIPMENT GROUND
BK
COMP
C
MAIN
BL/PK
HPS
BL/PK
DFT
RD
RD
Y2
CS
AUX
BK
YL
RD
RVC
BK
CONTACTOR
DOUBLE POLE
EQUIPPED WHEN REQUIRED.
MAIN
BK
DT
3) CRANKCASE HEATER MAY BE
--------- RUN CAPACITOR FOR COMPRESSOR & FAN
RCCF
S
C
PU
USE N.E.C. CLASS 2 WIRE
FACTORY OR FIELD INSTALLED.
START RELAY FOR COMPRESSOR (OPTIONAL)
------------- START CAPACITOR FOR COMPRESSOR (OPTIONAL)
-------------
R
RVC ----------- REVERSING VALVE COIL
SC
SA ------------- START ASSIST
S
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
BK
YL/PK
YL/PK
LPS
BK
R
CH
(IF USED) NOTE 3
BK
BR
AUX
RD
BK
(HIGH)
(LOW)
CM
IO
19
WIRING DIAGRAMS
WARNING
L2
C
T2
SC
CH
RCCF
1
2
SR
SEE RATING PLATE
5
OUTDOOR POWER SUPPLY
T1
C
L1
NOTE 1
LVJB
OYC
R
W2
F
R
S
COMP
X
N
I
U
A
A
M
IO
C
HDVR
DF2
DF1
SSZ160[60]1AB/AC
HIGH VOLTAGE!
DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS
UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO
DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.
C
C
3
C
SA
(IF USED)
N
I
X
A
U
A
M
IO
(HIGH)
2
POLE CONTACTOR ONLY
ALTERNATE D OUBLE
CH
CM
(IF USED)
)
W
O
CMR
NOTE 3
L
(
5
4
CMR
C
Y
DC
DFT
W2
DFT
LVD R
R
C
RVC
RVC
1
LPS
LPS
ORO
O
O
DFT
HPS
HPS
W2
W2
O
O
Y
C
CS
CS
Y2 C
R
R
0140R00114 Rev. A
USE N.E.C. CLASS 2 WIRE
NOTES:
1) TO INDOOR UNIT LOW VOLTAGE
TERMINAL BLOCK & INDOOR
THERMOSTAT.
2) START ASSIST FACTORY
EQUIPPED WHEN REQUIRED.
3) CRANKCASE HEATER MAY BE
SUPPLY
FACTORY OR FIELD INSTALLED.
INDOOR POWER
Y2
20
YLY2
ORPUBL
RD
WH
COLOR CODE
BK --- ------- ----- BL ACK
BL/P K -- ---- ---- BL UE/ PINK ST RIPE
BR - ------- ------ - BR OWN
OR - ------ -------- ORANG E
PU - ------- ------ - PUR PL E
RD -- ------------- RED
WH -------------- WHITE
CMR
5
4
2
13
BL/PK
BK
BK
DF1
DF2
HVD
R
DFT
CONTROL BOX
DC
LVDR
R R
W2
O O
C Y
BK
BL/PK
BL
RD
RD
RD
WH
BK
OR
PU
BL
WIRING CODE
YL ---- ---- ------- Y ELLOW
YL/PK--------- YELLOW/PINK STRIPE
FAC TO RY WIRING
RDBL
SC
RD
RD
T2
BK
BK
BK
BL
BL
BL
BK
IRING
HIGH VOLTAGE
LOW V OLTAGE
OPTIONAL HIGH VOLTAGE
FIELD W
HIGH VOLTAGE
LOW V OLTAGE
RD
RD
L2
T1
L1
PU
BK
SR
BK
RD
C
BK BK
BL
RD
BL
1
YL
5
2
COMPONENT CODE
C ----- -------- -- CONTACTO R
CH ------------- CRANKCASE HEATER
CM ------------ OUTDOOR FAN MOTOR
CMR ------ ---- C ONDE NSER M OTOR RELAY
COMP -------- COMPRESSOR
CS ------------- COMPR ESSOR SOLENOID
DC ----- -------- DEFR OST CON TROL
DFT -- -------- - DEF ROST T HERMOS TAT
DT ---- ------- -- DIS CHAR GE T HER MOSTAT
HPS-- -----------HI GH PRESSURE SWIT CH
HVDR -------- HIG H VOLTAGE DEF ROS T RELAY
IO --- -------- --- IN TER NAL O VERLOAD
LPS ------- ----- LO W PRESSU RE SWIT CH
LVDR ----- ---- L OW V OLTAG E DE FROS T RELAY
YL
YL
YL
YL
F
RCCF
HERM
C
BR
RD
PU
T2
T1
RD
SA
(IF U SED)
NOTE 2
L2
L1
ALTERNATE
CONTACTOR
DOUBL E POLE
USE COPPER
CONDUCTORS ONLY
EQUIPMENT GROUND
BK
RVC
BK
DFT
RD
RD
C
Y2
CS
AUX
MAIN
COMP
BK
YL
RD
BL/PK
HPS
BL/P K
Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
LVJB ---------- LOW VO LTAGE JUNCTIO N BO X
RCCF --------- RUN CAPACI TOR FOR C OMPRESSOR & FAN
RVC - ------ ---- REVE RSIN G VALVE COI L
SA ----- ------ -- S TART ASSIST
SC --------- ---- START CAPACITOR FOR COMP RESS OR (O PTIO NAL)
SR ----- ------- - START RE LAY FOR CO MPRESSOR (O PT IONAL)
CONTROLS SHOWN WITH THERMOSTAT IN 'OFF' POSITION.
DT
BK
MAIN
BK
YL/PK
YL/PK
LPS
S
C
PU
BK
R
CH
(IF USED) NOTE 3
BK
BR
AUX
RD
BK
(HIGH)
(LOW)
CM
IO
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.