Daikin’s VRV IV systems integrate advanced technology to provide comfort control with maximum energy efficiency and relabilty. Currently available in heat pump configurations, VRV IV provides a solution for multi-family residential to large commercial applications desiring heating or cooling. The VRV IV is the first variable refrigerant flow (VRF) system to be be assembled in North America.
Features:
Total comfort solution for heating, cooling, ventilation and controls
Redesigned and optimized for total Life Cycle Cost (LCC)
Efficiency improved over VRV III by an average of 11% with IEER Values now up to 28
Improved seasonal efficiency as compared to VRV III with automatic and customizable Variable Refrigerant Temperature (VRT) climate tuning
Best-In-class warranty* with 10 year compressor and parts limited warranty as standard
Reduced commissioning time vs. VRV III with VRV configurator software and Graphical User Interface (GUI)
Design flexibility with long piping lengths up to 3,280 ft. total and 100 ft. vertical separation between indoor units
Take advantage of Daikin’s unique zone and centralized controls
Additional information
Before purchasing this appliance, re ad important inf ormation about its estimated annual energy consumption, yearly operating cost, or energy efficiency rating that is available from your retailer.
FIND OUT MORE ABOUT DAIKIN VRV.
*Complete warranty details available from your local distributor or manufacturer’s representative.
COMMERCIAL RENOVATION NEW CONSTRUCTION
VRV IV Operation
Lower capac ity is required to cool and heat a building during mid season
Adapting to re quired heat load by variable refrigerant volume
A VRV system adapts to the requir ed changes in capacit y by var ying the
refrigerant volume. This results in an increase in efficiency at part load op eration
The ef ficiency of VRV IV is fur ther increased by adjusting the re frigerant
temperature dependant on the space load and weather conditions
Variable Rt*
Fixed R t*
*Refrigerant
Temperature (Rt)
Design
Condition
Ambient Temperature
Cooling Requirement
Load
Ambient Temperature
Variable Rt*
Up to +28% Seasonal Cooling Efficiency vs. VRV III
The abo ve graphs are intended only to depic t how ad vantages of t he new Daikin VRV IV system combine to achieve the st ated increase in se asonal efficiency. The graphs do not reflec t test results, are not to sc ale and there fore do not quantif y the effec t of any such advantage.
Fixed R t*
Efficiency
Ambient Temperature
Outdoor Units - R XYQ_TTJU/ TYDN Heat Pump 6 Ton 8 Ton 10 To n 12 To n 14 Ton
Model
Performance
Fan Airflow cfm 5,544 5,827 6286 8,228 8,228
Refrigerant Piping
Model
Performance
Fan
Refrigerant Piping
Unit
Model
Performance
Fan Airflow cfm 8228 + 8228 8228 + 8228 6286 + 6286 + 6286 5827 + 6286 + 8228 6286 + 6286 + 8228
Refrigerant Piping
Unit Dimensions (H x W x D) in. (66-3/4 x 48-7/8 x 30-1/8) x2 (66-3/4 x 48-7/8 x 30-1/8) x 3 For all equipment installation and application limitations please refer to the specific Engineering Data Books.
Name 208-230V/3Ph/60Hz RXYQ72TTJU RXYQ96TTJU RXYQ120TTJU RXYQ144TTJU RXYQ168TTJU
Name 460V/3Ph/60Hz RXYQ72TYDN RXYQ96TYDN RXYQ120TYDN RXYQ144TYDN RXYQ168TYDN
Rated Cooling Capacity Btu/h 69,000 92,000 114,000 138,000 160,000
Rated Heating Capacity Btu/h 77,000 103,000 129,000 154,000 180,000
Operation Range - Cooling °F DB 23-122 23-122 23-122 23-122 23-122
Operation Range - Heating °F WB -4 - 60 -4 - 60 -4 - 60 -4 - 60 -4 - 60
Sound Pressure dB(A) 58 61 61 64 65
IEER (Ducted / Non-Ducted) 22.8 / 26.5 22.7 / 28 21.4 / 23.5 21 / 24.1 19.8 / 22.1
Vertical Pipe Length Above ft. 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting)
Vertical Pipe Length Below ft. 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) 130 (295 w/outdoor setting)
Vertical Pipe Length Between IDU ft. 100 100 100 100 100
Actual Pipe Length ft. 540 540 540 540 540
Equivalent Pipe Length ft. 620 620 620 620 620
Total Pipe Length ft. 3,280 3,280 3,280 3,280 3,280 Dimensions (H x W x D) in. 66-3/4 x 36-5/8 x 30-1/8 66-3/4 x 48-7/8 x 30-1/8
Name 208-230V/3Ph/60Hz RXYQ192TTJU RXYQ216TTJU RXYQ240TTJU RXYQ264TTJU RXYQ288TTJU Name 460V/3Ph/60Hz RXYQ192TYDN RXYQ216TYDN RXYQ240TYDN RXYQ264TYDN RXYQ288TYDN
Combination
Rated Cooling Capacity Btu/h 184,000 206,000 228,000 251,000 274,000 Rated Heating Capacity Btu/h 206,000 231,000 257,000 283,000 308,000 Operation Range - Cooling °F DB 23-122 23-122 23-122 23-122 23-122 Operation Range - Heating °F WB -4 - 60 -4 - 60 -4 - 60 -4 - 60 -4 - 60 Sound Pressure dB(A) 63 64 64 66 67 IEER (Ducted/Non-Ducted) 20.7 / 22.2 20 / 20.5 18.4 / 20.8 19.3 / 20.3 19.3 / 20.1 Airflow cfm 5544 + 6286 5827 + 6286 6286 + 6286 6286 + 8228 8228 + 8228 Vertical Pipe Length Above ft. 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting)
Vertical Pipe Length Below ft. 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) Vertical Pipe Length Between IDU ft. 100 100 100 100 100 Actual Pipe Length ft. 540 540 540 540 540 Equivalent Pipe Length ft. 620 620 620 620 620 Total Pipe Length ft. 3,280 3,280 3,280 3,280 3,280
Dimensions (H x W x D) in.
Name 208-230V/3Ph/60Hz RXYQ312TTJU RXYQ336TTJU RXYQ360TTJU RXYQ384TTJU RXYQ408TTJU Name 460V/3Ph/60Hz RXYQ312TYDN RXYQ336TYDN RXYQ360TYDN RXYQ384TYDN RXYQ408TYDN
Combination
Rated Cooling Capacity Btu/h 297,000 320,000 342,000 365,000 380,000 Rated Heating Capacity Btu/h 334,000 360,000 385,000 411,000 436,000 Operation Range - Cooling °F DB 23-122 23-122 23-122 23-122 23-122 Operation Range - Heating °F WB -4 - 60 -4 - 60 -4 - 60 -4 - 60 -4 - 60 Sound Pressure dB(A) 68 68 66 68 68 IEER (Ducted/Non-Ducted) 18.8 / 19.9 18.5 / 19.5 18.5 / 19.4 18.5 / 20.4 19.0 / 20.9
Vertical Pipe Length Above ft. 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting) 164 (295 w/outdoor setting)
Vertical Pipe Length Below ft. 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) 130 (295 w/outdoor setting) 130 (295/w/outdoor setting) 130 (295 w/outdoor setting)
Vertical Pipe Length Between IDU ft. 100 100 100 100 100 Actual Pipe Length ft. 540 540 540 540 540 Equivalent Pipe Length ft. 620 620 620 620 620 Total Pipe Length ft. 3,280 3,280 3,280 3,280 3,280
16 To n 18 To n 20 Ton 2 2 Ton 24 Ton
1 x RXYQ120T 1 x RXYQ120T 2 x RXYQ120T 1 x RXYQ144T 2 x RXYQ144T
1 x RXYQ72T 1 x RXYQ96T 1 x RXYQ120T
(66-3/4 x 48-7/8 x 30-1/8) +
(66-1/8 x 36-5/8 x 30-1/8)
26 Ton 28 Ton 3 0 Ton 3 2 Ton 34 Ton
1 x RXYQ168T 2 x RXYQ168T 3 x RXYQ120T 1 x RXYQ168T 1 x RXYQ168T
1 x RXYQ144T 1 x RXYQ96T 1 x RXYQ96T
(66-3/4 x 48-7/8 x 30-1/8) x2
1 x RXYQ120T 1 x RXYQ144T