golmar T632 User Manual

USER MANUAL
C d. 50121o 878 T G E632 B2 N REV.0 13 6
Audio and Video
door entry system
2 wires installation GB2 Nexa Modular
INTRODUCTION
First of all we would like to thank and congratulate you for the purchase of this product.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers. To obtain the maximum profit of these features and a properly wired installation, we kindly recommend you to expend a few minutes of your time to read this manual.
INDEX
2
STARTING RECOMMENDATIONS
- Do not use excessive force when tightening the power supply connector screws.
- Install or modify the equipment, without the power connected.
- The installation and handling of these equipments must be performed by authorised personnel.
- The entire installation must be at least away from any40cm. other installation.
- Before to connect the system, check the connections between door panel, power supply, distributors, D-CAM-GB2 camera unit -GB2 monitors ephones ., interface GSM , , tel and audio hands-free units
- U (2x1mm ) .se Golmar cableRAP-2150
- Do always follow the enclosed information.
Introduction....................................................................................................................................................................2
Index..............................................................................................................................................................................2
Starting recommendations............................................................................................................................................ 2.
Safety precautions.........................................................................................................................................................3
Characteristics...............................................................................................................................................................3
System operation...........................................................................................................................................................3
Door panel description (Nexa Modular).............................................................................................................................
Door panel description.................................................................................................................................................4
Sound module description EL632-GB2 / EL642 GB2...................................................................................................5
Push buttons module description (EL610D)................................................................................................................ 6.
Embedding box positioning......................................................................................................................................... 7
Preparing the cables entry........................................................................................................................................... 7
Place the embedding box............................................................................................................................................ 8
Assembly electronic modules...................................................................................................................................... 8
Hold the frame.............................................................................................................................................................9
Plug the push buttons with the sort connection cable....................................................................................................9
Plug the push buttons with the connection cable (RAP-610D)..................................................................................... 10
Push buttons coding...................................................................................................................................................10
Double push button module coding.............................................................................................................................11
Single push button module coding.........................................................................................................................12-13.
Configuration dip-switch.............................................................................................................................................14
Configuration jumper..................................................................................................................................................14
" light conditions" (only module EL632 GB2)...........................................................14Description of the leds lighting low
.................................................................................................14Description of the visual indications on the door panel
Descrip ( ble from ............................................................... 15tion of the vocal synthesis audi indications the door panel).
Adjusting the door panel communication volume........................................................................................................ 15
Adjusting the vocal synthesis volume..........................................................................................................................15
Selecting the vocal synthesis language...................................................................................................................... 16
............................................................................ 16Configuring the contact type for Relay 1 and Relay 2 (door release)
Close the frame.......................................................................................................................................................... 16
Place the nameplate labels.........................................................................................................................................16
Door panel and double door panel assembly..........................................................................................................17-18
Close the door panel...................................................................................................................................................19
Power supply installation (FA-GB2A)............................................................................................................................ 20
Lock release Installation................................................................................................................................................20
Installation diagrams................................................................................................................................................21-30
Notes............................................................................................................................................................................31
2
CHARACTERISTICS
- Video door entrysystem with simplified installation (2 wire bus without polarity).
- Up to 4 access door panel (necessary DP-GB2Adistributor for more than 1 door panel access) per installation.
- Up to 23 monitors and apartmentswith Vesta2monitor per installation(video installationwithtelephonesmax. 23 elements).
- Up to 18 monitors and apartments withThera monitorperinstallation(video installation with telephones max.18 elements).
- Up to 32 telephones and apartments withT562 telephone per installation (onlyaudiosystem).
- Up to 32 audio hands-free Nhea units and apartments per installation (only audio system).
- Up to 4 monitors / telephones per apartment.
- Up to 4 apartments with slave monitors in parallel, per installation.
- Up to 4 monitors in parallel (installation without distributors) per installation.
-Acoustic call acknowledgment signal.
- , i ( , com unica ,Visual indications on the door panel for people with impaired hearing ndicating call progress m tion door open and system busy).
- , indica ( ,Audible indications from the door panel for people with impaired vision ting call is in progress resident unavailable door is open communication is finishedand systemis busy, , ).
- Door opening timed at 1 or 5 seconds.
- 2 output for lock release .s (separateactivation)
- “Relay 1" .Output :a.c or d.c lock release operated by relay
- “Relay 2"Output a.c or d.c lock release operated by relay.
- Input for external door release push button (Relay 1).
- Input for external door release push button (Relay 2).
- Maximum distance between power supply and furthest door panel: 80m with a wire section of 1mm.
- Maximum distance between power supply and istribu : 80m with a wire section 1mm.furthest d tor of
- Max. distance between power supply and furthest telephone (only audio system without distributors): 80m with a wire
section of 1mm.
- Max. distance between distributor and monitor/telephone(video installation withtelephones):40mwith a wire section of 1mm.
SYSTEM OPERATION
3
2
2
2
SAFETY PRECAUTIONS
- ,Install or modify the equipment without thepower connected.
- The installation and handling of these equipments must be performed by authorised personnel.
- The entire installation must be at least 40 cm. away from any other installation.
- With power supply:
wDo not use excessive force when tightening the connector screws. wInstall the power supply in a dry and protected place without risk of drip or water projections. wAvoid to place it near to heating sources, in dusty locations or smoky enviroments. wDo not block ventilation holes of the unit so that air can circulate freely. wTo avoid damage, the power supply has to be firmly fixed. wTo avoid an electrical shock, neither remove the protection cover nor handle the connected wire in the terminals.
- To make a call the visitor should press the push button corresponding to the desired apartment; an acoustic tone will
be heard confirming the call is in progress once the push button has been pressed and the led will turn on. If the vocal synthesis is enabled the message “call is in progresswill be heard confirming the call is in progress. At this moment the apartment´s monitor(s) receives the call. During the call the visitor can correct his call by pressing a push button corresponding to a different apartment, inwhich case the original call is cancelled.
- In systems with several accesses doors, the other(s) door panel(s) will be automatically disconnected: if a visitor tries
to call from other door panel an acoustic tone will be heard and the led will turn on. If the vocal synthesis is enabled the message system is busy, try laterwill be heard confirming the system is busy
- The call lasts for 40 seconds. Without alertingthe visitor, their image is displayed on master monitor toreceive the call.
To view the picture on a slave monitor this function must first be activated in the monitor. If the call is not answered within 40 seconds, the led will turn off and thesystem will be freed.
- To establish communication, press the push button of any monitor (or pick up the handset of any telephone) to the
apartment; door panel led will turn on. If the vocal synthesis is enabledthe message you can speak nowwill be heard confirming the communication is activated.
- Communication will last for one and a half minutes or until the button of the monitor is pressed again (or until the
telephone handset is replaced). Once the communication has finished, the leds and will turn off and the system will be freed. If the vocalsynthesis is enebled, the messagecommunication is finishedwillbe heard in thedoor panel confirming the communication has finished.
- Toopen the door, press the door release push button during call or communicationprogresses: with one press, the
door release operates for 5 seconds, the led will also turn on for 5 seconds. If the vocal synthesis is enabled, the message door is openwill be heard in the door panel.
- For the operation and configuration monitor,see the corresponding monitor manual.
2
DOOR PANEL DESCRIPTION (NEXA MODULAR)
4
Sound module
EL632/GB2 EL642/GB2,
Push buttons electronic module
EL610D
Short connection cable it is supplied with EL610D module length, (16 cm ).
, 5 10 .for single push buttons or double push buttons
, .on video systems with color camera
on audio systems.
Connection cable lengthRAP-610D (27 cm ).
General detail of parts, for assembly the door panel.
Aluminium door panel
Electronic
modules
Frame modulesEmbedding boxes
D .oor panel description
For the connection of the push buttons between the sound module and the push buttons
module EL610D and between push buttons modules EL610D.
For the connection of the push buttons between the sound module and the push buttons
module EL610D and between push buttons modules EL610D.
This cable is necessary when the distance between modules to connecting is greater due to
the distribution of these modules in the door panel(s).
Door panel description:
Grille module:
N1000/AL N1110/AL 1P. N2220/AL 2P.
C : 60xxlosing heads
Push buttons module: 3xxx
Nexa spacer module
Screws of fixation of header (x4)
Lateral rod (x2)
Lateral rod Door panel rodUNE
*
Screws of fixation of embedding box (x2)
*
Door panel UNE rod: It allows to join 2 door panels see a e 18, ( p g ).
SOUND MODULE DESCRIPTION (EL632 GB2 / EL642 GB2):
5
Micr .ophone
Speaker.
Front side.
Sound module push buttons (x2).
Installation terminals GB2( Bus).
Push buttons connector.
Back side.
: Positive, ground (12Vdc output for Golmar 12Vdc lock release). : contact for lock release (Relay 1)"C" . : O contact for lock release (Relay 1)"N. " .
: Input for external door release push button (Relay 1). : N.Ofor lock release (Relay 2). : Ccontact for lock release (Relay 2). : Input for external door release push button (Relay 2). : Input for external call push button (push button 1). : Input for external call push button (push button 2).
: Communication Bus (without polarity).
: Communication Bus (without polarity).
Push button number.
Color camera .(only EL632 GB2 sound module)
+, C1 NA1 AP ,AP+ NA2 C2 AP+,AP P1 P2 BUS BUS
_
Installation terminals:
Not :e .See installation diagrams for wiring (pages 21 to 30)
Configuration dip switch.
Internal use.
Leds (v ).isual indications for people with impaired hearing
Leds (environment low luminosity).
(Only function with EL632 GB2 sound module).
1 2 3 4 5 6
ON
Internal use.
_
_
No modify (i ).nternal use
Sound module description (EL632 GB2 / EL642 GB2):
PUSH BUTTONS MODULE DESCRIPTION (EL610D)
6
Front side.
P (x10).ush buttons module
Configuration dip switch ( ).Push buttons call code
Push button number.
Input output push buttons connector/ (x3).
Back side.
Push buttons module description (EL610D):
DOOR PANEL INSTALLATION
7
1
N V SCE 90C
99
135,5
40
Modules
Model
W
H D
2
CEV90CN
99
238
56
3
CEV90
99 mm.
328 mm.
56 mm.
Break the bottom flange to pass the cables through. In case of door panels
with more than one embedding box, break the side flanges and
.attach the embedding boxes using UC junctions
1650
1850
1450
The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions will depend on the
type of door panel.
The door has been designed to be placed under most of the environmental conditions. However its recommended to
take additional cautions like (covered places, rainproof covers, ...). To obtain a good quality picture on video door entry systems, avoid direct incidence from light sources.
Embedding box positioning:
Preparing the cables entry:
8
Pass the wiring through the hole made in the bottom part of the
embedding box. Level and flush the embedding box. Once the embedding box is placed, remove the protective labels from the attaching door panel holes.
Insert the sound module in the top part of the module frame.
Align the tabs on the sound module in their respective housings of the module frame and then exercise a light pressure until correct placement.
Sound module
EL632/GB2 EL642/GB2
Push buttons module
EL610D
Frame
If there is push buttons module repeat the above process, locating under the sound module, as shown in the drawing.
Frame
Place the embedding box:
Assembly electronic modules:
DOOR PANEL INSTALLATION
9
Hold the frame on the embedding box:
Insert the hinge that it is supplied with the product in the embedding
box, as shown in the drawing.
To hold the frame on the embedding box, insert the hinge in the housings arranged for this purpose in the frame, as shown in the drawing.
The frame can now be folded horizontally facilitating the connection and adjustments in the sound module and push buttons electronic module.
Between push buttons modules EL610D of the same embedding box, insert
the short connection cable of the low connector of the first push buttons module to the top connector of the second push buttons module, as shown in the drawing.
Insert the short connection cable that it is supplied with the product EL610D,
in the push buttons connector of the sound module and the other end of the connection cable in the connector placed in the top part of the push buttons EL610D module, as shown in the drawing.
Between push buttons modules EL610D of different embeddingt boxes,
insert the short connection cable in the low connector of the last module EL610D of the first embedding box and the other end of the connection cable in the middle connector of the last push buttons module EL610D placed in the low part of the second embedding box, as shown in the drawing.
Plug the push buttons with the short connection cable:
1 2 3 4 5 6ON1 2 3 4 5 6
ON
DOOR PANEL INSTALLATION
10
Plug the push buttons with the connection cable RAP-610D:
The push buttons module EL610D must be configured, to assign a call code to
the push buttons. Make this configuration with the dip switch placed in the back side of the module.
Depending on the setting selected, the push buttons are assigned to a specific
call code.
To configure the monitor address call code, it will be necessary to known the call
code of each push button, as shown in the table below.
Important: Select a different configuration option for each module EL610D.
P1- P10: .Push button 1 to push button 10
Not :e " .Sound module, factory set the code 0" n P1 "1" n P2i and i
Use the connection cable RAP-610D, for the connection of the push buttons between
the sound module and the push buttons module EL610D and between push buttons modules EL610D, when the distance between modules to connecting is greater due to the composition of the door panels.
(1)
*
( )
Factory default.
*
( )
Configuration of the push-buttons code:
Push buttons module EL-610D
2
Dip1
1
3
Dip2
Dip3
Dip4
Dip5
Dip6
Dip7
Dip8
Module configuration option
P1
11
31
21
Dip switch
On
Off
Off
Off
Off
On
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
On
On
Push buttons code
P2 P3 P4 P5 P6 P7
2
22
12
3
23
13
4
24
14
5
25
15
6
26
16
7
27
17
8
28
18
9
29
19
10
30
20
P8 P9 P10
(1)
*
( )
2
Dip1
1
4
6
3
5
7
Dip2
Dip3
Dip4
Dip5
Dip6
Dip7
Dip8
P1
1
11
21
31
6
16
26
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
On
Off
Off
Off
On
On
On
On
On
On
On
P3 P5 P7 P9
2
12
22
_
7
17
27
3
13
23
8
18
28
4
14
24
9
19
29
5
15
25
10
20
30
(1)
*
( )
Double push button module coding
Single push button module coding
_ _ _
DOOR PANEL INSTALLATION
11
Double push button module coding:
1 2 3 4 5 6
ON
NA2
+
AP-
C1
NA1
AP+C2AP+AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
1 2 3 4 5 6 7 8
ON
1
2
9 10
7
8
5
6
3
4
1
2
1 2 3 4 5 6 7 8
ON
9 10
7
8
5
6
3
4
1
2
1 2 3 4 5 6 7 8
ON
9 10
7
8
5
6
3
4
1
2
EL632 GB2 / EL642 GB2
EL610D
Code 1 Code 0
Code 10 Code 9
Code 1
Code 10
Code 8 Code 7 Code 8
Code 6 Code 5 Code 6
Code 4 Code 3 Code 4
Code 2 Code 11 Code 2
Code 20 Code 19 Code 20
Code 18 Code 17 Code 18
Code 16 Code 15 Code 16
Code 14 Code 13 Code 14
Code 12 Code 21 Code 12
Code 30 Code 29 Code 30
Code 28 Code 27 Code 28
Code 26 Code 25 Code 26
Code 24 Code 23 Code 24
Code 22 Code 31 Code 22
P1P2 P2
DOOR PANEL INSTALLATION
12
1 2 3 4 5 6
ON
NA2
+
AP-
C1
NA1
AP+C2AP+AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
1 2 3 4 5 6 7 8
ON
1
2
9 10
7
8
5
6
3
4
1
2
1 2 3 4 5 6 7 8
ON
9 10
7
8
5
6
3
4
1
2
1 2 3 4 5 6 7 8
ON
9 10
7
8
5
6
3
4
1
2
EL610D
Code 0
Code 5
Code 4
Code 3
Code 2
Code 1
Code 10
Code 9
Code 8
Code 7
Code 6
Code 15
Code 14
Code 13
Code 12
Code 11
- - - - -
Continue
P1
P2 P2
Single push button module coding:
DOOR PANEL INSTALLATION
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
EL632 GB2 / EL642 GB2
13
1 2 3 4 5 6 7 8
ON
9 10
7
8
5
6
3
4
1
2
1 2 3 4 5 6 7 8
ON
9 10
7
8
5
6
3
4
1
2
1 2 3 4 5 6 7 8
ON
9 10
7
8
5
6
3
4
1
2
Code 25
Code 24
Code 23
Code 22
Code 21
Code 30
Code 29
Code 28
Code 27
Code 26
Code 31
Coming from previous page.
1 2 3 4 5 6 7 8
ON
9 10
7
8
5
6
3
4
1
2
EL610D
Code 20
Code 19
Code 18
Code 17
Code 16
DOOR PANEL INSTALLATION
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
- - - - -
14
Configuration dip switch of the sound module:
1 2 3 4 5 6
ON
+
C1
_
1
The configuration dip switch is located on the left side of the rear part of the module.
1 2
3 4 5 6
ON
Door Panel Address: Dip switches: 1 and 2 OFF (address 1), 1 ON and 2 OFF (address 2), 1 OFF and 2 ON (address3), 1 and 2 ON(address 4).
1 2 4 5 6
3
ON
Set to OFF for door panels with double push buttons and set to ON for door panels with single push buttons.
1 2 3 5 6
4
ON
Set to OFF for door panels to be used in villas and set to ON for use in buildings.
1 2 3 4 6
5
ON
Set to ON to congure the door release time to 5 seconds. Set to OFF to congure the door release time to 1 second
1 2 3 4 5
6
ON
Set to ON to congure: (see page 16)
The vo synthesis language (using the sound module's P1 push button).cal The door release Relay 1 and Relay 2 to N.O or N.C (using the sound module's P2 push button). Set to OFF when conguring is complete.
Description of the configuration jumper:
1 2 3 4 5 6
ON
+
C1
_
1
Important: .Do not change the factory default position of the configuration jumper
Description of the door panel LED lights ):"low light conditions" (only EL632 GB2 module
The door panel LED lights will turn on during a call if there is low light, allowing the
person who called to be seen on the apartment's monitor.
*
( )
*
( )
Factory default.
Description of the visual indications on the door panel:
Visual indications on the door panel for people with impaired hearing:
- led .While calling: The will turn on during the call and while in communication
- ledDuring communication: The will turn on during the communication process.
- ledDuring door release: The will turn on during door release.
- ledsEnd of communication: The and will turn o.
- withCalling at one door panel while another door panel is communicating ( more than one door panel): The led .will turn on for 3 seconds
- ledWhile calling and the monitor is in (do not disturb) mode: The will turn on for 4 seconds.
- ledWhile calling (apartment with no monitor or telephone): The will turn on for 4 seconds.
*
( )
*
( )
Factory default.
*
( )
*
( )
*
( )
*
( )
*
( )
DOOR PANEL INSTALLATION
15
Description of the voc synthesis (audible indications from the door panel)al :
Audible indications from the door panel for people with impaired vision. If the voc in the sound module is activated (see pages 14 and 16 to congure), a voice with theal synthesis
following messages can be heard from the door panel:
- is in progress .While calling: Call
- Start communication: You can speak now.
- is .During door release: Door open
- ommunication is nishedEnd of communication: C .
- withCalling at one door panel while another door panel is communicating ( more than one door panel): .System is busy, try later
- Resident unavailable .While calling and the monitor is in "Do not disturb" mode:
- Resident unavailable.While calling (apartment with no monitor or telephone):
Adjusting the door panel communication volume:
If after starting the system the door panel audio volume seems inadequate, follow these steps:
- .Call an apartment
- The call is received in the apartment. Establish communication by pressing the push button on the monitor.
- sameNext, press the push button used to call the apartment for 3 seconds until a series of conrmation tones are heard and the door panel communication starts toblink.leds
- ledEach press on the same call push button will increase the door panel volume and the 's blink speed.
.
There are 5 volume settings and the blink speed will vary for each. Slow to fast blink - low to highleds volume. After reaching setting 5, that is maximum blink speed and volume, the next setting is setting 1, that is minimum blink speed and volume (carousel mode).
- To save the volume setting keep the same push button used to call the apartment pressed until a series of conrmation tones are heard and the door panel communication LED turns o.
Adjusting the voc synthesis volumeal :
If after starting the system the voc synthesis volume of the door panel seems inadequate, follow these stepsal :
- .Within 10 seconds of connecting power to the door panel press any call push button on the door panel
- ledKeep the call push button pressed until the synthesis volume is heard and the door panel communication
starts to blink.
- .Each press on the same call push button will increase the synthesis volume and the LED's blink speed There are 5 volume settings and the LED's blink speed will vary for each. Slow to fast blink - low to high volume.After reaching setting 5, that is maximum blink speed and volume,the next setting is “setting 1, that is minimum blink speedand synthesis volume (carouselmode).
- To save the volume setting keep the same push button used to call the apartment pressed until a series of conrmation tones are heard and the door panel communication LED turns o.
DOOR PANEL INSTALLATION
16
Once finished the works of wiring, configuration and
adjustments, fix the frame in the embedding box with the supplied screws.
Close the frame:
Important: Before closing the door panel(s), make a
test call to any apartment to ensure that it works correctly.
Selecting the vo synthesis languagecal :
To activate the voice synthesis of the door panel, follow these steps:
- Set dip 6 of the sound module's conguration dip switch to ON (see page 14), a conrmationtone will be heard.
- The desired language can be set using the sound module's P1 push button.
- Each press will change the language. Continue doing this until the desired language is heard.
- Once nished set dip 6 on the conguration dip switch to OFF. A conrmation tone will be heard
P1
Configuring the contact type for Relay 1 and Relay 2 (door release):
To change the contact type for door release activation of Relay 1 and Relay 2 of the
door panel, follow these steps:
- Set dip 6 of the sound module's conguration dip switch to ON (see page 14), a conrmation tone will be heard.
- Use the sound module's P2 push button to select the desired contact type (N.O factory default or N.C).
- Each press will change the contact type. A long conrmation tone will be heard if the selected contact is N.O or two short tones if the selected contact is N.C.
Stop pressing P2 when the desired tone is heard.
- Once nished set dip 6 on the conguration dip switch to OFF. A conrmation tone will be heard.
P2
Place the nameplate labels:
Open the label holder.
Place the label
.and close
Important: The selected contact type will apply to both Relay 1 and Relay 2.
Description:
Normally open: N.O Normally closed: N.C
DOOR PANEL INSTALLATION
17
Door panel assembly:
Insert a header in the lateral rods (at the bottom part) and fix it with the supplied screws (step 1 ), then insert the
module (step 2 ). Ifthe door panel is more than one module insert first the lower module, see picture A .
Place the spacer module (step 3 ) and insert the next module (step 4 ) see picture B . Repeat this procedure in case of door panels with one more module (the maximum number of modules placed vertically is three).
To finish insert the second header (step 5 ) in the lateral rods (at the top part) and fix it with the supplied screws, see picture C .
2,9 x 13
DIN-7981
A B C
1
2
3
4
5
Lateral rod
Lateral rod
2,9 x 13
DIN-7981
DOOR PANEL INSTALLATION
18
Double door panel assembly:
Assembly the door panel step , as it is described in page 17 door panel assembly. Bear in mind that the rodA ( 1 ) " that will join the door panel and the door panel have to be of the type door panel rod see picture belowA B UNE , .
I a header between door panel rod and the second lateral rod at the bottom part and fix it with thensert UNE ( ) supplied screws step , then insert the module step If the door panel is more than one module insert first the( 2 ) ( 3 ). lowermodule.
Placethe spacermodule step and insert the next module step Repeat this procedurein case of door panels( 4 ) ( 5 ). with one more module the maximum number of modules placed verticallyis three( ). To finish insert the last header between door panel rod and the second lateral rod at the top part and fix it withUNE ( ) the suppliedscrews step( 6 ).
Lateral rod
A
Door panel
UNE rod
A
B
5
1
2
4
3
6
Door panel
UNE rod
Lateral rod
Lateral rod
IMPORTANT: (Once finished the adjustments, stick the adhesive gasket that it is supplied with the set of closing
heads in the door panel rod.N60XX CMPL) UNE
2,9 x 13
DIN-7981
2,9 x 13
DIN-7981
DOOR PANEL INSTALLATION
19
Close the door panel:
Fix the door panel in the embedding box with the supplied screws.
Door panel: Do ble :u door panel
Finish the door panel assembly by placing the closing heads put the head on one side and then make a slight,
pressure on the other end to itscorrect placement, .
DOOR PANEL INSTALLATION
20
Installing the FA-GB2/A power supply:
M 4 x 8
3,5 x 25
DIN-7972
DIN-963
Replace the protection cover once the input terminals have been wired.
It's recommended to protect the power supply by using a
thermo-magnetic circuit breaker. Use a ground connection with FA-GB2/Apower supply.
Mount the din rail to the wall with wallplugs and screws
that are supplied with power supply. Next, place the power supply simply pressing it.
The power supply can be installed on a .DIN 46277
.
To disassemble the power supply from the DIN rail, use a plain
screwdriverto lever the flange as shown on the picture.
The GB2/A model uses 8units over DIN railFA- .
FA-IMPORTANT: The maximum number of units that can be connected to a GB2/A power supply is 23
monitors VESTA2 GB2" or18 monitors THERA GB2".
Installthe power supply in a dry and protectedplace without risk of drip or water projections. To avoid an electrical shock, neither remove the primary protection cover nor handle the connected wire in the
terminals.
The installation and handling of these equipments must be performed by and withoutauthorised personnel
the power connected.
To avoid damage, the power supply has to be firmly fixed.
IMPORTANT:
- The lockrelease must be of (Golmar) d.c or a.c.12V See page 2130 (a.c lock release) and ages to 30 (d.c lock releasep ).
- Two varistors are supplied with the sound module. In case to connect an a.c. lock release, place the varistor on the lock release terminals directly to ensure a proper system operation.
If the lock release will be installed in a metal door, use a . drill andØ3,5mm
tap the hole In caseof wood door se a drill.. , u Ø3mm.
Installing the lock release:
LOCK RELEASE INSTALLATION
Din rail.
Din rail.
Din rail.
DIN rail latch release.
POWER SUPPLY INSTALLATION
DIN 46277
INSTALLATION DIAGRAMS
Video installation with 3 VESTA2 6 DP-GB2A tors and 12Vd.c lock release:2 monitors, distribu Golmar
21
Configuring the end of line in the last monitor. Dip 6 On.to
Access door panel
Lock release
m x. 12 V c/270mA.a d
Main
100~240Vac
End of line
End of line
Configuring the end of line in the last distributor. Switch to On.
Distances and Sections:
Twisted 2x0.75mm
Twisted 2x1mm
60mA60mB30m
C
80m 80m 40m
Cable
2
2
10m
D
15m
BUS
BUS
BUS
BUS
BUS
BUS
BUS BUS
D
C
B
A
DP- 2GB A
BUS
BUS
BUS
ON
OFF
C 3ODE C 2ODE
C DO E 1 C 0ODE
CODE 22
CODE 21 CODE 20
AP
DP-GB2A
A
C
B
C
(1)
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
ON
1 2 3 4 5 6
SW1
(1)
BUS
BUS
BUS BUS
D
C
B
A
DP- 2GB A
D
VESTA2
FA- 2GB /A
VESTA2
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
Important:
For connection of 12Va.c lock release or a 2nd lock release, (see page 30). For more information of the monitor, see quick guide enclosed with the VESTA2 monitor.
(1)
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
**
( )2 ( )
**
( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
( )2
*
( )
*
( )
Video installation with 23 VESTA2 monitors, 12 D2L-GB2 distributors and 12Vd.c lock release:Golmar
22
Configuring the end of line in the last monitor. Dip 6 On.to
Access door panel
Lock release
m x. 12 V c/270mA.a d
Main
100~240Vac
End of
l nei
Take off jumper of all the distributors except in the last one.
Do not change the factory default position of the configuration jumper.
End of
l nei
End of
l nei
Distances and Sections:
Twisted 2x0.75mm
Twisted 2x1mm
60mA60mB30m
C
80m 80m 40m
Cable
2
2
10m
D
15m
INSTALLATION DIAGRAMS
BUS
BUS
BUS BUS
D2
D1
D2L- 2GB
BUS
BUS
BUS
BUS
BUS BUS
D2
D1
D2L-GB2
BUS
ON
C 3ODE C 2ODE
BUS
BUS
BUS BUS
D2
D1
D2L- 2GB
BUS
BUS
C 1ODE C 0ODE
(1)
OFF
(1)
OFF
(1)
(1)
D2L- 2GB
CODE 22
A
C
B
C
D
VESTA2
FA- 2GB /A
VESTA2
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
ON
1 2 3 4 5 6
AP
SW1
(2)
(2)
( )2
Important:
For connection of 12Va.c lock release or a 2nd lock release, (see page 30). For more information of the monitor, see quick guide enclosed with the VESTA2 monitor.
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
( )3
**
( )
( )3 ( )3
**
( )
**
( )
( )3 ( )3
**
( )
**
( )
( )3**( )
*
( )
*
( )
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
23
Video installation with telephones: Up to 23 elements (Vesta2 monitors / T562 telephones), 6 DP-GB2A distributors and 12Vd.clock release:Golmar
Configuring the end of line in the last monitor or telephone. Monitor: toDip 6 On. Telephone: Dip 11 to On.
Access door panel
BUS
BUS
BUS
BUS
BUS
BUS BUS
D
C
B
A
DP- 2GB A
BUS
BUS
End of line
ON
End of line
OFF
C 3ODE C 2ODE
C 1ODE C 0ODE
CODE 21
CODE 20
Configuring the end of line in the last distributor. Switch to On.
AP
Distances and Sections:
DP-GB2A
A
C
B
C
(1)
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
ON
1 2 3 4 5 6
SW1
(1)
BUS
BUS
BUS BUS
D
C
B
A
DP- 2GB A
D
FA- 2GB /A
VESTA2
Main
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
Important:
For connection of 12Va.c lock release or a 2nd lock release, (see page 30).
For more information of the monitor and telephone, see quick guide enclosed with the VESTA2 monitor and T562 telephone.
(1)
T-562 Slave 1
CODE 21
Additional telephone (in the same apartment)
T-562 Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
T562
L1 L2
L1 L2
**
( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
( )2
( )2
*
( )
*
( )
**
( )2 ( )
INSTALLATION DIAGRAMS
Twisted 2x0.75mm
Twisted 2x1mm
60mA60mB30m
C
80m 80m 40m
Cable
2
2
10m
D
15m
Lock release
m x. 12 V c/270mA.a d
24
INSTALLATION DIAGRAMS
Video installation with 18 THERA 5 DP-GB2A tors and 12Vd.c lock release:monitors, distribu Golmar
Configuring the end of line in the last monitor. Dip 6 On.to
Access door panel
BUS
BUS
BUS BUS
D
C
B
A
End of line
ON
End of line
OFF
Configuring the end of line in the last distributor. Switch to On.
Distances and Sections:
FA- 2GB
DP-GB2A
THERATHERA
A
C
B
C
BUS
BUS
BUS BUS
D
C
B
A
D
Twisted 2x0.75mm
Twisted 2x1mm
60mA60mB30m
C
80m 80m 40m
Cable
2
2
10m
D
15m
BUS
BUS
BUS
BUS
BUS
BUS
C 3ODE C 2ODE
C 1ODE C 0ODE
C 1ODE 7 C 1ODE 6
FA- 2GB /A
Abrepuertas
máx. 12 Vcc/270mA.
AP
(1)
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
ON
1 2 3 4 5 6
SW1
(1)
Main
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
THERA
Master
THERA
Master
THERA
Master
THERA
Master
THERA
Master
THERA
Master
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )
*
( )
*
( )
DP- 2GB A
DP- 2GB A
(1)
Important:
For connection of 12Va.c lock release or a 2nd lock release, (see page 30). For more information of the monitor, see quick guide enclosed with the THERA monitor.
( )2
BUS
BUS
C 3ODE C 2ODE
BUS
BUS
C 1ODE C 0ODE
Distances and Sections:
D2L- 2GB
A
C
B
C
D
THERATHERA
25
Video installation with 18 THERA 9 D2L-GB2 tors and 12Vd.c lock release:monitors, distribu Golmar
INSTALLATION DIAGRAMS
Configuring the end of line in the last monitor. Dip 6 On.to
Access door panel
Lock release
m x. 12 V c/270mA.a d
BUS
BUS
BUS BUS
D2
D1
D2L- 2GB
BUS
BUS
BUS BUS
D2
D1
D2L-GB2
End of
l nei
ON
Take off jumper of all the distributors except in the last one.
BUS
BUS
BUS BUS
D2
D1
D2L- 2GB
Do not change the factory default position of the configuration jumper.
(1)
OFF
End of
l nei
OFF
End of
l nei
Twisted 2x0.75mm
Twisted 2x1mm
60mA60mB30m
C
80m 80m 40m
Cable
2
2
10m
D
15m
(1)
(1)
(1)
( )2
BUS
BUS
CODE 17 CODE 16
FA- 2GB /A
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
ON
1 2 3 4 5 6
AP
SW1
(2)
(2)
Main
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
Importante:
For connection of 12Va.c lock release or a 2nd lock release, (see page 30). For more information of the monitor, see quick guide enclosed with the THERA monitor.
THERA
Master
THERA
Master
THERA
Master
THERA
Master
THERA
Master
THERA
Master
( )3
**
( )
( )3
**
( ) ( )3**( )
( )3**( ) ( )3**( )
( )3**( )
*
( )
*
( )
( )3
**
( )
Video installation with audio hands-free: Up to 18 elements (THERA monitors / NHEAhands-free): 5 GB ADP- 2 distributors and 12Vd.c lock release:Golmar
BUS
BUS
BUS
BUS
BUS
BUS
BUS BUS
D
C
B
A
DP- 2GB A
End of line
ON
End of line
OFF
C 2ODE
C 1ODE C 0ODE
C 1ODE 6
Distances and Sections:
DP-GB2A
A
C
B
C
(1)
BUS
BUS
BUS BUS
D
C
B
A
DP- 2GB A
D
THERA
FA- 2GB /A
Access door panel
AP
(1)
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
ON
1 2 3 4 5 6
SW1
(1)
Main
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
Importante:
For connection of 12Va.c lock release or a 2nd lock release, (see page 30).
For more information of the monitor and telephone, see quick guide enclosed with the THERA monitor and NHEA hands-free.
C 3ODE
**
CODE 16
Additional audio hands-free (in the same apartment)
NHEA Master
THERA
Master
BUS
NHEA Slave 1
THERA
Master
THERA
Master
THERA
Master
AUX
NHEA
AUX
AUX
( )2
( )2 ( )
**
( )2 ( )
**
( )2 ( )
**
( )2 ( )
( )2
**
( )2 ( )
**
( )
*
( )
*
( )
26
INSTALLATION DIAGRAMS
Twisted 2x0.75mm
Twisted 2x1mm
60mA60mB30m
C
80m 80m 40m
Cable
2
2
10m
D
15m
Configuring the end of line in the last monitor or audio hands-free. Monitor: toDip 6 On. Audio hands-free: Dip 11 to On.
Configuring the end of line in the last distributor. Switch to On.
Lock release
m x. 12 V c/270mA.a d
BUS
27
INSTALLATION DIAGRAMS
Audio installation with 32 apartments / T562 telephones and
Golmar 12Vd.c lock release:
Access door panel
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
Abrepuertas
máx. 12 Vcc/270mA.
ON
1 2 3 4 5 6
AP
SW1
C 0ODE
*
( )
*
( )
Distances and Sections:
A
C
B
L1
L2
CODE 1
L1
L2
CODE 31
L1
L2
APARTMENT 1
APARTMENT 2
APARTMENT 32
Importante:
For connection of 12Va.c lock release or a 2nd lock release, (see page 30).
( )
*
FA- 2GB /A
Main
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
For more information of the telephone, see quick guide enclosed with the T562 telephone.
1
( )
1
( )
1
( )
1
( )
Twisted pair 2x0.75mm
Twisted pair 2x1mm
60mA60m
B
80m 80m
Cable
2
2
10m
C
15m
T562
T-562 GB2
Master
T562
T-562 GB2
Master
T-562 GB2
Master
Audio installation with 32 apartments / NHEA hands-free units and Golmar 12Vd.c lock release:
Access door panel
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
Abrepuertas
máx. 12 Vcc/270mA.
ON
1 2 3 4 5 6
AP
SW1
C 0ODE
*
( )
*
( )
Distances and Sections:
A
C
B
CODE 1
CODE 31
APARTMENT 1
APARTMENT 2
APARTMENT 32
28
Importante:
For connection of 12Va.c lock release or a 2nd lock release, (see page 30).
( )
*
FA- 2GB /A
Main
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
For more information of the audio hands-free unit, see quick guide enclosed with the NHEA hands-free.
1
( )
1
( )
1
( )
1
( )
AUX
NHEA
AUX
NHEA
INSTALLATION DIAGRAMS
Twisted pair 2x0.75mm
Twisted pair 2x1mm
60mA60m
B
80m 80m
Cable
2
2
10m
C
15m
NHEA
Master
AUX
NHEA
Master
AUX
NHEA
Master
AUX
BUS
BUS
BUS
29
BUSBUS
BUS BUS
D C B A
DP- 2GB A
End of line
OFF
AP AP
Access door panel 2
ON
1 2 3 4 5 6
SW1
Access door panel 1
ON
1 2 3 4 5 6
SW1
AP AP
Access door panel 3
ON
1 2 3 4 5 6
SW1
Access door panel 4
ON
1 2 3 4 5 6
SW1
(1) (1)
(1) (1)
Video installation: To distributors buiding’s floor( )
: To telephones (buidings floor)Audio installation
Lock release
m x. 12 V c/270mA.a d
Lock release
m x. 12 V c/270mA.a d
Lock release
m x. 12 V c/270mA.a d
Lock release
m x. 12 V c/270mA.a d
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2
Relé 1
_
12Vdc
Important: .For connection of 12Va.c lock release or a 2nd lock release, (see page 30)
(1)
(1)
(1)
(1)
(1)
Video installation with access doors GB2A distributor for door panels and 12Vd.c lock4 , DP- Golmar
INSTALLATION DIAGRAMS
Main
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
Video installation: Placed to OFF the end of line.
: Set to ON the end of line.Audio installation
( )
*
Important: (in this distributor).
( )
*
30
Access door panel
ON
1 2 3 4 5 6
SW1
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2Relé 1
_
12Vdc
AP1
Access door panel
ON
1 2 3 4 5 6
SW1
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2Relé 1
_
12Vdc
Co nexi n 2 "AP":n o of d.c locks release without
Important: 2 .Do not use the APpush buttons door release if there are connected d.c locks release
(1)
To GB /A power supplyFA- 2
Main
230Vac
SEC
~~ ~~
PRI
TF-104
Lock release
m x. 12 Va /850mA.a c
Locks release
m x. 12 Va /850mA.a c
Con exi n 1 "AP":n o of a.c lock release with
To GB /A power supplyFA- 2
Access door panel
ON
1 2 3 4 5 6
SW1
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relé 2Relé 1
_
12Vdc
(1)
To GB /A power supplyFA- 2
(1)
Locks release
m x. 12 V c/270mA.a d
Con exi n 2 "AP":n o of a.c locks release with
SEC
~~ ~~
PRI
TF-104
AP1 AP2
Main
230Vac
Con exi nn o of d.c and .c Golmar locks releasea .
INSTALLATION DIAGRAMS
Importante: Place the varistor supplied with the sound module on the lock release terminals directly to ensure a proper system operation.
( )
*
Importante: Place the varistors supplied with the sound module on each lock release terminals directly to ensure a proper system operation.
( )
*
( )
*
( )
*
( )
*
31
NOTES:
golmar@golmar.es
www.golmar.es
Sistemas de comunicaciónS.A.
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
GOLMAR S.A.
C/ Silici, 13
08940- Cornellá de Llobregat
SPAIN
Loading...