OPERATING MANUAL AND RECOMMENDED TREATMENT DOSAGES
proven clinical results | rechargeable, easy and safe to use | www.gd-energies.com
With the Healing Power of a Clinic
The world’s best portable soft-laser medical device
For professional and home adjunctive use in therapy of: Carpal tunnel syndrome, fibromyalgia, myofascial pain syndromes (e.g knee pain, low back pain, neck/ upper back pain, muscle pain etc.), joint disorders/arthritis (e.g Achilles tendinitis, tennis elbow etc.), medical skin conditions (e.g acne, herpes simplex, wound healing, fresh and old surgical wounds or scars, skin wounds, burns etc.), post-pregnancy stretch marks (striae gravidarum), inflammation, dental medicine, acupuncture and sports injuries.
CONGRATULATIONS!
You are holding the best portable soft-laser medical device. This manual will help you benefit from the most advanced, professional and effective therapy of the 21st century - anywhere and any time you need it. It is the cutting edge technology in soft-laser therapy: a light, portable, rechargeable device, friendly to both caregiver and patient, with clinical healing power equal to soft-laser devices used only in hospitals and prestigious clinics.
Before operating your B-CURE
®
LASER - please read the operating
manual and treat according to the recommended dosages.
We, at Good Energies, are always happy to hear from you. Please feel free to contact us with your own stories of success, or with any comments or questions you may have.
B-CURE® LASER LLLT-808
|
2
Part 1: Operating Instructions for B-CURE
®
LASER LLLT-808
1. Identification of the Parts .......................................................4
2. Charging the Batteries ............................................................5
3. Switching the Device ON and Setting the Treatment Time ....6
4. End of Treatment and Switching the Device Off .....................9
5. Control Panel and Troubleshooting ......................................10
6. B-CURE
®
LASER Treatment Dosages ..................................13
7. Treatment Protocols .............................................................17
8. Instructions for Best Results ................................................24
9. Precautionary Measures .......................................................25
10. Cleaning of the Device ..........................................................25
Part 2: The healing nature of soft-laser (LLLT)
1. What is soft-laser LLLT (Low Level Laser Therapy)? .............26
2. The Scientific Breakthrough of B-CURE
®
LLLT 808 ...............27
3. How B-CURE
®
Laser Works ...................................................28
4. Clinical Areas and Treatment Applications (partial list) ........29
5. The Clinical Surveys Prove......................................................30
6. B-CURE
®
LASER LLLT - 808 is Recommended by .................31
7. Technical Specifications ..........................................................32
8. Warranty ..................................................................................35
9. Approvals and Safety Certifications ........................................36
Table of Contents
3
|
B-CURE® LASER LLLT-808
1. Identification of the Parts
1. Power button - main operating button for switching the device on and off.
2. Timer button - button for setting the treatment time.
3. Timer - LCD display of treatment time, device status, and trouble shooting.
4. Treatment start button.
5. Contact start button - area for pressure operation onto the treated area (green light indicates when the device is operating).
6. Connection point for the charger.
7. Batteries compartment.
Part 1: Operating Instructions for B-CURE® LASER LLLT-808
1. Powerr button
2. Button for setting treatment time
3. Timer LCD screen
4. Treatment start button
5. Contact start button
6. Connection point to charger
7. Battery compartment
B-CURE® LASER LLLT-808
|
4
2. Charging and Replacing the Batteries with new ones
In some cases the device comes with partially charged batteries. It is always recommended to fully charge the device before use. Insert the three AAA rechargeable batteries into the battery compartment in accordance with the instructions in the illustration on the right. Connect the charger to an electrical socket. Connect the plug from the charger to the charger connection point on the device (No. 6; see identification of parts on page 4). During the first charge nothing will appear on the LCD screen (No. 3) for the first several seconds; eventually the letters “CHRG” will appear. When the batteries are fully charged, the “FULL” indication will appear on the LCD screen. Sometimes the dots on the right will keep on moving as if charging continues, however the batteries are fully charged and the treatment may start. Charging time is approximately 5 hours.
The device should not be operated while being charged.
5
|
B-CURE® LASER LLLT-808
3. Switching the Device ON and Setting the Treatment Time
3.1 Switching the Device ON
Press the main operating button (No.1). A short beep will be heard and the timer (a digital clock that can be pressed to define treatment time) will be shown on the screen (No. 3).
Only AC/DC adaptor supplied with the device
is allowed for batteries charging. In case of malfunction, or if you lose the AC/DC adaptor, please contact the supplier or service center. Use only 1.2V AAA Rechargeable NiMH type
batteries. Install the batteries with the correct polarity.
Do not mix new and old batteries.
Do not use other types of batteries to prevent the
risk of fire or explosion. The batteries may explode if not handled with care.
Do not disassemble, heat above 100°C,
or incinerate batteries. Dispose of spent batteries at an appropriate
collection point.
Warnings:
B-CURE® LASER LLLT-808
|
6
3.2 Adjusting the Timer on the LCD Screen
Press the button (No. 2) on the right (+) or on the left (-) for defining treatment time. The timer can be adjusted by intervals of 30 seconds. Adjust the time as required for the treatment as recommended in the Dosages Table on Page 14.
3.3 Starting a Treatment
Operation can be started in two ways:
1. Directly applying device to area of treatment: Operating by pressure – to be used only if there is no exposed tissue or open wound:
Place the area for pressure operation (No. 5) on the area to be treated and gently press the device onto the skin. The electronic micro-button will operate the laser automatically. To stop the operation, simply move the device out of contact with the skin
2. Operating by pressing treatment start button:
Press the treatment start button (No. 4) located on the left-hand side of the device to operate it. Releasing the treatment start button will immediately stop the operation.
CAUTION: Never point the laser beam at anyone’s eyes!
7
|
B-CURE® LASER LLLT-808
6
7
1
2
3
4
5
3. For continuous activation of the device: after setting the treatment time,
and in order to prevent the need for a long, tiring pressing, the B-Cure laser will operate continuously in the following way: with one hand press the treatment start button (No. 4), after two seconds, press simultaneously the main operation button (number 1) with a touch. Afterwards release the treatment start button (No. 4) To stop the devices action – press lightly the treatment start button (No. 4).
The device is in operation when:
the time shown on the timer will decrease until it reaches “00:00”.
Operation will stop automatically and a beep will sound. the green light appears, indicating that the device is on. The laser beam
of the B-CURE
®
device is invisible.
you hear a “beep” at 3 second intervals to indicate that the
device is operational.
B-CURE® LASER LLLT-808
|
8
4. End of Treatment and Switching the Device Off
If the time planned for a treatment was not fully used, the timer will show the remaining treatment time. The
remaining treatment time will be shown when the device is next switched ON. To reset any time left from a previous treatment to zero, press the main operating button (No.1) for more than
2 seconds when switching the device on. To switch the device off, press the main operating button for 2 seconds until a beep is sounded and nothing is
shown on the display (the
LCD screen will be cleared completely).
9
|
B-CURE® LASER LLLT-808
5. Control Panel and Troubleshooting
Indication Status
The batteries are being charged.
The batteries are fully charged.
The “
” indicates that the device is presently in operation.
Full Battery Power.
The batteries are low; two beeps will sound after switching the device on as a reminder to charge it.
The batteries are exhausted. Charge your device immediately.
B-CURE® LA SER L LLT-808
|
10
Indication Status
B-CURE® LASER will automatically power off after 10 beeps because of flat batteries..
The “LOW” sign appears on the screen when laser power falls below the required level. Stop the treatment. This situation can happen for the following reasons:
1. Battery power is too low.
2. The laser diode has reached the end of its life time and has to be replaced at the service center.
3. The device is being operated under environmental conditions not conforming to the specifications; for example, the device is being operated at an excessive external temperature higher than 40ºC. Recharge the batteries, turn the device on, and then see if the “LOW” sign still appears. If it does, check if the environment is not too warm, and draw away from the warm area. In case the area is not above 40ºC and the “LOW” sign is still on, the device is to be sent to the service center for replacement of the laser diode.
11
|
B-CURE® LASE R LLLT-80 8