Notes:
(1) Tested with pulses tp=20ms.
(2) Valid provided that leads are kept at ambient temperature at a distance of 8 mm from case.
Type
Zener voltage range
1)
Dynamic resistance Reverse leakage
current
Temp. co efficient
of Zener voltage
V
znom
IZT for VZT
2)
r
zjT
and r
zjk
at I
ZK
IR 2) at V
R
TK
VZ
VmA V mA uA V %/K
BZX 85/C 2V 7 2.7 80 2.5 ... 2 .9 <20 <400 1 <150 1 -0.08 ... -0.05
BZX 85/C 3V0 3.0 80 2.8 ... 3 .2 <20 <400 1 <100 1 -0.08 ... -0.05
BZX 85/C 3V3 3.3 70 3.1 ... 3 .5 <20 <400 1 <40 1 -0.08 ... -0.05
BZX 85/C 3V6 3.6 60 3.4 ... 3.8 <15 <500 1 <20 1 -0.08 ... -0.05
BZX 85/C 3V9 3.9 60 3.7 ... 4.1 <15 <500 1 <10 1 -0.07 ... -0.02
BZX 85/C 4V3 4.3 50 4.0 ... 4.6 <13 <500 1 <3 1 -0.07 ... +0.01
BZX 85/C 4V7 4.7 45 4.4 ... 5.0 <13 <600 1 <3 1 -0.03 ... +0.04
BZX 85/C 5V1 5.1 45 4.8 ... 5.4 <10 <500 1 <1 1.5 -0.01 ... +0 .04
BZX 85/C 5V6 5.6 45 5.2 ... 6 .0 <7 < 400 1 <1 2 0 ... +0 .045
BZX 85/C 6V2 6.2 35 5.8 ... 6.6 <4 < 300 1 <1 3 +0.01 ... +0.055
BZX 85/C 6V8 6.8 35 6.4 ... 7.2 <3.5 < 300 1 <1 4 +0.015 ... +0.06
BZX 85/C 7V5 7.5 35 7.0 ... 7.9 <3 <200 0.5 <1 4.5 +0.02 ... + 0.065
BZX 85/C 8V2 8.2 25 7.7 ... 8.7 <5 <200 0.5 <1 6.2 0.03 ... 0.07
BZX 85/C 9V1 9.1 25 8.5 ... 9.6 <5 <200 0.5 <1 6.8 0.035 ... 0.075
BZX 85/C 10 10 25 9.4 ... 1 0.6 <7 <20 0 0.5 <0.5 7 0 .04 ... 0 .08
BZX 85/C 11 11 20 10.4 ... 11.6 < 8 <300 0 .5 <0.5 8.2 0.045 ... 0.08
BZX 85/C 12 12 20 11.4 ... 12 .7 < 9 <350 0 .5 <0.5 9.1 0.045 ... 0.08 5
BZX 85/C 13 13 20 12.4 ... 1 4.1 < 10 <400 0.5 <0.5 10 0 .05 ... 0 .085
BZX 85/C 15 15 15 13.8 ... 1 5.6 < 15 <500 0.5 <0.5 11 0 .055 ... 0.09
BZX 85/C 16 16 15 15.3 ... 1 7.1 < 15 <500 0.5 <0.5 12 0 .055 ... 0.09
BZX 85/C 18 18 15 16.8 ... 1 9.1 < 20 <500 0.5 <0.5 13 0.06 ... 0 .09
BZX 85/C 20 20 10 18.8 ... 2 1.2 < 24 <600 0.5 <0.5 15 0.06 ... 0 .09
BZX 85/C 22 22 10 20.8 ... 2 3.3 < 25 <600 0.5 <0.5 16 0 .06 ... 0 .095
BZX 85/C 24 24 10 22.8 ... 2 5.6 < 25 <600 0.5 <0.5 18 0 .06 ... 0 .095
BZX85/C 27 27 8 25.1 ... 28.9 <30 <750 0.25 <0.5 20 0.06 ... 0.095
BZX 85/C 30 30 8 2 8 ... 32 <30 <10 00 0.25 <0.5 2 2 0.06 ... 0.095
BZX 85/C 33 33 8 3 1 ... 35 <35 <10 00 0.25 <0.5 24 0.06 ... 0.095
BZX 85/C 36 36 8 3 4 ... 38 <40 <100 0 0.2 5 < 0.5 27 0.0 6 ... 0.095
BZX 85/C 39 39 6 3 7 ... 41 <50 <100 0 0.2 5 < 0.5 30 0.0 6 ... 0.095
BZX 85/C 43 43 6 4 0 ... 46 <50 <100 0 0.2 5 < 0.5 33 0.0 6 ... 0.095
BZX 85/C 47 47 4 4 4 ... 50 <90 <150 0 0.2 5 < 0.5 36 0.0 6 ... 0.095
BZX 85/C 51 51 4 4 8 ... 54 <115 <1 500 0.25 <0 .5 39 0.06 ... 0.09 5
BZX 85/C 56 56 4 5 2 ... 60 < 12 0 < 2000 0.2 5 < 0.5 43 0.0 6 ... 0.0 95
BZX 85/C 62 62 4 5 8 ... 66 < 125 < 200 0 0.2 5 < 0.5 47 0.0 6 ... 0.0 95
BZX 85/C 68 68 4 6 4 ... 72 < 130 < 200 0 0.2 5 < 0.5 51 0.0 6 ... 0.0 95
BZX 85/C 75 75 4 7 0 ... 79 < 135 < 200 0 0.2 5 < 0.5 56 0.0 6 ... 0.0 95
BZX 85/C 82 82 2.7 77 ... 8 7 <20 0 <30 00 0.25 <0.5 62 0.07 ... 0.10
BZX 85/C 91 91 2.7 85 ... 9 6 <25 0 <30 00 0.25 <0.5 68 0.07 ... 0.10
BZX 85/C 10 0 100 2.7 9 4 ... 106 < 350 <3000 0.25 <0.5 75 0.07 ... 0.11
BZX85/C 110 110 2.7 104 ... 116 <450 <4000 0.25 <0.5 82 0.07 ... 0.11
BZX 85/C 12 0 120 2 114 ... 12 7 < 550 < 450 0 0.2 5 < 0.5 91 0 .07 ... 0 .11
BZX85/C 130 130 2 124 ... 141 <700 <5000 0.25 <0.5 100 0.07 ... 0.11
BZX85/C 150 150 2 138 ... 156 <1000 <6000 0.25 <0.5 110 0.07 ... 0.11
BZX85/C 160 160 1.5 153 ... 171 <1100 <6500 0.25 <0.5 120 0.07 ... 0.11
BZX85/C 180 180 1.5 168 ... 191 <1200 <7000 0.25 <0.5 130 0.07 ... 0.11
BZX85/C 200 200 1.5 188 ... 212 <1500 <8000 0.25 <0.5 150 0.07 ... 0.11
2