Artikel
Articles
68883
Montageanleitung für geschirmte 24Port Patch Panels
93048
90854
90855
93865
93866
94036
Full shielded patch panel installation instruction
1
Abdeckung demontieren
Open the cover.
3
IDC(KRONE)
A
B
5
4
1
2
3
6
7
8
T568A
Pin 5 White/Blue Pin 5 White/Blue
Pin 4 Blue Pin 4 Blue
Pin 1 White/Green Pin 1 White/Orange
Pin 2 Green Pi n 2 Or ange
Pin 3 White/Orange Pin 3 White/Green
Pin 6 Orange Pin 6 Green
Pin 7 White/Brown Pin 7 White/Brown
Pin 8 Brown Pi n 8 Br own
T568B
2
50mm
Kabelmantel abisolieren, Schirmung umschlagen und
Adernpaare vorbereiten
Strip approximately 50mm from the cable jacket, fold
back the foil or braid shield and prepare each pair.
4
.
Farbcode wahlen und Adernpaare in die LSA-Kontakte legen
.
Follow the direction on the color-coding sticker for
T568A or T568B wiring and set pairs into proper position.
5
Kabelschirm unter die Klemmen legen und handfest anziehen
Fasten the screws through metal case to hold
tightly down for two cable jackets in the same time.
6
LSA-Kontakte mit Einlegewerkzeug auegen
Punch down wires with LSA-tool.
Installierte K abel mit Kabelbindern zugentlasten
Fasten cable ties for additional strain relief.
Kabelbinder
Cable tie
Revisionsdatum
Revision Date
Version 1
2014-01-29