This manual is to be used by qualified, professionally trained HVAC technicians only. The
manufacturer does not assume any responsibility for property damage or personal injury due to
improper service procedures or services performed by an unqualified person.
Pride and workmanship go into every product to provide our customers with quality products. It is possible, however, that during its
lifetime a product may require service. Products should be serviced only by a qualified service technician who is familiar with the
safety procedures required in the repair and who is equipped with the proper tools, parts, testing instruments and the appropriate
service manual. REVIEW ALL SERVICE INFORMATION IN THE APPROPRIATE SERVICE MANUAL BEFORE BEGINNING REPAIRS.
IMPORTANT NOTICES FOR CONSUMERS AND SERVICERS
RECOGNIZE SAFETY SYMBOLS, WORDS AND LABELS
T
HIS UNIT SHOULD NOT BE CONNECTED TO. OR USED IN
CONJUNCTION WITH, ANY DEVICES THAT ARE NOT DESIGN CERTIFIED
FOR USE WITH THIS UNIT OR
NOT BEEN TESTED AND APPROVED BY THE MANUFACTURER
HAVE
ERIOUS PROPERTY DAMAGE OR PERSONAL INJURY, REDUCED UNIT
S
PERFORMANCE
AND/OR HAZARDOUS CONDITIONS MAY RESULT FROM THE USE OF
DEVICES THAT HAVE NOT BEEN APPROVED OR CERTIFIED BY THE
MANUFACTURER
.
.
HIGH VOLTAGE
D
ISCONNECT
UNIT
F
AILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY
OR DEATH
ALL
POWER BEFORE SERVICING OR INSTALLING THIS
. M
ULTIPLE POWER SOURCE S MAY BE PRESENT
.
.
O
TO
PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH
DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER
FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLICANCE
NLY PERSONNEL THAT HAVE BEEN TRAINED TO INSTALL, ADJUST, SERVICE OR
REPAIR (HEREINAFTER
,
.
MANUAL SHOULD SERVICE THE EQUIPMENT
BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM
IMPROPER SERVICE OR SERVICE PROCEDURES
ASSUME RESPONSIBILITY FOR ANY INJURY OR PROPERTY DAMAGE WHICH MAY
RESULT
. IN
LICENSES TO SERVICE THE EQUIPMENT SPECIFIED IN THIS MANUAL, ONLY
LICENSED PERSONNEL SHOULD SERVICE THE EQUIPMENT
INSTALLATION, ADJUSTMENT, SERVICING OR REPAIR OF THE EQUIPMENT
SPECIFIED IN THIS MANUAL, OR ATTEMPTING TO INSTALL, ADJUST, SERVICE OR
REPAIR THE EQUIPMENT SPECIFIED IN THIS MANUAL WITHOUT PROPER
TRAINING MAY RESULT IN PRODUCT DAMAGE, PROPERTY DAMAGE, PERSONAL
INJURY OR DEATH
, “
SERVICE
”)
THE EQUIPMENT SPECIFIED IN THIS
. THE
MANUFACTURER WILL NOT
. IF
YOU SERVICE THIS UNIT, YOU
ADDITION, IN JURISDICTIONS THAT REQUIRE ONE OR MORE
. I
MPROPER
.
To locate an authorized servicer, please consult your telephone book or the dealer from whom you purchased this product.
For further assistance, please contact:
CONSUMER INFORMATION LINE
GOODMAN® BRAND PRODUCTS
TOLL FREE
1-877-254-4729 (U.S. only)
email us at: customerservice@goodmanmfg.com
fax us at: (713) 856-1821
(Not a technical assistance line for dealers.)
email us at: customerservice@goodmanmfg.com
AMANA® BRAND PRODUCTS
TOLL FREE
1-877-254-4729 (U.S. only)
fax us at: (713) 856-1821
(Not a technical assistance line for dealers.)
(Not a technical assistance line for dealers.) Your telephone company will bill you for the call.
is a registered trademark of Maytag Corporation or its related companies and is used under license. All rights reserved.
2
Outside the U.S., call 1-713-861-2500.
IMPORTANT INFORMATION
SAFE REFRIGERANT HANDLING
While these items will not cover every conceivable situation, they should serve as a useful guide.
R
EFRIGERANTS ARE HEAVI ER THAN AIR
YOUR LUNGS OR IN ANY ENCLOSED SPACE
BREATHI NG OR DEATH
EVER PURGE REFRIGE RANT INTO AN ENCLOSED ROOM OR SPACE
• N
ALL REFRIGE RANTS MUST BE RECLA IMED
F AN INDOOR LEAK IS SUSPECTED, THOROUGHLY VENTILATE THE ARA
• I
BEFORE BEGINNING WORK
IQUID REFRIGERANT CAN BE VERY COLD
• L
BLINDNESS, AVOID CONTACT WITH REFRIGERANT AND WAR GLOVES AND
GOGGL ES
. IF
MEDICAL HELP IMMEDIATELY
• A
LWAYS FOLLOW
POISONOUS GAS WILL BE PRODUCED
:
LIQUID REFRIGERANT DOES CONTACT YOUR SKIN OR EYES, SEEK
EPA
REGULATIONS
. T
HEY CAN “PUSH OUT” THE OXYGEN IN
. TO
AVOID POSSIBLE DIFFICULTY IN
. BY
.
.
. TO
AVOI D POSSIBLE FROSTBITE OR
LAW
,
TO
AVOID POSSIBLE EXPLOSION
EVER APPLY FLAME OR STEAM TO A REFRIGERANT CYLIN DER
• N
HEAT A CYLIN DER FOR FASTER CHARGIN G, PARTIALLY IMMERSE IT IN WARM
WATER
.
EVER FILL A CYLIN DER MORE THAN
• N
EVER ADD ANYTHING OTHER THAN
• N
TO AN
410A
LISTED OR CERTIFIED FOR THE TYPE OF REFRIGERANT USED
• S
TORE CYLIN DERS IN A COOL, DRY PLACE
PLATFORM OR A ROLLER
R-410A
:
CYLINDER
.
. THE
.
. N
EVER BURN REFRIGERANT, AS
.
TO
AVOID POSSIBLE EXPLOSION, USE ONLY RETU RNABL E (NOT DISPOSABLE
SERVICE CYLINDERS WHEN REMOVING REFRIGE RANT FROM A SYSTEM
• E
NSURE THE CYLINDER IS FREE OF DAMAGE WHICH COULD LEAD TO A
LEAK OR EXPLOSION
• E
NSURE THE HYDROSTATIC TEST DATE DOES NOT EXCEED
• E
NSURE THE PRESSURE RATING MEETS OR EXCEEDS
.
. IF
YOU MUST
80%
FULL OF LIQUID REFRIGERANT
R-22 TO AN R-22
SERVICE EQUIPMENT USED MUST BE
CYLIN DER OR
.
. N
EVER USE A CYLIN DER AS A
.
5
YEARS
.
400 PSIG.
.
R-
)
THE U
NITED STATES ENVIRONMENTAL PROTECT ION AGENC Y
HAS ISSUED VARIOUS REGULATIONS REGARDING THE INTRODUCTION AND
OF
DISPOSAL
FOLLOW
LEAD
MAY
LOCAL
S
YSTEM CONTAMINA NTS, IMPROPER SERVICE PROCED URE AND/OR PHYSICAL
ABUSE AFFECTIN G HERMETIC COMPRESSOR ELECTRICAL TERMINALS MAY CAUSE
DANGEROUS SYSTEM VENTING
REFRIGE RANTS INTRODUCED INTO THIS UNIT
THESE REGULATIONS MAY HARM THE ENVIRONMENT AND CAN
TO
THEH IMPOSITION OF SUBSTANTIAL FINES
VARY BY JURISDICTION
EPA
OFFICE
. S
HOULD QUESTIONS ARISE, CONTACT YOUR
.
. T
.
("EPA")
. F
AILURE TO
HESE REGULA TIONS
The successful development of hermetically sealed refrigeration
compressors has completely sealed the compressor's moving
parts and electric motor inside a common housing, minimizing
refrigerant leaks and the hazards sometimes associated with
moving belts, pulleys or couplings.
Fundamental to the design of hermetic compressors is a method
whereby electrical current is transmitted to the compressor
motor through terminal conductors which pass through the
compressor housing wall. These terminals are sealed in a
dielectric material which insulates them from the housing and
maintains the pressure tight integrity of the hermetic compressor. The terminals and their dielectric embedment are strongly
constructed, but are vulnerable to careless compressor installation or maintenance procedures and equally vulnerable to
internal electrical short circuits caused by excessive system
contaminants.
HEN IN DOUBT, DO NOT USE CYLINDER
W
TO
AVOID POSSIBLE INJURY, EXPLOSION OR DEATH, PRACTICE SAFE
OF
HANDLING
REFRIG ERANTS
.
.
In either of these instances, an electrical short between the
terminal and the compressor housing may result in the loss of
integrity between the terminal and its dielectric embedment. This
loss may cause the terminals to be expelled, thereby venting the
vaporous and liquid contents of the compressor housing and
system.
A venting compressor terminal normally presents no danger to
anyone, providing the terminal protective cover is properly in
place.
If, however, the terminal protective cover is not properly in place,
a venting terminal may discharge a combination of
(a) hot lubricating oil and refrigerant
(b) flammable mixture (if system is contaminated
with air)
in a stream of spray which may be dangerous to anyone in the
vicinity. Death or serious bodily injury could occur.
Under no circumstances is a hermetic compressor to be electrically energized and/or operated without having the terminal
protective cover properly in place.
See Service Section S-17 for proper servicing.
3
PRODUCT IDENTIFICATION
AN Z 130181 AA
1234,56,7,8910,11
Brand
A -
Amana® brand
Type
N1 - 208/230V Single-Phase 60 Hz
Deluxe Split System
2 - 220/240V Single-Phase 50 Hz
Type3 - 208/230V Three-Phase 60 Hz
X:Condens er R-4 10A4 - 4 60V Three-Pha se 60 Hz
Z:Heat Pump R-410A5 - 380/415V Three-Phase 50 Hz
SEER
11 - 11 SEER
13 - 13 SEER
14 - 14 SEER
16 - 16 SEER
18 = 1-1/2 Tons
24 = 2 Tons
30 =
2-1/2 Tons
Major/Minor Revis ions
3-1/2 Tons
42 =
48 = 4 Tons
59 = 5 Tons
Engineering
Voltage
Nominal Capacity
36 = 3 Tons60 = 5 Tons
61 = 5 Tons
4
PRODUCT IDENTIFICATION
SS Z 141 AA
1234,5910,11
Brand
G
Goodman® brand
(Standard Feature Set)
S
Goodman® brand
(High Feature Set)
A
Amana® brand
Deluxe
D
Goodman® brand
Deluxe
V
Value Li ne
Type
S1 - 208/230V Single-Phase 60 Hz
Split System
Type3 - 208/230V Three-Phase 60 Hz
X:Condenser R-410A4 - 460V Three-Phase 60 Hz
Z:Heat Pump R-410A5 - 380/415V Three-Phase 50 Hz
036
6,7,8
Engineering
Maj or/Mi nor Revi si ons
Voltage
2 - 220/240V Single-Phase 50 Hz
SEER
13 - 13 SEER018 = 1-1/2 Tons042 = 3-1/2 Tons
14 - 14 SEER024 = 2 Tons048 = 4 Tons
16 - 16 SEER030 = 2-1/2 Tons059 = 5 Tons
18 - 18 SEER036 = 3 Tons060 = 5 Tons
038 = 3 Tons
5
PRODUCT IDENTIFICATION
A
=
CAP F1824A 6 A
12345,6,7,891 011,12
BrandEngineering*
CIndoor Coil
Unit Application2 = R-22
AUpfl ow/Downfl ow Coil
H Horizontal A-Coil
Horizontal Slab Coil
S
Coated Coils
T
Nominal Width for Gas Furnace
A = Fits 1 4" Furnace Cabinet
B = Fits 17-1/2" Furnace Cabinet
C =
Fits 21" Furnace Cabinet
D = Fits 24-1/2" Furnace Cabinet
N
Does Not Apply (Horizontal Slab Coils
Major/Minor Revisions
Refrigerant Charge
4 = R-410A
6 = R-410A or R-22
Cabinet Finish
U Unpai nted
PPainted
N Unpainted Cas e
Expansion Device
FFlowrator
T4 - 5 Tons
Expansi on Valve4 - 5 Tons
1824 =
3030 =
3131 =
3636 =
3642 =
3743 =
4860 = Factory-Installed Non-Adjustable
4961 =
Nominal Capacity @ 13 SEER
1-1/2 - 2 Tons
2-1/2 Tons
2-1/2 Tons
3 Tons
3 - 3-1/2 Tons
3 - 3-1/2 Tons
6
PRODUCT IDENTIFICATION
A
A
H
MBR800
1,2345,6789
Brand
MB - Modular Blower1: 208-230V/60Hz/1 P
TypeA: Fi rst Seri es
R -
Speed
E -
Vari able Speed
AirflowA: No Ci rcuit Breaker
8:
12:
16:
20:
800 CFM
1200 CFM
1500 CFM
2000 CFM
B:Ci rcuit Breaker
1
Elect rical
Design Se ries
Circuit Breaker
Factory Heat
00 No Heat
7
PRODUCT IDENTIFICATION
W
A
12345,6,7,891011 ,12
BrandEngineering*
A Airhandler
Unit ApplicationRefrigerant Charge
C Ceiling Mount PSC Motor4 = R-410a
DDownflow PSC Motor
Multi Position
EElectrical
Vari a bl e Sp eed
RMul ti Pos iti on PSC Motor
SMul ti Posi tion EEM Motor
TCoated Coils
W Wal l Mount PSC/EEM Motor
Cabinet Finish1830 = 1-1/2 - 3-1/2 Tons
U Unpainted3137 = 3 Tons
PPainted3642 = 3 - 3-1/2Tons
NUncased
Expansion Device
FFlowrator
TExpansion Valve1803 =1-1/2 Tons Cooling/3 kW Electric Heat
UF364216AA
Maj or/Mi nor Revisi ons
1 208/240V, 1 Phase, 60 Hz
Nominal Capacity
@ 13 SEER Dedicated Application
3636 = 3 Ton
Multi-Position & Downflow Application
Multi-Position & Downflow Application @10 SEER
1729 = 3 Ton
Ceing Mount & Wall Mount Applications
(Nominal Cooling Capacity/Electric Heat kW)
1805 =1-1/2 Tons Cooling/5 kW Electric Heat
2405 =2 Tons Cooling/5 kW Electric Heat
3608 =3 Tons Cooling/8 kW Electric Heat
3105 =1-1/2 - 2-1/2 Tons Cooling/5 kW Electric Heat
3210 =2 - 2-1/2 Tons Cooling/5 kW Electric Heat
3705 =3 Tons Cooling/5 kW Electric Heat
3708 =3 Tons Cooling/8 kW Electric Heat
3710 =3 Tons Cooling/10 kW Electric Heat
An "F" in the model number denotes a
Factory Installed Float Switch is present.
All Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-240v, 60 hz, 1 phase.
8
PRODUCT IDENTIFICATION
ARU F 18 B 14AA
123 4 5,6 7 8 910,11
BrandEngineering*
ASingl e-Pi ece
Ai rhandl er
Unit ApplicationRefrigerant Charge
C Ceiling Mount PSC Motor4 = R-410a
RMul ti Pos iti on PSC Motor
SMul ti Posi ti on EEM MotorElectrical
W Wall Mount PSC/EEM Motor1 208/240V, 1 Phase, 60 Hz
Maj or/Mi nor Revi si ons
Cabinet Finish
UUnpaintedB =
PPaintedC = 21" Wide
NUncasedD = 24 -1/2" Wide
Expansion Device
FFlowrator18 =
TExpansion Valve24 = 2 Tons47 =
1-1/2 Tons
25 = 2 Tons48 = 4 Tons
2-1/2 - 3 Tons
29 =
2-1/2 Tons
30 =
36 =3 Tons60 =5 Tons
2-1/2 - 3 Tons
37 =
Nominal Capacity @ 13SEER
Cabinet Width
1/2" Wide
17-
3-1/2 Tons
42 =
3-1/2 Tons
49 = 4 Tons
59 = 5 Tons
61 = 5 Tons
Airhandlers use DIRECT DRIVE MOTORS. Power supply is AC 208-230v, 60 hz, 1 phase.
9
PRODUCT IDENTIFICATION
A
A
GS X 11 0901AA
1234,56,7,8910,11
LIGHT COMMERCIAL
Brand
G - Goodman brand
A - Amana brand
Type
S1 - 208/230V Single-Phase 60 Hz
Split Sys tem
2 - 220/240V Single-Phase 50 Hz
Type3 - 208/230V Three-Phase 60 Hz
X:Condens er R-41 0A4 - 460V Three-Phase 60 Hz
Z:Heat Pump R-410A5 - 380/415V Three-Phase 50 Hz
SEER
11 - 11 SEER
13 - 13 SEER
14 - 14 SEER
16 - 16 SEER036 - 3 Tons
048 - 4 Tons
060 - 5 Tons
090 - 7-1/2 Tons
120 - 10 Tons
Maj or/Mi nor Revi si ons
Engineering
Voltage
Nominal Capacity
10
R090A
123,4,56,7
Brand
Single Piece
A
Ai r Handler
Unit Application
R090 7-1/2 Tons
Multi Position
PSC Motor
For use with GSX/GSZ11 Light Commercial models only.
Maj or/Mi nor Revisi ons
Engineering
Nominal Capacity
120 10 Tons
PRODUCT IDENTIFICATION
GSX11 LIGHT COMMERCIAL
LIGHT COMMERCIAL
OODMAN® BRAND SPLIT
G
Model/RevDescription
GSX11090*AA
GSX11120*AA
GSX111203AB
GSX110903AB
GSX111204AB
GSX110904AB
Introduction of Goodman Light Commercial 11 SEER, R-410A Condensers.
208-230V and 460V 3 Phase condensing units with new ball valve/brackets, suction
tube/assembly and panel w/offset.
R410A CONDENSERS 11 SEER
X-
GSZ11 LIGHT COMMERCIAL
OODMAN SPLIT Z-R410A HEAT PUMP 11 SEER
G
Model/RevDescription
GSZ11090*AA
GSZ11120*AA
GSZ110903AB
GSZ111203AB
GSZ110904AB
GSZ111204AB
Introduction of Goodman Light Commercial 11 SE ER, R-410A Heat Pumps.
208-230V and 460V 3 Phase R410A heat pump units with new ball valve/brack ets, suction
tube/assembly and panel w/offset.
AR LIGHT COMMERCIAL
SINGLE PIECE
A
Model/RevDescription
AR0904A
AR1204A
Introducation of new 7.5 & 10 Ton Air Handler Models, for use with GSX11 and GSZ11
Light Commercial Models.
MULTI-POSITION PSC MOTOR
R-
11
PRODUCT IDENTIFICATION
Split System Heat Pumps
ASZ13
MANA® BRAND SPLIT
A
Model/RevDescription
ASZ130**1AAInitial release of Amana® Brand 13 SEER Heat Pump R410A.
ASZ130**1ABIntroduces new revisions with improved circuiting for effective defrost.
ASZ130[18, 36-60]1AB
ASZ130[24-30]1AC
ASZ130[18, 36-60]1AC
ASZ130[24-30]1AD
ASZ130[18, 36-60]1AD
ASZ130[24-30]1AE
ASZ130241BARelease of 2 Ton models, converting from 3/8" to 5mm condenser coils
ASZ130181AF
ASZ130[24-30]1AG
ASZ130481AF
ASZ130361AG
ASZ130421AH
Introduces models c ontaining crankcas e heater, CCH s witch and upgraded defrost
control.
Relocation of low pressure switch from liquid line to suction line as a compressor
safeguard to prevent low pressure from entering.
Initial release of models using single speed PSC motors; removal of low ambient
temperature switch.
Current reversing valve change from Dunan to new SanHua reversing valve
Current Ranco reversing valve 0151M00020 replaced by SanHua 0151R00070 reversing
va lve
Change from copper wound motor to aluminum wound motor.
R410A HEAT PUMP 13 SEER
Z-
ASZ130481AG
ASZ130601AF
Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
12
PRODUCT IDENTIFICATION
Split System Heat Pumps
ASZ14
MANA® BRAND SPLIT
A
Model/RevDescription
ASZ140**1AA
ASZ140**1ABScrew locations moved in the top panel, base pans, louvers, and control box covers.
Models containing crankcase heater, CCH switch and upgraded defrost control.
Release of single phase models with new 6 pole motor.
Relocation of low pressure switch from liquid line to suction line as a compressor
safeguard to prevent low pressure from entering.
Release of 2 Ton models with a compressor change from ZP21K5EPFV130 to
ZP20K5EPFV130.
Changed from four-piece louver assembly to a two piece louver assembly. Added a corner
post on 26" and 29" chassis.
Single phase models with new 6 pole motor.
Changed from four-piece louver assembly to a two piece louver assembly. Added a corner
post on 26" and 29" chassis.
R410A HEAT PUMP 13 SEER
Z-
VSZ130421AFCompressor change from ZP36K5EPFV130 to ZP34K5EPFV130.
VSZ130241CB
VSZ130181AF
VSZ130241BD
VSZ130301AG
VSZ130481AFRanco 0151M00020 reversing valve replaced by SanHua 0151R00070 reversing valve
VSZ130241BECreate new Motor & Replace 0131M00294 with 0131M00800
VSZ130601ADCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
2 Ton models changing from the current four piece louver assembly, to a two piece louver
plus a corner post on Goodman and value series 26" and 29" chassis.
Reversing valve change from Dunan to new SanHua.
18
PRODUCT IDENTIFICATION
Split System Heat Pumps
VSZ14
ALUE SPLIT
V
Model/RevDescription
VSZ14[018-060]1AAIntroduction of ready 15, 14 SEER heat pumps to meet the 2015 efficiency requirement.
VSZ140(18-30)1ABEnergy guide update. PCBDM160 with new software.
R410A HEAT PUMP 14 SEER
Z-
VSZ140421AB
VSZ140491AB
VSZ140[181,301]AC
VSZ140[361,481,601]AB
VSZ140[181, 301]AD
VSZ140361AC
VSZ140[241, 421, 491]AC
VSZ140241AD
VSZ140[481,601]AC
Motor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.
Refrigerant charge reduction.
Change from copper wound motor to aluminum wound motor.
Refrigerant Charge Reduction
Equivalent motor wit h Aluminum Windings replacing Copper Windings.
Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
19
PRODUCT IDENTIFICATION
Split System Heat Pumps
GSZ13
OODMAN SPLIT
G
Model/RevDescription
GSZ13**1AAInitial release with Regal Beloit motor.
GSZ13**1AB
GSZ13**3AA
GSZ13**4AA
GSZ130[24 & 30]1ACRelease of minor revision with improved circuiting for effective defrost.
GSZ130[24 & 36]1BAInitial release of models with 5mm Smart Coil™.
Release of 2 Ton models with a compressor change from ZP21K5EPFV130 to
ZP20K5EPFV130.
2 Ton models changing from the current four piece louver assembly, to a two piece louver
plus a corner post on Goodman and value series 26" and 29" chassis .
Release of models containing crankcase heater, CCH switc h and upgraded defrost control.
Relocation of low press ure switch from liquid line to suction line as a compress or safeguard
to prevent low pressure from entering.
Changing from the current four piece louver ass embly , to a two piece louver plus a c orner
post on Goodman and value series 26" and 29" chassis.
R410A HEAT PUMP 13 SEER
Z-
GSZ130361BC
GSZ130[42 & 48]1AE
GSZ130361BD
GSZ130421AF
GSZ130[36 & 48]3ACRelease of 3 phase models with new 6 pole motor.
GSZ14**1AAInitial release of 14 SEER models.
GSZ130481AG
GSZ130483AE
GSZ130484AD
GSZ130[191,311] AD
GSZ130241BE
GSZ130251AC
GSZ130601AE Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
Releas e of models with new 6 pole motor/fan combination.
Models wit h new 6 pole motor/fan combination. Changing from the c urrent four piece louver
assembly, to a two piece louver plus a corner post on Goodman and value series 26" and
29" chassis.
Releas e of two piece louver plus corner post on 26" and 29" chassis with compressor
changing from ZP36K5EPFV130 to ZP34K5EPFV130.
Replac ed Ranco revers ing valve 0151M00020 with SanHua 0151R00070 reversing valve .
Create new Motor & Replace 0131M00294 with 0131M00800
20
PRODUCT IDENTIFICATION
GSZ14
OODMAN SPLIT
G
Model/RevDescription
GSZ140(18-60)1KA
GSZ140491AA
GSZ140(18-30)1KBEnergy guide update. PCBDM160 with new software.
Introduction of ready 15 14 SEER heat pumps to meet the 2015 energy efficiency
requirement .
R410A HEAT PUMP 14 SEER
Z-
Split System Heat Pumps
GSZ140301KC
GSZ140361KB
Migrating from copper to aluminum motors.
GSZ140[421,491]KB Motor ch ange on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Incre ase blade gap.
GSZ140181KC
GSZ140361KC
GSZ140[241,301]KD
GSZ140[481,601]KB
GSZ140[241, 301]KE
GSZ140[481, 601]KC
GSZ140181KD
GSZ140[421, 491]KC
GSZ140241KF
GSZ140371AB
Refrigerant charge re duction.
New mod el re visions, GSZ140241KD, GSZ140301KD, GSZ140481KB and GSZ140601KB
will have the BOMs changed and have a lower refrigerant charge.
New model revisions to deplete current overstock of Ranco reversing valves
Change from copper wound motor to aluminum wound motor.
Refrigerant Charge Reduction
Equivalent motor with Aluminum Windings replacing Copper Windings.
Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
GSZ140[481,601]KD
GSZ16
OODMAN SPLIT
G
R410A HEAT PUMP 16 SEER
Z-
Model/RevDescription
GSZ160[18-48]1BAInitial release of Goodman 16 S EER, 13 EER Heat Pumps with 9.0+ HSPF
GSZ1160601BAInitial release of Goodman 5 Ton 16 SEER, 13 EER Heat Pumps
GSZ160241BB
GSZ160301BB
GSZ160181BB 16 SEER 1.5T Heat Pumps, Remove Hard Start Kit
GSZ160181BC Equivalent motor with Aluminum W indings replacing Copper Windings.
GSZ160[361, 481]BC Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
Motor change on 3 & 3.5T 14 SEER & 2 & 2.5T 16 SEER. Increase blade gap.
Swit ching current Goodman 16SEER condensers and heat pumps with grille tops to louver
tops to be consistent with other Goodman units having louver-style top panels.
21
PRODUCT IDENTIFICATION
Split System Heat Pumps
SSZ14
PECIAL HIGH FEATUR E SPLIT
S
Model/RevDescription
SSZ140**1AAInitial release of Goodman 14 SEER Heat Pump R410A.
SSZ140**1ABScrew locations moved in the top panel, base pans, louvers, and control box covers.
Added discharge line mufflers. Replaced TXV and compensator with flowrator and
accumulator.
Sanhua (RANCO) reversing valves.
Introduction of heat pumps with accumulators, crankcase heaters, and upgraded defrost
control.
Changed from four-piece louver ass embly to a two piece louver assembly. Added a corner
post on Goodman 26" and 29" chassis.
Revision made for design improvement.
Relocation of low pressure switch from liquid line to suction line as a compressor
safeguard to prevent low pressure from entering.
Chassis size reduction from large to medium.
R410A HEAT PUMP 14 SEER
Z-
SSZ140381AAInitial release of 35" chassis with 6-channel flowrator and ZP29K5 compressor.
SSZ140[18-30]1BAUpdated ratings and agency information.
SSZ140241BB
SSZ140251AE
SSZ140361BE
SSZ140371AE
SSZ140[421,481,601]AK
22
Change from copper wound motor to aluminum wound motor.
Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
PRODUCT IDENTIFICATION
Split System Heat Pumps
SSZ16
PECIAL HIGH FEATURE SPLIT
S
Model/RevDescription
SSZ160**1AAInitial releas e of Goodman 16 SEER Heat Pump R410A.
SSZ160**1ABScrew locations moved in the top panel, base pans, louvers, and control box covers.
SSZ160**1AC
SSZ16[024-48]1AC
SSZ160601AD
SSZ160361AF
SSZ160[42-60]1AD
SSZ160241AF
SSZ160[36, 48]1AD
SSZ160601AE
SSZ160241AF
SSZ160[36-48]1AE
SSZ160601BA
SSZ160241AH
Broad Ocean Motor. Updated muffler and standardized TXV. Compensator using ASZ18
SEER weldment to the SSZ160601AC.
Discharge line mufflers added.
Added discharge line mufflers. Replaced TXV and compensator with flowrator and
accumulator.
Sanhua (RANCO) reversing valves.
Introduction of heat pumps with accumulators, crankcase heaters, and upgraded defrost
control.
Changed from four-piece louver assembly to a two piece louver assembly. Added a corner
post on Goodman 26" and 29" chassis.
R410A HEAT PUMP 16 SEER
Z-
SSZ160601BBUltratech® compressor
SSZ160241AKChange from copper wound motor to aluminum wound motor.
23
PRODUCT IDENTIFICATION
ging
Split System Condensers
GSX13
OODMAN BRAND SPLIT
G
Model/RevDescription
GSX130**1AAInitial release of Goodman 13 SEER R-410A Condensers with Regal Beloit motors
GSX13061[1/3/4]AA
GSX130363AB
GSX130484AB
GSX130603AB
GSX130604AB
GSX130**1ABBroad Ocean motors.
GSX130483AB3 Phase model with new 6 pole motor.
GSX130483AC
GSX130181EA
GSX130181EB
GSX130**1BA
GSX130**3AA
GSX130**4AA
GSX130301BBReplaced fan mot or to -294 and fan blade to -18 on GSX130301BA models.
GSX130[42, 48]1BC
GSX130301BC
GSX130601BB
GSX130[42, 48]1BBNew 6 pole motor/fan combination.
Introduction of Goodman 13 SEER R-410A Condensers that supplement our current 5 ton
models.
Changed from the current four piece louver assembly, to a two piece louver plus a corner
post on Goodman and value series 26" and 29" chassis.
3 phase model chan
plus a corner post on Goodman and value series 26" and 29" chassis.
Introduction of 1.5 ton condenser with Rechi Compressor.
Introduction of Goodman 13 SEER R-410A Condensers using SmartCoil® coils. Units will
have new louvers because units are smaller. Piston s ize c hange. Other components
unchanged.
Changed from the current four piece louver assembly, to a two piece louver plus a corner
post on Goodman and value series 26" and 29" chassis.
R410A CONDENSERS 13 SEER
X-
from the current four piece louver ass embly, to a two piece louver
GSX130181CARotary c ompressor.
GSX130421CA
GSX130481CA
GSX130361CAReplaced current compressor with compressor ZP29K5EPFV130.
GSX130[18-36]1DACondenser conversion to 23" chassis for the 1.5 - 3 ton models.
GSX130181ED
GSX13031DB
GSX130361EAIntroduction of Goodman 3 ton conversion from 29" chassis to 26".
GSX130361EB
GSX130371AAImproved decibel ratings for Canadian market.
GSX130181EF Change from motor 0131M00276 to 0131M00593 on units GSX130181 & VSX130181
GSX130363ADChange from copper wound motor to aluminum wound mot or.
GSX130241EC
GSX130301BF
Introduction of Goodman 3.5 and 4 ton 13 SEER condensing units wit h reciprocating
compressor.
Changed from a 4 leg Rechi Compressor 50N382XV-ZAKM to 3 Leg Rechi Compressor
50N382XV-5AKM. Changed Suction line Assy from 0210R01608 to 0210R01406. This
minor
Improved coil circuit assembly for greater capac ity/efficiency and a new discharge tubing
assembly.
Changed from the current four piece louver assembly, to a two piece louver plus a corner
post on Goodman and value series 26" and 29" chassis.
Create new Motor & Replace 0131M00294 with 0131M00800
*GSX13 CONTINUED ON THE NEXT PAGE
24
PRODUCT IDENTIFICATION
Split System Condensers
GSX13
OODMAN BRAND SPLIT
G
Model/RevDescription
GSX130611ACCreate new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
GSX130241ED
GSX130[301,601]B G
GSX130361EE
GSX130[421,481]B F
Fact ory Refrigerant Charge Optimization
R410A CONDENSERS 13 SEER
X-
25
PRODUCT IDENTIFICATION
GSX14
OODMAN BRAND SPLIT
G
Model/RevDescription
GSX14**1AAIntroduction of Goodman 14 SEER R-410A models.
GSX160[481,611]FF Create new Motor 0131M00807 & Replace 0131M00061 with 0131M00807
Ball Valve Re-work 0151R00045 & 0151R00046
Initial release creates and launches 2 new SKUs in the 16 SEER single-stage AC
product line.
Refrigerant charge reduction.
Equivalent motor with Aluminum Windings replacing Copper Windings.
Switching current Goodman 16SEER condensers and heat pumps with grille tops to
louver tops to be consistent with other Goodman units having louver-style top
panels.
27
PRODUCT IDENTIFICATION
Revisi
Split System Condensers
SSX14
PECIAL HIGH FEATURE SPLIT
S
Model/RevDescription
SSX140**1AAInitial release of Goodman 14 SEER AC 410A.
SSX140**1AB
SSX14018, 241ACRevised condenser coils by removing [1] haripin.
SSX140301ACModel contains the Broad Ocean motor 0131M00060
SSX14036-601ACModels contain the Broad Ocean motor 0131M00061
SSX14030,361ADRevised condenser coils by removing [1] haripin.
ons have screw locations moved in the top panel, base pans, louvers, and control
box covers.
Converts 1.5 - 3.5 ton condenser coil tubes from 3/8" tube diameter to 5mm tube
diameter.
Changing from the current four piece louver assembly, to a two piece louver plus a corner
post on Goodman and value series 26" and 29" c hassis.
Revision made for design improvement.
Revision for SSZ140421B* in 29 base pan and it will the reduce the unit charge from 180
oz. to 170 oz. and replace the 1/4 hp outdoor unit motor with 1/6 hp motor.
R410A CONDENSERS 14 SEER
X-
SSX14030-421AERevised condenser coils by removing [1] haripin.
SSX140[18-48]1BA
SSX14042-481CA
SSX140[18-36]1BB
SSX140421CB
SSX140601AF
Introduction of Goodman 14 SEER R-410A Condensers with SmartCoil® Coils.
Relocation of low pressure switch from liquid line to suction line as a compressor
safeguard to prevent low pressure from entering.
28
PRODUCT IDENTIFICATION
Split System Condensers
SSX16
PECIAL HIGH FEATURE SPLIT
S
Model/RevDescription
SSX160**1AAIntroduces Goodman 16 SEER AC 410A
SSX160**1AB
SSX160**1AB
SSX160591AA
SSX160[24, 36, 48]1BA
SSX160[30 & 42]1AA
SSX160[24, 36]1BC
SSX160[30, 42]1AB
SSX160601BAZPS49K compressor.
SSX160[24,36,60]1BB
New revisions have screw locations moved in the top panel, base pans, louvers, and
control box covers.
New revisions have screw locations moved in the top panel, base pans, louvers, and
control box covers.
SmartCoil® coils.
Changing from the current four piece louver assembly, to a two piece louver plus a corner
post on Goodman and value series 26" and 29" c hassis.
Relocation of low pressure switch from liquid line to suction line as a compressor
safeguard to prevent low pressure from entering.
R410A CONDENSER 16 SEER
X-
DSX16
ELUXE SPLIT
D
Model/RevDescription
DSX160**1AAInitial release of Goodman 2-stage, 16 SEER condensing units with R-410A.
R410A HEAT PUMP 16 SEER
X-
DSX160[24, 36]1BAConversion of 2 & 3 ton models to SmartCoil® Coils.