Goodman EFR02 Installation Manual

EFR02
EXTERNAL FIL TER RACK KIT
INSTALLATION INSTRUCTIONS
DESCRIPTION
This external filter rack kit is intended to provide a location, external to the furnace casing, for installation of a permanent filter. The rack is designed to mount over the indoor air blower compartment area of either side panel, and provide filter reten­tion as well as a location for attaching return air ductwork.
ATTENTION INSTALLING PERSONNEL
As a professional installer, you have an obligation to know the product better than the customer. This includes all safety pre­cautions and related items.
Prior to actual installation, thoroughly familiarize yourself with this Instruction Manual. Pay special attention to all safety warn­ings. Often during installation or repair, it is possible to place yourself in a position which is more hazardous than when the unit is in operation.
Remember, it is your responsibility to install the product safely and to know it well enough to be able to instruct a customer in its safe use.
Safety is a matter of common sense... a matter of thinking before acting. Most dealers have a list of specific, good safety practices... follow them.
The precautions listed in this Installation Manual are intended as supplemental to existing practices. However, if there is a direct conflict between existing practices and the content of this manual, the precautions listed here take precedence.
RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION
KIT CONTENTS
1 Sheet Metal Rack Assembly 1 1 Plastic Filter Clip
6 #10 x 1/2" Self-Drilling Screws
IO-828 9/2014
16" x 25" x 1" Permanent (Washable) High - Velocity F ilte r
Installation Ins tructions
CONTENTS
Important Information .......................................... 2
Location & Placement ...........................................2
Number of Kits R equired ........................................ 2
Less than 5 Tons of Airflow ............................... 2
Five T ons of Airflow ........................................ 2
Installation Precautions and Considerations ................. 3
Disconnect Electrical Power ............................... 3
Furnace Airflow Requirements ............................ 3
Drain Hose Relocation ..................................... 3
Mating Ductwork Dimension .............................. 3
Filter Access and R emoval................................. 3
Installation Procedure ........................................... 3
Filter Care ................................................... 3
Filter Replacement ......................................... 4
IMPORTANT INFORMA TION
Contact a local propane gas supplier
about installing a gas detecting warning device.
NOTE: To ensure proper operation, install, operate and main­tain the unit in accordance with these installation instructions, all local building codes and ordinances. In their absence, follow the latest edition of the National Fuel Gas Code (NFPA 54/ANSI Z223.1), and/or CAN/CSA B149.1 Installation Codes.
LOCA TION & PLACEMENT
This kit is designed for side panel application to Upflow 34.5” 90% gas furnace models. Refer to Installation Precautions and Considerations section for details.
NUMBER OF KITS REQUIRED
Less Than Five Tons of Airflow
Installations supporting less than five tons of airflow require only one return air ductwork connection when a permanent filter is used. For this case one filter rack kit is required.
NOTE: This filter rack cannot be applied to a bottom return on 90% furnaces.
Five Tons of Airflow
Installations supporting five tons of airflow require two return air ductwork connections. If both connections are side panel con­nections, two filter rack kits are required. When a bottom return is used in conjunction with a side panel connection, a permanent filter must be installed in the bottom return and a filter rack kit used for the side panel connection.
NOTE: This filter rack cannot be applied to a bottom return on 90% furnaces.