golmar SV805AL Instruction Manual

T805ML
rev.0204
Video Kit
5 wires installation
without coax
Instructions manual
Rock Series
nstalling the FA-805 power supply.
I
2
SYSTEM OPERATION
STARTING RECOMMENDATIONS
3
POWER SUPPLY INSTALLATION
DIN 46277
f3,5 x 50
DIN-7971
f3,5 x 50 DIN-7971
LOCK RELEASE INSTALLATION
If the lock release will be installed in a metal door, use a Ø3,5mm. drill and tap the hole. In case of wood door, use a Ø3mm. drill.
IMPORTANT: the lock release to be used must be 12Va.c.
M 4 x 8
f3,5 x 25
DIN-7972
DIN-963
O Do not use excessive force when tightening the power supply connector screws. O Install the equipment wit the power disconnected. Disconnect from power before any
system modification.
O Before to connect the system, check the connections between door panel,
INTRODUCTION
First of all we would like to thank and congratulate you for the purchase of this
product manufactured by Golmar.
The commitment to reach the satisfaction of our customers is stated through the
ISO-9001 certification and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers. To obtain the maximum profit of these features and a properly wired installation, we kindly recommend you to expend a few minutes of your time to read this manual.
SYSTEM CHARACTERISTICS
O O O O O O
Video system with 5 wires installation (without coaxial cable). Weatherproof (IP-44) and vandal resistant (IK-09) door panel. Electronic call with acoustic acknowledgement signal. Autoswtich-on function (it requires one extra wire on the installation). Potential free contact push buttons to activate auxiliary devices. a.c. lock releases activation.
O Two additional telephones can be placed in parallel (T-901 and T-901VD models).
ock release
L
installation.
To install the power supply directly on the wall, drill two holes of Ø6mm. and insert the wallplugs. Fix the transformer with the specified screws.
The power supply must be installed in a dry and protected place. It's recommended to protect the power supply by using a thermo-magnetic circuit breaker and to use a ground connection.
O To make a call the visitor should press the push button corresponding to the
apartment he wishes to contact. An acoustic tone will be heard confirming the call is in progress once the push button has been pressed. At this moment the call will be received at the monitor (telephone) in the dwelling and the picture will appear on the monitor without the visitor being aware of this.
O To establish communication pick up the monitor (telephone) handset. The
communication will last for one and a half minutes: if the handset is replaced before, the picture will remain on the screen till the end of this time.
O To open the door, press the door release push button. O To see the picture from the door panel, without being called first, press the
autoswitch-on push button. Pick up the handset and press the autoswitch-on push
5
4
If after starting the system it's considered that the audio volume isn't correct, proceed with the necessary adjustments as shown. The telecamera has a pan and tilt mechanism built in to adjust the telecamera position.
DOOR PANEL INSTALLATION
DOOR PANEL INSTALLATION
1650
1850
1450
mbedding box positioning.
E
The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions are: 131(W) x 131(Al) x 45(D) mm.
The door panel has been designed to be placed under most of the environmental conditions. However it's recommended to take additional cautions like rainproof covers. To obtain a good quality picture on video door entry systems, avoid direct incidence from light sources.
Break the bottom flange to pass the cables through.
Pass the wiring through the hole made in the bottom part of the embedding box. Level and flush the embedding box. Once the embedding box is placed, remove the protective labels from the attaching door panel holes.
reparing the
P
embedding box.
inal
F
adjustments.
lose the door panel.
C
Fix the door panel by using the supplied screws.
6
Allows the activation of an auxiliary device (see page 34).
If the handset is on the craddle allows to see the picture from the panel camera. If not, allows to establish audio and video communication with the door panel. This function will last for one and a half minutes. The activation of this function requires one extra wire.
Allows to activate the lock release.
unction push buttons.
F
a
g
b
f
j
i
e
c
h
a. b. c. d. e. f . g. h. i. j . k.
d
k
7
MONITOR INSTALLATION
A2
I
Colocar la parte superior de la regleta a 1,60m. del suelo.
Place the top part of the monitor connector at 1,60m. from the floor.
50mm.
50mm.
Presionar para abrir.
Press to open.
a
a
b
b
f
e
d
c
VP
MP
AM
U
A1
B1
B2
MONITOR DESCRIPTION MONITOR CONNECTOR DESCRIPTION
escription of the Platea 5
D
monitors.
Handset. B/W or color screen (depending on the model). Front film. No operation push buttons. Function push buttons. Cord. Attachment holes. Connecting points. Cable slot. Contrast control (color on Platea 5 Color). Brightness control.
escription of the monitor
D
connector.
a. Wall attachment hole (x4). b. Monitor attachment hook (x2). c. Vertical wiring input. d. Attachment clip. e. Wiring input hole. f. Installation terminals:
Avoid to place the monitor near to heating sources, in dusty locations or smoky environments. To install the monitor directly over the wall, drill two holes of Ø6mm. and use the supplied screws.
The upper part of the monitor connector must be placed at 1,60m. height roughly. The minimum distance between the monitor connector and the closest object must be 5cm.
ix the monitor connector to the
F
wall.
8
9
a
d
c
e
b
e
g
f
On-Off and call volume regulator (only on T-901VD telephone).
Place the monitor at right angles to the connector and align the attaching holes of the monitor with the attachment hooks of the connector, as it is shown on the drawing.
Lock out the monitor. Press the right side till the attachment clip locks the monitor firmly.
To disassemble the monitor from the connector, use a plain screwdriver to release the attachment clip. Remove the monitor from the connector, with special attention do not falls.
ix the monitor.
F
MONITOR INSTALLATION
hanging the front film.
C
The monitor is supplied with a reversible front film, that allow the owner to choose between two colors. To change the front film, remove the front plate by inserting a plain screwdriver in the triangle marks, as it is shown on the drawing.
a. b. c. d. e.
f.
g.
Telephone handset. Speaker grille. Microphone hole. Subjection hole. Telephone cord connectors. Door release push button. Hook switch.
escription of the T-901 and T-
D
901VD telephones.
To open the telephone insert a plain screwdriver into the slots and rotate it as shown. Avoid to place the telephone near to heating sources, in dusty locations or smoky environments. The telephone can be fixed using an electrical embedding box or directly on the wall, as shown on the picture. If the telephone will be installed directly over the wall, drill two holes of Ø6mm. on the specified positions, using 6mm. wallplugs and Ø3,5 x 25mm. screws.
Pass the installation wires through the corresponding hole and connect them as shown on the installation diagrams.
Close the telephone as shown on the picture. Once the telephone is closed, connect the handset using the telephone cord and put it on the craddle.
TELEPHONE INSTALLATION
11
FA-805
SEC
PRI
Main
+
-
C2C1 I+
CN1
-
~1 ~1~2 ~2
0 110 220
-
A1 AM Vp Mp
Mp VpU AM I A1A2 B1 B2
-
10
S-45
CA1 2S+ S-
Platea 5
T-901 T-901VD
C2C1
~1~2
Dotted lines show the additionnal connections for autoswitch-on function activation.
Platea 5 monitors have two potential free contact push buttons ( and ) to activate auxiliary devices. If autoswitch-on function has been installed, it will be only possible to use push button (terminals B1 and B2) to activate one auxiliary device. The maximum load to be applied to one of these push buttons is 200mA/50Vd.c. However, it's recommended the use of R-3 unit relays and one TF-104 transformer. Usual applications are the activation of stairs light, second lock release, ...
Mp VpU AM I A1A2 B1 B2
-
Platea 5
MRBO T
R-3
TF-104
SEC
~~
ections chart.
S
–, + 1,50mm² 2,50mm²
1,00mm² 1,50mm²
Power supply / Panel / Lock release50m.
Distance
100m.
~1, ~2, C1, C2
I 0,25mm² 0,50mm² 1,00mm²
1,00mm² 1,50mm² 2,50mm²
0,25mm² 0,25mm² 0,25mm²*
Door panel / Monitor 50m.
Distance
100m. 200m.
–, AM
Vp, Mp, A1
* For longer distances than 100m., Vp and Mp video wires must be twisted.
INSTALLATION DIAGRAMS
INSTALLATION DIAGRAMS
ne access door.
O
uxiliary devices activation.
A
The total amount of call repeaters and telephones placed in the same apartment is two. For each item placed in parallel the section corresponding to the I, 2 and S+ wires must be doubled.
ock release activation using an external push
L
button.
The lock release can be activated at any moment by using an external push button, that must be connected between terminals. This function will allows to exit from the building being not necessary the use of a key.
'C2' and '~1'
Loading...