golmar Plus Nexa Instruction Manual

Plus Nexa
Code 50122328
Instructions manual
Audio and Video
door entry system
(One or several
accesses doors /
General door panel)
T632 PLUS NP/T E rev.0118
73
INTRODUCTION
STARTING RECOMMENDATIONS
INDEX
First of all we would like to thank and congratulate you for the purchase of this product manufactured by Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers. To obtain the maximum profit of these features and a properly wired installation, we kindly recommend you to expend a few minutes of your time to read this manual.
O Do not use excessive force when tightening the power supply connector screws. O The entire installation must be at least . away from any .40cm other installation O Before to connect the system, check the connections between door panel,monitors, telephones, and
the transformer connection. Do always follow the enclosed information.
O Each time thepower supply isrestarted, or after a modification, the system will remainblocked during
30 seconds.
O Always use coaxial cables, (see page 94).RG-59 B/U MIL C-17 or RG-11 Never use coaxial
antenna cable. Golmar RAP-5130In installations no longers than 100m., cable can be used.
Introduction ...........................................73
Index.....................................................73
Starting recommendations .......................73
Safety precautions...................................74
System characteristics ..............................74
Important notice .....................................75
System operation ....................................75
Door panel description ............................76
Modules description....................................
Sound moduleEL632 Plus P/T.................77
Sound moduleEL642 Plus ......................77
Pushbuttons module EL610D.................78
Door panel ................................................
Embedding box positioning ...................79
Embedding box installation ..............79-80
Assembly electronic modules .................80
Hold the Frame ....................................81
Pushbuttons connection...................81-82
Pushbuttons coding..............................82
Descrip i n con ector.............83t o Bus Nexa n
Con e ............83n ctionillumination module
Descrip ..................84tion illumination leds
Descrip .................84tion visual indications
Sound module configuration ............85-86
Programming(general panel) ...........87-89
Description Cn3 connector....................89
Finaladjustments .................................90
Place the nameplate labels ....................90
Door panel assembly ............................91
Close the door panel.............................91
Powersupply installation ..........................92
Lock release installation...........................92
Installation diagrams...................................
Video installation with coaxial ...........93-94
Video installation without coaxial.......95-96
Audio installation ............................97-98
Video installtion (general panel) ......99-102
Audio installation (general panel) ..103-104
Connection of an a.c. lock release ........105
Link of several power supplies...............105
Optional connections..................................
External lock release activation.............106
ConnectionsynthesevocalemoduleFDI..106
Troubleshooting hints ............................107
Notes...........................................108-110
Compliance.........................................111
74
O Audio and video door entry system with simplified installation:
O Sound module ( )with two operating modes EL500 or EL501 . O Sound module EL632 Plus P/T with pan and tilt mechanism to adjustthe telecamera position. O BusNexa: ( , manual )It allows the connection of illumination module coded panel see TCode/C NexaA
O Unlimited number of door panels (access) being not necessary the use of switching units. O Up to 120 monitors/telephones per installation or backbone. O General door panel (EL501 mode): Up to 120 monitors/telephones,distributedin max.120 buildings. O EL560 module for videoinstallations with twisted paircable, integratedin sound module. O Communications resistor for the system UNO orPLUS,integratedin sound module. O Acoustic busy channel and call acknowledgement signals. O Door opening timed at 3 seconds. O Input for external door release push button (timed at 3 or 15 seconds). O a.c or d.c lock release operated by relay. O Up to three monitors or telephones in the same apartment without additional power supplies. O Monitor Tekna Plus SE:
O TelephoneT540 PlusSE:
O TelephoneT540 Uno SE:
O Install or modify the equipment .without the power connected O The installation and handling of these equipments must be performed by .authorisedpersonnel O The entire installation must be at least . away from any .40 cm other installation O With power supply:
O With monitor, telephones and distributor:
O Remember, the installation and handling of these equipments must be performed by authorized
O Do always follow the enclosed information.
74
SAFETY PRECAUTIONS
SYSTEM CHARACTERISTICS
O Audio and video door entry system with simplified installation:
wAudio door entry system with 4 common wires installation. wVideo door entry system with 3 common wires plus coaxial cable installation.
wVideo door entry system with 4 common wires plus twisted pair installation. O Sound module ( )with two operating modes EL500 or EL501 . O Sound module EL632 Plus P/T with pan and tilt mechanism to adjustthe telecamera position. O BusNexa: ( , manual )It allows the connection of illumination module coded panel see TCode/C NexaA
(NFCmodule, see manual ).TCode/CA NFC Nexa
O Unlimited number of door panels (access) being not necessary the use of switching units. O Up to 120 monitors/telephones per installation or backbone. O General door panel (EL501 mode): Up to 120 monitors/telephones,distributedin max.120 buildings. O EL560 module for videoinstallations with twisted paircable, integratedin sound module. O Communications resistor for the system UNO orPLUS,integratedin sound module. O Acoustic busy channel and call acknowledgement signals. O Door opening timed at 3 seconds. O Input for external door release push button (timed at 3 or 15 seconds). O a.c or d.c lock release operated by relay. O Up to three monitors or telephones in the same apartment without additional power supplies. O Monitor Tekna Plus SE:
Description,installation,configurationand programming of themonitor (see manualTTEKNA PLUS SE "Code 50123594")availablein:
https://doc.golmar.es/search/manual/50123594.
O TelephoneT540 PlusSE:
Description, installation,configuration and programming of the telephone(seemanualT540 PLUSSE "Cód.50122199") disponible en:
https://doc.golmar.es/search/manual/50122199.
O TelephoneT540 Uno SE:
Description,installation, configuration and programmingof the telephone (see manual T540 UNO SE "Cód. ") disponibleen:50122257
https://doc.golmar.es/search/manual/50122257
O Install or modify the equipment .without the power connected O The installation and handling of these equipments must be performed by .authorisedpersonnel O The entire installation must be at least . away from any .40 cm other installation O With power supply:
wDo not use excessive force when tightening the connector screws.
wInstall the power supply in a dry and protected place without risk of drip or water projections.
wAvoid to place it near to heating sources, in dusty locations or smoky enviroments.
wDo not block ventilation holes of the unit so that air can circulate freely.
wTo avoid damage, the power supply has to be firmly fixed.
wTo avoidan electrical shock, neither remove the protection cover nor handle the connectedwire in
the terminals.
O With monitor, telephones and distributor:
wDo not use excessive force when tightening the connector screws.
wInstall the equipments in a dry and protected place without risk of drip or water projections.
wAvoid to place it near to heating sources, in dusty locations or smoky enviroments.
wDo not block ventilation holes of the equipments so that air can circulate freely. O Remember, the installation and handling of these equipments must be performed by authorized
personnel and in the absence of electrical current. O Do always follow the enclosed information.
75
O To make a call the visitor should press the push button corresponding to the apartment he wishes to
contact. An acoustic tone will be heard confirming the call is in progress once the push button has been pressed . At this moment the call will be received at theand the door panel led will turn on monitor (telephone) in the dwelling. During the call the visitor can correct his call by pressing a push button corresponding to a different apartment, in which case the original call is cancelled.
O In systems with several accesses doors, the other(s) door panel(s) will be automatically disconnected:
If a visitor tries to call from other door panel an acoustic tone will be heard and the door panel led will be on .confirming the system is busy
O General door panel (EL501 mode): If the call is made from the general door panel, the inner door
panel of the building called and other possible general door panel will remain automatically disconnected, if another visitor tries to call from an inner busy door panel an acoustic tone will be heard confirming the systemis busy or fromanother general doorand the doorpanel led will be on panel, an acoustic tone will be confirming the system is busy andheard the general door panel led will blink for 3 seconds. The door panels of the others inner buildings will remain free to be used.
O General door panel(EL501 mode):In thecase that thecall ismade froman inner doorpanel, therest
of inner door panels will remain free to be used. From general door panels only will be able to make calls to the inner buildings whose door panels are not in use, if the visitor tries to make a call to a busy inner door panel, an acoustic tone will be heard confirming the system is busy and the general door panel will blink for 3 secondsled .
O
The call lasts for 45 seconds, during which time an image appears on the apartment's monitors for 2 seconds after thecall isreceived withoutthe visitorknowing, and the statusLED onthe mastermonitor will illuminate (green). If the call is not answered within 45 seconds, the master monitor's status LED will illuminate (red), LED onthe door panel will turn off and the channel will be free.
O To establish communication, lift the handset of the monitor (telephone), and the monitor's status LED
(green) and the door panel's LED will illuminate
.
O
The communication will last for one and a half minutes or until the handset is replaced. After the communication, the monitor's status LED will illuminate (red), the door panel's LED will turn off and the channel will be free.
O To open the door, press the door release push button during call or communication progresses: with
one press, thedoor releaseoperates during 3seconds. Duringthe lock releaseactivation an acoustic tone will be heard on the door panel confirming the lock release is activated and the led will also turn on for 3 seconds.
SYSTEM OPERATION
76
Uno system:
O Tekna Uno monitor T-540 Uno telephone are fully compatible with Tekna Plus monitor T-and and
540 Plus telephone. However, a Uno communications resistor must be setting with the SW1 configuration dip switch of the door panel, see 85 .( page )
O If the distance from the door panel to the farest monitor or telephone is longer than 200 meters, or
the building has more than 200 apartment units, a repeater must be installed.RDPlus/Uno SE
IMPORTANT NOTICEIMPORTANT NOTICE
76
DOOR PANEL DESCRIPTION
Sound module
EL63 Plus P/T2 EL64 Plus2
D
oor panel description.
Push buttons electronic module
EL610D
Short connection cable, It is supplied with EL610D module (16 cm length).
, for 5 single push-buttons or 10 double push buttons.
, on video systems with color camera. , on audio systems.
Connection cable RAP-610D (27 cm length).
General detail of parts, for assembly the door panel.
Aluminium modules
Electronic
modules
Frame modulesEmbedding boxes
Push buttons module
Main module
Door panel description.
For the connection of the push-buttons between the sound module and the push
buttons module EL610D and between push-buttons modules EL610D.
For the connection of the push-buttons between the sound module and the push
buttons module EL610D and between push-buttons modules EL610D.
This cable is necessary when the distance between modules to connecting is
greater due to the distribution of these modules in the door panel/s.
Bus Nexa connection cable e th(l ng 50 cm).
For the connection of the or modules with others BusEL632 Plus P/T EL642 Plus
Nexa modules (see page ).83
77
s
ound module description (EL632 Plus P/T and EL642 Plus).
Note: See installation diagrams for wiring.
MODULES DESCRIPTION
Micr .ophone
Speaker.
Front side.
Sound module push buttons (x2).
Installation terminals CN1.
Push buttons connector CN6.
Back side.
: ontact . Rel 3."C" c free for lock release ay : . Rel 3."N.O" contact free for lock release ay : Positiv , .e ground : .Digital communication : .Audio output communication : .Audio input communication : .Twisted pair video signal input : .Twisted pair video signal output : .Coaxial shield : .Video signal coaxial input : .Video signal coaxial output
Color camera .(only EL632 PLUS module )P/T
CV1 CV2 +, D Aout Ain Vi+,Vi­Vo+,Vo­Malla Vi+ Vo+
_
Monitor audio adjustment.
Leds (visual indications for people with impaired hearing).
Leds .illumination (only function with EL632 PLUS module)P/T
Bus Nexa c non ector CN8.
Configuration dip switch SW2.
Door panel audio adjustment.
Function connecto CN3.
Configuration dip switch SW1.
Push button number.
Door panel audio adjustment. Monitor audio adjustment.
78
P
78
P
ush buttons electronic module EL610D description.
Front side.
Push buttons module (x10).
Configuration dip switch (Push buttons call code).
Push button number.
Input/Output push buttons connector (x3).
Back side.
MODULES DESCRIPTION
90CS
CEA90C
99
143
40
Door panel
Model
An
Al
P
90C
CEV90C
99
250
56
90
CEV90
99 mm.
328 mm.
56 mm.
1650
1850
1450
79
DOOR PANEL INSTALLATION
E
mbedding box positioning.
The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions
will depend on the type of door panel.
The door panel has been designed to be placed under most of the environmental conditions.
However it's recommended to take additional cautions like rainproof covers. To obtain a good quality picture on video door entry systems, avoid direct incidence from light sources.
P
reparing the cables entry.
Break the bottom flange to pass the cables through. In case of door panels
with more than one embedding box, break the side flanges and attach the embedding boxes using UC junctions.
80
DOOR PANEL INSTALLATIONDOOR PANEL INSTALLATION
A
ssembly the electronic modules.
Insert the sound module in the top part of the module frame.
Align the tabs on the sound module in their respective housings of the module frame and later exercise a light pressure until correct placement.
Sound module EL632 Plus P/T EL642 Plus
Push buttons electronic
module EL610D
Frame
If there is push buttons module repeat the above process, locating under the sound module,
as shown in the drawing.
Frame
80
P
lace the embedding box.
Passthe wiringthrough thehole madein thebottom partof the
embedding box. Level and flush the embedding box. Once the embedding box is placed, remove the protective labels from the attaching door panel holes.
81
DOOR PANEL INSTALLATION
H
old the frame on the embedding box.
P
lug the push buttons with the short connection cable.
Between push buttons modules EL610D of the same embedding box,
insert the short connection cable of the low connector of the first push buttons module to the top connector of the second push buttons module, as shown in the drawing.
Insert the short connection cable that it is supplied with the product
EL610D, in the push buttons connector of the sound module and the other end of the connection cable in the connector placed in the top part of the push buttons EL610D module, as shown in the drawing.
Between push buttons modules EL610D ofdifferent embeddingt boxes,
insert the short connection cable in the low connector of the last module EL610D of the first embedding box and the other end of the connection cable in the middle connector of the last push buttons module EL610D placed in the low partof the second embeddingbox, as shown in the drawing.
Insert the hinge that it is supplied with the product in the embedding
box, as shown in the drawing.
To holdthe frame on the embedding box, insert the hinge in the
housings arranged for this purpose in the frame, as shown in the drawing.
The frame can now be folded horizontally facilitating the connection
and adjustments in the sound module and push buttons electronic module.
82
P
C
Use the connection cable RAP-610D, for the connection of the push buttons
The push buttons module EL610D must be configured, to assign a call code to
Depending on the setting selected, the push buttons are assigned to a specific
In case to combine these door panels with coded door panels or porter s'
(1)
*
( )
DOOR PANEL INSTALLATIONDOOR PANEL INSTALLATION
82
P
lug the push buttons with the connection cable RAP-610D.
C
onfiguration of the push-buttons code.
Push buttons module EL-610D
2
Dip1
1
4
6
8
3
5
7
71
Dip2
Dip3
Dip4
Dip5
Dip6
Dip7
Dip8
Push buttons code
Module configuration option
P1 P2 P3 P4 P5 P6 P7
1
21
41
61
11
31
51
2
22
42
62
12
32
52
72
3
23
43
63
13
33
53
73
4
24
44
64
14
34
54
74
5
25
45
65
15
35
55
75
6
26
46
66
16
36
56
76
7
27
47
67
17
37
57
77
8
28
48
68
18
38
58
78
9
29
49
69
19
39
59
79
10
30
50
70
20
40
60
80
P8 P9 P10
10
12
9
11
13
81
101
122
91
112
82
102
123
92
113
83
103
124
93
114
84
104
125
94
115
85
105
126
95
116
86
107
127
96
117
87
108
128
97
118
88
109
129
98
119
89
110
130
99
120
90
111
131
100
121
Dip switch
On
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
Off
Off
On
On
On
On
On
On
On
Off
Off
Off
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
On
Off
Off
On
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Off
Important: Select a different configuration option for each module EL610D.
P1- P10: Push button 1 to push button 10. Note:Sound module factory set the code " ., 106" 132"in P1 and " in P2
Use the connection cable RAP-610D, for the connection of the push buttons
between the sound module and the push buttons module EL610D and between push buttons modules EL610D, when the distance between modules to connecting is greater due to the composition of the door panels.
The push buttons module EL610D must be configured, to assign a call code to
the push buttons. Make this configuration with the dip switch placed in the back side of the module.
Depending on the setting selected, the push buttons are assigned to a specific
call code.
In case to combine these door panels with coded door panels or porter s'
exchange, it will be necessary to known the call code of each push button, as shown in the table below.
(1)
(1)
*
( )
*
( )
Factory default.
*
( )
83
The connector CN8 Bus Nexa is located at the upper left side of the back of
the sound module.
Insert the connection cable that it is supplied with the module in the CN8
connector of the sound module and the other end of the connection cable in the module with connector Bus Nexa.
The modules to connect with connector Bus Nexa are the next :
ðN3403/AL: Con ect m duln to the o e to add to the system with a graphic display module (coded
panel, see manual)TCode/CD Nexa .
ðN3301/AL: Con ectn to the module to add to the system with an access control module and
coded panel, (see manual)TCode/CD Nexa .
ðN3301A/AL: Co nectn to the module to add to the system with an alphabetic module, (see
TCode/CD Nexa manual).
ðEL4502/NFC: Co nect an NFC access seen to the module to add to the system with control (
manu l )a .TCode/C NexaA NFC
ðEL3002: Con ect (M xim 2 ).n to power the illumination module a um EL3002modules ðCD-NEXA/BT: Con ectn to the module to add to the system with a configuration RFC interface
(wireless device of 2,4 Ghz). Onlyfor and modulesN3301 N3403 .
D
escription CN8 Bus Nexa connector.
C
on .nection with EL3002 illumination modules
Insert Bus Nexathe connection cable that it is
supplied with the product in the CN8, connector of the sound module and the other end of the connection cable in any of the three connectors placed at the bottom of the EL3002 illumination module.
To connect to other illumination modules use
any of the two free connectors.
NOT :E Only the or sound moduleEL632 Plus P/T EL642 Plus must be connected to power
supply The EL3002 illumination module take the power through Bus Nexa connection cable. (once the Bus Nexa connection cable has been connected in the sound module).
DOOR PANEL INSTALLATION DOOR PANEL INSTALLATION
84
DOOR PANEL INSTALLATION
84
The door panel illumination leds, will turn on during call and
communication progresses. Allowing us to see from apartment´s monitor the person who has called. Only sound( EL632 Plus P/T module .)
D
escrip .tion illumination leds
Visual indications on the door panel for people with impaired hearing:
- While calling: The led will turn on during the call time process.
- Duringcommunication: The led willturn on during communicationprocess.
- Duringdoorrelease: The led willturnon duringdoorrelease.
- End of communication:The led willturn off.
- In systems with several accesses doors in the buildingandone access doorpanel isin comunication: The otheraccessesdoors panels would havethe led of busysystem turn on until end communication.
- While callingand the monitor is switchoff:The led willblink during3 seconds.
D
escrip .tion visual indications leds
85
D
escription of the SW1 configuration dip-switch of the sound module.
Placed to OFF if the sound module is configured as EL500 .operating mode Set to ON if the sound module is configured as EL501 operating mode
(general door panel).
Selects the d done from the (AP' 'oor opening time, external push button
terminal), see page 106. Placed to ON:door opening timedat 3 seconds. Set to OFF:door opening timed at 15 seconds.
Selects the type of cable to be used for the video signal. Placed to OFF:coaxial cable RG-59 o RG-11. Set to ON:twisted pair.
Placed to OFF if the door panel has telecamera. In case of door panels without telecamera (EL642 Plus sound module) set to ON.
Plus system, loads the installation with a communications resistor . For aPlus
proper system operation, placed to ON only in the closestdoor panel to the
backbone installation or in the general door panel (if exists), set the rest to
OFF.
Set to ON so that the volume tone emitted by the door panel: (call reception, busy system and lockrelease) are or placed to OFF if aHIGH,
LOWvolume tone is desired.
Uno System, loadsthe installation with a communications resistor . For aUno
proper system operation, set to ON only in the closest door panel to the
backbone installation, placed the rest to OFF. With digital repeater RD Plus/Uno:
In the backbone installation or after the inner door panel in systems with
general door panels, placed the door panel/s to OFF.
6
6
7
6
7
6
Placed to ON, the calls made on the door panel will be transferred to the
porter's exchange(if exists).Set to OFF, the call is received in theapartment.
In general door panels systems with porter , this function is only's exchange
applicable to the general door panels not to the inner door panel/s.
Factory default
The SW1 configuration dip-switch is locatedat theupper right
side of the back of the module.
Not :e 9 10The dip-switches and without function.
DOOR PANEL INSTALLATION
6
7
8
6
7
8
86
D
86
DOOR PANEL INSTALLATION
B
inary coding of the SW2 configuration dip switch of the sound module.
The switches set to OFF have null value. The values of the switches
set to ON are shown in the enclosed chart. The backbone code will be calculated as the sum result of the switches values set to ON.
Example: 64+0+16+0+4+2+1=87
Switch number: ON value:
46453261678849210
1
D
escription of the SW2 configuration dip-switch of the sound module.
Allows to activate the autoswitch-on function (audio-video communication
without previous call) at thedoor panel that hasthis switch to ONposition. In systems with several door panels activate this function only in one of them; in systems with general door panel this function can be activated in one door panel of each inner backbone (building).
Set to ON for monitor or telephones programming. Once the programming
progress is finished return the switch to OFF position. The programming process is described on corresponding monitor / telephone manual, (see page 74 for manual web link).
In general door panel (EL501 mode), set to ON for general door panel
push buttons programming or backbone (building) monitor/telephones. The programming process is described on pages 87 to 89. Once the programming progress is finished return the switch to OFF position.
Set to OFF in case of a master door panel. Each system must have only one
master door panel; the rest must be slaves (ON).
In systems with general door panel, set as master one door panel of each
inner backbone (building) and the general door panel as slave. Of this way, theuser will be able to distinguish since door panel are calling him.
Switches number 4 to 10 set the building code. In backbones with several
door panels, set the same code in all the panels; in systems with general door panel, set different codes for each inner backbone (building). Set a code between 1 and 120 for inner backbones (up to 127 with coded panel) and a code 0 ( ) for general door panel/s. To set theFactory default code use binary coding as shown on the next paragraph.
Factory default
The SW2 configuration dip-switch is located at the upper left
side of the back of the module.
87
Configure the sound ofthe general door panel in EL501 mode, (see page 85).module
Locate the SW2 configuration dip switch of the general door
panel to program, placed at the upper left side (back) of the sound module.Withtheswitches 1 and 3 to OFF, set the switch 2 to ON: to show that the system is ready for programming, thegeneraldoorpanelwillreproducea tone.
Pick up the monitor/telephone handset of the apartment to
program and press the door release push button until to establish communication of audio with the general door panel.
Press the general door panel push button that will call to this
monitor or telephone. At this moment the general door panel will reproduce a tone. To finish the push button programmation, replace the monitor/telephone handset; to show that the push button has been succesfully programmed, the general door panel will reproduce a tone.
Make a call to check that the push button has been succesfully programmed.
Repeat these steps to program the rest of push buttons.
Once the programming has been finished, set to OFF the programming
switch. If you don't, the general door panel will reproduce a tone to advise that the system is still into programming mode.
G
eneral door panel (programming modes).
This programming modeallows toassign a monitor/ telephone(programmed) to thepush buttonof
the general door panel that it wishes to call.
Before the monitors/telephones of the inner door panel/smust be programmed, see the corresponding
monitor/ telephone manual, (see page 74 for manualweb link).
IMPORTANT: Before programming the general door panel push buttons, switch off the porter's
exchange (if exists).
Programming the push button (by call of monitor/telephone):
The general door panel permits the following programming modes:
O Programming the push button (by call of monitor). O Programming the push button (with a backbone code). O Programming the push button (with a monitor/telephone code). O Programming the monitor/telephone.
P
rogramming the push buttons of the general door panel.
GENERAL DOOR PANEL INSTALLATION
88
T-540 Plus SETekna Plus SE
88
GENERAL DOOR PANEL INSTALLATION
Define a backbone code to program with dip switches Sw2-4 to Sw2-
10. Set a code between 1 and 120. To set the code use binary coding,(seepage86).
Pressthe general doorpanel pushbutton thatis wishedhas this
backbone code. At this moment the general door panel will reproduce a tone, confirming that the push buttonhas been succesfully programmed.
Repeat these steps to program the rest of push buttons. Once the programming has been finished,
set to OFF the programming switch. If you don't, the general door panel will reproduce a tone to advise that the system is still into programming mode.
Programming the push button (with a monitor/telephone code):
This programming mode allows to assign a monitor/telephone code to push button of the general
door panel.
Locate the SW2 configuration dip switch of the general door
panel to program, placed at the upper left side (back) of the sound module. With the switches 1 and 3 to ON, set the switch 2 to ON: to show that the system is ready for programming, the generaldoor panel will reproduce a tone.
Pressthe general doorpanel pushbutton thatis wishedhas this
monitor/telephone code. At this moment the general door panel will reproducea tone,confirming that thepush button has been succesfully programmed.
Repeat these steps to program the rest of push buttons. Once the programming has been finished,
set to OFF the programming switch. If you don't, the general door panel will reproduce a tone to advise that the system is still into programming mode.
Define a monitor/telephone code to program with dip switches Sw2-4
to Sw2-10. Set a code between 1 and 120. To set the code use binary coding,(see page 86).
Programming the push button ( ):with a backbone code
This programmingmode allows to assigna backbone code to push button of the general doorpanel.
Locate the SW2 configuration dip switch of the general door
panel to program, placed at the upper left side (back) of the soundmodule. With the switch 1 to ON and 3 to OFF, set the switch 2 to ON: to show that the system is ready for programming, the generaldoor panel will reproduce a tone.
89
GENERAL DOOR PANEL INSTALLATION
DOOR PANEL INSTALLATION
This programming modeallows toassign toa monitor/ telephonea pushbutton ofthe generaldoor
panel that it wishes to call.
Before the push button of the general door panel must be programmed with backbone and
monitor/telephone code, (see page 88).
Programming the monitor/telephone:
Locate the SW2 configuration dip switch of the general door
panel to program, placed at the upper left side (back) of the soundmodule. With the switch 1 to OFF and 3 to ON, set the switch 2 to ON: to show that the system is ready for programming, the generaldoor panel will reproduce a tone.
Thenprogramthe monitor/telephone,as it is describedon correspondingmonitor / telephone manual,
(seepage 74 for manualweb link).
Bear in mind the configuration dip switch (as it is described in the previous step).
P
rogramming the monitors and telephones from a general door panel.
D
escription of the function connector CN3.
The function connectorCn3 islocated at theupper leftside of theback of
the sound module.
Plug the cable that is supplied with the module, to realize the following
functions:
10
1
9
2
837
4
6
5
Top view CN3
Description connector CN3
ð"AP" function: It activates the relay of the lock release "CV1" and "Cv2", configurable activation
time of 3 or 15 seconds via dip switch SW1-2(page 85), see connections (page 106).
ð"ICO"function:Forthe busychannel indication, it willbe realized with terminals"ICO" and "+12". ð"Handicap" function: Synthese vocale from FDI (France). The connector includes all wires for
connection (see page 106).
1 Grey (-) Ground. 2 Brown (+12) 12Vdc for activation the lock release. 3 White (ICO) Busy channel indicator. 4 Yellow (AP) External push button to activate the lock release. 5 Violet (+H) For activation of an external illumination. 6 Blue (OP) Handicap. 7 Orange (SC) Handicap. 8 Green (ALM) Handicap. 9 Red (PDB) Handicap. 10 Black (-) Ground.
90
90
DOOR PANEL INSTALLATION
F
inal adjustments.
P
lace the nameplate labels.
Open the label holder.
Place the label and
close.
Once finished the works of wiring, configuration and
final adjustments, fix the frame in the embedding box with the supplied screws.
C
lose the frame.
If after starting the system it's considered that the audio
volume isn't correct, proceed with the necessary adjustments as shown .
in the drawing
The telecamera has a pan and tilt mechanism built in to
adjust the telecamera position.
91
DOOR PANEL INSTALLATION
C
lose the door panel.
D
oor panel assembly.
In assemblies of a single door panel, it is ready from factory
to be mounted.
IMPORTANT:
To makethese adjustments of joining several door panels, see the
document that is supplied with the door panel and follow the steps that are described in the section" Mechanical assembly for double door panel" and once finished the adjustments stick the adhesive gasket (that is supplied with the push buttons module) in the rod of joining modules.
If the door panel to installing is of more than onemodule it will be
necessary make some adjustments to join a door panel with other one.
Fixthe door panel by using the supplied screws.
Finish the door panel assembly by placing the closing
heads, put thehead onone side andthen make aslight pressure on the other end, to its correct placement.
92
92
LOCK RELEASE INSTALLATION
I
nstalling the FA-PLUS and FA-PLUS/C power supplies.
DIN 46277
3,5 x 25
DIN-7971
3,5 x 25
DIN-7971
POWER SUPPLY INSTALLATION
L
ock release installation.
Replace the protection cover once the input terminals have been wired.
It's recommended to protect the power supply by using a
thermo-magnetic circuit breaker. Use a ground connection with FA-Plus power supply.
To install the power supply directly on the wall, drill two holes of
Ø6mm. and insert the wallplugs. Fix the transformer with the
specified screws.
The power supply can be installed on a DIN 46277
guide simply pressing it.
To disassemble the power supply from the DIN guide,
use a plain screwdriver to lever the flange as shown on the picture.
The FA-Plus/C model uses 6 units over DIN guide and
10 units the FA-Plusmodel.
IMPORTANT: the maximum number of units that can be connected to a FA-Plus/C power supply is
10, and 50 units in case of a FA-Plus model. Link power supplies to connect more units than the specified as it's shown on page 105.
If the lock release will be installed in a metal door, use a Ø3,5mm.
drill and tap the hole Ø3mm. drill. In case of wood door,use a .
Install the power supply in a dry and protected place without risk of drip or water projections. To avoid an electrical shock, neither remove the primary protection cover nor handle the connected
wire in the terminals.
The installation and handling of these equipments must be performed by authorised personnel and
without the power connected.
To avoid damage, the power supply has to be firmly fixed.
IMPORTANT:
- The lock relese must beof (Golmar) d.c or a.c12V . ( 05 93See page 1 (a.c lock release) and pages to 1 (d.c lock release04 ).
- A varistor is supplied with the sound module. In case to connect an a.c. lock release, place the varistor on the lock releaseterminals directly to ensure a proper system operation.
M 4 x 8
3,5 x 25
DIN-7972
DIN-963
93
FA-Plus/C o FA-Plus
SEC
PRI
~~
+ +
--
A
A
_
_
+
+
D
D
Malla
Malla
V
in
V
in
V
out
V
out
CN4
CN4
A
_
+
D
Malla
V
in
V
out
CN4
A
_
+
D
Malla
V
in
V
out
CN4
E
E
D1
D1
D2
D2
+
+
D4L-PLUS
D4L-PLUS
JP1
JP1
S
S
M
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
10
1
9
2
837
4
6
5
CN3
Main
Place this power supply as closest as possible to the first distributor.
Take off JP1 jumper of all the distributors except in the last one.
INSTALLATION DIAGRAMS
Access door panel
M =Master.
S =Slave.
Lock release
Vd.c.
SW1
SW2
94
v
94
FA-Plus/C
SEC
PRI
230110 0
--
+ + D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
10
1
9
2
837
4
6
5
CN3
Main
ONE OR SEVERAL ACCESSES DOORS
v
ideo installation with coaxial cable.
1,00mm² 2,50mm²
0,25mm² 0,25mm²
RG-59 RG-59
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in out
V , V , V , V
in+ out+ in out
+, , CV1, CV2
C
oaxial cable characteristics RG-59 B/U MIL C-17.
Core max. electrical resistence to 20ºC
Copper core Copper shield
ELECTRICAL CHARACTERISTICS
Nominal capacitance
Characteristic impedance
VALUES
*
Velocity of Propogation
Access door panel
* *
The installation diagram shows the connection of a video system with one or several door panels
for the same building. If the system has one access door panel only, overridethe wiring to the second door panel. If the system has more than one access door panel, wire the second panel as shown on the
diagram. In case of more than two door panels, wire them as the second is connected.
Lock release
Vd.c.
75 3
+
-
<67pf/m
<158 /Km <10 /Km
_
_ _
_
>66,6 %
SW1
SW2
S
95
INSTALLATION DIAGRAMS
FA-Plus/C o FA-Plus
SEC
PRI
~~
+ +
--
JP1
AAD
D
CT
+
+
V
pi
V
d1
M
pi
M
d1
_
_
A D
CT
+
V
d6
M
d6
_
A D+
V
po
M
po
_
D6L-Plus/2H
VpM
p
A D
_
+
EL562 JP1
VpM
p
A D
_
+
EL562 JP1
JP1
AAD
D
CT
+
+
V
pi
V
d1
M
pi
M
d1
_
_
A D
CT
+
V
d6
M
d6
_
A D+
V
po
M
po
_
D6L-Plus/2H
VpM
p
A D
_
+
EL562 JP1
VpM
p
A D
_
+
EL562 JP1
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
10
1
9
2
837
4
6
5
CN3
* Place this power supply
as closest as possible to the first distributor.
Access door panel
M =Master.
S =Slave.
Lock release
Vd.c.
M
SW1
SW2
96
Main Main
* Take off JP1 jumper
of all the distributors except in the last one.
96
ONE OR SEVERAL ACCESSES DOORS
FA-Plus/C
SEC
PRI
230110 0
--
+ + D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
10
1
9
2
837
4
6
5
CN3
1,00mm² 2,50mm²
0,25mm² 0,25mm²
CAT-5 CAT-5
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in out
V , V , V , M
in+,- out+,- p,d p,d
+, , CV1, CV2
v
ideo installation without coaxial cable.
Lock release
Vd.c.
Access door panel
The installation diagram shows the connection of a video system with one or several door panels for
the same building. If the system has one access door panel only, overridethe wiring to the second door panel. If the systemhas morethan one accessdoor panel, wirethe secondpanel as shownon the diagram.
In case of more than two door panels, wire them as the second is connected.
IMPORTANT: For this type of installation, the door panels must have configured the switch nº.3 of
the SW1 configuration dip-switch to ON (page 85)in each and the monitors must
have an EL562 plugged in each (see page 74 for manual web link or QR in box
monitor).
SW1
SW2
S
97
INSTALLATION DIAGRAMS
FA-Plus/C o FA-Plus
SEC
PRI
~~
+ +
--
A
A
+
+
_
_
D
D
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
10
1
9
2
837
4
6
5
CN3
Main
*Place this power supply
as closest as possible to the first telephone.
Access door panel
M =Master.
S =Slave.
Lock release
Vd.c.
A
+
_
D
A
+
_
D
M
SW1
SW2
98
T-540 Plus SE T-540 Plus SE
T-540 Plus SE T-540 Plus SE
98
ONE OR SEVERAL ACCESSES DOORS
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
10
1
9
2
837
4
6
5
CN3
FA-Plus/C
SEC
PRI
230--110 0
+ +
Main
A
udio installation.
1,00mm² 2,50mm²
0,25mm² 0,25mm²
Terminal
SECTIONS CHART
50m.
Distance
150m.
A , A , A, D
in out
+, , CV1, CV2
Lock release
Vd.c.
Access door panel
The installation diagram shows the connection of an audio system with one or several door panels
for the same building. If the system has one access door panel only, overridethe wiring to the second door panel. If the systemhas morethan one accessdoor panel,wire the secondpanel asshown on thediagram.
In case of more than two door panels, wire them as the second is connected.
SW1
SW2
S
99
To monitors
Main
Inner door panel
Main
General door panel
EL500 mode
BACKBONE 1
INSTALLATION DIAGRAMS
M =Master.
S =Slave.
BACKBONE 0
E S +
S1
D4L-PLUS
JP1
FA-Plus o FA-Plus/C
SEC
PRI
~~
+ +
--
FA-Plus/C
SEC
PRI
230--110 0
+ +
M
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
Lock release
Vd.c.
Lock release
Vd.c.
10
1
9
2
837
4
6
5
CN3
10
1
9
2
837
4
6
5
CN3
S
SW2
SW1
SW2
SW1
EL501 mode
100
To monitors
100
To monitors
Continues
in the following page
Main
EL501 mode
Main
General door panel
EL500 mode
BACKBONE 2
Inner door panel
GENERAL DOOR PANEL
BACKBONE 0
E S +
S1
D4L-PLUS
JP1
SEC
PRI
~~
+ +
--
FA-Plus o FA-Plus/C
FA-Plus/C
SEC
PRI
230--110 0
+ +
M
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
Lock release
Vd.c.
Lock release
Vd.c.
10
1
9
2
837
4
6
5
CN3
10
1
9
2
837
4
6
5
CN3
SW1
SW2
S
SW1
SW2
10
1
9
2
837
4
6
5
CN3
101
INSTALLATION DIAGRAMS
E S
+
S1
S2
D4L-PLUS
JP1
FA-Plus o FA-Plus/C
SEC
PRI
~~
+ +
--
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
Coming
from previous page
v
ideo installation with general door panel
to large residential complexes.
Malla
Vin- Vin+ Vout-Vout+
Malla
Vin- Vin+ Vout-Vout+
IMPORTANT NOTES:
To install and configure properly,do always follow the enclosed information. The installation diagramshows the connectionof a video system with twogeneral door panelsand up to
120 inner door panels (backbones/buildings). In case of more than two door panels, wire them as the second is conected. In video systemsuse a D4L-Plus distributor before eachinner building except inthe last one. Take offJP1
jumper of all the distributors except in the last one. In video systems with use the D6L-Plus/2H distributor instead of D4L-Plus distributor. Takeofftwisted pair
JP1 jumper of all the distributors except in the last one. Add a negative in the inner building
installation riser,(see page 95). Below shows the connection of the twisted
pair instead of coaxial cable.
To monitors
Main
Inner door panel
EL500 mode
BACKBONE 119
M
Lock release
Vd.c.
SW2
SW1
102
To monitors
102
GENERAL DOOR PANEL
SEC
PRI
~~
+ +
--
FA-Plus o FA-Plus/C
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
v
ideo installation with general door panel
to large residential complexes.
For greater distances contact our technical support department.
1,50mm² 2,50mm²
0,25mm² 0,25mm²
CAT-5
RG-59
Terminal
SECTIONS CHART
100m.
Distance
300m.
A , A , A, D
in out
V , V
in+ out+
V , V , V , V
in+ in out+ out- -
+, , CV1, CV2
RG-59
CAT-5
Coaxial
Sw1-3 Off
Twisted pair
Sw1-3 On
*
Coaxial cable characteristics RG-59 B/U MIL C-17, (see page 94).
* *
To monitors
Main
EL500 mode
BACKBONE 120
Inner door panel
M
Lock release
Vd.c.
10
1
9
2
837
4
6
5
CN3
SW1
SW2
103
INSTALLATION DIAGRAMS
FA-Plus o FA-Plus/C
SEC
PRI
~~
+ +
--
FA-Plus/C
SEC
PRI
230--110 0
+ +
S
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
To telephones
Main
Main
General door panel
Inner door panelBACKBONE 1
EL501 mode
EL500 mode
BACKBONE 0
M =Master.
S =Slave.
10
1
9
2
837
4
6
5
CN3
10
1
9
2
837
4
6
5
CN3
M
Lock release
Vd.c.
Lock release
Vd.c.
SW2
SW1
SW1
SW2
104
To telephones
104
GENERAL DOOR PANEL
SEC
PRI
~~
+ +
--
FA-Plus o FA-Plus/C
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
To telephones
A
udio installation with general door panel
to large residential complexes.
1,50mm² 2,50mm²
0,25mm² 0,25mm²
Terminal
SECTIONS CHART
100m.
Distance
300m.
A , A , A, D
in out
For greater distances contact our technical support department.
+, , CV1, CV2
Main
IMPORTANT NOTES:
To install and configure properly,do always follow the enclosed information. The installation diagram shows the connection of an audio system with one general door panel
and up to 120 inner door panels (backbones/buildings).
In case of more than one general door panel, wire them as it shows in the video installation
diagram, (see page 99).
BACKBONE 120
Inner door panel
EL500 mode
10
1
9
2
837
4
6
5
CN3
M
Lock release
Vd.c.
SW1
SW2
105
INSTALLATION DIAGRAMS
C
onnexion of an a.c. lock release.
L
ink of several power supplies units.
1st FA-Plus 2nd FA-Plus/C or FA-Plus
SEC
PRI
~~
Main
+ +
--
SEC
PRI
~~
Main
+ +
--
If an alternating current lock release has been installed, use a TF-104 transformer and connect it to
the lock release as it is shown on the diagram.
If the quantity of monitors or telephones to be connected is bigger than the supported from one
power supply (see page 92), use additional power supplies to match the required quantity. The first power supply should be connected to the door panel and to the first group of monitors or telephones; connect the next groups to the positive terminal of its corresponding power supply.
To wire several power supplies link their ground terminals.
NEVER link positive terminals of different power supplies.
To the door panel & to the first
group of monitors/telephones.
To the second group of
monitors/telephones.
Main
CN1
+
- -
+CV1CV2
SEC
PRI
230110 0
--
+ +
EL632 PLUS P/T
EL642 PLUS
FA-PLUS/C
Main
TF-104
SEC
PRI
~ ~ ~ ~
Lock release
Va.c.
Important: Place the varistor supplied with the sound module on the lock release terminals
directly to ensure a proper system operation.
*
*
106
E
xternal lock release activation.
The lock release can be activated at any moment by using an
external push button, thatmust be connected between 'AP'and ' ' terminals of the connector Cn3 from door panel (see page 89).
Door opening timed at 3 or 15 seconds, with the help of the dip
switch SW1-2 (see page 85).
This function will allows toexit fromthe buildingbeing notnecessary
the use of a key.
Door panel
Lock release
Vd.c.
Main
To monitors
Main
C
onnection to the synthese vocale module of FDI (for France).
Lock release
Vd.c.
106
OPTIONAL CONNECTIONS
CN1
-
CV1CV2
10
1
9
2
837
4
6
5
CN3
AP
FA-Plus/C FA-Plusor
SEC
PRI
~~
+ +
--
M
D
Malla
Vin-AinAout Vin+ Vout-Vout+
CN1
+-+CV1CV2
-
10
1
9
2
837
4
6
5
CN3
PRI
~~
~
~
SEC
TF-104
OP
SC
ALM
PDB
Red
Yellow
Green
JA
SC
12 -
OP
R
CA
12 +
ALM
PDN
PDB
MAS
PDG
VE
RO
GND
J1
J2
J6
J7
3 2 1
3 2
1
1 2 3
1 2 3
HCP
SYNTHESE VOCALE
SW2
SW1
TROUBLESHOOTING HINTS
An easy way to check that the system is working properly is to disconnect the wiring from the door panel
and to check the monitor directly connected to the sound module.
No shortcircuit will damagethe connected units, withthe exception of a shortcircuit between CTO and ' '–
monitor or distributor terminals.
O Nothing operates.
w Check the output power supply voltage between ' ' and '+' terminals: it should have 17,5 to
18,5Vd.c. If not, disconnect the power supply from the installation and measure again. If it's correct now, it means there is a short circuit in the installation: disconnect the power supply from mains and check the installation.
w Check that 'D' terminal is not shortcircuited with ' 'or '+' terminals. w Check that 'D' terminal hasn't been changed by 'A' terminal somewhere in the installation.
O Inappropriate audio level.
w Adjust the level volumes as shown on page 90. In case of feedback, reduce the audio levels until
feedback fade out. If feedback don't dissapears refer to the following hint.
O Continuous audio feedback.
w Check that 'A' terminal is not shortcircuited with other terminals.
O Door open function no operates.
w Remember that this function is only available during call and communication progresses. w The CV1 and CV2 terminals for door opening are voltage free outputs. The cable requires a
connection depending on whether 12Vdc or 12Vac is needed.(page to ) (page 10593 104 )
w Make a short circuit between the 'CV1' and 'CV2' terminals on the ; there shouldsound module
be12V (d.c. ora.c. depending on thetype doorrelease installed) between theterminals onthe door release. If so, check the lock release and its wiring.
O The system cannot be programmed.
w Check that the switch number 2 of the SW2 configuration dip switch is set to ON (see page 86)
and that the programming steps are correctly followed.
w Check that 'D' terminal is not shortcircuited with other terminals.
O Some units don't receive calls.
w Remember that each apartment musthave amaster unitonly. Check that the units are switchedon
and correctly programmed.
O There are no video image.
w Check the number 4 of the dip switch SW1 of the module 632 Plus P/T is in OFF (see page 85). w Check there is supply in the distributors, the voltage between '+' and '-' terminals should have 15
to 18 Vd.c.
O Push buttons don't work.
w Check that pressing the push button the door panel reproduce an acoustic confirming tone, if
not check the wiring and configuration of the push buttons (pages 81 to 82).
w If confirmation of pulsation exists, check the monitors or telephones programming on
corresponding monitor / telephone manual, (see page 74 for manual web link).
107
108
108
NOTAS/NOTES
110
109
110
NOTAS/NOTESNOTAS/NOTES
CONFORMIDAD/COMPLIANCE/CONFORMITÉ
Este producto es conforme con las disposiciones de las Directivas Europeas aplicables respecto a la Seguridad eléctrica y la Compatibilidad2014/35/CEE Electromagnética .2014/30/CEE
This product meets the essentials requirements of applicable European Directives regarding Electrical Safety Electromagnetic Compatibility20 / 5/ECC,14 3 20 4/ 0/ECC1 3 .
NOTA: El funcionamiento de este equipo está sujeto a las siguientes
condiciones: (1) Este dispositivo no puede provocar interferencias dañinas, y (2) debe aceptar cualquier interferencia recibida, incluyendo las que pueden provocar un funcionamiento no deseado.
NOTE: Operation is subject to the following conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any received interference, including the ones that may cause undesired operation.
111
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
golmar@golmar.es
www.golmar.es
Sistemas de comunicación S.A.
GOLMAR S.A.
C/ Silici, 13
08940- Cornellá de Llobregat
SPAIN
Loading...