Goodman GPH1324M41AB, GPH1330M41AB, GPH1336M41AB, GPH1342M41AB, GPH1348M41AB Installation Manual

...
A
I
NSTALLATION INSTRUCTIONS
F
OR
S
IR
C
ONDITIONERS
ELF
-C
ONTAINED
AND
H
P
EAT
ACKAGE
P
GPC/GPH 13 SEER “M” SERIES
UMP
U
NITS
W
ITH
R-410A
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION.
ATTENTION INSTALLING PERSONNEL
Prior to installation, thoroughly familiarize yourself with this Installation Manual. Observe all safety warnings. During
installation or repair, caution is to be observed.
It is your responsibility to install the product safely and to educate the customer on its safe use.
IO-395C 5/2012
Goodman Manufacturing Company, L.P.
5151 San Felipe, Suite 500, Houston, TX 77056
www.goodmanmfg.com www.amana-hac.com
© 2010-2012 Goodman Manufacturing Company, L.P.
is a registered trademark of Maytag Corporation or its related companies and is used under
license to Goodman Company, L.P., Houston, TX. All rights reserved.
*NOTE: Please contact your distributor or our
website for the applicable Specification Sheets
referred to in this manual.
INDEX
TO THE INSTALLER ................................................ 2
O THE OWNER ...................................................2
T
SHIPPING INSPECTION .......................................... 3
REPLACEMENT PARTS .......................................... 3
RDERING PARTS ..................................................3
O
SAFETY INSTRUCTIONS ........................................ 3
CODES AND REGULATIONS .................................. 3
EPA R
N
MAJOR COMPONENTS ..........................................4
PRE-INSTALLATION CHECKS ................................4
C
U
G
R
R
R
CIRCULATING AIR AND FILTERS ........................... 5
A
D
F
PIPING....................................................................... 6
C
WIRING ...................................................................... 7
H
L
I
STARTUP, ADJUSTMENTS, AND CHECKS ...........8
S
H
F
COMPONENTS ........................................................8
C
C
C
C
D
O
R
I
B
HEAT PUMP OPERATION .......................................9
C
H
D
S
A
S
R
EGULATIONS ................................................4
ATIONAL C ODES .................................................. 4
LEARANCES AND A CCESSIBILITY ..............................4
NIT LOCATION ...................................................... 4
ROUND LEVEL PRE-INSTALLATION DETAILS ...............4
OOF TOP PRE-INSTALLATION DETAILS ..................... 4
OOF CURB INSTALLATIONS ONLY ............................ 5
IGGING DETAILS ..................................................5
IRFLOW CONVERSION ...........................................5
UCT WORK .......................................................... 6
ILTERS ............................................................... 6
ONDENSATE DRAIN ...............................................6
IGH VOLTAGE WIRING ...........................................7
OW VOLTAGE WIRING ............................................7
NTERNAL WIRING ...................................................7
TART-UP PROCEDURE AND CHECKLIST ..................... 8
EAT PUMP START-UP PROCEDURE ..........................8
INAL SYSTEM C HECKS ..........................................8
RANKCASE HEATER ..............................................8
ONDENSER MOTOR ..............................................9
OMPRESSOR .......................................................9
ONTACTOR RELAY ................................................9
EFROST CONTROL ................................................ 9
UTDOOR THERMOSTAT ..........................................9
EVERSING VALVE COIL ......................................... 9
NDOOR BLOWER MOTOR ........................................ 9
LOWER INTERLOCK RELAY .....................................9
OOLING CYCLE ................................................... 9
EATING C YCLE .................................................... 9
EFROST CONTROL .............................................. 10
UGGESTED FIELD TESTING/TROUBLE S HOOTING ...... 10
IRFLOW MEASUREMENT AND A DJUSTMENT ...............10
PEED TAP A DJUSTMENTS
FOR INDOOR BLOWER M OTOR ...........................12
EFRIGERANT CHARGE CHECKS ............................. 12
ELECTRICAL ADJUSTMENTS..............................12
MAINTENANCE ...................................................... 13
ERVICE ............................................................ 13
S
NADEQUATE AIR VOLUME T HROUGH I NDOOR COIL .....13
I
UTSIDE AIR INTO RETURN DUCT .......................... 13
O
NDERCHARGE ....................................................13
U
OOR “TERMINATING” SENSOR CONTACT ................ 13
P
ALFUNCTIONING REVERSING VALVE -
M
HIS MAY BE DUE TO: ....................................... 13
T
TROUBLESHOOTING CHART .............................14
APPENDIX ............................................................... 15
UNIT DIMENSIONS ................................................15
MINIMUM CLEARANCES ......................................16
RECOMMENDED FILTER SIZES ..........................16
WARNING
I
NSTALLATION AND REPAIR OF THIS UNIT SHOULD BE PERFORMED THE REQUIREMENTS OF AN SPECIFIED
R
EFRIGE RATION INSTITUT E INSTALL RESULT
ONLY BY
BY
THE AIR-CONDITIONING
OR
REPAIR THIS UNIT WITHOUT SUCH BACKGROUND MAY
IN
PRODUCT DAMAG E, PERSONAL INJURY OR DEATH
INDIVIDUALS MEETING
“E
NTRY LEVEL TECHNICIAN” AS
, H
(AHRI). A
EATING, AND
TTEMPTING TO
AT A MINIMUM
(
)
.
TO THE INSTALLER
Carefully read all instructions for the installation prior to installing unit. Make sure each step or procedure is understood and any special considerations are taken into account before starting in­stallation. Assemble all tools, hardware and supplies needed to complete the installation. Some items may need to be purchased locally. After deciding where to install unit, closely look the location over - both the inside and outside of home. Note any potential obstacles or problems that might be encountered as noted in this manual. Choose a more suitable location if necessary.
IMPORTANT NOTE: If a crankcase heater is used, the unit should be energized 24 hours prior to compressor start up to ensure crankcase heater has sufficiently warmed the compres­sor. Compressor damage may occur if this step is not fol­lowed.
IMPORTANT NOTE TO THE OWNER REGARDING PRODUCT WARRANTY
Your warranty certificate is supplied as a separate document with the unit installed by your contractor. Read the limited warranty certificate carefully to determine what is and is not covered and keep the warranty certificate in a safe place. If you are unable to locate the warranty certificate please contact your installing contractor or contact customer service (877­254-4729) to obtain a copy.
To receive the 10-year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec.
Complete warranty details available from your local dealer or, for Goodman® brand products, visit www.goodmanmfg.com, and for Amana® brand products, visit www.amana-hac.com.
2
IMPORTANT: To register your Goodman® brand unit, go to www.goodmanmfg.com and click “Warranty Registration”. Com­plete registration as prompted.
To register your Amana® brand unit, go to www.amana-hac.com and click “Warranty Registration”. Complete registration as prompted.
Product limited warranty certificates for models currently in pro­duction can be viewed at www.goodmanmfg.com or www.amana­hac.com. If your model is not currently in production or does not appear on the website, please contact your installing contractor or contact customer service (877-254-4729) to obtain a copy of your warranty certificate.
Each product overview page contains a Product Warranty link; by clicking on it you will be able to view the limited warranty coverage for that specific product. To view warranty registration information, click on the Product Warranty text on the left navigation panel on the home page of each website. The Online Product Registration pages are located in this same section.
Before using this manual, check the serial plate for proper model identification.
WARNING
DO NOT CONNECT TO OR USE ANY DEVICE THAT IS NOT DESIGN-CERTIFIED
BY
GOODMAN FOR USE WITH THIS UNIT. SERIOUS PROPERTY DAMAGE,
PERSONAL INJURY, REDUCED UNIT PERFORMANCE AND/
CONDITIONS MAY RESULT FROM THE USE OF SUCH NON-APPROVED DEVICES.
OR HAZARDOUS
WARNING
HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING
THIS UNIT.
TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR
DEATH.
MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE
WARNING
CONNECTING UNIT DUCT WORK TO UNAUTHORIZED HEAT PRODUCING DEVICES
SUCH AS A FIREPLACE INSERT, STOVE, ETC. MAY RESULT IN PROPERTY
DAMAGE, FIRE, CARBON MONOXIDE POISONING, EXPLOSION, PERSONAL
INJURY OR DEATH.
The installation and servicing of this equipment must be performed by qualified, experienced technicians only.
SHIPPING INSPECTION
Upon receiving the unit, inspect it for damage from shipment. Claims for damage, either shipping or concealed, should be filed immediately with the shipping company. Check the unit model number, specifications, electrical characteristics and accessories to determine if they are correct. In the event an incorrect unit is shipped, it must be returned to the supplier and must NOT be installed. The manufacturer assumes no responsibility for instal­lation of incorrectly shipped units.
REPLACEMENT PARTS
ORDERING P ARTS
When reporting shortages or damages, or ordering repair parts, give the complete unit model and serial numbers as stamped on the unit’s nameplate. Replacement parts for this appliance are available through your contractor or local distributor. For the location of your nearest distributor, consult the white business pages, the yellow page section of the local telephone book or contact:
CONSUMER AFFAIRS
GOODMAN MANUFACTURING COMPANY, L.P.
7401 SECURITY WAY
HOUSTON, TEXAS 77040
877-254-4729
WARNING
HIS PRODUCT CO NTAINS OR PRODUCES A CHEMICAL OR CHEMICALS WHICH
T
MAY CAUSE SERIOUS ILLNESS OR DEATH AND WHICH ARE KNOWN TO THE
S
TATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER
REPRODUCTIVE HARM.
WARNING
O AVOID PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, DO NOT USE
T
I
THIS UNIT IF ANY PART HAS BEEN UNDER WATER.
QUALIFIED SERVICE TECHNICIAN TO INSPECT THE FURNACE AND TO REPLACE
ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL HAVING BEEN
UNDER WATER.
MMEDIATELY CALL A
WARNING
TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH,
DO NOT STORE COMBUSTIBLE MATERIA LS OR USE GASOLINE OR OTHER
FLAMMABLE LIQUIDS OR VAPO RS IN TH E VICINITY OF THIS APPLIANCE.
SAFETY INSTRUCTIONS
The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and comply with all safety information and instructions accompanying these symbols. Fail­ure to heed safety information increases the risk of personal injury, property damage, and/or product damage.
CODES AND REGULATIONS
The GPC/GPH M-series air conditioners and heat pumps are de­signed for OUTDOOR USE ONLY. GPH M-Series is available in cooling capacities of 2, 2-1/2, 3, 3-1/2, 4 and 5 nominal tons of cooling. GPC M-Series is available in cooling capacities of 3, 4 and 5 nominal tons of cooling. Optional field installed heat kits are available in 5,8,10,15 and 20 kW. 3 phase heat kits are available only in 15 and 20 kW. The units can be easily installed in manufac­tured or modular homes with existing high-static duct work. The units can also be easily converted to accommodate a plenum for normal or low-static applications. The GPC/GPH M-series are self
3
contained packaged units so the only connections needed for installation are the supply and return ducts, the line and low voltage wiring and drain connection. Rated performance is achieved after 72 hours of operation. The units are ETL listed and AHRI certified.
The information on the rating plate is in compliance with the FTC & DOE rating for single phase units. The three phase units in this series are not covered under the DOE certified program. The efficiency ratings of these units are a product of thermal effi­ciency determined under continuous operating conditions inde­pendent of any installed system.
EPA REGULATIONS
IMPORTANT: THE U NITED STATES ENVIRONMENTAL PROTECTION AGENCY (EPA) HAS ISSUED VARIOUS REGULATIONS REGARDING
INTRODUCTION AND DISPOSAL OF REFRIGERANTS IN THIS UNIT.
THE
FAILURE TO FOLLOW THESE REGULATIONS MAY HARM THE
ENVIRONMENT
. BECAUSE REGULATIONS MAY VARY DUE TO PASSAGE OF
FINES
LAWS, WE SUGGEST A CERTIFIED TECHNICIAN PERFORM ANY
NEW
WORK
PLEASE
AND CAN LEAD TO THE IMPOSITION OF SUBSTANTIAL
DONE ON THIS UNIT. SHOULD YOU HAVE ANY QUESTIONS
CONTACT THE LOCAL OFFICE OF THE EPA.
NATIONAL CODES
This product is designed and manufactured to permit installation in accordance with National Codes. It is the installer’s responsi­bility to install the product in accordance with National Codes and/ or prevailing local codes and regulations.
Close to the wall application assures free, unobstructed air to the other two sides. In more confined application spaces, such as corners provide a minimum 10” clearance on all air inlet sides. Allow 18” minimum for service access to the compressor com­partment and controls. The top of the unit should be completely unobstructed. If units are to be located under an overhang, there should be a minimum of 36” clearance and provisions made to deflect the warm discharge air out from the overhang.
UNIT LOCATION
Consider the affect of outdoor fan noise on conditioned space and any adjacent occupied space. It is recommended that the unit be placed so that condenser air discharge does not blow toward windows less than 25 feet away. Consideration should also be given to shade and unit appearance. Heat pumps require special location consideration in areas of heavy snow accumulation and/or areas with prolonged continuous sub­freezing temperatures. Heat pump unit bases have holes under the outdoor coil to permit drainage of defrost water accumulation. The unit must be situated to permit free unobstructed drainage of the defrost water and ice. A minimum 2" clearance under the outdoor coil is required in the milder climates.
GROUND LEVEL PRE-INSTALLATION DETAILS
The unit should be set on a solid, level foundation - preferably a concrete slab at least 4 inches thick. The slab should be above ground level and surrounded by a graveled area for good drainage. Any slab used as a unit’s foundation should not adjoin the building as it is possible that sound and vibration may be transmitted to the structure.
MAJOR COMPONENTS
The unit includes a hermetically sealed refrigerating system (con­sisting of a compressor, condenser coil, evaporator coil with flowrator), an indoor blower, a condenser fan and all necessary internal electrical wiring. The heat pump also includes a revers­ing valve, solenoid, defrost thermostat and control and loss of charge protection. The system is factory-evacuated, charged and performance tested. Refrigerant amount and type are indicated on rating plate.
PRE-INSTALLATION CHECKS
Before attempting any installation, the following points should be considered:
Structural strength of supporting members
Clearances and provision for servicing
Power supply and wiring
Air duct connections
Drain facilities and connections
Location may be on any four sides of a home, manufactured or modular, to minimize noise
CLEARANCES AND A CCESSIBILITY
The unit is designed to be located outside the building with un­obstructed condenser air inlet and discharge. Additionally, the unit must be situated to permit access for service and installa­tion. Condenser air enters from three sides. Air discharges upward from the top of the unit. Refrigerant gauge connections are made on the right side of the unit as you face the compressor compartment. Electrical connections can be made either on the right, bottom or duct panel side of the unit. The best and most common application is for the unit to be located 10” from wall (4” minimum) with the connection side facing the wall. This “close to the wall” application minimizes exposed wiring.
Ground Level Installation
ROOF TOP P RE-INSTALLATION DETAILS
Ensure that the roof is weather tight and allows proper drainage of condensation. Use steel or treated wood beams as unit support for load distribution.
NOTE: To ensure proper condensate drainage, unit must be in­stalled in a level position.
To avoid possible property damage or personal injury, the
roof must have sufficient structural strength to carry the weight of the unit(s) and snow or water loads as required by local codes. Consult a structural engineer to determine the weight capabilities of the roof.
4
The unit may be installed directly on wood floors or on
Class A, Class B, or Class C roof covering material.
To avoid possible personal injury, a safe, flat surface for
service personnel should be provided.
Rooftop Installation
ROOF C URB INSTALLATIONS O NLY
Roof Curb Installation
RIGGING DETAILS
WARNING
O PREVENT PROPERTY DAMAGE, THE UNIT SHOULD REMAIN IN AN UPRIGHT
T
POSITION DURING ALL RIGGING AND MOVING OPERATIONS.
LIFTING AND MOVING WHEN A CRANE IS USED, PLACE THE UNIT IN AN
ADEQUATE CABLE SLING.
T
O FACILITATE
WARNING
O AVOID POSSIBLE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH,
T
ENSURE THE ROOF HAS SUFFICIENT STRUCTURAL STRENGTH TO CARRY THE
WEIGHT OF THE UNIT(S), ROOF CURB, SNOW LOADS, AND WATER LOADS AS
REQUIRED BY LOCAL CODES.
DETERMINE THE WEIGHT CAPABILITIES OF THE ROOF.
CONSULT A STRUCTURAL ENGINEER TO
CAUTION
O AVOID POSSIBLE PERSONAL INJURY, A SAFE, FLAT SURFACE FOR SERVICE
T
PERSONNEL SHOULD BE PROVIDED.
IMPORTANT: If using bottom discharge with roof curb, duct work
should be attached to the curb prior to installing the unit. Lower unit carefully onto roof mounting curb. While rigging unit, center of gravity will cause condenser end to be lower than supply air end.
NOTE: Sufficient structural support must be determined prior to locating and mounting the curb and package unit.
Curb insulation, cant strips, flashing and general roofing material are furnished by the contractor.
Curbing must be installed in compliance with the National Roofing Contractors Association Manual. Construct duct work using current industry guidelines. The duct work must be placed into the roof curb before mounting the package unit.
Rigging
CIRCULATING AIR AND FILTERS
AIRFLOW C ONVERSION
Units can easily be converted from horizontal to down-discharge airflow delivery. In down-discharge or high static installations, the installer should measure the total external static and review the blower performance charts before performing the installation. In some installations it will be necessary to change the blower speed to provide proper air flow.
Horizontal Air Flow (Applies to 3 phase models)
Single phase models are shipped without horizontal duct covers. If needed, these kits may be ordered through Goodman’s Service Parts department.
5
Loading...
+ 11 hidden pages