Page 1
DX16TC
High-Efficiency,
ComfortNet™-Compatible,
Split System Air Conditioner
Up to 16 SEER
■ Contents
Nomenclature ........................................ 2
Product Specicaons ........................... 3
Expanded Cooling Data ......................... 4
AHRI Rangs ........................................ 20
Dimensions .......................................... 25
Wiring Diagram ................................... 26
Accessories .......................................... 27
■ Standard Features
• Two-Stage Copeland® UltraTech scroll compressor
• High-density foam compressor sound blanket
• ComfortNet™ Communicaons
System compable
• Advanced Copeland®
CoreSense™ technology
• High-eciency, ECM condenser fan motor
• In communicang mode, two low-voltage
wires to outdoor unit required
• Diagnosc indicator lights
and fault code storage
• Color-coded terminal strip
• Factory-installed lter drier
• Coil and ambient temperature sensors
• Sweat connecon service valves with easy
access to gauge ports
• AHRI Cered; ETL Listed
■ Cabinet Features
• Heavy-gauge galvanized-steel cabinet
with grille-style sound control top design
• Custom Nickel Gray powder-paint nish
• 500-hour salt-spray tested
• Wire fan discharge grille
• Steel louver coil guard
• Top and side maintenance access
• Single-panel access to controls with space
provided for eld-installed accessories
• When properly anchored, meets the 2010 Florida
Building Code unit integrity requirements for
hurricane-type winds (Anchor bracket kits available.)
* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Unit Replacement Limited Warranty
and 12-Year Parts Limited Warranty, online registraon must be completed within 60 days of installaon. Addional requirements for annual
maintenance are required for the Unit Replacement Limited Warranty. Online registraon and some of the addional requirements are not required
in California or Quebec.
SS-DX16TC www.daikincomfort.com 11/15
Supersedes 5/15
Page 2
1 2 3,4 5 6 7,8,9 10 11 12
DDaikin Minorrevision
XACR410A Majorrevision
SEER 1208/230VSinglePhase60Hz
2220/240VSinglePhase50Hz
3208/230VThreePhase60Hz
1616SEER 4460VThreePhase60Hz
5380/415VThreePhase50Hz
SSingleStage TonnageNominal
TTwoStage 0181½tons 0423½tons
DTandem 0242tons 0484tons
RThreeStage 0302½tons 0605tons
VVariableSpeed 0363tons 0615tons
CComfortNet4WireReady EExport
LComfortNetLite NNominal
Nomenclature
2 www.daikincomfort.com SS-DX16TC
Page 3
Product Specifications
DX16TC
0241A*
DX16TC
0361A*
DX16TC
0481A*
DX16TC
0601A*
Cooling Capacity
Nominal Cooling (BTU/h) 24,000 36,000 48,000 60,000
Decibels 71 73 74 75
Compressor
RLA 11.7 15.3 21.2 28.8
LRA 58.3 83.0 104.0 152.9
Condenser Fan Motor
Horsepower (RPM) 1/6 1/6 1/6 1/6
FLA 1.1 0.9 1.2 1.2
Refrigeration System
Refrigerant Line Size
Liquid Line Size (“O.D.) ⅜" ⅜" ⅜" ⅜"
Sucon Line Size (“O.D.) ¾" ⅞" 1⅛" 1⅛"
Refrigerant Connecon Size
Liquid Valve Size (“O.D.) ⅜" ⅜" ⅜" ⅜"
Sucon Valve Size (“O.D.) ¾" ¾" ⅞" ⅞"
Valve Connecon Type Sweat Sweat Sweat Sweat
Refrigerant Charge 88 96 135 200
Electrical Data
Voltage-Phase-Hz 208/230-1 208/230-1-60 208/230-1-60 208/230-1-60
Minimum Circuit Ampacity ² 15.7 20.0 27.7 37.2
Max. Overcurrent Protecon ³ 20 35 45 60
Min / Max Volts 197/253 197/253 197/253 197/253
Power Supply ½" or ¾" ½" or ¾" ½" or ¾" ½" or ¾"
Equipment Weight (lbs) 180 184 219 279
Ship Weight (lbs) 198 202 241 301
¹ Tested and rated in accordance with AHRI Standard 210/240
² Wire size should be determined in accordance with Naonal Electrical Codes; extensive wire runs will require larger wire sizes
³ Must use me-delay fuses or HACR-type circuit breakers of the same size as noted.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• Installer will need to supply ⅞” to 1⅛” adapters for sucon line connecons.
• Unit is charged with refrigerant for 15’ of ⅜” liquid line. System charge
must be adjusted per Installaon Instrucons Final Charge Procedure.
• Installaon of these units requires the specied TXV Kit to be installed on the indoor coil.
THE SPECIFIED TXV IS DETERMINED BY THE OUTDOOR UNIT NOT THE INDOOR COIL.
SS-DX16TC www.daikincomfort.com 3
Page 4
Expanded Cooling Dtaa — DX16TC0241A* / CA*F3636*6D*+MBVC1200**-1A*+TXV High Stage
Outdoor Ambient Temperature
- 21.9 22.7 24.8 - 20.8 21.5 23.6 - 19.3 20.0 21.9 -
Entering Indoor Wet Bulb Temperature
22 20 16 11 22 20 16 11 22 20 16 11 20 19 15 10
5.4 5.6 - 5.7 5.8 6.1 - 6.1 6.3 6.5 - 6.4 6.6 6.9 - 6.7 6.9 7.2 -
5.2 5.4 5.3 5.5 5.7 6.0 5.8 6.0 6.2 6.5 6.2 6.4 6.7 6.9 6.5 6.7 7.0 7.3 6.8 7.0 7.3 7.6
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 -
S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.78 0.65 0.45 - 0.78 0.65 0.45 -
MBh 21.1 21.8 23.9 - 20.6 21.3 23.4 - 20.1 20.8 22.8 - 19.6 20.3 22.3 - 18.6 19.3 21.1 - 17.3 17.9 19.6 -
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 1.36 1.39 1.44 - 1.47 1.51 1.56 - 1.57 1.61 1.67 - 1.66 1.70 1.76 - 1.74 1.78 1.84 - 1.81 1.85 1.91 -
700
HI PR 215 232 245 - 242 260 275 - 275 296 312 - 313 337 356 - 352 379 400 - 389 419 442 -
Lo PR 101 108 118 - 107 114 125 - 111 119 129 - 117 125 136 - 123 130 142 - 127 135 147 -
Amps 4.8 4.9 5.1 - 5.3 5.4 5.7 - 5.7 5.9 6.1 - 6.1 6.3 6.6 - 6.5 6.6 6.9 - 6.7 6.9 7.2 -
∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.65 0.45 - 0.80 0.67 0.47 - 0.81 0.68 0.47 -
MBh 22.8 23.7 25.9 - 22.3 23.1 25.3 - 21.8 22.6 24.7 - 21.2 22.0 24.1 - 20.2 20.9 22.9 - 18.7 19.4 21.2 -
kW 1.40 1.43 1.48 - 1.51 1.55 1.60 - 1.62 1.66 1.71 - 1.71 1.75 1.81 - 1.79 1.83 1.90 - 1.86 1.90 1.97 -
820
70
HI PR 222 239 252 - 249 268 283 - 283 305 322 - 323 347 367 - 363 391 412 - 401 432 456 -
Lo PR 105 111 122 - 111 118 128 - 115 122 133 - 121 128 140 - 126 135 147 - 131 139 152 -
Amps 4.8 4.9 5.1 - 5.3 5.4 5.7 - 5.7 5.9 6.2 - 6.1 6.3 6.6 - 6.5 6.7 6.9 - 6.8 7.0 7.3 -
MBh 23.5 24.4 26.7 - 23.0 23.8 26.1 - 22.4 23.2 25.5
∆T 18 15 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 15 12 - 17 14 11 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
kW 1.41 1.44 1.49 - 1.53 1.56 1.62 - 1.63 1.67 1.73 - 1.73 1.77 1.83 - 1.80 1.85 1.91 - 1.87 1.92 1.99 -
HI PR 224 241 255 - 252 271 286 - 286 308 325 - 326 351 370 - 367 394 417 - 405 436 460 -
Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 153 -
Amps 4.7 4.8 5.1 - 5.2
900
MBh 21.4 22.1 23.9 25.6 20.9 21.6 23.3 25.0 20.4 21.0 22.8 24.4 19.9 20.5 22.2 23.8 18.9 19.5 21.1 22.7 17.5 18.1 19.6 21.0
S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.89 0.79 0.60 0.39
∆T 22 20 16 11 22 20 17 11 22 20 17 11 22 20 17 12 22 20 17 11 20 19 15 11
kW 1.37 1.40 1.45 1.50 1.49 1.52 1.57 1.63 1.59 1.63 1.68 1.74 1.68 1.72 1.78 1.84 1.76 1.80 1.86 1.93 1.82 1.87 1.93 2.00
HI PR 218 234 247 258 244 263 277 289 278 299 315 329 316 340 359 375 356 383 404 422 393 423 447 466
Lo PR 103 109 119 127 108 115 126 134 113 120 131 139 118 126 137 146 124 132 144 153 128 136 149 159
Amps 4.9 5.0 5.2 5.4 5.4 5.5 5.7 6.0 5.8 6.0 6.2 6.5 6.2 6.4 6.6 6.9 6.5 6.7 7.0 7.3 6.8 7.0 7.3 7.6
700
MBh 23.2 23.9 25.9 27.8 22.7 23.4 25.3 27.1 22.1 22.8 24.7 26.5 21.6 22.2 24.1 25.8 20.5 21.1 22.9 24.5 19.0 19.6 21.2 22.7
S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40
∆T 21 20 16 11 22 20 16 11
kW 1.41 1.44 1.49 1.54 1.53 1.56 1.62 1.68 1.63 1.67 1.73 1.79 1.73 1.77 1.83 1.90 1.80 1.85 1.91 1.98 1.87 1.92 1.99 2.06
HI PR 224 241 255 266 252 271 286 298 286 308 325 339 326 351 370 386 367 395 417 435 405 436 460 480
Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 153 163
Amps 4.8 5.0
820
75
MBh 23.9 24.6 26.7 28.6 23.4 24.1 26.0 27.9 22.8 23.5 25.4 27.3 22.2 22.9 24.8 26.6 21.1 21.8 23.6 25.3 19.6 20.2 21.8 23.4
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.61 0.39 0.92 0.83 0.62 0.40 0.96 0.86 0.65 0.42 0.97 0.86 0.65 0.42
∆T 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10
kW 1.42 1.45 1.50 1.56 1.54 1.58 1.63 1.69 1.65 1.69 1.75 1.81 1.74 1.78 1.85 1.91 1.82 1.86 1.93 2.00 1.89 1.94 2.00 2.08
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329 354 374 390 370 399 421 439 409 440 465 485
Lo PR 107 114 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165
Amps 4.7 4.9 5.1 5.3 5.3 5.4 5.7 5.9 5.7 5.9 6.2 6.4 6.1 6.3 6.6 6.9 6.5 6.7 7.0 7.3 6.8 7.0 7.3 7.6
900
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
4 www.daikincomfort.com SS-DX16TC
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 5
Expanded Cooling Dtaa — DX16TC0241A* / CA*F3636*6D*+MBVC1200**-1A*+TXV High Stage
Outdoor Ambient Temperature
27.1 22.6 23.1 24.7 26.4 21.5 22.0 23.5 25.1 19.9 20.4 21.8 23.3
Entering Indoor Wet Bulb Temperature
26 25 24 21 26 26 24 21 24 25 24 21 23 23 22 19
5.3 5.5 5.7 6.0 5.8 6.0 6.2 6.5 6.2 6.4 6.7 7.0 6.6 6.8 7.0 7.4 6.9 7.1 7.4 7.7
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
5.1 5.3 5.5 5.5 5.6 5.9 6.1 5.9 6.1 6.4 6.6 6.3 6.5 6.8 7.1 6.7 6.9 7.2 7.5 7.0 7.2 7.5 7.8
∆T 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 24 23 20 16 23 22 19 15
S/T 0.85 0.80 0.65 0.48 0.88 0.82 0.67 0.50 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 0.97 0.91 0.74 0.55 0.97 0.91 0.74 0.56
MBh 21.8 22.3 23.8 25.5 21.3 21.8 23.3 24.9 20.8 21.3 22.7 24.3 20.3 20.7 22.2 23.7 19.3 19.7 21.0 22.5 17.9 18.2 19.5 20.8
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 1.38 1.42 1.46 1.52 1.50 1.54 1.59 1.65 1.60 1.64 1.70 1.76 1.69 1.73 1.80 1.86 1.77 1.81 1.88 1.95 1.84 1.88 1.95 2.02
700
Amps 4.9 5.0 5.3 5.5 5.4 5.6 5.8 6.0 5.9 6.0 6.3 6.5 6.3 6.4 6.7 7.0 6.6 6.8 7.1 7.4 6.9 7.1 7.4 7.7
HI PR 220 236 250 260 247 265 280 292 280 302 319 332 319 344 363 378 359 387 408 426 397 427 451 470
Lo PR 104 110 120 128 109 116 127 135 114 121 132 141 119 127 139 148 125 133 145 155 129 138 150 160
MBh 23.6 24.1 25.8 27.6 23.1 23.6 25.2 26.9 22.5 23.0 24.6 26.3 22.0 22.5 24.0 25.7 20.9 21.3 22.8 24.4 19.3 19.8 21.1 22.6
S/T 0.88 0.83 0.67 0.50 0.91 0.86 0.70 0.52 0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.95 0.77 0.58
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 22 19 15
kW 1.42 1.45 1.50 1.56 1.54 1.58 1.63 1.69 1.65 1.69 1.75 1.81 1.74 1.78 1.85 1.91 1.82 1.86 1.93 2.00 1.89 1.94 2.00 2.08
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329 354 374 390 370 399 421 439 409 440 465 485
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165
Amps 4.9 5.0 5.2 5.5 5.4 5.6 5.8 6.1 5.9 6.0 6.3 6.6 6.3 6.4 6.7 7.0 6.6 6.8 7.1 7.4 6.9 7.1 7.4 7.7
820
80
MBh 24.3 24.9 26.6 28.4 23.8 24.3 26.0 27.7 23.2 23.7 25.3
S/T 0.92 0.87 0.70 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.81 0.60
∆T 23 22 19 15 23 22 19 15 24 22 19 15 23 22 20 16 22 22 19 15 20 21 18 14
kW 1.43 1.47 1.52 1.57 1.55 1.59 1.65 1.71 1.66 1.70 1.76 1.83 1.76 1.80 1.86 1.93 1.84 1.88 1.95 2.02 1.91 1.95 2.02 2.10
HI PR 229 246 260 271 257 276 292 304 292 314 332 346 333 358 378 394 374 403 425 443 413 445 470 490
Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
Amps 4.8 4.9 5.2 5.4
900
MBh 22.2 22.6 23.7 25.3 21.7 22.1 23.1 24.7 21.2 21.6 22.6 24.1 20.6 21.0 22.0 23.5 19.6 20.0 20.9 22.3 18.2 18.5 19.4 20.7
S/T 0.89 0.86 0.77 0.63 0.92 0.89 0.80 0.65 0.95 0.91 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 0.99 0.89 0.72
∆T 26 26 24 21 26 26 24 21 26 26 24 21 26 26 25 21 26 26 24 21 24 24 23 20
kW 1.40 1.43 1.48 1.53 1.51 1.55 1.60 1.66 1.62 1.66 1.71 1.78 1.71 1.75 1.81 1.88 1.79 1.83 1.90 1.96 1.85 1.90 1.97 2.04
HI PR 222 239 252 263 249 268 283 295 283 305 322 336 323 347 367 382 363 390 412 430 401 431 456 475
Lo PR 105 111 121 129 110 118 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 162
Amps 5.0 5.1 5.3 5.5 5.5 5.6 5.9 6.1 5.9 6.1 6.3 6.6 6.3 6.5 6.8 7.1 6.7 6.8 7.1 7.4 7.0 7.1 7.4 7.8
700
MBh 24.0 24.5 25.7 27.4 23.5 23.9 25.1 26.8 22.9 23.4 24.5 26.1 22.4 22.8 23.9 25.5 21.2 21.7 22.7 24.2 19.7 20.1 21.0 22.4
S/T 0.92 0.89 0.80 0.65 0.96 0.92 0.83 0.68 0.98 0.95 0.85 0.69 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.75
∆T 25 25 24 21 26 25 24 21
kW 1.43 1.47 1.52 1.57 1.55 1.59 1.65 1.71 1.66 1.70 1.76 1.83 1.76 1.80 1.86 1.93 1.84 1.88 1.95 2.02 1.91 1.95 2.02 2.10
HI PR 229 246 260 271 257 276 292 304 292 314 332 346 333 358 378 394 374 403 425 443 413 445 470 490
Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
Amps 4.9
820
85
MBh 24.8 25.2 26.4 28.2 24.2 24.7 25.8 27.6 23.6 24.1 25.2 26.9 23.0 23.5 24.6 26.2 21.9 22.3 23.4 24.9 20.3 20.7 21.6 23.1
S/T 0.97 0.93 0.84 0.68 1.00 0.97 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.78
∆T 24.5 24 23 20 25 24 23 20 24 24 23 20 24 24 23 20 22 23 23 20 21 21 21 19
kW 1.45 1.48 1.53 1.58 1.57 1.61 1.66 1.72 1.68 1.72 1.78 1.84 1.77 1.82 1.88 1.95 1.85 1.90 1.97 2.04 1.92 1.97 2.04 2.12
HI PR 231 249 263 274 259 279 295 307 295 317 335 349 336 361 382 398 378 407 429 448 417 449 474 495
Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
Amps 4.9 5.0 5.2 5.5 5.4 5.6 5.8 6.1 5.9 6.0 6.3 6.6 6.3 6.5 6.7 7.0 6.6 6.8 7.1 7.4 6.9 7.1 7.4 7.8
900
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions Amps = outdoor unit amps (comp.+fan)
SS-DX16TC www.daikincomfort.com 5
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 6
Expanded Cooling Dtaa — DX16TC0241A* / CA*F3636*6D*+MBVC1200**-1A*+TXV Low Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
- 15.4 16.0 17.5 - 14.7 15.2 16.6 - 13.6 14.1 15.4 -
21 19 16 11 21 19 16 11 21 19 16 11 19 18 15 10
3.3 - 3.4 3.5 3.7 - 3.7 3.8 4.0 - 3.9 4.1 4.2 - 4.2 4.3 4.5 - 4.3 4.5 4.7 -
3.5 3.6 3.6 3.7 3.8 4.0 3.9 4.0 4.1 4.3 4.1 4.2 4.4 4.6 4.3 4.4 4.6 4.8 4.5 4.6 4.8 5.0
∆T 19 16 12 - 19 17 13 - 19 17 13 - 19 17 13 - 19 16 12 - 18 15 12 -
S/T 0.70 0.58 0.40 - 0.72 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
MBh 16.2 16.8 18.4 - 15.8 16.4 17.9 - 15.4 16.0 17.5 - 15.0 15.6 17.1 - 14.3 14.8 16.2 - 13.2 13.7 15.0 -
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 0.93 0.95 0.98 - 1.00 1.02 1.05 - 1.06 1.09 1.12 - 1.12 1.14 1.18 - 1.17 1.19 1.23 - 1.21 1.24 1.28 -
490
HI PR 209 224 237 - 234 252 266 - 266 286 302 - 303 326 345 - 341 367 388 - 377 406 428 -
Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 154 -
Amps 3.2 3.3 3.5 - 3.6 3.7 3.8 - 3.8 3.9 4.1 - 4.1 4.2 4.4 - 4.3 4.4 4.6 - 4.5 4.6 4.8 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
MBh 16.4 17.0 18.6 - 16.0 16.6 18.2 - 15.7 16.2 17.8 - 15.3 15.8 17.3 - 14.5 15.0 16.5 - 13.4 13.9 15.3 -
kW 0.94 0.96 0.99 - 1.01 1.03 1.07 - 1.08 1.10 1.14 - 1.14 1.16 1.20 - 1.18 1.21 1.25 - 1.23 1.25 1.30 -
550
70
HI PR 212 228 241 - 238 256 271 - 271 291 308 - 308 332 350 - 347 373 394 - 383 413 436 -
Lo PR 108 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -
Amps 3.2 3.3 3.4 - 3.5 3.6 3.8 - 3.8 3.9 4.1 - 4.1 4.2 4.3 - 4.3 4.4 4.6 - 4.5 4.6 4.8 -
MBh 16.6 17.2 18.8 - 16.2 16.8 18.4 - 15.8 16.4 18.0
∆T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 10 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
kW 0.94 0.96 0.99 - 1.02 1.04 1.07 - 1.08 1.10 1.14 - 1.14 1.16 1.20 - 1.19 1.21 1.25 - 1.23 1.26 1.30 -
HI PR 213 229 242 - 239 257 271 - 272 292 309 - 309 333 352 - 348 375 395 - 385 414 437 -
Lo PR 108 115 125 - 114 121 132 - 118 126 138 - 124 132 144 - 130 139 151 - 135 143 157 -
Amps 3.1 3.2
630
MBh 16.4 16.9 18.3 19.7 16.1 16.5 17.9 19.2 15.7 16.1 17.5 18.8 15.3 15.8 17.0 18.3 14.5 15.0 16.2 17.4 13.5 13.9 15.0 16.1
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
∆T 22 20 16 11 22 20 17 12 22 20 17 12 22 21 17 12 22 20 17 11 21 19 15 11
kW 0.93 0.95 0.98 1.02 1.01 1.03 1.06 1.10 1.07 1.10 1.13 1.17 1.13 1.15 1.19 1.23 1.18 1.20 1.24 1.29 1.22 1.25 1.29 1.33
HI PR 211 227 239 250 236 254 269 280 269 289 306 319 306 330 348 363 345 371 392 408 381 410 433 451
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 134 142 155 165
Amps 3.3 3.4 3.5 3.6 3.6 3.7 3.8 4.0 3.9 4.0 4.1 4.3 4.1 4.2 4.4 4.6 4.3 4.5 4.6 4.8 4.5 4.6 4.8 5.0
490
MBh 16.7 17.2 18.6 20.0 16.3 16.8 18.2 19.5 15.9 16.4 17.7 19.0 15.5 16.0 17.3 18.6 14.8 15.2 16.4 17.6 13.7 14.1 15.2 16.3
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
∆T 21 19 16 11 21 19 16 11
kW 0.95 0.97 1.00 1.03 1.02 1.04 1.08 1.11 1.09 1.11 1.15 1.19 1.14 1.17 1.21 1.25 1.19 1.22 1.26 1.31 1.24 1.26 1.31 1.35
HI PR 214 231 244 254 241 259 273 285 274 294 311 324 312 335 354 369 351 377 398 415 387 417 440 459
Lo PR 109 116 126 134 115 122 133 142 119 127 139 148 125 133 146 155 131 140 153 162 136 145 158 168
Amps 3.2 3.3
550
75
MBh 16.9 17.4 18.8 20.2 16.5 17.0 18.4 19.7 16.1 16.6 17.9 19.2 15.7 16.2 17.5 18.8 14.9 15.3 16.6 17.8 13.8 14.2 15.4 16.5
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.96 0.86 0.65 0.42 0.96 0.86 0.65 0.42
∆T 19 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10
kW 0.95 0.97 1.00 1.03 1.02 1.05 1.08 1.12 1.09 1.11 1.15 1.19 1.15 1.17 1.21 1.25 1.20 1.22 1.27 1.31 1.24 1.27 1.31 1.36
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 313 336 355 370 352 378 400 417 388 418 441 460
Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 169
Amps 3.1 3.2 3.4 3.5 3.5 3.5 3.7 3.9 3.7 3.8 4.0 4.2 4.0 4.1 4.3 4.5 4.2 4.3 4.5 4.7 4.4 4.5 4.7 4.9
630
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
6 www.daikincomfort.com SS-DX16TC
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 7
Expanded Cooling Dtaa — DX16TC0241A* / CA*F3636*6D*+MBVC1200**-1A*+TXV Low Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
19.1 16.0 16.3 17.4 18.6 15.2 15.5 16.6 17.7 14.0 14.4 15.3 16.4
3.4 3.5 3.5 3.6 3.7 3.9 3.8 3.9 4.0 4.2 4.0 4.1 4.3 4.5 4.3 4.4 4.6 4.7 4.4 4.6 4.8 5.0
25 25 23 20 24 25 23 20 23 23 23 20 21 22 22 19
3.5 3.7 3.6 3.7 3.9 4.1 3.9 4.0 4.2 4.4 4.2 4.3 4.5 4.7 4.4 4.5 4.7 4.9 4.6 4.7 4.9 5.1
∆T 24 23 20 16 25 24 21 16 25 24 21 16 25 24 21 17 25 24 20 16 23 22 19 15
S/T 0.87 0.82 0.67 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.94 0.76 0.57
MBh 16.7 17.1 18.3 19.5 16.3 16.7 17.8 19.1 16.0 16.3 17.4 18.6 15.6 15.9 17.0 18.2 14.8 15.1 16.1 17.3 13.7 14.0 15.0 16.0
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 0.94 0.96 0.99 1.03 1.02 1.04 1.07 1.11 1.08 1.10 1.14 1.18 1.14 1.16 1.20 1.24 1.19 1.21 1.25 1.30 1.23 1.26 1.30 1.34
490
Amps 3.3 3.4 3.5 3.7 3.6 3.7 3.9 4.0 3.9 4.0 4.2 4.4 4.2 4.3 4.5 4.6 4.4 4.5 4.7 4.9 4.6 4.7 4.9 5.1
HI PR 213 229 242 252 239 257 271 283 272 292 309 322 309 333 352 367 348 375 396 413 385 414 437 456
Lo PR 108 115 125 133 114 121 132 141 118 126 138 147 124 132 145 154 130 139 151 161 135 143 157 167
MBh 17.0 17.4 18.6 19.8 16.6 17.0 18.1 19.4 16.2 16.6 17.7 18.9 15.8 16.2 17.3 18.4 15.0 15.3 16.4 17.5 13.9 14.2 15.2 16.2
S/T 0.90 0.85 0.69 0.52 0.94 0.88 0.72 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.97 0.79 0.59
∆T 23 22 19 15 23 22 20 16 23 22 20 16 24 23 20 16 23 22 19 16 21 21 18 14
kW 0.95 0.98 1.01 1.04 1.03 1.05 1.09 1.12 1.10 1.12 1.16 1.20 1.15 1.18 1.22 1.26 1.20 1.23 1.27 1.32 1.25 1.28 1.32 1.36
HI PR 217 233 246 257 243 261 276 288 276 297 314 328 315 339 358 373 354 381 402 420 391 421 445 464
Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 127 135 147 157 133 141 154 164 137 146 159 170
Amps 3.3 3.4 3.5 3.6 3.6 3.7 3.9 4.0 3.9 4.0 4.2 4.3 4.1 4.3 4.4 4.6 4.4 4.5 4.7 4.9 4.6 4.7 4.9 5.1
550
80
MBh 17.2 17.5 18.7 20.0 16.8 17.1 18.3 19.6 16.4 16.7 17.9
S/T 0.92 0.86 0.70 0.53 0.96 0.90 0.73 0.55 0.98 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 0.98 0.80 0.60 1.00 1.00 0.81 0.60
∆T 22 21 18 14 22 21 18 15 22 21 18 15 22 21 18 15 21 21 18 15 19 20 17 14
kW 0.96 0.98 1.01 1.04 1.03 1.05 1.09 1.13 1.10 1.12 1.16 1.20 1.16 1.18 1.22 1.27 1.21 1.23 1.28 1.32 1.25 1.28 1.32 1.37
HI PR 217 234 247 257 244 262 277 289 277 298 315 328 316 340 359 374 355 382 404 421 392 422 446 465
Lo PR 110 117 128 136 116 124 135 144 121 129 140 149 127 135 147 157 133 142 155 165 138 146 160 170
Amps 3.2 3.3
630
MBh 17.0 17.4 18.2 19.4 16.6 17.0 17.8 18.9 16.2 16.6 17.3 18.5 15.8 16.1 16.9 18.0 15.0 15.3 16.1 17.1 13.9 14.2 14.9 15.9
S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.91 0.74
∆T 26 26 24 21 26 26 24 21 26 26 25 21 26 26 25 21 25 26 24 21 23 24 23 20
kW 0.95 0.97 1.00 1.03 1.02 1.05 1.08 1.12 1.09 1.11 1.15 1.19 1.15 1.17 1.21 1.25 1.20 1.22 1.27 1.31 1.24 1.27 1.31 1.36
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 312 336 355 370 352 378 399 417 388 418 441 460
Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
Amps 3.3 3.4 3.6 3.7 3.7 3.8 3.9 4.1 4.0 4.1 4.2 4.4 4.2 4.3 4.5 4.7 4.4 4.5 4.7 4.9 4.6 4.7 4.9 5.1
490
MBh 17.3 17.6 18.5 19.7 16.9 17.2 18.0 19.2 16.5 16.8 17.6 18.8 16.1 16.4 17.2 18.3 15.3 15.6 16.3 17.4 14.2 14.4 15.1 16.1
S/T 0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
∆T 25 24 23 20 25 25 23 20
kW 0.96 0.98 1.01 1.05 1.04 1.06 1.10 1.13 1.11 1.13 1.17 1.21 1.16 1.19 1.23 1.27 1.21 1.24 1.28 1.33 1.26 1.29 1.33 1.38
HI PR 219 235 249 259 245 264 279 291 279 300 317 331 318 342 361 377 358 385 406 424 395 425 449 468
Lo PR 111 118 129 137 117 125 136 145 122 129 141 151 128 136 148 158 134 143 156 166 139 147 161 171
Amps 3.3 3.4
550
85
MBh 17.5 17.8 18.6 19.9 17.1 17.4 18.2 19.4 16.6 17.0 17.8 19.0 16.2 16.6 17.3 18.5 15.4 15.7 16.5 17.6 14.3 14.6 15.3 16.3
S/T 0.97 0.93 0.84 0.68 1.00 0.97 0.87 0.71 1.00 0.99 0.89 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.78
∆T 23 23 22 19 23 23 22 19 23 23 22 19 22 23 22 19 21 22 22 19 20 20 20 18
kW 0.96 0.99 1.02 1.05 1.04 1.06 1.10 1.14 1.11 1.13 1.17 1.21 1.17 1.19 1.23 1.28 1.22 1.25 1.29 1.33 1.26 1.29 1.33 1.38
HI PR 219 236 249 260 246 265 280 292 280 301 318 332 319 343 362 378 359 386 408 425 396 426 450 470
Lo PR 111 118 129 138 117 125 136 145 122 130 142 151 128 136 149 159 134 143 156 166 139 148 161 172
Amps 3.2 3.3 3.4 3.6 3.5 3.6 3.8 3.9 3.8 3.9 4.1 4.3 4.1 4.2 4.4 4.5 4.3 4.4 4.6 4.8 4.5 4.6 4.8 5.0
630
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions Amps = outdoor unit amps (comp.+fan)
SS-DX16TC www.daikincomfort.com 7
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 8
Expanded Cooling Dtaa — DX16TC0361A* / CA*F3743*6D*+MBVC1600**-1A*+TXV High Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
- 31.9 33.1 36.2 - 30.3 31.4 34.4 - 28.1 29.1 31.9 -
21 19 16 11 21 20 16 11 21 19 16 11 20 18 15 10
7.6 - 7.9 8.1 8.5 - 8.6 8.8 9.2 - 9.2 9.5 9.9 - 9.7 10.0 10.5 - 10.2 10.5 11.0 -
7.8 8.2 8.1 8.3 8.7 9.1 8.8 9.1 9.5 9.9 9.4 9.7 10.2 10.6 10.0 10.3 10.7 11.2 10.4 10.8 11.2 11.7
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.78 0.65 0.45 - 0.78 0.65 0.45 -
MBh 30.7 31.9 34.9 - 30.0 31.1 34.1 - 29.3 30.4 33.3 - 28.6 29.6 32.5 - 27.2 28.2 30.8 - 25.2 26.1 28.6 -
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 2.03 2.08 2.16 - 2.21 2.27 2.35 - 2.37 2.43 2.52 - 2.51 2.58 2.67 - 2.63 2.70 2.80 - 2.74 2.80 2.91 -
1100
HI PR 215 232 245 - 242 260 275 - 275 296 312 - 313 337 356 - 352 379 400 - 389 419 442 -
Lo PR 101 108 118 - 107 114 125 - 111 119 129 - 117 125 136 - 123 130 142 - 127 135 147 -
Amps 7.1 7.3 7.6 - 7.9 8.1 8.5 - 8.6 8.8 9.2 - 9.2 9.5 9.9 - 9.7 10.0 10.4 - 10.1 10.4 10.9 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 18 16 12 - 17 15 11 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.65 0.45 - 0.80 0.67 0.47 - 0.81 0.68 0.47 -
MBh 33.3 34.5 37.8 - 32.5 33.7 36.9 - 31.7 32.9 36.1 - 31.0 32.1 35.2 - 29.4 30.5 33.4 - 27.3 28.3 31.0 -
kW 2.09 2.14 2.22 - 2.28 2.33 2.42 - 2.44 2.50 2.59 - 2.59 2.65 2.75 - 2.71 2.78 2.88 - 2.81 2.88 2.99 -
1200
70
HI PR 222 239 252 - 249 268 283 - 283 305 322 - 323 347 367 - 363 391 412 - 401 432 456 -
Lo PR 105 111 122 - 111 118 128 - 115 122 133 - 121 128 140 - 126 135 147 - 131 139 152 -
Amps 7.2 7.4 7.8 - 8.0 8.2 8.6 - 8.7 9.0 9.4 - 9.3 9.6 10.0 - 9.9 10.2 10.6 - 10.3 10.6 11.1 -
MBh 34.3 35.5 38.9 - 33.5 34.7 38.0 - 32.7 33.9 37.1
∆T 17 15 11 - 18 15 11 - 18 15 12 - 18 15 12 - 17 15 11 - 16 14 11 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
kW 2.11 2.16 2.24 - 2.30 2.36 2.44 - 2.46 2.52 2.62 - 2.61 2.67 2.77 - 2.73 2.80 2.91 - 2.84 2.91 3.02 -
HI PR 224 241 255 - 252 271 286 - 286 308 325 - 326 351 370 - 367 394 417 - 405 436 460 -
Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 153 -
Amps 7.0 7.3
1350
MBh 31.3 32.2 34.8 37.4 30.5 31.4 34.0 36.5 29.8 30.7 33.2 35.6 29.1 29.9 32.4 34.8 27.6 28.4 30.8 33.0 25.6 26.3 28.5 30.6
S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.89 0.79 0.60 0.39
∆T 21 20 16 11 21 20 16 11 21 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 2.05 2.10 2.18 2.26 2.24 2.29 2.37 2.46 2.40 2.45 2.54 2.64 2.54 2.60 2.70 2.80 2.66 2.72 2.82 2.93 2.76 2.83 2.94 3.05
HI PR 218 234 247 258 244 263 277 289 278 299 315 329 316 340 359 375 356 383 404 422 393 423 447 466
Lo PR 103 109 119 127 108 115 126 134 113 120 131 139 118 126 137 146 124 132 144 153 128 136 149 159
Amps 7.2 7.4 7.7 8.1 8.0 8.2 8.6 9.0 8.7 8.9 9.3 9.7 9.3 9.6 10.0 10.4 9.8 10.1 10.5 11.0 10.3 10.6 11.0 11.5
1100
MBh 33.9 34.9 37.7 40.5 33.1 34.1 36.9 39.6 32.3 33.2 36.0 38.6 31.5 32.4 35.1 37.7 29.9 30.8 33.3 35.8 27.7 28.5 30.9 33.2
S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40
∆T 21 19 16 11 21 19 16 11
kW 2.11 2.16 2.24 2.32 2.30 2.36 2.44 2.53 2.46 2.53 2.62 2.72 2.61 2.68 2.77 2.88 2.73 2.80 2.91 3.02 2.84 2.91 3.02 3.13
HI PR 224 241 255 266 252 271 286 298 286 308 325 339 326 351 370 386 367 395 417 435 405 436 460 480
Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 153 163
Amps 7.3 7.5
1200
75
MBh 34.9 35.9 38.9 41.7 34.1 35.1 38.0 40.7 33.3 34.2 37.1 39.8 32.4 33.4 36.2 38.8 30.8 31.7 34.4 36.9 28.6 29.4 31.8 34.2
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.61 0.39 0.92 0.83 0.62 0.40 0.96 0.86 0.65 0.42 0.97 0.86 0.65 0.42
∆T 20 18 15 10 20 19 15 11 20 19 15 11 20 19 15 11 20 19 15 10 19 17 14 10
kW 2.13 2.18 2.26 2.35 2.32 2.38 2.46 2.56 2.49 2.55 2.64 2.74 2.63 2.70 2.80 2.90 2.76 2.83 2.93 3.04 2.87 2.94 3.05 3.16
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329 354 374 390 370 399 421 439 409 440 465 485
Lo PR 107 114 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165
Amps 7.1 7.3 7.7 8.1 7.9 8.2 8.6 9.0 8.7 8.9 9.3 9.8 9.3 9.6 10.0 10.5 9.9 10.2 10.6 11.1 10.3 10.6 11.1 11.6
1350
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
8 www.daikincomfort.com SS-DX16TC
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 9
Expanded Cooling Dtaa — DX16TC0361A* / CA*F3743*6D*+MBVC1600**-1A*+TXV High Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
39.5 33.0 33.7 36.1 38.5 31.4 32.1 34.2 36.6 29.1 29.7 31.7 33.9
7.8 8.2 8.0 8.3 8.7 9.1 8.8 9.0 9.5 9.9 9.4 9.7 10.1 10.6 10.0 10.3 10.7 11.2 10.4 10.8 11.2 11.7
25 25 23 20 25 25 24 20 24 24 23 20 22 22 22 19
8.0 8.4 8.3 8.5 8.9 9.3 9.0 9.3 9.7 10.1 9.7 9.9 10.4 10.8 10.2 10.5 11.0 11.5 10.7 11.0 11.5 12.0
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15
S/T 0.85 0.80 0.65 0.48 0.88 0.82 0.67 0.50 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 0.97 0.91 0.74 0.55 0.97 0.91 0.74 0.56
MBh 31.8 32.5 34.7 37.1 31.1 31.7 33.9 36.3 30.3 31.0 33.1 35.4 29.6 30.2 32.3 34.5 28.1 28.7 30.7 32.8 26.0 26.6 28.4 30.4
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 2.07 2.12 2.20 2.28 2.26 2.31 2.40 2.48 2.42 2.48 2.57 2.66 2.56 2.62 2.72 2.82 2.68 2.75 2.85 2.96 2.79 2.86 2.96 3.07
1100
Amps 7.3 7.5 7.8 8.2 8.1 8.3 8.7 9.1 8.8 9.0 9.4 9.8 9.4 9.7 10.1 10.5 9.9 10.2 10.7 11.1 10.4 10.7 11.1 11.6
HI PR 220 236 250 260 247 265 280 292 280 302 319 332 319 344 363 378 359 387 408 426 397 427 451 470
Lo PR 104 110 120 128 109 116 127 135 114 121 132 141 119 127 139 148 125 133 145 155 129 138 150 160
MBh 34.5 35.2 37.6 40.2 33.7 34.4 36.8 39.3 32.9 33.6 35.9 38.4 32.1 32.8 35.0 37.4 30.5 31.1 33.3 35.5 28.2 28.8 30.8 32.9
S/T 0.88 0.83 0.67 0.50 0.91 0.86 0.70 0.52 0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.95 0.77 0.58
∆T 23 22 19 15 24 23 20 16 24 23 20 16 24 23 20 16 23 22 19 16 22 21 18 15
kW 2.13 2.18 2.26 2.35 2.32 2.38 2.46 2.56 2.49 2.55 2.64 2.74 2.63 2.70 2.80 2.90 2.76 2.83 2.93 3.04 2.87 2.94 3.05 3.16
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329 354 374 390 370 399 421 439 409 440 465 485
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165
Amps 7.4 7.6 7.9 8.3 8.2 8.4 8.8 9.2 8.9 9.2 9.6 10.0 9.6 9.8 10.3 10.7 10.1 10.4 10.9 11.3 10.6 10.9 11.4 11.9
1200
80
MBh 35.5 36.3 38.8 41.4 34.7 35.4 37.9 40.5 33.8 34.6 37.0
S/T 0.92 0.87 0.70 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.81 0.60
∆T 22 21 19 15 23 22 19 15 23 22 19 15 22 22 19 15 21 22 19 15 20 20 17 14
kW 2.15 2.20 2.28 2.37 2.34 2.40 2.49 2.58 2.51 2.57 2.67 2.77 2.66 2.73 2.83 2.93 2.79 2.86 2.96 3.07 2.90 2.97 3.08 3.19
HI PR 229 246 260 271 257 276 292 304 292 314 332 346 333 358 378 394 374 403 425 443 413 445 470 490
Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
Amps 7.2 7.4
1350
MBh 32.4 33.0 34.6 36.9 31.6 32.2 33.8 36.0 30.9 31.5 32.9 35.1 30.1 30.7 32.1 34.3 28.6 29.2 30.5 32.6 26.5 27.0 28.3 30.2
S/T 0.89 0.86 0.77 0.63 0.92 0.89 0.80 0.65 0.95 0.91 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 0.99 0.89 0.72
∆T 25 25 23 20 26 25 24 21 26 25 24 21 26 25 24 21 25 25 24 20 23 23 22 19
kW 2.09 2.14 2.22 2.30 2.28 2.33 2.42 2.51 2.44 2.50 2.59 2.69 2.58 2.65 2.75 2.85 2.71 2.78 2.88 2.99 2.81 2.88 2.99 3.10
HI PR 222 239 252 263 249 268 283 295 283 305 322 336 323 347 367 382 363 390 412 430 401 431 456 475
Lo PR 105 111 121 129 110 118 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 162
Amps 7.3 7.6 7.9 8.3 8.2 8.4 8.8 9.2 8.9 9.1 9.5 9.9 9.5 9.8 10.2 10.6 10.0 10.3 10.8 11.2 10.5 10.8 11.3 11.7
1100
MBh 35.1 35.7 37.4 39.9 34.3 34.9 36.6 39.0 33.4 34.1 35.7 38.1 32.6 33.3 34.8 37.2 31.0 31.6 33.1 35.3 28.7 29.3 30.6 32.7
S/T 0.92 0.89 0.80 0.65 0.96 0.92 0.83 0.68 0.98 0.95 0.85 0.69 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.75
∆T 25 24 23 20 25 25 23 20
kW 2.15 2.20 2.28 2.37 2.34 2.40 2.49 2.58 2.51 2.57 2.67 2.77 2.66 2.73 2.83 2.93 2.79 2.86 2.96 3.07 2.90 2.97 3.08 3.19
HI PR 229 246 260 271 257 276 292 304 292 314 332 346 333 358 378 394 374 403 425 443 413 445 470 490
Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
Amps 7.4 7.7
1200
85
MBh 36.1 36.8 38.6 41.1 35.3 36.0 37.7 40.2 34.4 35.1 36.8 39.2 33.6 34.2 35.9 38.3 31.9 32.5 34.1 36.4 29.6 30.1 31.6 33.7
S/T 0.97 0.93 0.84 0.68 1.00 0.97 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.78
∆T 24 23 22 19 24 24 22 19 23 24 22 19 23 23 23 20 22 22 22 19 20 21 21 18
kW 2.17 2.22 2.30 2.39 2.36 2.42 2.51 2.60 2.53 2.60 2.69 2.79 2.68 2.75 2.85 2.96 2.81 2.88 2.99 3.10 2.92 3.00 3.11 3.22
HI PR 231 249 263 274 259 279 295 307 295 317 335 349 336 361 382 398 378 407 429 448 417 449 474 495
Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
Amps 7.3 7.5 7.9 8.2 8.1 8.4 8.8 9.2 8.9 9.1 9.6 10.0 9.5 9.8 10.3 10.7 10.1 10.4 10.9 11.3 10.6 10.9 11.4 11.9
1350
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions Amps = outdoor unit amps (comp.+fan)
SS-DX16TC www.daikincomfort.com 9
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 10
Expanded Cooling Dtaa — DX16TC0361A* / CA*F3743*6D*+MBVC1600**-1A*+TXV Low Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
- 22.5 23.3 25.5 - 21.4 22.1 24.3 - 19.8 20.5 22.5 -
31 28 23 16 31 28 23 16 30 28 23 16 28 26 21 15
4.8 - 5.0 5.1 5.4 - 5.4 5.6 5.9 - 5.8 6.0 6.3 - 6.2 6.4 6.6 - 6.5 6.7 6.9 -
5.0 5.3 5.2 5.4 5.6 5.8 5.7 5.8 6.1 6.3 6.0 6.2 6.5 6.8 6.4 6.6 6.9 7.2 6.7 6.9 7.2 7.5
∆T 28 24 18 - 28 24 18 - 28 24 18 - 28 24 18 - 28 24 18 - 26 22 17 -
S/T 0.70 0.58 0.40 - 0.72 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
MBh 23.6 24.4 26.8 - 23.0 23.9 26.2 - 22.5 23.3 25.5 - 21.9 22.7 24.9 - 20.8 21.6 23.7 - 19.3 20.0 21.9 -
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 1.35 1.39 1.43 - 1.47 1.50 1.55 - 1.57 1.61 1.66 - 1.66 1.70 1.76 - 1.73 1.77 1.84 - 1.80 1.84 1.91 -
780
HI PR 209 224 237 - 234 252 266 - 266 286 302 - 303 326 345 - 341 367 388 - 377 406 428 -
Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 154 -
Amps 4.6 4.8 5.0 - 5.1 5.3 5.5 - 5.6 5.7 6.0 - 6.0 6.1 6.4 - 6.3 6.5 6.7 - 6.6 6.8 7.1 -
∆T 26 23 17 - 26 23 17 - 27 23 17 - 27 23 18 - 26 23 17 - 25 21 16 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
MBh 23.9 24.8 27.2 - 23.4 24.2 26.6 - 22.8 23.7 25.9 - 22.3 23.1 25.3 - 21.2 21.9 24.0 - 19.6 20.3 22.3 -
kW 1.37 1.41 1.45 - 1.49 1.53 1.58 - 1.59 1.63 1.69 - 1.68 1.72 1.78 - 1.76 1.80 1.87 - 1.83 1.87 1.94 -
840
70
HI PR 212 228 241 - 238 256 271 - 271 291 308 - 308 332 350 - 347 373 394 - 383 413 436 -
Lo PR 108 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -
Amps 4.6 4.8 5.0 - 5.1 5.3 5.5 - 5.6 5.8 6.0 - 6.0 6.2 6.4 - 6.3 6.5 6.8 - 6.6 6.8 7.1 -
MBh 24.2 25.1 27.5 - 23.6 24.5 26.8 - 23.1 23.9 26.2
∆T 25 21 16 - 25 21 16 - 25 22 16 - 25 22 16 - 25 21 16 - 23 20 15 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
kW 1.38 1.41 1.46 - 1.49 1.53 1.58 - 1.60 1.63 1.69 - 1.69 1.73 1.79 - 1.76 1.81 1.87 - 1.83 1.87 1.94 -
HI PR 213 229 242 - 239 257 271 - 272 292 309 - 309 333 352 - 348 375 395 - 385 414 437 -
Lo PR 108 115 125 - 114 121 132 - 118 126 138 - 124 132 144 - 130 139 151 - 135 143 157 -
Amps 4.5 4.6
945
MBh 24.0 24.7 26.7 28.7 23.4 24.1 26.1 28.0 22.9 23.5 25.5 27.4 22.3 23.0 24.9 26.7 21.2 21.8 23.6 25.3 19.6 20.2 21.9 23.5
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
∆T 32 29 24 17 32 30 24 17 32 30 24 17 33 30 25 17 32 30 24 17 30 28 23 16
kW 1.37 1.40 1.45 1.50 1.48 1.52 1.57 1.62 1.58 1.62 1.68 1.74 1.67 1.71 1.77 1.84 1.75 1.79 1.85 1.92 1.81 1.86 1.92 1.99
HI PR 211 227 239 250 236 254 269 280 269 289 306 319 306 330 348 363 345 371 392 408 381 410 433 451
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 134 142 155 165
Amps 4.7 4.8 5.0 5.3 5.2 5.4 5.6 5.8 5.6 5.8 6.1 6.3 6.0 6.2 6.5 6.7 6.4 6.5 6.8 7.1 6.6 6.8 7.1 7.4
780
MBh 24.3 25.1 27.1 29.1 23.8 24.5 26.5 28.4 23.2 23.9 25.9 27.8 22.6 23.3 25.2 27.1 21.5 22.2 24.0 25.7 19.9 20.5 22.2 23.8
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
∆T 30 28 23 16 31 28 23 16
kW 1.39 1.42 1.47 1.52 1.50 1.54 1.59 1.65 1.61 1.64 1.70 1.76 1.70 1.74 1.80 1.87 1.78 1.82 1.88 1.95 1.84 1.89 1.95 2.03
HI PR 214 231 244 254 241 259 273 285 274 294 311 324 312 335 354 369 351 377 398 415 387 417 440 459
Lo PR 109 116 126 134 115 122 133 142 119 127 139 148 125 133 146 155 131 140 153 162 136 145 158 168
Amps 4.7 4.8
840
75
MBh 24.6 25.3 27.4 29.4 24.0 24.7 26.8 28.7 23.4 24.1 26.1 28.0 22.9 23.6 25.5 27.4 21.7 22.4 24.2 26.0 20.1 20.7 22.4 24.1
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.96 0.86 0.65 0.42 0.96 0.86 0.65 0.42
∆T 28 26 21 15 29 26 22 15 29 26 22 15 29 27 22 15 29 26 22 15 27 25 20 14
kW 1.39 1.42 1.47 1.52 1.51 1.54 1.60 1.65 1.61 1.65 1.71 1.77 1.70 1.74 1.81 1.87 1.78 1.82 1.89 1.96 1.85 1.89 1.96 2.03
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 313 336 355 370 352 378 400 417 388 418 441 460
Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 169
Amps 4.5 4.7 4.9 5.1 5.1 5.2 5.4 5.7 5.5 5.7 5.9 6.2 5.9 6.1 6.3 6.6 6.2 6.4 6.7 7.0 6.5 6.7 7.0 7.3
945
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
10 www.daikincomfort.com SS-DX16TC
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 11
Expanded Cooling Dtaa — DX16TC0361A* / CA*F3743*6D*+MBVC1600**-1A*+TXV Low Stage
Outdoor Ambient Temperature
27.8 23.3 23.8 25.4 27.2 22.1 22.6 24.1 25.8 20.5 20.9 22.4 23.9
Entering Indoor Wet Bulb Temperature
36 36 34 29 35 36 34 30 34 34 34 29 31 32 31 27
5.3 5.5 5.7 6.0 5.8 5.9 6.2 6.5 6.2 6.4 6.6 6.9 6.5 6.7 7.0 7.3 6.8 7.0 7.3 7.6
5.0 5.2 5.1 5.3 5.5 5.8 5.6 5.7 6.0 6.3 6.0 6.1 6.4 6.7 6.3 6.5 6.8 7.1 6.6 6.8 7.1 7.4
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
∆T 36 34 30 24 36 35 30 24 36 35 30 24 36 35 30 24 36 34 30 24 33 32 28 22
S/T 0.87 0.82 0.67 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.94 0.76 0.57
MBh 24.4 24.9 26.6 28.5 23.8 24.4 26.0 27.8 23.3 23.8 25.4 27.2 22.7 23.2 24.8 26.5 21.6 22.0 23.5 25.2 20.0 20.4 21.8 23.3
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 1.38 1.41 1.46 1.51 1.49 1.53 1.58 1.64 1.60 1.63 1.69 1.75 1.69 1.73 1.79 1.85 1.76 1.81 1.87 1.94 1.83 1.87 1.94 2.01
780
Amps 4.8 4.9 5.1 5.3 5.3 5.4 5.6 5.9 5.7 5.9 6.1 6.4 6.1 6.3 6.5 6.8 6.4 6.6 6.9 7.2 6.7 6.9 7.2 7.5
HI PR 213 229 242 252 239 257 271 283 272 292 309 322 309 333 352 367 348 375 396 413 385 414 437 456
Lo PR 108 115 125 133 114 121 132 141 118 126 138 147 124 132 145 154 130 139 151 161 135 143 157 167
MBh 24.8 25.3 27.1 28.9 24.2 24.7 26.4 28.2 23.6 24.1 25.8 27.6 23.1 23.6 25.2 26.9 21.9 22.4 23.9 25.6 20.3 20.7 22.1 23.7
S/T 0.90 0.85 0.69 0.52 0.94 0.88 0.72 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.97 0.79 0.59
∆T 34 32 28 22 34 33 28 23 34 33 29 23 34 33 29 23 33 33 28 23 31 30 26 21
kW 1.40 1.43 1.48 1.53 1.52 1.55 1.61 1.66 1.62 1.66 1.72 1.78 1.71 1.75 1.82 1.88 1.79 1.83 1.90 1.97 1.86 1.90 1.97 2.04
HI PR 217 233 246 257 243 261 276 288 276 297 314 328 315 339 358 373 354 381 402 420 391 421 445 464
Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 127 135 147 157 133 141 154 164 137 146 159 170
Amps 4.7 4.9 5.1 5.3 5.3 5.4 5.7 5.9 5.7 5.9 6.1 6.4 6.1 6.3 6.6 6.9 6.5 6.6 6.9 7.2 6.8 6.9 7.2 7.6
840
80
MBh 25.0 25.6 27.3 29.2 24.4 25.0 26.7 28.5 23.9 24.4 26.1
S/T 0.92 0.86 0.70 0.53 0.96 0.90 0.73 0.55 0.98 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 0.98 0.80 0.60 1.00 1.00 0.81 0.60
∆T 32 30 26 21 32 31 27 21 32 31 27 21 32 31 27 22 30 31 27 21 28 29 25 20
kW 1.40 1.43 1.48 1.54 1.52 1.56 1.61 1.67 1.63 1.66 1.72 1.78 1.72 1.76 1.82 1.89 1.80 1.84 1.91 1.97 1.86 1.91 1.98 2.05
HI PR 217 234 247 257 244 262 277 289 277 298 315 328 316 340 359 374 355 382 404 421 392 422 446 465
Lo PR 110 117 128 136 116 124 135 144 121 129 140 149 127 135 147 157 133 142 155 165 138 146 160 170
Amps 4.6 4.7
945
MBh 24.8 25.3 26.5 28.3 24.3 24.7 25.9 27.6 23.7 24.1 25.3 27.0 23.1 23.5 24.7 26.3 21.9 22.4 23.4 25.0 20.3 20.7 21.7 23.2
S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.91 0.74
∆T 38 37 35 31 38 38 36 31 38 38 36 31 39 38 36 31 37 37 35 31 34 35 33 29
kW 1.39 1.42 1.47 1.52 1.51 1.54 1.60 1.65 1.61 1.65 1.71 1.77 1.70 1.74 1.80 1.87 1.78 1.82 1.89 1.96 1.85 1.89 1.96 2.03
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 312 336 355 370 352 378 399 417 388 418 441 460
Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
Amps 4.8 4.9 5.2 5.4 5.3 5.5 5.7 6.0 5.8 5.9 6.2 6.5 6.2 6.3 6.6 6.9 6.5 6.7 7.0 7.3 6.8 7.0 7.3 7.6
780
MBh 25.2 25.7 26.9 28.7 24.6 25.1 26.3 28.0 24.0 24.5 25.7 27.4 23.5 23.9 25.0 26.7 22.3 22.7 23.8 25.4 20.6 21.0 22.0 23.5
S/T 0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
∆T 36 35 33 29 36 36 34 29
kW 1.41 1.44 1.49 1.55 1.53 1.57 1.62 1.68 1.64 1.67 1.73 1.80 1.73 1.77 1.83 1.90 1.81 1.85 1.92 1.99 1.88 1.92 1.99 2.06
HI PR 219 235 249 259 245 264 279 291 279 300 317 331 318 342 361 377 358 385 406 424 395 425 449 468
Lo PR 111 118 129 137 117 125 136 145 122 129 141 151 128 136 148 158 134 143 156 166 139 147 161 171
Amps 4.8 4.9 5.2 5.4
840
85
MBh 25.5 26.0 27.2 29.0 24.9 25.4 26.6 28.3 24.3 24.8 25.9 27.7 23.7 24.1 25.3 27.0 22.5 22.9 24.0 25.6 20.8 21.2 22.3 23.7
S/T 0.97 0.93 0.84 0.68 1.00 0.97 0.87 0.71 1.00 0.99 0.89 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.78
∆T 34 33 31 27 34 34 32 28 33 34 32 28 33 33 32 28 31 31 32 27 29 29 30 26
kW 1.41 1.45 1.50 1.55 1.53 1.57 1.63 1.68 1.64 1.68 1.74 1.80 1.73 1.77 1.84 1.90 1.81 1.86 1.92 1.99 1.88 1.93 2.00 2.07
HI PR 219 236 249 260 246 265 280 292 280 301 318 332 319 343 362 378 359 386 408 425 396 426 450 470
Lo PR 111 118 129 138 117 125 136 145 122 130 142 151 128 136 149 159 134 143 156 166 139 148 161 172
Amps 4.7 4.8 5.0 5.2 5.2 5.3 5.6 5.8 5.6 5.8 6.1 6.3 6.0 6.2 6.5 6.8 6.4 6.6 6.9 7.2 6.7 6.9 7.2 7.5
945
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions Amps = outdoor unit amps (comp.+fan)
SS-DX16TC www.daikincomfort.com 11
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 12
Expanded Cooling Dtaa — DX16TC0481A* / CA*F4860*6D*+MBVC2000**-1A*+TXV High Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
- 42.8 44.4 48.7 - 40.7 42.2 46.2 - 37.7 39.1 42.8 -
21 20 16 11 21 20 16 11 21 19 16 11 20 18 15 10
9.7 10.2 - 10.5 10.8 11.4 - 11.5 11.9 12.4 - 12.4 12.7 13.3 - 13.1 13.5 14.1 - 13.7 14.2 14.8 -
10.0 10.5 11.0 10.8 11.2 11.7 12.2 11.8 12.2 12.7 13.3 12.7 13.1 13.7 14.3 13.4 13.8 14.4 15.1 14.1 14.5 15.1 15.8
∆T 18 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.78 0.65 0.45 - 0.78 0.65 0.45 -
MBh 41.3 42.8 46.9 - 40.3 41.8 45.8 - 39.4 40.8 44.7 - 38.4 39.8 43.6 - 36.5 37.8 41.4 - 33.8 35.0 38.4 -
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 2.71 2.78 2.89 - 2.96 3.03 3.15 - 3.18 3.26 3.38 - 3.37 3.45 3.58 - 3.53 3.62 3.76 - 3.67 3.76 3.91 -
1400
HI PR 215 232 245 - 242 260 275 - 275 296 312 - 313 337 356 - 352 379 400 - 389 419 442 -
Lo PR 101 108 118 - 107 114 125 - 111 119 129 - 117 125 136 - 123 130 142 - 127 135 147 -
Amps 9.6 9.9 10.3 - 10.6 11.0 11.5 - 11.6 11.9 12.5 - 12.4 12.8 13.4 - 13.1 13.5 14.1 - 13.7 14.1 14.8 -
∆T 18 16 12 - 18 16 12 - 18 16 12 - 19 16 12 - 18 16 12 - 17 15 11 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.65 0.45 - 0.80 0.67 0.47 - 0.81 0.68 0.47 -
MBh 44.7 46.3 50.8 - 43.7 45.3 49.6 - 42.6 44.2 48.4 - 41.6 43.1 47.2 - 39.5 41.0 44.9 - 36.6 37.9 41.6 -
kW 2.79 2.86 2.97 - 3.05 3.12 3.24 - 3.27 3.35 3.48 - 3.47 3.55 3.69 - 3.63 3.73 3.87 - 3.78 3.88 4.02 -
1600
70
HI PR 222 239 252 - 249 268 283 - 283 305 322 - 323 347 367 - 363 391 412 - 401 432 456 -
Lo PR 105 111 122 - 111 118 128 - 115 122 133 - 121 128 140 - 126 135 147 - 131 139 152 -
Amps 9.6 9.9 10.4 - 10.7 11.0 11.5 - 11.7 12.0 12.6 - 12.5 12.9 13.5 - 13.3 13.7 14.3 - 13.9 14.3 14.9 -
MBh 46.1 47.7 52.3 - 45.0 46.6 51.1 - 43.9 45.5 49.9
∆T 17 15 11 - 18 15 12 - 18 15 12 - 18 15 12 - 18 15 12 - 16 14 11 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
kW 2.82 2.89 3.00 - 3.07 3.15 3.27 - 3.30 3.38 3.51 - 3.50 3.59 3.72 - 3.67 3.76 3.90 - 3.82 3.91 4.06 -
HI PR 224 241 255 - 252 271 286 - 286 308 325 - 326 351 370 - 367 394 417 - 405 436 460 -
Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 153 -
Amps 9.4
1800
MBh 42.0 43.2 46.8 50.2 41.0 42.2 45.7 49.0 40.0 41.2 44.6 47.9 39.0 40.2 43.5 46.7 37.1 38.2 41.3 44.4 34.4 35.4 38.3 41.1
S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.89 0.79 0.60 0.39
∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 16 11 21 20 16 11 20 18 15 10
kW 2.74 2.81 2.91 3.02 2.99 3.06 3.18 3.30 3.21 3.29 3.41 3.54 3.40 3.49 3.62 3.76 3.57 3.66 3.79 3.94 3.71 3.80 3.94 4.10
HI PR 218 234 247 258 244 263 277 289 278 299 315 329 316 340 359 375 356 383 404 422 393 423 447 466
Lo PR 103 109 119 127 108 115 126 134 113 120 131 139 118 126 137 146 124 132 144 153 128 136 149 159
Amps 9.7 10.0 10.4 10.9 10.8 11.1 11.6 12.1 11.7 12.1 12.6 13.2 12.6 12.9 13.5 14.1 13.3 13.7 14.3 14.9 13.9 14.3 14.9 15.6
1400
MBh 45.5 46.8 50.7 54.4 44.4 45.7 49.5 53.1 43.4 44.6 48.3 51.9 42.3 43.6 47.1 50.6 40.2 41.4 44.8 48.1 37.2 38.3 41.5 44.5
S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40
∆T 21 19 16 11 21 20 16 11
kW 2.82 2.89 3.00 3.11 3.08 3.15 3.27 3.39 3.30 3.38 3.51 3.64 3.50 3.59 3.72 3.87 3.67 3.76 3.91 4.05 3.82 3.91 4.06 4.22
HI PR 224 241 255 266 252 271 286 298 286 308 325 339 326 351 370 386 367 395 417 435 405 436 460 480
Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 153 163
Amps 9.7
1600
75
MBh 46.8 48.2 52.2 56.0 45.7 47.1 51.0 54.7 44.7 46.0 49.8 53.4 43.6 44.9 48.6 52.1 41.4 42.6 46.1 49.5 38.3 39.5 42.7 45.9
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.61 0.39 0.92 0.83 0.62 0.40 0.96 0.86 0.65 0.42 0.97 0.86 0.65 0.42
∆T 20 19 15 10 20 19 15 11 20 19 15 11 21 19 15 11 20 19 15 11 19 17 14 10
kW 2.85 2.92 3.03 3.14 3.10 3.18 3.30 3.43 3.33 3.42 3.54 3.68 3.53 3.62 3.76 3.90 3.71 3.80 3.94 4.09 3.85 3.95 4.10 4.26
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329 354 374 390 370 399 421 439 409 440 465 485
Lo PR 107 114 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165
Amps 9.5 9.8 10.3 10.8 10.6 11.0 11.5 12.0 11.6 12.0 12.6 13.1 12.5 12.9 13.5 14.1 13.3 13.7 14.3 14.9 13.9 14.3 15.0 15.7
1800
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
12 www.daikincomfort.com SS-DX16TC
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 13
Expanded Cooling Dtaa — DX16TC0481A* / CA*F4860*6D*+MBVC2000**-1A*+TXV High Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
53.0 44.3 45.3 48.4 51.8 42.1 43.0 46.0 49.2 39.0 39.9 42.6 45.5
9.9 10.4 10.9 10.8 11.1 11.6 12.2 11.8 12.1 12.7 13.3 12.7 13.0 13.6 14.3 13.4 13.8 14.4 15.1 14.1 14.5 15.1 15.8
25 25 24 20 25 25 24 21 24 24 23 20 22 23 22 19
10.3 10.7 11.2 11.1 11.4 12.0 12.5 12.1 12.5 13.0 13.6 13.0 13.4 14.0 14.6 13.7 14.1 14.8 15.4 14.4 14.8 15.5 16.1
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 19 15
S/T 0.85 0.80 0.65 0.48 0.88 0.82 0.67 0.50 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 0.97 0.91 0.74 0.55 0.97 0.91 0.74 0.56
MBh 42.7 43.6 46.6 49.9 41.7 42.6 45.6 48.7 40.7 41.6 44.5 47.5 39.7 40.6 43.4 46.4 37.8 38.6 41.2 44.1 35.0 35.7 38.2 40.8
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 2.77 2.84 2.94 3.05 3.02 3.09 3.21 3.33 3.24 3.32 3.44 3.57 3.43 3.52 3.65 3.79 3.60 3.69 3.83 3.98 3.74 3.84 3.98 4.13
1400
Amps 9.8 10.1 10.6 11.0 10.9 11.2 11.7 12.3 11.9 12.2 12.8 13.3 12.7 13.1 13.7 14.3 13.4 13.8 14.4 15.1 14.1 14.5 15.1 15.8
HI PR 220 236 250 260 247 265 280 292 280 302 319 332 319 344 363 378 359 387 408 426 397 427 451 470
Lo PR 104 110 120 128 109 116 127 135 114 121 132 141 119 127 139 148 125 133 145 155 129 138 150 160
MBh 46.3 47.3 50.5 54.0 45.2 46.2 49.4 52.8 44.1 45.1 48.2 51.5 43.1 44.0 47.0 50.2 40.9 41.8 44.7 47.7 37.9 38.7 41.4 44.2
S/T 0.88 0.83 0.67 0.50 0.91 0.86 0.70 0.52 0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.95 0.77 0.58
∆T 23 22 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 22 21 18 15
kW 2.85 2.92 3.03 3.14 3.10 3.18 3.30 3.43 3.33 3.42 3.55 3.68 3.53 3.62 3.76 3.90 3.71 3.80 3.94 4.09 3.85 3.95 4.10 4.26
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329 354 374 390 370 399 421 439 409 440 465 485
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165
Amps 9.8 10.1 10.6 11.1 11.0 11.3 11.8 12.4 12.0 12.3 12.9 13.5 12.8 13.2 13.8 14.4 13.6 14.0 14.6 15.3 14.2 14.6 15.3 16.0
1600
80
MBh 47.7 48.7 52.0 55.6 46.6 47.6 50.8 54.3 45.5 46.4 49.6
S/T 0.92 0.87 0.70 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.81 0.60
∆T 22 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 22 22 19 15 20 20 18 14
kW 2.87 2.94 3.05 3.17 3.13 3.21 3.33 3.46 3.36 3.45 3.58 3.71 3.57 3.66 3.80 3.94 3.74 3.84 3.98 4.13 3.89 3.99 4.14 4.30
HI PR 229 246 260 271 257 276 292 304 292 314 332 346 333 358 378 394 374 403 425 443 413 445 470 490
Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
Amps 9.6
1800
MBh 43.5 44.3 46.4 49.5 42.5 43.3 45.3 48.4 41.4 42.2 44.2 47.2 40.4 41.2 43.2 46.0 38.4 39.2 41.0 43.7 35.6 36.3 38.0 40.5
S/T 0.89 0.86 0.77 0.63 0.92 0.89 0.80 0.65 0.95 0.91 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 0.99 0.89 0.72
∆T 25 25 24 20 26 25 24 21 26 25 24 21 26 25 24 21 25 25 24 21 23 23 22 19
kW 2.79 2.86 2.97 3.08 3.05 3.12 3.24 3.36 3.27 3.35 3.48 3.61 3.47 3.55 3.69 3.83 3.63 3.73 3.87 4.01 3.78 3.87 4.02 4.17
HI PR 222 239 252 263 249 268 283 295 283 305 322 336 323 347 367 382 363 390 412 430 401 431 456 475
Lo PR 105 111 121 129 110 118 128 137 115 122 133 142 121 128 140 149 126 134 147 156 131 139 152 162
Amps 9.9 10.2 10.7 11.2 11.0 11.4 11.9 12.4 12.0 12.3 12.9 13.5 12.8 13.2 13.8 14.4 13.6 14.0 14.6 15.2 14.2 14.6 15.3 15.9
1400
MBh 47.1 48.0 50.3 53.6 46.0 46.9 49.1 52.4 44.9 45.8 47.9 51.1 43.8 44.7 46.8 49.9 41.6 42.4 44.4 47.4 38.5 39.3 41.2 43.9
S/T 0.92 0.89 0.80 0.65 0.96 0.92 0.83 0.68 0.98 0.95 0.85 0.69 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.75
∆T 25 25 23 20 25 25 23 20
kW 2.87 2.94 3.05 3.17 3.13 3.21 3.33 3.46 3.36 3.45 3.58 3.71 3.57 3.66 3.80 3.94 3.74 3.84 3.98 4.13 3.89 3.99 4.14 4.30
HI PR 229 246 260 271 257 276 292 304 292 314 332 346 333 358 378 394 374 403 425 443 413 445 470 490
Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
Amps 10.0
1600
85
MBh 48.5 49.4 51.8 55.2 47.4 48.3 50.6 54.0 46.2 47.1 49.4 52.7 45.1 46.0 48.2 51.4 42.9 43.7 45.8 48.8 39.7 40.5 42.4 45.2
S/T 0.97 0.93 0.84 0.68 1.00 0.97 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.78
∆T 24 24 22 19 24 24 23 20 24 24 23 20 23 23 23 20 22 22 22 19 20 21 21 18
kW 2.90 2.97 3.08 3.20 3.16 3.24 3.36 3.49 3.40 3.48 3.61 3.75 3.60 3.69 3.83 3.98 3.78 3.87 4.02 4.17 3.93 4.03 4.18 4.34
HI PR 231 249 263 274 259 279 295 307 295 317 335 349 336 361 382 398 378 407 429 448 417 449 474 495
Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
Amps 9.8 10.1 10.5 11.1 10.9 11.2 11.8 12.3 11.9 12.3 12.9 13.4 12.8 13.2 13.8 14.4 13.6 14.0 14.6 15.3 14.2 14.7 15.3 16.0
1800
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions Amps = outdoor unit amps (comp.+fan)
SS-DX16TC www.daikincomfort.com 13
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 14
Expanded Cooling Dtaa — DX16TC0481A* / CA*F4860*6D*+MBVC2000**-1A*+TXV Low Stage
Outdoor Ambient Temperature
- 30.2 31.3 34.3 - 28.7 29.7 32.6 - 26.6 27.6 30.2 -
Entering Indoor Wet Bulb Temperature
41 38 31 21 41 38 31 22 41 38 31 21 38 35 29 20
6.7 7.0 6.9 7.1 7.4 7.8 7.5 7.7 8.1 8.4 8.1 8.3 8.7 9.1 8.5 8.8 9.2 9.6 8.9 9.2 9.6 10.0
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
6.1 6.4 - 6.6 6.8 7.1 - 7.2 7.4 7.8 - 7.7 8.0 8.3 - 8.2 8.4 8.8 - 8.6 8.9 9.3 -
∆T 37 32 24 - 37 32 25 - 38 32 25 - 38 33 25 - 37 32 24 - 35 30 23 -
S/T 0.70 0.58 0.40 - 0.72 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
MBh 31.7 32.8 36.0 - 30.9 32.1 35.1 - 30.2 31.3 34.3 - 29.5 30.5 33.5 - 28.0 29.0 31.8 - 25.9 26.9 29.4 -
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 1.78 1.83 1.89 - 1.94 1.99 2.06 - 2.08 2.13 2.21 - 2.20 2.25 2.33 - 2.30 2.36 2.44 - 2.39 2.45 2.54 -
980
HI PR 209 224 237 - 234 252 266 - 266 286 302 - 303 326 345 - 341 367 388 - 377 406 428 -
Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 154 -
Amps 6.2 6.4 6.7 - 6.9 7.1 7.4 - 7.5 7.7 8.0 - 8.0 8.2 8.6 - 8.5 8.7 9.1 - 8.8 9.1 9.5 -
∆T 35 30 23 - 36 31 23 - 36 31 23 - 36 31 24 - 35 31 23 - 33 29 22 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
MBh 32.1 33.3 36.5 - 31.4 32.5 35.7 - 30.7 31.8 34.8 - 29.9 31.0 34.0 - 28.4 29.4 32.3 - 26.3 27.3 29.9 -
kW 1.81 1.86 1.92 - 1.97 2.02 2.09 - 2.11 2.16 2.24 - 2.23 2.29 2.37 - 2.34 2.40 2.48 - 2.43 2.49 2.58 -
1100
70
HI PR 212 228 241 - 238 256 271 - 271 291 308 - 308 332 350 - 347 373 394 - 383 413 436 -
Lo PR 108 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -
Amps 6.1 6.3 6.6 - 6.8 7.0 7.3 - 7.4 7.7 8.0 - 8.0 8.2 8.6 - 8.4 8.7 9.1 - 8.8 9.1 9.5 -
MBh 32.5 33.7 36.9 - 31.7 32.9 36.0 - 31.0 32.1 35.2
∆T 33 29 22 - 33 29 22 - 33 29 22 - 34 29 22 - 33 29 22 - 31 27 20 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
kW 1.82 1.86 1.93 - 1.98 2.02 2.10 - 2.12 2.17 2.25 - 2.24 2.30 2.38 - 2.35 2.40 2.49 - 2.44 2.50 2.59 -
HI PR 213 229 242 - 239 257 271 - 272 292 309 - 309 333 352 - 348 375 395 - 385 414 437 -
Lo PR 108 115 125 - 114 121 132 - 118 126 138 - 124 132 144 - 130 139 151 - 135 143 157 -
Amps 5.9
1260
MBh 32.2 33.2 35.9 38.5 31.5 32.4 35.1 37.6 30.7 31.6 34.2 36.7 30.0 30.8 33.4 35.8 28.5 29.3 31.7 34.0 26.4 27.1 29.4 31.5
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
∆T 43 39 32 22 43 40 33 23 43 40 33 23 44 40 33 23 43 40 32 22 40 37 30 21
kW 1.80 1.84 1.91 1.98 1.96 2.01 2.08 2.15 2.10 2.15 2.23 2.31 2.22 2.27 2.36 2.44 2.32 2.38 2.47 2.56 2.41 2.47 2.56 2.66
HI PR 211 227 239 250 236 254 269 280 269 289 306 319 306 330 348 363 345 371 392 408 381 410 433 451
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 134 142 155 165
Amps 6.3 6.5 6.7 7.1 7.0 7.2 7.5 7.8 7.6 7.8 8.1 8.5 8.1 8.3 8.7 9.1 8.5 8.8 9.2 9.6 8.9 9.2 9.6 10.0
980
MBh 32.7 33.7 36.4 39.1 31.9 32.9 35.6 38.2 31.2 32.1 34.7 37.3 30.4 31.3 33.9 36.4 28.9 29.7 32.2 34.6 26.8 27.6 29.8 32.0
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
∆T 41 37 31 21 41 38 31 21
kW 1.83 1.87 1.94 2.01 1.99 2.04 2.11 2.19 2.13 2.18 2.26 2.34 2.25 2.31 2.39 2.48 2.36 2.42 2.51 2.60 2.45 2.51 2.61 2.70
HI PR 214 231 244 254 241 259 273 285 274 294 311 324 312 335 354 369 351 377 398 415 387 417 440 459
Lo PR 109 116 126 134 115 122 133 142 119 127 139 148 125 133 146 155 131 140 153 162 136 145 158 168
Amps 6.2 6.4
1100
75
MBh 33.0 34.0 36.8 39.5 32.3 33.2 35.9 38.6 31.5 32.4 35.1 37.7 30.7 31.6 34.2 36.7 29.2 30.0 32.5 34.9 27.0 27.8 30.1 32.3
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.96 0.86 0.65 0.42 0.96 0.86 0.65 0.42
∆T 38 35 29 20 39 36 29 20 39 36 29 20 39 36 29 20 38 35 29 20 36 33 27 19
kW 1.83 1.88 1.95 2.02 1.99 2.04 2.12 2.19 2.14 2.19 2.27 2.35 2.26 2.32 2.40 2.49 2.37 2.43 2.51 2.61 2.46 2.52 2.61 2.71
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 313 336 355 370 352 378 400 417 388 418 441 460
Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 169
Amps 6.0 6.2 6.5 6.8 6.7 6.9 7.2 7.5 7.3 7.5 7.9 8.2 7.8 8.1 8.4 8.8 8.3 8.5 8.9 9.3 8.7 9.0 9.4 9.8
1260
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
14 www.daikincomfort.com SS-DX16TC
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 15
Expanded Cooling Dtaa — DX16TC0481A* / CA*F4860*6D*+MBVC2000**-1A*+TXV Low Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
37.4 31.3 31.9 34.1 36.5 29.7 30.3 32.4 34.7 27.5 28.1 30.0 32.1
6.5 6.8 6.8 7.0 7.3 7.6 7.4 7.6 8.0 8.3 7.9 8.2 8.5 8.9 8.4 8.6 9.0 9.4 8.8 9.1 9.5 9.9
49 48 46 39 47 48 46 40 45 46 45 39 42 43 42 37
6.8 7.2 7.1 7.3 7.6 7.9 7.7 7.9 8.3 8.6 8.2 8.5 8.9 9.3 8.7 9.0 9.4 9.8 9.1 9.4 9.8 10.2
∆T 48 46 40 32 48 46 40 32 48 46 40 32 49 47 41 32 48 46 40 32 45 43 37 30
S/T 0.87 0.82 0.67 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.94 0.76 0.57
MBh 32.8 33.5 35.8 38.3 32.0 32.7 35.0 37.4 31.3 31.9 34.1 36.5 30.5 31.2 33.3 35.6 29.0 29.6 31.6 33.8 26.8 27.4 29.3 31.3
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 1.82 1.86 1.93 2.00 1.98 2.02 2.10 2.17 2.12 2.17 2.25 2.33 2.24 2.30 2.38 2.47 2.35 2.40 2.49 2.58 2.44 2.50 2.59 2.68
980
Amps 6.3 6.5 6.8 7.1 7.0 7.2 7.6 7.9 7.6 7.9 8.2 8.6 8.2 8.4 8.8 9.2 8.6 8.9 9.3 9.7 9.0 9.3 9.7 10.1
HI PR 213 229 242 252 239 257 271 283 272 292 309 322 309 333 352 367 348 375 396 413 385 414 437 456
Lo PR 108 115 125 133 114 121 132 141 118 126 138 147 124 132 145 154 130 139 151 161 135 143 157 167
MBh 33.3 34.0 36.3 38.8 32.5 33.2 35.5 37.9 31.7 32.4 34.6 37.0 31.0 31.6 33.8 36.1 29.4 30.0 32.1 34.3 27.2 27.8 29.7 31.8
S/T 0.90 0.85 0.69 0.52 0.94 0.88 0.72 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.97 0.79 0.59
∆T 45 43 38 30 46 44 38 31 46 44 38 31 46 44 39 31 44 44 38 30 41 41 36 28
kW 1.85 1.89 1.96 2.03 2.01 2.06 2.13 2.21 2.15 2.20 2.28 2.37 2.28 2.33 2.42 2.51 2.38 2.44 2.53 2.63 2.48 2.54 2.63 2.73
HI PR 217 233 246 257 243 261 276 288 276 297 314 328 315 339 358 373 354 381 402 420 391 421 445 464
Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 127 135 147 157 133 141 154 164 137 146 159 170
Amps 6.3 6.5 6.8 7.1 7.0 7.2 7.5 7.9 7.6 7.8 8.2 8.5 8.1 8.4 8.8 9.2 8.6 8.9 9.3 9.7 9.0 9.3 9.7 10.1
1100
80
MBh 33.6 34.3 36.7 39.2 32.8 33.5 35.8 38.3 32.0 32.7 35.0
S/T 0.92 0.86 0.70 0.53 0.96 0.90 0.73 0.55 0.98 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 0.98 0.80 0.60 1.00 1.00 0.81 0.60
∆T 43 41 35 28 43 41 36 29 43 41 36 29 43 42 36 29 41 41 36 28 38 39 33 27
kW 1.85 1.90 1.96 2.03 2.01 2.06 2.14 2.21 2.16 2.21 2.29 2.37 2.28 2.34 2.42 2.51 2.39 2.45 2.54 2.63 2.48 2.54 2.64 2.74
HI PR 217 234 247 257 244 262 277 289 277 298 315 328 316 340 359 374 355 382 404 421 392 422 446 465
Lo PR 110 117 128 136 116 124 135 144 121 129 140 149 127 135 147 157 133 142 155 165 138 146 160 170
Amps 6.0 6.2
1260
MBh 33.3 34.0 35.6 38.0 32.6 33.2 34.8 37.1 31.8 32.4 33.9 36.2 31.0 31.6 33.1 35.3 29.5 30.0 31.5 33.6 27.3 27.8 29.1 31.1
S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.91 0.74
∆T 51 50 47 41 52 51 48 42 52 51 48 42 52 51 48 42 49 50 48 41 46 47 45 39
kW 1.83 1.88 1.95 2.02 1.99 2.04 2.12 2.19 2.14 2.19 2.27 2.35 2.26 2.32 2.40 2.49 2.37 2.43 2.51 2.61 2.46 2.52 2.61 2.71
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 312 336 355 370 352 378 399 417 388 418 441 460
Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
Amps 6.4 6.6 6.9 7.2 7.1 7.3 7.6 8.0 7.7 8.0 8.3 8.7 8.3 8.5 8.9 9.3 8.7 9.0 9.4 9.8 9.1 9.4 9.8 10.2
980
MBh 33.9 34.5 36.1 38.6 33.1 33.7 35.3 37.7 32.3 32.9 34.5 36.8 31.5 32.1 33.6 35.9 29.9 30.5 31.9 34.1 27.7 28.3 29.6 31.6
S/T 0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
∆T 48 48 45 39 49 48 46 39
kW 1.86 1.91 1.98 2.05 2.03 2.07 2.15 2.23 2.17 2.22 2.30 2.39 2.30 2.35 2.44 2.53 2.40 2.46 2.55 2.65 2.50 2.56 2.65 2.75
HI PR 219 235 249 259 245 264 279 291 279 300 317 331 318 342 361 377 358 385 406 424 395 425 449 468
Lo PR 111 118 129 137 117 125 136 145 122 129 141 151 128 136 148 158 134 143 156 166 139 147 161 171
Amps 6.4 6.5
1100
85
MBh 34.2 34.9 36.5 38.9 33.4 34.0 35.7 38.0 32.6 33.2 34.8 37.1 31.8 32.4 34.0 36.2 30.2 30.8 32.3 34.4 28.0 28.5 29.9 31.9
S/T 0.97 0.93 0.84 0.68 1.00 0.97 0.87 0.71 1.00 0.99 0.89 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.78
∆T 45 45 42 36 46 45 43 37 45 45 43 37 44 44 43 37 41 42 42 37 38 39 40 34
kW 1.87 1.91 1.98 2.05 2.03 2.08 2.16 2.23 2.18 2.23 2.31 2.40 2.30 2.36 2.45 2.54 2.41 2.47 2.56 2.66 2.51 2.57 2.66 2.76
HI PR 219 236 249 260 246 265 280 292 280 301 318 332 319 343 362 378 359 386 408 425 396 426 450 470
Lo PR 111 118 129 138 117 125 136 145 122 130 142 151 128 136 149 159 134 143 156 166 139 148 161 172
Amps 6.1 6.3 6.6 6.9 6.8 7.0 7.4 7.7 7.5 7.7 8.0 8.4 8.0 8.3 8.6 9.0 8.5 8.7 9.1 9.6 8.9 9.2 9.6 10.0
1260
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions Amps = outdoor unit amps (comp.+fan)
SS-DX16TC www.daikincomfort.com 15
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 16
Expanded Cooling Dtaa — DX16TC0601A* / CA*F4860*6D*+MBVC2000**-1A*+TXV High Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
- 52.0 53.9 59.0 - 49.4 51.2 56.1 - 45.7 47.4 51.9 -
21 19 16 11 21 19 16 11 20 19 15 11 19 18 14 10
11.9 12.4 - 12.9 13.3 13.9 - 14.1 14.5 15.2 - 15.2 15.7 16.4 - 16.1 16.6 17.4 - 16.9 17.4 18.2 -
12.3 12.8 13.5 13.3 13.7 14.3 15.0 14.5 14.9 15.6 16.4 15.6 16.1 16.8 17.5 16.5 17.0 17.8 18.6 17.3 17.8 18.6 19.4
∆T 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 19 16 12 - 17 15 11 -
S/T 0.68 0.57 0.39 - 0.71 0.59 0.41 - 0.72 0.60 0.42 - 0.75 0.62 0.43 - 0.78 0.65 0.45 - 0.78 0.65 0.45 -
MBh 53.4 55.4 60.7 - 52.2 54.1 59.2 - 50.9 52.8 57.8 - 49.7 51.5 56.4 - 47.2 48.9 53.6 - 43.7 45.3 49.7 -
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 3.38 3.46 3.59 - 3.69 3.78 3.92 - 3.96 4.06 4.21 - 4.20 4.31 4.47 - 4.41 4.52 4.69 - 4.58 4.70 4.88 -
1800
HI PR 218 235 248 - 245 263 278 - 278 300 316 - 317 341 360 - 357 384 405 - 394 424 448 -
Lo PR 103 109 119 - 109 116 126 - 113 120 131 - 119 126 138 - 124 132 144 - 129 137 149 -
Amps 11.8 12.2 12.8 - 13.2 13.6 14.2 - 14.4 14.8 15.5 - 15.4 15.9 16.6 - 16.3 16.8 17.5 - 17.1 17.6 18.4 -
∆T 18 15 12 - 18 15 12 - 18 15 12 - 18 16 12 - 18 15 12 - 17 14 11 -
S/T 0.71 0.59 0.41 - 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.65 0.45 - 0.80 0.67 0.47 - 0.81 0.68 0.47 -
MBh 54.2 56.2 61.6 - 53.0 54.9 60.1 - 51.7 53.6 58.7 - 50.4 52.3 57.3 - 47.9 49.7 54.4 - 44.4 46.0 50.4 -
kW 3.43 3.52 3.65 - 3.75 3.84 3.99 - 4.02 4.13 4.28 - 4.27 4.38 4.55 - 4.48 4.59 4.77 - 4.66 4.78 4.96 -
2000
70
HI PR 222 239 252 - 249 268 283 - 283 305 322 - 323 347 367 - 363 391 412 - 401 432 456 -
Lo PR 105 111 122 - 111 118 128 - 115 122 133 - 121 128 140 - 126 135 147 - 131 139 152 -
Amps 11.7 12.1 12.7 - 13.1 13.5 14.2 - 14.3 14.8 15.4 - 15.4 15.9 16.6 - 16.3 16.8 17.6 - 17.1 17.6 18.4 -
MBh 55.9 57.9 63.4 - 54.6 56.5 62.0 - 53.3 55.2 60.5
∆T 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 17 15 11 - 16 14 10 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.46 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
kW 3.46 3.55 3.68 - 3.78 3.88 4.02 - 4.06 4.17 4.32 - 4.31 4.42 4.59 - 4.52 4.64 4.81 - 4.70 4.82 5.01 -
HI PR 224 241 255 - 252 271 286 - 286 308 325 - 326 351 370 - 367 394 417 - 405 436 460 -
Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 153 -
Amps 11.5
2250
MBh 54.3 55.9 60.5 65.0 53.1 54.6 59.1 63.5 51.8 53.3 57.7 62.0 50.5 52.0 56.3 60.4 48.0 49.4 53.5 57.4 44.5 45.8 49.6 53.2
S/T 0.77 0.69 0.52 0.34 0.80 0.72 0.54 0.35 0.82 0.74 0.56 0.36 0.85 0.76 0.57 0.37 0.88 0.79 0.60 0.38 0.89 0.79 0.60 0.39
∆T 21 20 16 11 22 20 16 11 22 20 16 11 22 20 17 11 22 20 16 11 20 19 15 11
kW 3.41 3.49 3.63 3.76 3.72 3.82 3.96 4.11 4.00 4.10 4.25 4.42 4.24 4.35 4.51 4.69 4.45 4.56 4.74 4.92 4.63 4.75 4.93 5.12
HI PR 220 237 250 261 247 266 281 293 281 303 320 333 320 345 364 380 360 388 410 427 398 429 453 472
Lo PR 104 111 121 128 110 117 127 136 114 121 132 141 120 127 139 148 126 134 146 155 130 138 151 161
Amps 12.0 12.3 12.9 13.5 13.3 13.7 14.4 15.0 14.5 15.0 15.6 16.3 15.6 16.1 16.8 17.5 16.5 17.0 17.7 18.5 17.3 17.8 18.6 19.4
1800
MBh 55.1 56.8 61.5 66.0 53.9 55.5 60.0 64.4 52.6 54.1 58.6 62.9 51.3 52.8 57.2 61.4 48.7 50.2 54.3 58.3 45.1 46.5 50.3 54.0
S/T 0.80 0.72 0.54 0.35 0.83 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.79 0.60 0.38 0.91 0.82 0.62 0.40 0.92 0.82 0.62 0.40
∆T 20 19 15 11 21 19 16 11
kW 3.46 3.55 3.69 3.83 3.78 3.88 4.02 4.18 4.06 4.17 4.32 4.49 4.31 4.42 4.59 4.77 4.52 4.64 4.81 5.00 4.70 4.83 5.01 5.20
HI PR 224 241 255 266 252 271 286 298 286 308 325 339 326 351 370 386 367 395 417 435 405 436 460 480
Lo PR 106 112 123 131 112 119 130 138 116 123 135 144 122 130 142 151 128 136 148 158 132 141 153 163
Amps 11.9
2000
75
MBh 56.8 58.5 63.3 67.9 55.5 57.1 61.8 66.4 54.2 55.8 60.4 64.8 52.8 54.4 58.9 63.2 50.2 51.7 55.9 60.0 46.5 47.9 51.8 55.6
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.61 0.39 0.92 0.83 0.62 0.40 0.96 0.86 0.65 0.42 0.97 0.86 0.65 0.42
∆T 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 20 18 15 10 18 17 14 10
kW 3.50 3.59 3.72 3.86 3.82 3.92 4.06 4.22 4.10 4.21 4.37 4.53 4.35 4.46 4.63 4.81 4.57 4.68 4.86 5.05 4.75 4.87 5.06 5.25
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329 354 374 390 370 399 421 439 409 440 465 485
Lo PR 107 114 124 132 113 120 131 139 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165
Amps 11.6 12.0 12.6 13.2 13.0 13.5 14.1 14.8 14.3 14.7 15.4 16.1 15.4 15.8 16.6 17.4 16.3 16.8 17.6 18.4 17.1 17.6 18.4 19.3
2250
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
16 www.daikincomfort.com SS-DX16TC
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 17
Expanded Cooling Dtaa — DX16TC0601A* / CA*F4860*6D*+MBVC2000**-1A*+TXV High Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
64.3 53.8 55.0 58.7 62.8 51.1 52.2 55.8 59.6 47.3 48.4 51.7 55.2
12.2 12.8 13.4 13.2 13.6 14.3 14.9 14.4 14.9 15.6 16.3 15.5 16.0 16.8 17.6 16.5 17.0 17.8 18.6 17.3 17.8 18.6 19.5
25 24 23 20 24 24 23 20 23 24 23 20 21 22 21 18
12.6 13.2 13.8 13.6 14.0 14.7 15.3 14.8 15.3 16.0 16.7 15.9 16.4 17.2 18.0 16.9 17.4 18.2 19.0 17.7 18.2 19.0 19.9
∆T 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 24 23 20 16 23 22 19 15
S/T 0.85 0.80 0.65 0.48 0.88 0.83 0.67 0.50 0.90 0.85 0.69 0.51 0.93 0.87 0.71 0.53 0.97 0.91 0.74 0.55 0.97 0.91 0.74 0.56
MBh 55.3 56.5 60.4 64.5 54.0 55.2 59.0 63.0 52.7 53.9 57.5 61.5 51.4 52.6 56.1 60.0 48.9 49.9 53.3 57.0 45.3 46.2 49.4 52.8
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 3.44 3.53 3.66 3.80 3.76 3.85 4.00 4.15 4.04 4.14 4.30 4.46 4.28 4.39 4.56 4.73 4.49 4.61 4.78 4.97 4.67 4.79 4.97 5.17
1800
Amps 12.1 12.5 13.1 13.7 13.5 13.9 14.5 15.2 14.7 15.1 15.8 16.5 15.8 16.2 17.0 17.7 16.7 17.2 17.9 18.7 17.5 18.0 18.8 19.6
HI PR 223 240 253 264 250 269 284 296 284 306 323 337 324 348 368 384 364 392 414 431 402 433 457 477
Lo PR 105 112 122 130 111 118 129 137 115 123 134 143 121 129 141 150 127 135 147 157 131 140 152 162
MBh 56.1 57.4 61.3 65.5 54.8 56.0 59.9 64.0 53.5 54.7 58.4 62.5 52.2 53.4 57.0 60.9 49.6 50.7 54.2 57.9 45.9 46.9 50.2 53.6
S/T 0.88 0.83 0.67 0.50 0.91 0.86 0.70 0.52 0.94 0.88 0.71 0.53 0.97 0.91 0.74 0.55 1.00 0.94 0.76 0.57 1.00 0.95 0.77 0.58
∆T 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 23 22 19 15 21 20 18 14
kW 3.50 3.59 3.72 3.86 3.82 3.92 4.06 4.22 4.10 4.21 4.37 4.53 4.35 4.46 4.63 4.81 4.57 4.68 4.86 5.05 4.75 4.87 5.06 5.25
HI PR 226 244 257 268 254 273 289 301 289 311 328 343 329 354 374 390 370 399 421 439 409 440 465 485
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 133 142 155 165
Amps 12.0 12.4 13.0 13.6 13.4 13.9 14.5 15.2 14.7 15.1 15.8 16.5 15.8 16.2 17.0 17.7 16.7 17.2 18.0 18.8 17.5 18.0 18.8 19.7
2000
80
MBh 57.8 59.1 63.1 67.5 56.5 57.7 61.6 65.9 55.1 56.3 60.2
S/T 0.92 0.87 0.70 0.53 0.96 0.90 0.73 0.55 1.00 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 1.00 0.80 0.60 1.00 1.00 0.81 0.60
∆T 22 21 18 15 22 21 18 15 23 21 18 15 22 21 19 15 21 21 18 15 19 20 17 14
kW 3.53 3.62 3.76 3.90 3.86 3.95 4.10 4.26 4.14 4.25 4.41 4.58 4.40 4.51 4.68 4.86 4.61 4.73 4.91 5.10 4.80 4.92 5.11 5.30
HI PR 229 246 260 271 257 276 292 304 292 314 332 346 333 358 378 394 374 403 425 443 413 445 470 490
Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
Amps 11.8
2250
MBh 56.3 57.3 60.1 64.1 54.9 56.0 58.7 62.6 53.6 54.7 57.3 61.1 52.3 53.3 55.9 59.6 49.7 50.7 53.1 56.6 46.0 46.9 49.2 52.4
S/T 0.89 0.86 0.77 0.63 0.92 0.89 0.80 0.65 0.95 0.91 0.82 0.67 0.98 0.94 0.85 0.69 1.00 0.98 0.88 0.72 1.00 0.99 0.89 0.72
∆T 26 25 24 21 26 25 24 21 26 25 24 21 26 26 24 21 25 25 24 21 24 24 22 19
kW 3.47 3.56 3.70 3.84 3.79 3.89 4.04 4.19 4.07 4.18 4.34 4.50 4.32 4.43 4.60 4.78 4.53 4.65 4.83 5.01 4.72 4.84 5.02 5.22
HI PR 225 242 256 267 252 272 287 299 287 309 326 340 327 352 371 387 368 396 418 436 406 437 462 482
Lo PR 106 113 123 131 112 119 130 139 116 124 135 144 122 130 142 151 128 136 149 158 133 141 154 164
Amps 12.2 12.6 13.2 13.8 13.6 14.1 14.7 15.4 14.9 15.3 16.0 16.7 15.9 16.4 17.2 17.9 16.9 17.4 18.1 18.9 17.7 18.2 19.0 19.8
1800
MBh 57.1 58.2 61.0 65.0 55.8 56.9 59.6 63.5 54.5 55.5 58.1 62.0 53.1 54.2 56.7 60.5 50.5 51.4 53.9 57.5 46.7 47.7 49.9 53.2
S/T 0.92 0.89 0.80 0.65 0.96 0.92 0.83 0.68 0.98 0.95 0.85 0.69 1.00 0.98 0.88 0.72 1.00 1.00 0.91 0.74 1.00 1.00 0.92 0.75
∆T 24 24 23 19 25 24 23 20
kW 3.53 3.62 3.76 3.90 3.86 3.95 4.10 4.26 4.14 4.25 4.41 4.58 4.40 4.51 4.68 4.86 4.61 4.73 4.91 5.10 4.80 4.92 5.11 5.30
HI PR 229 246 260 271 257 276 292 304 292 314 332 346 333 358 378 394 374 403 425 443 413 445 470 490
Lo PR 108 115 125 133 114 121 132 141 118 126 137 146 124 132 144 154 130 139 151 161 135 143 157 167
Amps 12.2
2000
85
MBh 58.8 60.0 62.8 67.0 57.5 58.6 61.3 65.4 56.1 57.2 59.9 63.9 54.7 55.8 58.4 62.3 52.0 53.0 55.5 59.2 48.2 49.1 51.4 54.8
S/T 0.97 0.93 0.84 0.68 1.00 0.97 0.87 0.71 1.00 0.99 0.90 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.78
∆T 23 23 22 19 23 23 22 19 23 23 22 19 22 23 22 19 21 22 22 19 20 20 20 18
kW 3.56 3.65 3.79 3.94 3.89 3.99 4.14 4.30 4.18 4.29 4.45 4.62 4.44 4.55 4.72 4.91 4.65 4.77 4.96 5.15 4.84 4.97 5.16 5.35
HI PR 231 249 263 274 259 279 295 307 295 317 335 349 336 361 382 398 378 407 429 448 417 449 474 495
Lo PR 109 116 126 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
Amps 11.9 12.3 12.9 13.5 13.4 13.8 14.4 15.1 14.6 15.1 15.8 16.5 15.7 16.2 17.0 17.8 16.7 17.2 18.0 18.8 17.5 18.0 18.8 19.7
2250
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions Amps = outdoor unit amps (comp.+fan)
SS-DX16TC www.daikincomfort.com 17
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 18
Expanded Cooling Dtaa — DX16TC0601A* / CA*F4860*6D*+MBVC2000**-1A*+TXV Low Stage
Outdoor Ambient Temperature
- 36.6 38.0 41.6 - 34.8 36.1 39.5 - 32.2 33.4 36.6 -
Entering Indoor Wet Bulb Temperature
50 46 38 26 50 46 38 26 50 46 37 26 46 43 35 24
8.3 8.6 9.0 9.4 9.1 9.4 9.8 10.3 9.8 10.1 10.5 11.0 10.4 10.7 11.2 11.7 10.9 11.2 11.7 12.2
7.7 - 8.0 8.3 8.7 - 8.8 9.0 9.5 - 9.4 9.7 10.2 - 10.0 10.3 10.8 - 10.5 10.8 11.3 -
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
∆T 45 39 29 - 45 39 30 - 45 39 30 - 46 40 30 - 45 39 30 - 42 37 28 -
S/T 0.70 0.58 0.40 - 0.72 0.61 0.42 - 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.80 0.66 0.46 - 0.80 0.67 0.46 -
MBh 38.4 39.8 43.6 - 37.5 38.9 42.6 - 36.6 38.0 41.6 - 35.7 37.0 40.6 - 33.9 35.2 38.5 - 31.4 32.6 35.7 -
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 2.18 2.23 2.31 - 2.37 2.43 2.52 - 2.54 2.60 2.70 - 2.69 2.76 2.86 - 2.82 2.89 3.00 - 2.93 3.00 3.12 -
1200
HI PR 209 224 237 - 234 252 266 - 266 286 302 - 303 326 345 - 341 367 388 - 377 406 428 -
Lo PR 106 112 123 - 112 119 130 - 116 123 135 - 122 130 142 - 128 136 148 - 132 141 154 -
Amps 7.6 7.8 8.1 - 8.4 8.7 9.0 - 9.1 9.4 9.8 - 9.8 10.1 10.5 - 10.4 10.7 11.1 - 10.8 11.2 11.6 -
∆T 43 37 28 - 43 37 28 - 43 37 28 - 43 38 29 - 43 37 28 - 40 35 26 -
S/T 0.73 0.61 0.42 - 0.75 0.63 0.43 - 0.77 0.64 0.45 - 0.80 0.66 0.46 - 0.83 0.69 0.48 - 0.83 0.70 0.48 -
MBh 39.0 40.4 44.3 - 38.1 39.5 43.2 - 37.2 38.5 42.2 - 36.3 37.6 41.2 - 34.5 35.7 39.1 - 31.9 33.1 36.2 -
kW 2.21 2.27 2.35 - 2.41 2.47 2.56 - 2.58 2.65 2.74 - 2.74 2.80 2.91 - 2.87 2.94 3.05 - 2.98 3.05 3.17 -
1400
70
HI PR 212 228 241 - 238 256 271 - 271 291 308 - 308 332 350 - 347 373 394 - 383 413 436 -
Lo PR 108 114 125 - 114 121 132 - 118 126 137 - 124 132 144 - 130 138 151 - 134 143 156 -
Amps 7.4 7.6 8.0 - 8.2 8.5 8.9 - 9.0 9.3 9.7 - 9.7 10.0 10.4 - 10.2 10.6 11.0 - 10.7 11.1 11.5 -
MBh 39.4 40.8 44.7 - 38.5 39.9 43.7 - 37.5 38.9 42.6
∆T 40 35 26 - 40 35 27 - 40 35 27 - 41 35 27 - 40 35 26 - 38 33 25 -
S/T 0.74 0.62 0.43 - 0.77 0.64 0.44 - 0.79 0.66 0.45 - 0.81 0.68 0.47 - 0.84 0.70 0.49 - 0.85 0.71 0.49 -
kW 2.22 2.27 2.35 - 2.42 2.47 2.57 - 2.59 2.65 2.75 - 2.74 2.81 2.92 - 2.87 2.95 3.06 - 2.99 3.06 3.18 -
HI PR 213 229 242 - 239 257 271 - 272 292 309 - 309 333 352 - 348 375 395 - 385 414 437 -
Lo PR 108 115 125 - 114 121 132 - 118 126 138 - 124 132 144 - 130 139 151 - 135 143 157 -
Amps 7.1 7.4
1575
MBh 39.1 40.2 43.5 46.7 38.1 39.3 42.5 45.6 37.2 38.3 41.5 44.5 36.3 37.4 40.5 43.5 34.5 35.5 38.5 41.3 32.0 32.9 35.6 38.2
S/T 0.79 0.71 0.54 0.35 0.82 0.74 0.56 0.36 0.84 0.76 0.57 0.37 0.87 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.91 0.82 0.62 0.40
∆T 52 48 39 27 53 48 40 27 53 48 40 27 53 49 40 28 52 48 39 27 49 45 37 25
kW 2.20 2.25 2.33 2.42 2.39 2.45 2.54 2.64 2.57 2.63 2.73 2.83 2.72 2.79 2.89 3.00 2.85 2.92 3.03 3.14 2.96 3.03 3.15 3.26
HI PR 211 227 239 250 236 254 269 280 269 289 306 319 306 330 348 363 345 371 392 408 381 410 433 451
Lo PR 107 114 124 132 113 120 131 140 117 125 136 145 123 131 143 152 129 137 150 160 134 142 155 165
Amps 7.6 7.9 8.2 8.6 8.5 8.8 9.1 9.6 9.2 9.5 9.9 10.4 9.9 10.2 10.7 11.1 10.5 10.8 11.3 11.8 11.0 11.3 11.8 12.3
1200
MBh 39.7 40.8 44.2 47.4 38.7 39.9 43.2 46.3 37.8 38.9 42.1 45.2 36.9 38.0 41.1 44.1 35.0 36.1 39.1 41.9 32.5 33.4 36.2 38.8
S/T 0.82 0.74 0.56 0.36 0.85 0.76 0.58 0.37 0.88 0.78 0.59 0.38 0.90 0.81 0.61 0.39 0.94 0.84 0.64 0.41 0.95 0.85 0.64 0.41
∆T 49 45 37 26 50 46 38 26
kW 2.23 2.29 2.37 2.46 2.43 2.49 2.58 2.68 2.61 2.67 2.77 2.87 2.76 2.83 2.94 3.05 2.89 2.97 3.08 3.19 3.01 3.08 3.20 3.32
HI PR 214 231 244 254 241 259 273 285 274 294 311 324 312 335 354 369 351 377 398 415 387 417 440 459
Lo PR 109 116 126 134 115 122 133 142 119 127 139 148 125 133 146 155 131 140 153 162 136 145 158 168
Amps 7.5 7.7 8.1 8.5
1400
75
MBh 40.0 41.2 44.6 47.9 39.1 40.3 43.6 46.8 38.2 39.3 42.6 45.7 37.3 38.4 41.5 44.6 35.4 36.4 39.4 42.3 32.8 33.8 36.5 39.2
S/T 0.84 0.75 0.57 0.37 0.87 0.78 0.59 0.38 0.89 0.80 0.60 0.39 0.92 0.82 0.62 0.40 0.96 0.86 0.65 0.42 0.96 0.86 0.65 0.42
∆T 46 43 35 24 47 43 35 24 47 43 35 24 47 43 36 25 46 43 35 24 43 40 33 23
kW 2.24 2.29 2.38 2.46 2.44 2.50 2.59 2.69 2.61 2.68 2.78 2.88 2.77 2.84 2.94 3.05 2.90 2.97 3.08 3.20 3.02 3.09 3.21 3.33
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 313 336 355 370 352 378 400 417 388 418 441 460
Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 169
Amps 7.2 7.5 7.8 8.2 8.1 8.4 8.8 9.2 8.9 9.1 9.6 10.0 9.5 9.8 10.3 10.8 10.1 10.4 10.9 11.4 10.6 10.9 11.4 12.0
1575
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects ACCA (TVA) condions Amps = outdoor unit amps (comp.+fan)
18 www.daikincomfort.com SS-DX16TC
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 19
Expanded Cooling Dtaa — DX16TC0601A* / CA*F4860*6D*+MBVC2000**-1A*+TXV Low Stage
Outdoor Ambient Temperature
Entering Indoor Wet Bulb Temperature
65ºF 75ºF 85ºF 95ºF 105ºF 115ºF
45.4 37.9 38.7 41.4 44.2 36.0 36.8 39.3 42.0 33.4 34.1 36.4 38.9
7.6 7.9 8.3 8.2 8.5 8.9 9.3 9.0 9.3 9.7 10.1 9.7 10.0 10.4 10.9 10.2 10.6 11.0 11.6 10.7 11.1 11.6 12.1
59 58 55 48 58 59 56 48 55 56 55 47 51 52 51 44
7.9 8.3 8.7 8.5 8.8 9.2 9.6 9.3 9.6 10.0 10.5 10.0 10.3 10.8 11.3 10.6 10.9 11.4 11.9 11.1 11.4 11.9 12.5
∆T 58 56 48 39 59 56 49 39 59 56 49 39 59 57 49 39 58 56 49 39 54 52 45 36
S/T 0.87 0.82 0.67 0.50 0.90 0.85 0.69 0.52 0.93 0.87 0.71 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.94 0.76 0.57
MBh 39.8 40.6 43.4 46.4 38.8 39.7 42.4 45.3 37.9 38.7 41.4 44.2 37.0 37.8 40.4 43.2 35.1 35.9 38.3 41.0 32.5 33.3 35.5 38.0
IDB Airflow 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71
kW 2.22 2.27 2.35 2.44 2.42 2.47 2.57 2.66 2.59 2.65 2.75 2.85 2.74 2.81 2.92 3.03 2.87 2.95 3.06 3.17 2.99 3.06 3.18 3.30
1200
Amps 7.7 8.0 8.3 8.7 8.6 8.9 9.3 9.7 9.4 9.6 10.1 10.5 10.0 10.3 10.8 11.3 10.6 10.9 11.4 11.9 11.1 11.4 11.9 12.4
HI PR 213 229 242 252 239 257 271 283 272 292 309 322 309 333 352 367 348 375 396 413 385 414 437 456
Lo PR 108 115 125 133 114 121 132 141 118 126 138 147 124 132 145 154 130 139 151 161 135 143 157 167
MBh 40.4 41.2 44.1 47.1 39.4 40.3 43.0 46.0 38.5 39.3 42.0 44.9 37.5 38.4 41.0 43.8 35.7 36.4 38.9 41.6 33.0 33.8 36.1 38.6
S/T 0.90 0.85 0.69 0.52 0.94 0.88 0.72 0.53 0.96 0.90 0.73 0.55 0.99 0.93 0.76 0.57 1.00 0.97 0.79 0.59 1.00 0.97 0.79 0.59
∆T 55 53 46 37 56 53 46 37 56 53 46 37 56 54 47 37 54 53 46 37 50 50 43 34
kW 2.25 2.31 2.39 2.48 2.45 2.51 2.61 2.70 2.63 2.70 2.80 2.90 2.79 2.86 2.96 3.07 2.92 2.99 3.11 3.22 3.04 3.11 3.23 3.35
HI PR 217 233 246 257 243 261 276 288 276 297 314 328 315 339 358 373 354 381 402 420 391 421 445 464
Lo PR 110 117 127 136 116 123 135 143 120 128 140 149 127 135 147 157 133 141 154 164 137 146 159 170
Amps 7.5 7.7 8.1 8.5 8.3 8.6 9.0 9.4 9.1 9.4 9.8 10.3 9.8 10.1 10.5 11.0 10.4 10.7 11.2 11.7 10.9 11.2 11.7 12.2
1400
80
MBh 40.8 41.6 44.5 47.6 39.8 40.7 43.5 46.5 38.9 39.7 42.4
S/T 0.92 0.86 0.70 0.53 0.96 0.90 0.73 0.55 0.98 0.92 0.75 0.56 1.00 0.95 0.77 0.58 1.00 0.98 0.80 0.60 1.00 1.00 0.81 0.60
∆T 52 49 43 34 52 50 43 35 52 50 44 35 52 50 44 35 49 50 43 35 46 47 40 32
kW 2.26 2.31 2.40 2.49 2.46 2.52 2.61 2.71 2.64 2.70 2.80 2.91 2.80 2.87 2.97 3.08 2.93 3.00 3.11 3.23 3.04 3.12 3.24 3.36
HI PR 217 234 247 257 244 262 277 289 277 298 315 328 316 340 359 374 355 382 404 421 392 422 446 465
Lo PR 110 117 128 136 116 124 135 144 121 129 140 149 127 135 147 157 133 142 155 165 138 146 160 170
Amps 7.3
1575
MBh 40.4 41.2 43.2 46.1 39.5 40.3 42.2 45.0 38.6 39.3 41.2 43.9 37.6 38.4 40.2 42.9 35.7 36.4 38.2 40.7 33.1 33.7 35.3 37.7
S/T 0.91 0.88 0.80 0.65 0.95 0.91 0.82 0.67 0.97 0.94 0.85 0.69 1.00 0.97 0.87 0.71 1.00 1.00 0.91 0.74 1.00 1.00 0.91 0.74
∆T 62 61 57 50 63 62 58 50 63 62 58 50 63 62 59 51 60 61 58 50 55 56 54 47
kW 2.24 2.29 2.38 2.46 2.44 2.50 2.59 2.69 2.61 2.68 2.78 2.88 2.77 2.84 2.94 3.05 2.90 2.97 3.08 3.20 3.02 3.09 3.21 3.33
HI PR 215 231 244 255 241 260 274 286 274 295 312 325 312 336 355 370 352 378 399 417 388 418 441 460
Lo PR 109 116 127 135 115 122 134 142 120 127 139 148 126 134 146 155 132 140 153 163 136 145 158 168
Amps 7.8 8.1 8.4 8.8 8.7 9.0 9.4 9.8 9.5 9.7 10.2 10.6 10.1 10.4 10.9 11.4 10.7 11.0 11.5 12.0 11.2 11.5 12.0 12.6
1200
MBh 41.1 41.9 43.8 46.8 40.1 40.9 42.8 45.7 39.2 39.9 41.8 44.6 38.2 38.9 40.8 43.5 36.3 37.0 38.7 41.3 33.6 34.3 35.9 38.3
S/T 0.95 0.91 0.83 0.67 0.98 0.95 0.86 0.69 1.00 0.97 0.88 0.71 1.00 1.00 0.91 0.73 1.00 1.00 0.94 0.76 1.00 1.00 0.95 0.77
∆T 59 58 55 47 59 58 55 48
kW 2.27 2.33 2.41 2.50 2.48 2.54 2.63 2.73 2.66 2.72 2.82 2.93 2.81 2.88 2.99 3.10 2.95 3.02 3.13 3.25 3.06 3.14 3.26 3.38
HI PR 219 235 249 259 245 264 279 291 279 300 317 331 318 342 361 377 358 385 406 424 395 425 449 468
Lo PR 111 118 129 137 117 125 136 145 122 129 141 151 128 136 148 158 134 143 156 166 139 147 161 171
Amps 7.7
1400
85
MBh 41.5 42.3 44.3 47.2 40.5 41.3 43.2 46.1 39.5 40.3 42.2 45.0 38.6 39.3 41.2 43.9 36.6 37.4 39.1 41.7 33.9 34.6 36.2 38.7
S/T 0.97 0.93 0.84 0.68 1.00 0.97 0.87 0.71 1.00 0.99 0.89 0.73 1.00 1.00 0.92 0.75 1.00 1.00 0.96 0.78 1.00 1.00 0.97 0.78
∆T 55 54 51 44 56 55 52 45 54 55 52 45 53 54 52 45 50 51 51 45 47 47 48 42
kW 2.28 2.34 2.42 2.51 2.48 2.55 2.64 2.74 2.66 2.73 2.83 2.94 2.82 2.89 3.00 3.11 2.96 3.03 3.14 3.26 3.07 3.15 3.27 3.39
HI PR 219 236 249 260 246 265 280 292 280 301 318 332 319 343 362 378 359 386 408 425 396 426 450 470
Lo PR 111 118 129 138 117 125 136 145 122 130 142 151 128 136 149 159 134 143 156 166 139 148 161 172
Amps 7.4 7.7 8.0 8.4 8.3 8.6 9.0 9.4 9.1 9.4 9.8 10.3 9.8 10.1 10.5 11.0 10.4 10.7 11.2 11.7 10.9 11.2 11.7 12.2
1575
IDB = Entering Indoor Dry Bulb Temperature Shaded area reects AHRI (TVA) condions Amps = outdoor unit amps (comp.+fan)
SS-DX16TC www.daikincomfort.com 19
High and low pressures are measured at the liquid and sucon service valves. kW = Total system power
Page 20
AHRI Ratings AHRI Ra tings
Outdoor
Unit
DX16TC
0241A*
Indoor Units Cooling Ratings
Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³
AVPTC30C14A* 23,000 16,800 16.0 12.5 830 6524250
CA*F3636*6D*+MBVC1200**-1A*+TXV 24,000 17,600 16.0 13.0 820 6524253
CA*F3636*6D*+TXV D*80VC0604B*A* 24,000 17,600 16.0 13.0 820 6524295
CA*F3636*6D*+TXV DD80VC0603B*A* 24,000 17,600 16.0 13.0 810 6712128
CA*F3636*6D*+TXV D*96VE0302BNA* 24,000 17,600 16.0 13.0 800 7368387
CA*F3636*6D*+TXV D*96VE0402BNA* 24,000 17,600 16.0 13.0 850 7368390
CA*F3636*6D*+TXV D*96VE0603BNA* 24,000 17,600 16.0 13.0 800 7368393
CA*F3636*6D*+TXV D*96VE0803BNA* 24,000 17,600 16.0 13.0 800 7368396
CA*F3636*6D*+TXV D*96VC0403BNA* 24,000 17,600 16.0 13.0 810 7369821
CA*F3636*6D*+TXV D*96VC0603BNA* 24,000 17,600 16.0 13.0 815 7369826
CA*F3636*6D*+TXV D*96VC0803BNA* 24,000 17,600 16.0 13.0 810 7369831
CA*F3636*6D*+TXV D*97MC0603BNA* 24,000 17,600 16.0 13.0 815 7369899
CA*F3636*6D*+TXV D*97MC0803BNA* 24,000 17,600 16.0 13.0 810 7369904
CA*F3642*6D*+TXV D*80VC0604B*A* 24,000 17,600 16.0 13.0 820 6524296
CAPT3131*4A* D*96VC0403BNA* 23,400 17,100 15.5 12.5 810 7369822
CAPT3131*4A* D*96VC0603BNA* 23,400 17,100 15.5 12.5 815 7369827
CAPT3131*4A* D*96VC0803BNA* 23,400 17,100 15.5 12.5 810 7369832
CAPT3131*4A* D*97MC0603BNA* 23,400 17,100 15.5 12.5 815 7369900
CAPT3131*4A* D*97MC0803BNA* 23,400 17,100 15.5 12.5 810 7369905
CAPT3743*4A* D*96VE0302BNA* 24,200 17,700 16.0 13.0 800 7368388
CAPT3743*4A* D*96VE0402BNA* 24,200 17,700 16.0 13.0 850 7368391
CAPT3743*4A* D*96VE0603BNA* 24,200 17,700 16.0 13.0 800 7368394
CAPT3743*4A* D*96VE0803BNA* 24,200 17,700 16.0 13.0 800 7368397
CHPF3636B6C*+MBVC1200**-1A*+TXV 24,000 17,600 16.0 13.0 820 6524256
CHPF3636B6C*+TXV D*80VC0604B*A* 24,000 17,600 16.0 13.0 820 6524297
CHPF3636B6C*+TXV D*96VE0302BNA* 24,000 17,600 16.0 13.0 800 7368389
CHPF3636B6C*+TXV D*96VE0402BNA* 24,000 17,600 16.0 13.0 850 7368392
CHPF3636B6C*+TXV D*96VE0603BNA* 24,000 17,600 16.0 13.0 800 7368395
CHPF3636B6C*+TXV D*96VE0803BNA* 24,000 17,600 16.0 13.0 800 7368398
CHPF3636B6C*+TXV D*96VC0403BNA* 24,000 17,600 16.0 13.0 810 7369823
CHPF3636B6C*+TXV D*96VC0603BNA* 24,000 17,600 16.0 13.0 815 7369828
CHPF3636B6C*+TXV D*96VC0803BNA* 24,000 17,600 16.0 13.0 810 7369833
CHPF3636B6C*+TXV D*97MC0603BNA* 24,000 17,600 16.0 13.0 815 7369901
CHPF3636B6C*+TXV D*97MC0803BNA* 24,000 17,600 16.0 13.0 810 7369906
CSCF3036N6D*+TXV D*80VC0604B*A* 24,000 17,600 16.0 13.0 820 6524298
CSCF3036N6D*+TXV D*96VC0403BNA* 24,000 17,600 15.5 12.5 810 7369824
CSCF3036N6D*+TXV D*96VC0603BNA* 24,000 17,600 15.5 12.5 815 7369829
CSCF3036N6D*+TXV D*96VC0803BNA* 24,000 17,600 15.5 12.5 810 7369834
CSCF3036N6D*+TXV D*97MC0603BNA* 24,000 17,600 15.5 12.5 815 7369902
CSCF3036N6D*+TXV D*97MC0803BNA* 24,000 17,600 15.5 12.5 810 7369907
CSCF3642N6D*+TXV D*80VC0604B*A* 24,000 17,600 16.0 13.0 820 6524299
CSCF3642N6D*+TXV D*96VC0403BNA* 24,000 17,600 16.0 13.0 810 7369825
CSCF3642N6D*+TXV D*96VC0603BNA* 24,000 17,600 16.0 13.0 815 7369830
CSCF3642N6D*+TXV D*96VC0803BNA* 24,000 17,600 16.0 13.0 810 7369835
CSCF3642N6D*+TXV D*97MC0603BNA* 24,000 17,600 16.0 13.0 815 7369903
CSCF3642N6D*+TXV D*97MC0803BNA* 24,000 17,600 16.0 13.0 810 7369908
DV30PTCC14A* 23,000 16,800 16.0 12.5 830 6524251
CFM AHRI #
See Notes on Page 24.
20 www.daikincomfort.com SS-DX16TC
20 www.daikincomfort.com SS-DX16TC
Page 21
Outdoor
Unit
DX16TC
0361A*
Indoor Units Cooling Ratings
Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³
AVPTC42D14A* 35,000 25,200 16.0 12.2 1,200 6524335
AVPTC48C14A* 34,400 24,800 15.0 12.2 1,100 7080493
AVPTC48D14A* 36,000 25,800 16.0 12.5 1,200 6524337
CA*F3642*6D*+MBVC1600**-1A*+TXV 35,000 25,200 16.0 12.5 1,200 6524338
CA*F3642*6D*+TXV D*80VC0805C*A* 35,000 25,200 16.0 12.5 1,190 6524459
CA*F3642*6D*+TXV DD80VC0603B*A* 34,000 24,400 16.0 12.5 1,190 6524552
CA*F3642*6D*+TXV DD80VC0805C*A* 35,000 25,200 16.0 12.5 1,190 6524553
CA*F3743*6D*+MBVC1600**-1A*+TXV 35,000 25,200 16.0 12.5 1,100 6524340
CA*F3743*6D*+TXV D*80VC0604B*A* 34,000 24,400 16.0 12.5 1,220 6524453
CA*F3743*6D*+TXV D*80VC0805C*A* 34,000 24,400 16.0 12.5 1,190 6524460
CA*F3743*6D*+TXV DD80VC0805C*A* 34,000 24,400 16.0 12.5 1,190 6524554
CA*F3743*6D*+TXV D*96VE1004CNA* 34,800 25,000 16.0 12.3 1,150 7368408
CA*F3743*6D*+TXV D*96VE1205DNA* 34,800 25,000 15.5 12.3 1,250 7368413
CA*F3743*6D*+TXV D*96VC1205DNA* 34,200 24,600 15.5 12.2 1,115 7369863
CA*F3743*6D*+TXV D*97MC1205DNA* 34,200 24,600 15.5 12.2 1,115 7369931
CA*F3743*6D*+TXV D*80VC1005C*A* 35,000 25,200 16.0 12.5 1,200 8005817
CA*F4860*6D*+TXV D*80VC0604B*A* 34,600 24,800 16.0 12.5 1,220 6524454
CA*F4860*6D*+TXV D*80VC0805C*A* 35,000 25,200 16.0 12.5 1,190 6524461
CA*F4860*6D*+TXV DD80VC0805C*A* 35,000 25,200 16.0 12.5 1,190 6524555
CA*F4961*6D*+TXV D*96VE1004CNA* 35,000 25,200 16.0 12.5 1,150 7368409
CA*F4961*6D*+TXV D*96VE1205DNA* 35,000 25,200 16.0 12.2 1,250 7368414
CA*F4961*6D*+TXV D*96VC0804CNA* 35,000 25,200 16.0 13.0 1,125 7369852
CA*F4961*6D*+TXV D*96VC1205DNA* 35,000 25,200 16.0 13.0 1,115 7369864
CA*F4961*6D*+TXV D*97MC0804CNA* 35,000 25,200 16.0 13.0 1,125 7369920
CA*F4961*6D*+TXV D*97MC1005CNA* 35,000 25,200 16.0 13.0 1,200 7369926
CA*F4961*6D*+TXV D*97MC1205DNA* 35,000 25,200 16.0 13.0 1,115 7369932
CAPT3743*4A* D*96VC1205DNA* 34,200 24,600 15.5 12.2 1,115 7369865
CAPT3743*4A* D*97MC1205DNA* 34,200 24,600 15.5 12.2 1,115 7369933
CHPF3642C6C*+MBVC1600**-1A*+TXV 34,600 24,800 16.0 12.5 1,200 6524342
CHPF3642C6C*+TXV D*80VC0805C*A* 34,600 24,800 16.0 12.5 1,190 6524462
CHPF3642D6C*+MBVC2000**-1A*+TXV 35,000 25,200 16.0 12.8 1,200 6524343
CHPF3743C6B*+MBVC1600**-1A*+TXV 34,600 24,800 16.0 12.5 1,200 6524345
CHPF3743C6B*+TXV D*80VC0805C*A* 34,600 24,800 16.0 12.5 1,190 6524463
CHPF3743D6B*+MBVC2000**-1A*+TXV 35,000 25,200 16.0 12.8 1,200 6524347
CHPF3743D6B*+TXV D*80VC0604B*A* 34,000 24,400 16.0 12.5 1,220 6524457
CHPF3743D6B*+TXV D*80VC0805C*A* 34,000 24,400 16.0 12.5 1,190 6524464
CHPF3743D6B*+TXV D*96VE1205DNA* 34,600 24,800 15.5 12.2 1,250 7368416
CHPF3743D6B*+TXV D*96VC1205DNA* 34,200 24,600 15.5 12.2 1,115 7369866
CHPF3743D6B*+TXV D*97MC1205DNA* 34,200 24,600 15.5 12.2 1,115 7369934
CHPF4860D6D*+TXV D*80VC0604B*A* 34,600 24,800 16.0 12.5 1,220 6524458
CHPF4860D6D*+TXV D*80VC0805C*A* 34,600 24,800 16.0 12.5 1,190 6524465
CHPF4860D6D*+TXV D*96VC1005CNA* 34,600 24,800 15.5 12.5 1,200 7369861
CHPF4860D6D*+TXV D*96VC1205DNA* 34,200 24,600 15.5 12.5 1,115 7369867
CHPF4860D6D*+TXV D*97MC1005CNA* 34,600 24,800 15.5 12.5 1,200 7369929
CHPF4860D6D*+TXV D*97MC1205DNA* 34,200 24,600 15.5 12.5 1,115 7369935
CSCF4860N6D*+TXV D*96VC1205DNA* 34,200 24,600 15.5 12.2 1,115 7369868
CSCF4860N6D*+TXV D*97MC1205DNA* 34,200 24,600 15.5 12.2 1,115 7369936
DV42PTCD14A* 35,000 25,200 16.0 12.2 1,200 6524334
DV48PTCC14A* 34,400 24,800 15.0 12.2 1,100 7080494
DV48PTCD14A* 36,000 25,800
16.0 12.5 1,200 6524336
CFM AHRI #
See Notes on Page 24.
SS-DX16TC www.daikincomfort.com 21
SS-DX16TC www.daikincomfort.com 21
Page 22
AHRI Ratings AHRI Ra tings
Outdoor
Unit
DX16TC
0481A*
Indoor Units Cooling Ratings
Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³
AVPTC48C14A* 45,500 34,200 14.5 11.7 1,450 7080495
AVPTC48D14A* 46,000 34,600 15.5 12.0 1,575 6524558
CA*F4860*6D*+EEP+TXV 47,000 35,200 14.5 12.0 1,675 6524559
CA*F4860*6D*+MBVC1600**-1A*+TXV 46,000 34,600 15.0 12.0 1,600 6524560
CA*F4860*6D*+MBVC2000**-1A*+TXV 47,000 35,200 16.0 12.5 1,600 6524561
CA*F4860*6D*+TXV D*80VC0604B*A* 45,500 34,200 15.0 12.0 1,400 6524598
CA*F4860*6D*+TXV D*80VC0805C*A* 46,000 34,600 16.0 12.3 1,390 6524601
CA*F4860*6D*+TXV D*80VC1005C*A* 46,000 34,600 16.0 12.0 1,370 6524604
CA*F4860*6D*+TXV DD80VC0805C*A* 46,000 34,600 16.0 12.3 1,380 6524625
CA*F4860*6D*+TXV DD80VC1005C*A* 46,000 34,600 16.0 12.0 1,410 6524627
CA*F4860*6D*+TXV D*96VC0804CNA* 45,500 34,200 15.0 12.0 1,400 7369869
CA*F4860*6D*+TXV D*96VC1005CNA* 45,500 34,200 15.0 12.0 1,400 7369874
CA*F4860*6D*+TXV D*96VC1205DNA* 46,000 34,600 15.5 12.0 1,450 7369879
CA*F4860*6D*+TXV D*97MC0804CNA* 45,500 34,200 15.0 12.0 1,400 7369937
CA*F4860*6D*+TXV D*97MC1005CNA* 45,500 34,200 15.0 12.0 1,400 7369942
CA*F4860*6D*+TXV D*97MC1205DNA* 46,000 34,600 15.5 12.0 1,450 7369947
CA*F4961*6D*+EEP+TXV 48,000 36,000 14.5 12.0 1,675 6524562
CA*F4961*6D*+MBVC1600**-1A*+TXV 46,000 34,600 15.0 12.0 1,400 6524563
CA*F4961*6D*+MBVC2000**-1A*+TXV 47,000 35,200 16.0 12.5 1,400 6524564
CA*F4961*6D*+TXV D*80VC0604B*A* 46,000 34,600 16.0 12.3 1,400 6524599
CA*F4961*6D*+TXV D*80VC0805C*A* 47,000 35,200 16.0 12.5 1,390 6524602
CA*F4961*6D*+TXV D*80VC1005C*A* 46,500 35,000 16.0 12.0 1,370 6524605
CA*F4961*6D*+TXV DD80VC0805C*A* 47,000 35,200 16.0 12.5 1,380 6524626
CA*F4961*6D*+TXV DD80VC1005C*A* 46,500 35,000 16.0 12.0 1,410 6524628
CA*F4961*6D*+TXV D*96VE1004CNA* 46,500 35,000 15.5 12.0 1,550 7368417
CA*F4961*6D*+TXV D*96VE1205DNA* 46,500 35,000 15.5 12.0 1,520 7368420
CA*F4961*6D*+TXV D*96VC0804CNA* 46,500 35,000 15.5 12.0 1,400 7369870
CA*F4961*6D*+TXV D*96VC1005CNA* 46,500 35,000 15.5 12.0 1,400 7369875
CA*F4961*6D*+TXV D*96VC1205DNA* 47,000 35,200 16.0 12.0 1,450 7369880
CA*F4961*6D*+TXV D*97MC0804CNA* 46,500 35,000 15.5 12.0 1,400 7369938
CA*F4961*6D*+TXV D*97MC1005CNA* 46,500 35,000 15.5 12.0 1,400 7369943
CA*F4961*6D*+TXV D*97MC1205DNA* 47,000 35,200 16.0 12.0 1,450 7369948
CAPT4961*4A* D*96VE1004CNA* 46,500 35,000 15.0 12.0 1,550 7368418
CAPT4961*4A* D*96VE1205DNA* 46,500 35,000 15.0 12.0 1,520 7368421
CAPT4961*4A* D*96VC0804CNA* 46,500 35,000 15.0 12.0 1,400 7369871
CAPT4961*4A* D*96VC1005CNA* 46,500 35,000 15.0 12.0 1,400 7369876
CAPT4961*4A* D*96VC1205DNA* 47,000 35,200 15.5 12.0 1,450 7369881
CAPT4961*4A* D*97MC0804CNA* 46,500 35,000 15.0 12.0 1,400 7369939
CAPT4961*4A* D*97MC1005CNA* 46,500 35,000 15.0 12.0 1,400 7369944
CAPT4961*4A* D*97MC1205DNA* 47,000 35,200 15.5 12.0 1,450 7369949
CHPF4860D6D*+EEP+TXV 48,000 36,000 14.5 12.0 1,675 6524565
CHPF4860D6D*+MBVC1600**-1A*+TXV 46,000 34,600 15.0 12.0 1,400 6524566
CHPF4860D6D*+MBVC2000**-1A*+TXV 47,000 35,200 16.0 12.5 1,400 6524567
CHPF4860D6D*+TXV D*80VC0604B*A* 45,500 34,200 15.5 12.0 1,400 6524600
CHPF4860D6D*+TXV D*80VC0805C*A* 45,500 34,200 15.5 12.0 1,390 6524603
CHPF4860D6D*+TXV D*80VC1005C*A* 45,500 34,200 15.5 12.0 1,370 6524606
CHPF4860D6D*+TXV D*96VE1004CNA* 46,000 34,600 15.5 12.0 1,550 7368419
CFM AHRI #
See Notes on Page 24.
22 www.daikincomfort.com SS-DX16TC
22 www.daikincomfort.com SS-DX16TC
Page 23
Outdoor
Unit
DX16TC
0481A*
(cont.)
DX16TC
0601A*
Indoor Units Cooling Ratings
Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³
CHPF4860D6D*+TXV D*96VE1205DNA* 46,000 34,600 15.5 12.0 1,520 7368422
CHPF4860D6D*+TXV D*96VC0804CNA* 46,000 34,600 15.5 12.0 1,400 7369872
CHPF4860D6D*+TXV D*96VC1005CNA* 46,000 34,600 15.5 12.0 1,400 7369877
CHPF4860D6D*+TXV D*96VC1205DNA* 47,000 35,200 15.5 12.0 1,450 7369882
CHPF4860D6D*+TXV D*97MC0804CNA* 46,000 34,600 15.5 12.0 1,400 7369940
CHPF4860D6D*+TXV D*97MC1005CNA* 46,000 34,600 15.5 12.0 1,400 7369945
CHPF4860D6D*+TXV D*97MC1205DNA* 47,000 35,200 15.5 12.0 1,450 7369950
CSCF4860N6D*+EEP+TXV 48,000 36,000 14.5 12.0 1,675 6524568
CSCF4860N6D*+TXV D*96VC0804CNA* 45,500 34,200 15.0 12.0 1,400 7369873
CSCF4860N6D*+TXV D*96VC1005CNA* 45,500 34,200 15.0 12.0 1,400 7369878
CSCF4860N6D*+TXV D*96VC1205DNA* 46,000 34,600 15.5 12.0 1,450 7369883
CSCF4860N6D*+TXV D*97MC0804CNA* 45,500 34,200 15.0 12.0 1,400 7369941
CSCF4860N6D*+TXV D*97MC1005CNA* 45,500 34,200 15.0 12.0 1,400 7369946
CSCF4860N6D*+TXV D*97MC1205DNA* 46,000 34,600 15.5 12.0 1,450 7369951
DV48PTCC14A* 45,500 34,200 14.5 11.7 1,450 7080496
DV48PTCD14A* 46,000 34,600 15.5 12.0 1,575 6524557
AVPTC60D14A* 57,000 42,500 15.5 12.0 1,780 6524631
CA*F4860*6D*+MBVC2000**-1A*+TXV 55,500 41,000 15.5 12.0 1,800 6524632
CA*F4860*6D*+TXV D*80VC0805C*A* 55,500 41,000 15.5 12.0 1,590 6524669
CA*F4860*6D*+TXV D*80VC1005C*A* 55,500 41,000 15.5 12.0 1,610 6524672
CA*F4860*6D*+TXV DD80VC0805C*A* 55,500 41,000 15.5 12.0 1,580 6524698
CA*F4860*6D*+TXV DD80VC1005C*A* 55,500 41,000 15.5 12.0 1,550 6524700
CA*F4860*6D*+TXV D*97MC1205DNA* 55,000 41,000 15.5 12.0 1,600 7363753
CA*F4860*6D*+TXV D*96VC1205DNA* 55,000 41,000 15.5 12.0 1,600 7369894
CA*F4860*6D*+TXV D*97MC0804CNA* 55,000 41,000 15.0 11.7 1,550 7369952
CA*F4860*6D*+TXV D*97MC1005CNA* 55,000 41,000 15.0 11.7 1,600 7369957
CA*F4961*6D*+EEP+TXV 56,000 41,500 14.0 11.8 1,550 6524633
CA*F4961*6D*+MBVC2000**-1A*+TXV 57,000 42,500 16.0 12.3 1,800 6524634
CA*F4961*6D*+TXV D*80VC0805C*A* 56,000 41,500 15.5 12.3 1,590 6524670
CA*F4961*6D*+TXV D*80VC1005C*A* 56,000 41,500 15.5 12.0 1,610 6524673
CA*F4961*6D*+TXV DD80VC0805C*A* 56,000 41,500 15.5 12.3 1,580 6524699
CA*F4961*6D*+TXV DD80VC1005C*A* 56,000 41,500 15.5 12.0 1,550 6524701
CA*F4961*6D*+TXV D*97MC1205DNA* 55,000 41,000 15.5 12.0 1,600 7363754
CA*F4961*6D*+TXV D*96VE1205DNA* 56,000 41,500 15.5 11.7 1,520 7368423
CA*F4961*6D*+TXV D*96VC0804CNA* 55,000 41,000 15.5 11.7 1,550 7369885
CA*F4961*6D*+TXV D*96VC1005CNA* 55,000 41,000 15.5 11.7 1,600 7369890
CA*F4961*6D*+TXV D*96VC1205DNA* 55,000 41,000 15.5 12.0 1,600 7369895
CA*F4961*6D*+TXV D*97MC0804CNA* 55,000 41,000 15.5 11.7 1,550 7369953
CA*F4961*6D*+TXV D*97MC1005CNA* 55,000 41,000 15.5 11.7 1,600 7369958
CAPT4961*4A* D*97MC1005CNA* 55,000 41,000 15.0 11.7 1,600 7363750
CAPT4961*4A* D*97MC1205DNA* 55,000 41,000 15.0 12.0 1,600 7363755
CAPT4961*4A* D*96VE1205DNA* 56,000 41,500 15.0 11.7 1,520 7368424
CAPT4961*4A* D*96VC1205DNA* 55,000 41,000 15.0 12.0 1,600 7369896
CAPT4961*4A* D*97MC0804CNA* 55,000 41,000 15.0 11.7 1,550 7369954
CHPF4860D6D*+EEP+TXV 56,000 41,500 14.0 11.8 1,550 6524635
CHPF4860D6D*+MBVC2000**-1A*+TXV 57,000 42,500 15.5 12.3 1,800 6524636
CHPF4860D6D*+TXV D*80VC0805C*A* 56,000 41,500 15.5 12.3 1,590 6524671
CFM AHRI #
See Notes on Page 24.
SS-DX16TC www.daikincomfort.com 23
SS-DX16TC www.daikincomfort.com 23
Page 24
AHRI Ratings
Outdoor
Unit
Coils/Air Handlers Furnaces Total¹ Sens.¹ SEER² EER³
Indoor Units Cooling Ratings
CHPF4860D6D*+TXV D*80VC1005C*A* 56,000 41,500 15.5 12.0 1,610 6524674
CHPF4860D6D*+TXV D*97MC1005CNA* 55,000 41,000 15.5 11.7 1,600 7363751
CHPF4860D6D*+TXV D*97MC1205DNA* 55,000 41,000 15.5 12.0 1,600 7363756
CHPF4860D6D*+TXV D*96VE1205DNA* 56,000 41,500 15.5 11.7 1,520 7368425
CHPF4860D6D*+TXV D*96VC0804CNA* 55,000 41,000 15.5 11.7 1,550 7369887
CHPF4860D6D*+TXV D*96VC1205DNA* 55,000 41,000 15.5 12.0 1,600 7369897
DX16TC
0601A*
(cont.)
CHPF4860D6D*+TXV D*97MC0804CNA* 55,000 41,000 15.5 11.7 1,550 7369955
CSCF4860N6D*+EEP+TXV 56,000 41,500 14.0 11.8 1,550 6524637
CSCF4860N6D*+TXV D*97MC1005CNA* 55,000 41,000 15.0 11.7 1,600 7363752
CSCF4860N6D*+TXV D*97MC1205DNA* 55,000 41,000 15.0 12.0 1,600 7363757
CSCF4860N6D*+TXV D*96VC0804CNA* 55,000 41,000 15.0 11.7 1,550 7369888
CSCF4860N6D*+TXV D*96VC1205DNA* 55,000 41,000 15.0 12.0 1,600 7369898
CSCF4860N6D*+TXV D*97MC0804CNA* 55,000 41,000 15.0 11.7 1,550 7369956
DV60PTCD14A* 57,000 42,500 15.5 12.0 1,780 6524630
¹ BTU/h
² Seasonal Energy Eciency Rao; Cered per AHRI 210/240 @ 80°F/ 67°F/ 95°F
³ Energy Eciency Rao @ 80°F/ 67°F/ 95°F
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• When matching the outdoor unit to the indoor unit, use the piston supplied with the
outdoor unit or that specied on the piston kit chart supplied with the indoor unit.
• EEP - Order from Service Dept. Part No. B13707-38 or new Solid State Board B13707-35S. Part No. B13707-38
is not interchangeable with B13707-35S. The Goodman Gas Furnace contains the EEP cooling me delay
CFM AHRI #
24 www.daikincomfort.com SS-DX16TC
Page 25
Dimensions
Product Specifications
Model
DX16TC0241A* 29 29 32¼
DX16TC0361A* 29 29 32¼
DX16TC0481A* 35½ 35½ 36¼
DX16TC0601A* 35½ 35½ 38¼
Dimensions
W" D" H"
SS-DX16TC www.daikincomfort.com 25
Page 26
WIR
ING
C
OD
E
FA
CTORY
W
I
RI
NG
HIGH VOLTAGE
LOW VOLTAGE
HIGH VOLTAGE
FIELD
OPTI ONAL H IGH
VOLTAGE
OPTIONAL LOW
VOLTAGE
CO
LOR COD
E
BK --------------- BLA CK
BL --------------- BLUE
BL/PK -- -------- BLUE/ PINK STRIPE
BR --------------- BR OWN
OR --------- ------ ORA NGE
PU --------------- PURP LE
RD --------------- RED
WH -- ----------- - WHI TE
YL ------ ------ --- YE LLO W
YL/PK ---------- YELLOW /PINK STR IPE
13
4
6
E11
E16
PU
RD (LO W)
BR
RE LAY
REL AY
RE LAY
HERM
COM
START
RUN
230 VAC
SUPPLY
L1
L2
E13
L2 OUT
L2
L1
E10
R
C
START
E5
E8
CAP COM
E17
START
RLY
BK (HI GH)
UC BO ARD
LPS
FUSE
O
L
R
C
W1
Y1
E2
Y2
FAN
RUN
RELAY
RELAY
1
2
12R
C
E25
E29
E28
E26
E24
E23
E22
E14
HIGH
LPC O
HPCO
E47
E1
OAT
OCT
OAS
YL
BK
RD
RD
YL
GND
LOW VOLTAGE
BARRIER
BL/PK
BK
YL/PK
YL/PK
RD
BK
BK
BK
BL/PK
IO
AUX
MA IN
C
R
S
AUX
MAI N
COMP
CSY2C
BK
YL
RD
CONT ROL B OX
O
L
Y2
Y1
W1
C
O
L (O PTI ONAL)
Y2Y1W1
C
LEGACY IND OOR T-ST AT
C
R21
CR2
1
R
R
C
R
INDOOR POW ER SUPPLY 24 VAC
COMMUNICATING INDOOR T-STAT
INDOOR POWER SUPPLY 24 VAC
TO INDOOR COMMUNICATING PCB
0140R00138-G
THIS WIRING SCHEMA TIC S HOWS T HE LE GACY W IRING FROM
THE FACTORY. T HE WIRES GO TO INDOOR T-STAT AS SHOWN
IN "L EGACY I NDOOR T-ST AT". T O W IRE TH E SYSTEM IN
COMMUNICATING MODE, THE INSTALLER HAS T O WORK
THE WIRING AS SHOWN IN "COMMUNICATING INDOOR T-STAT".
REFER TO TH E IO MANUA L LOCAT ED IN CO MMUNICAT ING
T-STAT K IT FOR MORE DE TAILS.
FRO M
OUTDOOR
UNI T
FROM
OUTD OOR
UNIT
RES
25
1
SC
OPTIONAL HARD STAR T
BK
RD
SR
CM
COMP
O
NE
NT C O
DE
C ----------- ---- CONTACTOR
CM ------------ CONDENSER FAN MOTOR
COMP -- ------ CO MPRESSOR
CS ------------- C OMPRESSOR SO LENOID
HPS -- --------- HIGH PRESSURE SW ITC H
IO -------------- INTE RNAL OVERLO AD
LPS ---------- LOW PR ESSURE SWIT CH
OAS -- --------- OUT DOOR AIR SENSO R
RCC F --------- RUN CAPACITOR FOR
COM PRESSOR & F AN
SC ------------- START CAPACI TOR FOR
COM PRESSOR (OPT IONAL)
SR ------------- START RELAY FO R
COM PRESSOR (OPT IONAL)
CH ------------ CRANKCASE HEATER
(OPTIONAL)
CHS ---------- CRANKCA
SE HEATER
SWIT CH (OPTIONAL )
CONTROL S SHOWN W ITH
THERMOS TAT IN 'OFF' PO SITION.
YLPUBL
RD
NOTES :
1. IF DT IS NOT PRESENT, HPS BL/PK
WIR E GOES DI RECTL Y TO TE RMINAL
E29.
2. USE CO PPER SUPPLY WIRES ONLY.
3. USE 40VA TRANSF ORME R MINIMUM .
4. CRANKCASE HEATER FACTORY
INSTALLE D OPT ION.
5. USE N.E.C. CLASS 2 WIRES.
H
FC
RCCF
PU
BR
RD
YL
DT
SEE N OTE 1
HPS
L1
L2
K2
C
R
S
COM P
R
S
HERM
C
PSC FAN MOTOR
C
UC CONT ROL
HERM
CAP
COM
C
HIGH
LOW
K4
K3
RUN CAPA CITOR
FAN
CAP
1
25
SC
SR
OPTIONAL HARD START
O
L
R
C
W1
Y1
E2
Y2
1
2
LPS
E22
E23
E24
E26
E47
E1
HPS
OAS
DT
E28
HIGH VOLTAGE AREA
LOW VOLT AGE AR EA
E29
NOTE 2
CH
E21
E14
CS
NOTE 2
CHS
GR/YL
CH
BK
BK
NOTE 4
RD
NOTE 4
RD
K6
CHS
CH
SEE N OTE 5
SEE N OTE 5
SEENOTE5
SEE NO TE 5
Wiring Diagram
26 www.daikincomfort.com SS-DX16TC
⚡
High Voltage: Disconnect all power before servicing or installing this unit. Mulple power
sources may be present. Failure to do so may cause property damage, personal injury, or death.
⚠ Warning
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
Page 27
Accessories
Product Specifications
Model Description
DX16TC
024**
DX16TC
036**
DX16TC
048**
DX16TC
060**
ABK-20 Anchor Bracket Kit^ X X X X
ASC-01 An-Short Cycle Kit X X X X
B1141643¹ 24V Transformer X X X X
CSR-U-1 Hard-start Kit X X X
CSR-U-2 Hard-start Kit X
CSR-U-3 Hard-start Kit X
FSK01A² Freeze Protecon Kit X X X X
LSK02A Liquid Line Solenoid Valve X X X X
OT18-60A³ Outdoor Thermostat/Lockout Thermostat X X X X
TX2N4 TXV Kit
TX2N4A TXV Kit X
TX3N4⁴ TXV Kit X
TX5N4 TXV Kit X X
^ Contains 20 brackets; four brackets needed to anchor unit to pad
¹ This component is included in the CTK01AA communicang thermostat kit.
² Installed on indoor coil
³ Available in 24V legacy mode only. This feature is integrated in the communicang mode.
Note: Maximum number of installed accessories at the same me is limited by the size of the unit’s control box.
SS-DX16TC www.daikincomfort.com 27
Page 28
Notes
Our connuing commitment to quality products may mean a change in specicaons without noce.
© 2015 • Houston, Texas • Printed in the USA.
28 www.daikincomfort.com SS-DX16TC