Goodman GCVC960603BNAA, GCVC961205DNAA, GCVC960804CNAA, GCVC961005CNAA, GMVC960403BNAA Technical Manual

...
TECHNICAL MANUTECHNICAL MANU
TECHNICAL MANU
TECHNICAL MANUTECHNICAL MANU
TM
ALAL
AL
ALAL
*CVC96/*MVC96
96% Gas Furnace Unit s
Refer to Service Manual RS6612010 for installation, operation, and troubleshooting information.
Refer to the appropriate Parts Catalog for part number information.
This manual is to be used by qualified, professionally trained HVAC technicians only. Goodman does not assume any responsibility for property damage or personal injury due to improper service procedures performed by an unqualified person.
RT6612032
August 2014
Copyright ©2014 Goodman Manufacturing Company, L.P.
PRODUCT IDENTIFICATION
e
e
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
*MVC960603BNAA
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Brand Minor Revision G - Goodman A - Initial Releas A - Amana B - 1s t Revision
Configuration M - Upflow/Horizontal Major Revision C - Downflow/Horizontal A - Initial Releas K - Dedic at ed Upflow B - 1s t Revision D - Dedi cate d Downflow
NOx
Motor N - Low Nox
V - Vari able S peed E CM /ComfortNet E - Multi-Speed ECM S - Single Speed
Gas V al ve Cabinet Width M - Modulating A - 14" V - 2 Stage B - 17. 5" H - Convert i ble 2 S tage C - 21" S - Single Stage D - 24.5"
AFUE Maximum CFM
96 - 96% AF UE 2 - 800 CFM
3 - 1200 CFM
4 - 1600 CFM MBTU/h 5 - 2000 CFM 40 - 40,000 60 - 60,000 80 - 80,000 100 - 100,000 120 - 120,000
HIGH VOLTAGE!
WARNING
WARNING
Disconnect ALL power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death.
WARNING
WARNING
arising from improper service or service procedures. If you install or perform service on this unit, you assume responsibility for any personal injury or property damage which may result. Many jurisdictions require a license to install or service heating and air conditioning equipment.
Goodman will not be responsible for any injury or property damage
2
Installation and repair of this unit
WARNING
WARNING
ments of an "entry level technician", at a minimum, as specified by the Air-Conditioning, Heating, and Refrigera­tion Institute (AHRI). Attempting to install or repair this unit without such background may result in product damage, personal injury or death.
should be performed dividuals meeting the require-
ONLY by in-
PRODUCT IDENTIFICATION
The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
*CVC960403BNAA *CVC960603BNAA *CVC960804CNAA *CVC961005CNAA
*CVC961205DNAA *MVC960403BNAA *MVC960603BNAA *MVC960803BNAA *MVC960804CNAA *MVC961005CNAA *MVC961205DNAA
WARNING
WARNING
WARNING
WARNING
Serious property damage, personal injury, reduced unit performance and/or hazardous conditions may result from the use of such non-approved devices.
The United States Environmental Protection Agency (“EPA”) has issued various regulations re­garding the introduction and disposal of refrigerants introduced into this unit. Failure to follow these regulations may harm the environment and can lead to the imposition of substantial fines. These regulations may vary by jurisdiction. Should questions arise, contact your local EPA of­fice.
Do not connect or use any device that is not design certified by Goodman for use with this unit.
WARNING
WARNING
als or use gasoline or other flammable liquids or vapors in the vicinity of this appliance.
To prevent the risk of property damage, personal injury, or death, do not store combustible materi-
3
FURNACE SPECIFICATIONS
*MVC96
0403BNA
*MVC96
0603BNA
*MVC96
0803BNA
*MVC96
0804CNA
*MVC96
1005CNA
*MVC96
1205DNA
High Fire Input¹ 40,000 60,000 80,000 80,000 100,000 120,000
High Fire Output¹ 38,400 57,600 76,800 76,800 96,000 115,200
Low-Fire Steady-State Input¹ 28,000 42,000 56,000 56,000 70,000 84,000
Low-Fire Steady-State Output¹ 26,880 40,320 53,760 53,760 67,200 80,640
AFUE² 969696969696
Temperature Rise Range (°F) 35 - 65 20 - 50 35 - 65 25 - 55 35 - 65 35 - 65
Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3"
No. of Burners 2 3 4 4 5 6
Circulator Blower
Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 1.5 - 3 1.5 - 4 2 - 5 2 - 5
Size (D x W) 10" x 8" 11" x 8" 11" x 8" 11" x 10" 11" x 10" 11" x 11"
Horsepower @ 1075 RPM
½½½¾
11
Speed VS ECM VS ECM VS ECM VS ECM VS ECM VS ECM
Filter S ize (in²)
Permanent 341 731 683 853 853 1,024
Disposable 171 366 341 427 427 512
Electrical Data
Min. Circuit Ampacity 7.8 7.8 7.8 10.6 14.4 14.4
Max. Overcurrent Device (amps) 15 15 15 15 20 20
Shipping Weight (lbs)
¹NaturalGasBTU/h ² ³
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• and noise issues.
• may necessitate greater clearances than the minimum clearances listed above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.
114 117 120 141 143 156
4
FURNACE SPECIFICATIONS
*CVC96
0403BNA
*CVC96
0603BNA
*CVC96
0804CNA
*CVC96
1005CNA
*CVC96
1205DNA
High Fire Input¹ 40,000 60,000 80,000 100,000 120,000
High Fire Output¹ 38,400 57,600 76,800 96,000 115,200
Low-Fire Steady-State Input¹ 28,000 42,000 56,000 70,000 84,000
Low-Fire Steady-State Output¹ 26,880 40,320 53,760 67,200 80,640
AFUE² 9696969696
Temperature Rise Range (°F) 20 - 50 35 - 65 25 - 55 45 - 75 35 - 65
Vent Diameter³ 2" - 3" 2" - 3" 2" - 3" 2" - 3" 2" - 3"
No. of Burners 2 3 4 5 6
Circulator Blower
Available AC @ 0.5" ESP 1.5 - 3 1.5 - 3 1.5 - 4 2 - 5 2 - 5
Size (D x W) 10" x 8" 11" x 8" 11" x 10" 11" x 10" 11" x 11"
Horsepower @ 1075 RPM
½½¾
11
Speed VSECM VSECM VSECM VSECM VSECM
Filter Size (in²)
Permanent 488 512 853 711 1,024
Disposable 244 256 427 356 512
Electrical Data
Min. Circuit Ampacity 7.8 7.8 10.6 14.4 14.4
Max. Overcurrent Device (amps) 15 15 15 20 20
Shipping Weight (lbs)
¹ Natural Gas BTU/h ² ³
Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run
and must be 2" or 3" diameter PVC.
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
• and noise issues.