golmar Nexa Modular GB2 User Manual

USER MANUAL
Code 50122371 TCODE/CA GB2 EN REV.0 172
Nexa Modular GB2
2-Wire Audio and Video Door Entry
System
Coded Panel
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
INTRODUCTION
First and foremost we would like to thank you for purchasing this product.
Our commitment to achieving the satisfaction of customers like you is manifested through our ISO-9001 certification and the manufacture of products like the one you have just purchased.
Its advanced technology and strict quality control will ensure that customers and users enjoy the numerous features that this device offers. To get the most out of them and ensure proper operation from day one, we recommend that you read this instruction manual.
CONTENTS
2
SET-UP WARNINGS
- Do not overtighten the screws on the power supply connector.
- Always disconnect the power supply before installing or making modifications to the devices.
- The fitting and handling of these devices must be carried out by .authorised personnel
- The wiring must run at least .40cm away from any other wiring
- Before connecting the device to the mains, check the connections between the door panel, power supply unit,
distributors, camera interface, GSM interface, monitors, telephones and hands-free audio terminals.
- Use the Golmar cable (2x1mm ).RAP-2150
2
- Always follow the instructions contained in this manual.
Introduction................................................................................................................................................................ ..2. .
Contents....................................................................................................................................................................... 2.
Set-up warnings................................................................................................................................ 2................................
Safety precautions........................................................................................................................................... . 3............ .
Characteristics..............................................................................................................................................................3.
System operation.......................................................................................................................................... 3.................
Description of the door panel............................................................................................................................................
.............................................................................................................. .. 4.
Description of the Nexa Modular door panel
............................................................................................................5Description of the EL632/GB2Asoundmodule
................................................................................................................6.Description of the sound module DIP switch
.......................................................................................................................6.Description of theconfiguration jumper
............................................................................6.Description of thedoor panel lighting LEDs for “low light conditions”
.......................................................................................................6.Description of thevisual signals on the door panel
......................................................................... 7.Description of thevocal synthesis (audible signals on the door panel)
.......................................................................................................... 7 -8.Selecting the sound module operating mode
....................................................................................................9Description ofthe TFT EL3422/GB2screen module
............................................................... 10.Description of the N3401/GB2 and NX3401/GB2 proximity reader module
.......................................................................................................10.Description of the TK3401/GB2 proximitykey kit
...................................................... 11.Description of the N3301/GB2 and NX3301/GB2 keypad access control module
................................................................................ 12..Description of theEL3002H/GB2 auditory accessibility module
..........................................................................................................13.Description ofthe EL3002 illumination module
Installation of the door panel
.............................................................................................................................................
..........................................................................................................................................14.
Preparing the cable entry
.........................................................................................................................................14.Fitting theembedding box
.............................................................................................................................. 14.Mounting the electronic modules
................................................................................................................15Fastening theframe to the embedding box
...........................................................................15Connections betweenthe sound, TFT andaccess control modules
..............................................................................................................................................16.Closing the door panel
Installation of the power supply
....................................................................................................................................16.
Installation of the lock release......................................................................................................................................17
Operation of the door panel......................................................................................................................................... 17.
Programming of the door panel........................................................................................................................................
...................................................... 18.
Entering and exiting programming mode/Programming structure and sequence
............................................................................................................................................. 19-25.Programming fields
...................................................................................................................................26.Programming fields summary
.....................................................................................................................................27-29.Managing proximity keys
.................................................................................................................................30-34Managing the apartment list
Wiring diagrams
.....................................................................................................................................................35-39.
CHARACTERISTICS
- Audio and video door entry system with simplified wiring (non-polarised 2-wire bus).
- Up to 4 access panels (DP-GB2Adistributor required for more than one access panel) per installation.
- Up to23 monitors and apartmentswith a Vesta2 monitorper installation. (Mixed installation with telephonesmax. 23 elements).
- Up to18 monitorsand apartments with a Vesta7 monitorper installation. (Mixed installationwith telephones max. 18 elements).
- Up to 32 telephones and apartments with T562 telephoneper installation (audio door entry system installation 'audio only').
- Up to 32 Nhea hands-free audio terminals and apartments per installation (audio door entry system installation 'audio only').
- Up to4 monitors/telephones per apartment.
- Up to 4 monitors in parallel (installation without distributors) per installation.
- Up to 128 telephones (T562/TNhea)and apartments per installation(EL632/GB2Asetto mode 2 or 6 'audio only',seep 7)..
- Up to 1 telephone per apartment (EL632/GB2Aset to operating mode 2 or 6 'audio only', see page 7).
- Different operatingmodes configurable on the EL632/GB2Asound module.
- Call confirmation tone.
- Visual signals providing the door panel with auditory accessibility (indicating call process, communication, door open and
channel busy).
- Audible signals providing the door panel with visual accessibility (indicating call in progress, missed call, door open, call
finished and engaged).
- Door opening timeable between 1 and 99 seconds.
- 2 outputs for independently activated lock releases.
- Relay 1 output to activate the DC or AC lock releases actuated by relay.
- Relay 2 output to activate the DC or AC lock releases actuated by relay.
- Input for exterior door opening button (Relay 1 output).
- Input for exterior door opening button (Relay 2 output).
- Maximum distance between the power supply and the furthest door panel: 80m with a cross-section of 1mm .
2
- Maximum distance between the power supply and the last distributor: 80m with a cross-section of 1mm .
2
- Maximum distance between the power supply and last telephone (audio only installation without distributors): 80 m with a
cross-section of 1 mm .
2
- Maximum distance between the distributor and monitor/telephone (mixed installation): 40m with a cross-section of 1mm .
2
SAFETY PRECAUTIONS
- Always disconnect the power supply before installingor making modifications to the devices.
- The fitting and handling of these devices must be carried out by .authorised personnel
- The wiring must run at least 40 cm away from any other wiring.
- On the power supply unit:
wDo not overtighten the screws on the connector. wInstall the power supply unit in a dry protected location free from the risk of dripping or splashing water. wAvoid locations thatare humid, dusty or near heat sources. wEnsure that the air vents are free from obstruction so that air can circulate freely. wTo avoid damage, the power supply unit must be firmlysecured in place. wTo prevent electric shock, do not remove the cover or handle thewiring connected to the terminals.
3
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
SYSTEM OPERATION
-To make a call, the visitor must select the apartment list or enter the apartment code; an audible sound indicates that
the call is being made and LED will illuminate. If vocal synthesis is enabled, a'Call isin progress'message appears indicating that a call is being made. At this moment the apartment's monitor receives the call. To cancel the call, press the bell button or C.
- In systems with several access doors, the other door panel(s) will be automatically disconnected. If another visitor
tries to call, a number of telephone tones will be heard to indicate that the system is busy and LED will illuminate. If vocal synthesis is activated, the message 'System is busy,try later' will be indicated on the door panel.
- The call lasts for 40 seconds and, when received, the image appears on the master monitor without the visitor
knowing. To view the image on a slave monitor, this function needs to have been activated on the monitor. If the call is not answered within 40 seconds, LED will turn off and thechannel will be freed.
- To establish communication, press button on any monitor (or pick up the handset of any telephone) in the
apartment and LED on the door panel will illuminate. If the door panel has an EL3002H/GB2 module with icon displayed on the front, theLED of the EL3002H/GB2module will illuminate.Make sure thatthe hearing aidis 15-25 cm away from the door panel to ensure maximum audio quality during communication with the apartment.
- Communication will last for one and a half minutes or until button on the monitor is pressed again (or the handset of
the telephone is replaced). When communication has finished, LEDs and will turn off and the channel will be freed. If vocal synthesis is activated, a 'Communication is finished' message will indicate that the call is over.
- To open thedoor, press button during the call or communication processes: one press will activate the lockrelease
for five seconds and LED will also turn on for five seconds. If vocalsynthesis is enabled, a 'Door Opened!' message will be indicated on the door panel.
- For a description of the functioning and setup of the monitor/telephone, see the monitor's user manual.
DESCRIPTION OF THE DOOR PANEL
Sound modules
EL63 GB2A2/ EL642/GB2A
, 2-wire video door entry system with colour television camera.
Door panel component assembly drawing.
Aluminium panel
Electronic modules
Frame moduleEmbedding boxes
Description of the door panel.
Description of the Nexa modular door panel:
Grille module:
N1000/AL N1110/AL 1P. N2220/AL 2P.
Clip-on covers: 60xx
Module C. Keypad access:
N3301/GB2
Nexa module separator (x2)
Fixing screws for endpieces (x8)
Side profile (x2)
Side profile Door panel UNE rod
*
Fixing screws for embedding box (x2)
Door panel UNE rod: Enables 2 door panels to be joined.
, 2-wire audio door entry system.
5-wire connection cable.
For connecting the
EL632/GB2A module to the N3401/GB2 module.
EL3422/GB2
TFT screen module
Information module:
N3002/AL.
*
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
4
Module C. RFID access:
N3401/GB2
N3301/GB2 keypad
access control module
N3401/GB2 RFID
access control module
12-wire connection cable.
For connecting the
EL632/GB2A module to the N3422/GB2 module and the N3301/GB2 module.
3-wire connection cable.
For connecting the
EL632/GB2A module to the EL3002HGB2 module.
DESCRIPTION OF THE SOUND MODULE
Microphone.
Speaker.
Front.
Sound module buttons (x2).
Terminal strip connector (GB2 Bus).
Socket for connection with the N3301/GB2 access control mod.
Back.
: Positive, negative (12Vdc output for Golmar DC electric lock). : Contact 'C' for electric lock (Relay 1). : Contact 'NO' for electric lock (Relay 1). : Input for exterior door opening button (Relay 1). : Contact 'NO' for electric lock (Relay 2). : Contact 'C' for electric lock (Relay 2). : Input for exterior door opening button (Relay 2). : Input for exterior call button (button 1). : Input for exterior call button (button 2). : Connection BUS (non-polarised). : Connection BUS (non-polarised).
Button number.
Colour television camera.
+, C1 NA1 AP ,AP+ NA2 C2 AP+,AP P1 P2 BUS BUS
_
Connection terminals:
DIP switch.
Socket for connection with the N3401/GB2 RFID reader mod.
Communication status LEDs.
LEDs (activation in low light conditions).
Micro-SD card slot.
_
_
Do not use (internal use).
Description of the EL632/GB2A sound module:
Socket for connection with the EL3422/GB2 TFT module. Socket for connection with the EL3002H/GB2 module.
5
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Note: See wiring diagrams for connections (pp. 35-39).
Description of the sound module DIP switch:
1 2 3 4 5 6
ON
+
C1
_
1
The DIP switch islocated on the left side of the back of the module.
1 2
3 4 5 6
ON
Door panel address: DIP switches: 1 and 2 OFF (address 1), 1 ON and 2 OFF (address 2), 1 OFF and 2 ON (address 3), 1 and 2 ON (address 4).
1 2 4 5 6
3
ON
Leave in the OFF position for door panels with double button and set to ON for door panels with single button.
1 2 3 5 6
4
ON
Leave in the OFF position for use with door panels in houses and set to ON for use in apartment buildings.
1 2 3 4 6
5
ON
Leave in the ON position to set the door opening time using the conguration menu. Set to OFF to set the door opening time to 1 second.
1 2 3 4 5
6
ON
Set to ON to congure: (see pp. 7-8)
Sound module operating mode. Leave in the OFF position once conguration is complete.
Description of the configuration jumper:
1 2 3 4 5 6
ON
+
C1
_
1
Important: Do not change the factory default position of the configuration jumper.
Description of the door panel lighting LEDs for low light conditions:
The door panel lighting LEDs will turn on during a call if the door panel lighting at
that moment is low. This enables the user to view the person who has called from the apartment monitor.
*
( )
*
( )
Factory setting.
Description of the visual signals on the door panel:
Visual signals on the door panel, indicating:
- While calling: LED will illuminate during in call and in communication times.
- During communication: LED will illuminate during the communication process.
- During door release: LED will illuminate during door release.
- End of communication: LEDs and will turn o.
- Calling at one door panel while another door panel is communicating (if there is more than one door panel):
LED will illuminate for 3 seconds.
- While calling and the monitor is in 'Do not disturb' mode: LED will illuminate for 4 seconds.
- While calling (apartment with no monitor or telephone): LED will illuminate for 4 seconds.
*
( )
*
( )
Factory setting.
*
( )
*
( )
*
( )
*
( )
*
( )
6
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
DESCRIPTION OF THE SOUND MODULE
7
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Description of the vocal synthesis (audible signals on the door panel):
Audible signals on the door panel. If vocal synthesis is enabled on the sound module (see page 19 and 21 for conguration), the following voice
messages can be heard on the door panel:
- While calling: 'Call is in progress'.
- During door release: 'Door Opened!'.
- End of communication: 'Communication is nished'.
- Calling at one door panel while another door panel is communicating (if there is more than one door
panel): 'System is busy, try later'.
- While calling and the monitor is in 'Do not disturb' mode: 'Call is in progress'.
- While calling (apartment with no monitor or telephone): 'Resident Unavailable'.
P1
Selecting the sound module operating mode:
To change the operating mode of the sound module,follow these steps:
- Disconnectthe door panel's power supply.
- Set DIP 6 onthe sound module (see page 6) to OFF.
- Reconnect the door panel's power supply.
- Set DIP 6 toON.
- Press and hold down button P1 on the sound module for 6 seconds (until the conrmation
tones end).
- Then continue pressing to changethe operating modeindicated by the visualalert LEDs of thedoor panel 'carousel
mode' (see the following operating mode selection table). Once the required operating mode is selected, stop pressing button P1.
- Finally, set DIP 6 toOFF.Aconrmation tone will be heard and the visual alert LEDs of the door panel will turn o.
Mode
Function
mode
LED LED LED
LED
House 1
1
2
( )
1
( )
*
( )
*
Operating modes
ON OFF OFF
ON OFF OFF
OFF ON OFF
OFF
OFF
OFF
3
4
5
ON ON OFF
OFF OFF ON
ON OFF ON
OFF
OFF
OFF
6
7
8
OFF ON ON
ON ON ON
OFF OFF OFF
OFF
OFF
ON
Door panel
Buttons
Buttons
Buttons
Buttons
Coded
Coded
Coded
Coded
Instal a nl tio
Video panel
Video panel/ Audio panel
Audio panel
Audio panel
Video panel
(Inst. with risers)
Video panel
(Inst. with risers)
Video panel
(Gen. panel inst.)
Video panel
(Gen panel inst.).
Building
(Up to 32 monitors/telephones)
Building 'router'
(Up to 128 monitors/telephones)
Building 'gateway'
(Up to 128 monitors/telephones)
Building 'tel. only'
(Up to 128 telephones)
Building 'tel. only'
(Up to 128 telephones)
Building 'router'
(Up to 256 monitors/telephones)
Building 'gateway'
(Up to 256 monitors/telephones)
Building
(Up to 32 monitors/telephones)
Buttons
Video panel/ Audio panel
( )
2
( )
2
( )
2
( )
2
( )
*
Dip4
OFF
ON
ON
ON
ON
ON
ON
ON
ON
Continued overleaf
( )
*
Sound module congured with : house mode and operating mode 1.default setting
( )
1
House mode. See the manual enclosed with the corresponding GB2 house kit.
( )
2
Building mode 'router'/'gateway'. See the manual enclosed with the RD-GB2/A module.
DESCRIPTION OF THE SOUND MODULE
------ ------ ------ ------
Mode 9 to 12 (no function)
Building mode 'telephones only' (audio panel): Up to 128 telephones/apartments.
Set DIP 4 on the sound module to ON (see page ).6
Building mode 'router': Set DIP 4 on the sound module to ON (see page ).6
- Up to 23 monitors and apartments with a Vesta2 monitor per riser (RD-GB2/A module(s) required).
(Mixed installations with telephones up to 23 elements).
- Up to 18 monitors and apartments with a Vesta7 monitor per riser (RD-GB2/A module(s) required).
(Mixed installations with telephones up to 18 elements).
- Up to 32 telephones and apartments with T562/Nhea telephones per riser (RD-GB2/A module(s) required).
(Audio door entry system installation audio only).
Building mode 'gateway': Set DIP 4 on the sound module to ON (see page ).6
- Up to 23 monitors and apartments with a Vesta2 monitor per interior panel (RD-GB2/A module(s) required).
(Mixed installations with telephones up to 23 elements).
- Up to 18 monitors and apartments with a Vesta7 monitor per interior panel (RD-GB2/A module(s) required).
(Mixed installations with telephones up to 18 elements).
- Up to 32 telephones and apartments with T562/Nhea telephones per interior panel (RD-GB2/A module(s) required).
(Audio door entry system installation audio only).
8
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Selecting the sound module operating mode:
Continued from previous page
Building mode: Set DIP 4 on the sound module to ON (see page ).6
- Up to 23 monitors and apartments with a Vesta2 monitor per installation.
(Mixed installations with telephones up to 23 elements).
- Up to 18 monitors and apartments with a Vesta7 monitor per installation.
(Mixed installations with telephones up to 18 elements).
- Up to 32 telephones and apartments with T562/Nhea telephones per installation.
(Audio door entry system installation audio only).
DESCRIPTION OF THE SOUND MODULE
9
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
DESCRIPTION OF THE TFT SCREEN MODULE
Description of the EL3422/GB2 TFT screen module:
Front.
Back.
TFT screen.
Socket for connection with the EL632/GB2A.
Note: See its connections (page 15).
DESCRIPTION OF THE PROXIMITY ACCESS CONTROL MODULE
Description of proximity reader modules N3401/GB2 and NX3401/GB2:
Front.
Back.
Proximity key reader.
Socket for connection with the EL632/GB2A module.
Bell button.
Selection buttons.
10
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Description of the TK3401/GB2 proximity key kit:
MASTER
CARD
ADD
MASTER
CARD
DELETE
Management keys for adding/deleting residents keys using the N3401/GB2
module.
MASTER CARD ADD: Key for adding residents proximity keys. MASTER CARD DELETE: Key for deleting residents proximity keys.
X5
TAGKEY residents access keys (Code 20740427).
Note: To add/delete proximity keys, follow the instructions on pp. 27-29.
Note: See its connections (page 15).
DESCRIPTION OF THE KEYPAD ACCESS CONTROL MODULE
Description of the N3301/GB2 and NX3301/GB2 keypad access control module
Front.
Back.
Numeric keypad.
Bell button.
Cancel button.
Socket for connection with the EL632/GB2.
Terminal strip connector for 22 Vdc output.
: Positive, negative (22 Vdc output maximum 100 mA)+ -
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Connection terminals:
IMPORTANT:
N3301/GB2 and NX3301/GB2 modules are not compatible with the connections of EL610D button modules.
Note:
See the connections of the N3301/GB2 and NX3301/GB2 modules on page 15.
11
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
DESCRIPTION OF THE AUDITORY ACCESSIBILITY MODULE
Description of the EL3002H/GB2 auditory accessibility module:
Front.
Back.
Communication active LED.
Socket for connection with the EL632/GB2A.
Terminal strip connector for 12 Vac power supply.
Connection terminals:
: 12 Vac power input (Only required if EL610D modules exist)~ ~
Note: See its connections (page 15).
12
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
DESCRIPTION OF THE ILLUMINATION MODULE
Description of the EL3002 illumination module
Front.
Back.
LED illumination panel.
Terminal strip connector for 12 Vac power supply.
Connection terminals:
: 12 Vac power input? ?
Note: See its connections (page 15).
NEXA Bus connectors. (Do not connect to GB2 system)
13
INSTALLATION OF THE DOOR PANEL
Pass the cable through the hole made in the embedding box.
Embed the box and ensure that it is level and flush. Once the embedding box is positioned, remove the protective stickers from the door panel's fixing holes.
Insert the sound module into the top of the frame module.
Line up the clips on the sound module with the respective housings on the frame module and then press gently until correctly positioned.
EL632/GB2A
sound module
If TFT module exists, repeat the above process, positioning it below the sound module, as shown in the drawing.
Fitting the embedding box:
Mounting the electronic modules:
Break the flange to allow entry of cables through the bottom
part of the embedding box.
In the case of door panels with more than one embedding box, break through the side holes and join the embedding boxes using cable grommets.
Preparing the cable entry:
EL3422/GB2
TFT module
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
14
INSTALLATION OF THE DOOR PANEL
Fastening the frame to the embedding box:
Insert the spring hinge which attaches to the product in the
embedding box, as shown in the drawing.
To fasten the frame to the embedding box, insert the spring
hinge into the housings providedfor this purpose inthe frame, as shown in the drawing.
The frame can now be tilted horizontally to enable connection and setting of
the sound module, TFT moduleand access control modules.
Connect the sound module to the different modules as shown in the
following section.
Connections between the sound, TFT and access control modules:
Plug one end of the connection cable attached to the EL3422/GB2
product into the 12-pin socket located on the top right of the sound module and the other end into the socket located in the centre of the EL3422/GB2 module. Similarly,connect one end of the connectioncable attached to the N3401/GB2 product to the 5-pin socket located in the left centre of the sound module and the other end to the socket located on the bottom right of the N3401/GB2 module. And connect one end of the connection cable attached to the N3301/GB2 product to the 12-pin socket located on the bottom right of thesound module and the other end to the socket located on the bottom right of the N3301/GB2 module.
Once the wiring and configuration work is done, fix the frame to
the embedding box using the screws supplied. Then place the access control modules into the frame in order to connect the connection cables between the sound module, access control modules and TFT asshown in the next section.
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
NA2
+
AP-
C1
NA1
AP+C2AP+AP-
P1 P2
BUSBUS
Relé 2Relé 1
_
12Vdc
Socket for the
EL3002H/GB2 (page 39)
EL3422/GB2
N3401/GB2
N3301/GB2
EL632/GB2A
15
INSTALLATION OF THE DOOR PANEL
Closing the door panel:
Fix the door panel to the embedding box using the screws
supplied.
To complete the tting of the panel, attach the clip-on covers
by positioning one end and then applying slight pressure to the other end until they clip into place.
INSTALLATION OF THE POWER SUPPLY UNIT
Installing the FA-GB2/A power supply unit:
Replace the protective cover once the input terminals have been wired.
Please note that current regulations stipulate that the power
supply must be protectedby a circuit breaker.
Connectthe FA-GB2/Apower supply unit to the earth connection.
Mount the DIN rail to the wall with the plugs and screws
supplied. Then attach the power supply by applying slight pressure.
The power supply can be installed on a DIN 46277 rail.
.
To remove the power supply unit from the DIN rail, use a flat
screwdriverto lever it off, as shown in the drawing.
The FA-GB2/Amodel requires 8 elements on the rail.
IMPORTANT: the maximum number ofunits that canbe connected to an FA-GB2/Apower supply is 23 VESTA
2 or 18 VESTA7 monitors.
Installthe power supply unit in adry protectedlocation free from the risk of drippingor splashingwater. Topreventelectric shock, do not remove the protective cover of the primaryor handle the wiring. The fitting and handling of this device must be carried out by in the absence of electricalauthorised personnel
current.
Toavoid damage, the power supply unit must be firmlysecuredin place.
DIN rail.
DIN rail.
DIN rail.
DIN 46277
DIN rail latch release.
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
16
Installing the lock release:
INSTALLATION OF THE LOCK RELEASE
M 4 x 8
3,5 x 25
DIN-7972
DIN-963
IMPORTANT:
-
The lock release must be 12V DC orAC (Golmar). (See page 38 for a.c. lock release and page 35-37 for d.c. lock release).
- The sound module is supplied with two varistors. If connecting an AC lock release to one of the outputs, fit the
varistor supplied directly to the lock release terminals to ensure the device functions correctly.
If the lock release is to be fitted to a metal door, use a Ø3.5mm drill bit and
thread the hole made. For wooden doors, use a Ø3mm drill bit.
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
DOOR PANEL OPERATION
Description of door panel operation:
Door panel in standby mode.
With the door panel in standby mode, the following operations can be performed:
Activation of external buttons: Enables activation of the outputs of Relay 1 or Relay 2 by means of the exterior AP
buttons for Relay 1 and Relay 2.
By keypad:
Default administrator code:
1234.
Opening by means of the access code: Enables activation of the output (Relay 1 or Relay 2) associated with the
code. Press the bellbutton of the N3301/GB2 module,followed bythe access code, and confirmwith the bell button of the N3301/GB2 module.
'bell (N3301/GB2)' + 'access code' + 'bell (N3301/GB2)'.
Administrator code: Enables entry into the door panel's programming mode. Press the bell button of the N3301/GB2
module, followed by the administrator code, and confirm with the bell button of the N3301/GB2 module.
'bell (N3301/GB2)' + 'administrator code' + 'bell (N3301/GB2)'.
Calls to monitors and telephones: Enables calls to be made to monitors and/or telephones connected to the same
installation. Press the monitor or telephone code followed by the bell button.
'monitor/telephone code' + 'bell'.
Calls to monitors and telephones through the apartment list: Enables calls to be made to monitors and/or
telephones connected to the same installation. Search for the resident using the arrow keys and press bell to make the call.
'Search resident using arrows button' + 'bell'.
By proximity:
Opening by means of proximity key: Enables activation of the Relay 1 output associated with the proximity key. Hold
the RFID key near to the reader of the N3401/GB2 module.
Managing proximity keys: Enables the adding/deleting of proximity keys to be managed using the MASTER CARD
keys included in the TK3401/GB2 kit. Use MASTER CARD ADD to add cards or MASTER CARD DELETE to delete them. It is also possible toActivate/Deactivate the proximity reader and delete all residents keys.
17
PROGRAMMING THE DOOR PANEL
Programming mode entry and exit:
To enter programming mode, press the bell button (N3301/GB2), followed by the administrator code '1234', and finally
confirm by pressing the bell button (N3301/GB2) again.
'bell (N3301/GB2)' + 'administrator code' + 'bell (N3301/GB2)'.
To exit programming mode, press the Cbutton (cancel) once if it is in a programming field or twice if not. If no button is pressed within 10 seconds, it exits programming mode. Programmingmode entry and exit is confirmed by the emitting of a long and short tone.
1 3 4
Programming mode structure and sequence:
C
0
05
2
Programming of the keypad functions is performed by entering the field or function code, followed by the bell button
(N3301/GB2) and the field value.
Once in programming mode, the programming sequence is as follows:
Enter the code of the field to be programmed: this code is always 2 digits. To confirm, press the bell
button (N3301/GB2) and the keypad will emit a long and then short tone indicating that the field to be programmed is correct or three short tones if the indicated programming field does not exist.
Enter the value of the field being programmed. Once the value has been entered, press the bell button
(N3301/GB2) and the door panel will emit a long confirmation tone if the information entered is correct or three short tones if it is not correct.
Note: If no key is pressed within 10 seconds, it will be necessary to enter the programming code and
select the programming field again.
Enter the code of the following field or press the C button (cancel) to exit programming mode.
If wrong information is entered or an access or administrator code is repeated, the door panel will emit three short tones
to indicate that the information is incorrect. If the field code to be programmed was being entered, the programming code must be re-entered; if the field value was being entered, the field value being configured must be re-entered.
Field
Field value
C
or
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
2
3
0 1
C C C
03
1
Programming
mode entry
sequence
2
0 5
18
Programming fields:
01
Press the bell button (N3301/GB2) to confirm the selection of the field.
9
0
01
The module is pre-programmed with factory settings except for the activation codes, which are left empty for security
reasons. For system operation tailored to the needs of the user, check the values set in all of the fields. The fields do not need to beprogrammed in numerical order.
Field '01': Sets the administrator code.
Bell (N3301/GB2) + administrator code + bell (N3301/GB2).
Enter programming mode:
Step 2: Then press the field number:
Step 1: Press the bell button (N3301/GB2), followed by the administrator code, and confirm with the bell button on
the module (N3301/GB2).
Press '01' to select field '01'.
0 9
Steps: Field + bell (N3301/GB2) + administrator code + bell (N3301/GB2).
Then press the number of the next field to configure or press the C button (cancel)
to exit programming mode.
03 C
or
(Step 1)
(Step 3)
(Step 4)
(Step 5)
Define the new administrator code using the numeric buttons from 0 to 9. The maximum
length of the administrator code is 12 digits.
The factory setting is 1234
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
1 3 4
2
...
...
Continued overleaf
Press the bell button (N3301/GB2) to finish programming the field.
(Step 2)
19
Programming fields:
Continued from previous page
Field '03': Sets relay activation time.
Enables the setting of an activation time for Relay 1 and Relay 2 between 1 and 99 seconds.
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
03
01 99
Steps: Field + bell (N3301/GB2) + activation time + bell (N3301/GB2).
...
Press the bell button (N3301/GB2) to finish programming the field.
99
01
03
Press '03' to select field '03'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
04 C
or
(Step 1)
(Step 3)
(Step 4)
(Step 5)
Define the activation time for the relays using the numeric buttons from 0 to 9. The time
entered must have .two digits
The factory setting is 01 seconds
...
Field '04': Sets relay activation mode.
Enables the setting of an activation mode for Relay 1 and Relay 2 between 0 (normally open) or 1 (normally closed).
04
0 1
Steps: Field + bell (N3301/GB2) + activation mode + bell (N3301/GB2).
or
Press the bell button (N3301/GB2) to finish programming the field.
1
0
04
Press '04' to select field '04'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
06 C
or
(Step 1)
(Step 3)
(Step 4)
(Step 5)
Define the activation mode for the relays using the numeric buttons 0 or 1.
0: Normally open. 1: Normally closed.
The factory setting is 0
or
Continued overleaf
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
20
Programming fields:
Continued from previous page
Field '06': Resets the administrator code to the factory setting and clears all access codes.
Enables the resetting of the administrator code to factory setting 1234 and the clearing of all access codes.
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
06
1
Steps: Field + bell (N3301/GB2) + administrator code + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
4
06
Press '06' to select field '06'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
08 C
or
(Step 1)
(Step 3)
(Step 4)
(Step 5)
Press default administrator code 1234.
Field '08': Sets the vocal synthesis language.
Enables the setting of the language to be used for vocal synthesis messages by selecting between 0 and 5.
08
0 5
Steps: Field + bell (N3301/GB2) + language selection + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
5
0
08
Press '08' to select field '08'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
11 C
or
(Step 1)
(Step 3)
(Step 4)
(Step 5)
Define the vocal synthesis language using the numeric buttons between 0 and 5.
0:No messages. 1:English. 2: Spanish. 3: French. 4: Dutch. 5: Portuguese.
The factory setting is 0
2 3 4
321
...
...
Continued overleaf
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
21
Programming fields:
Continued from previous page
Field '11': Volume of the sound module speaker in communication.
Enables the setting of the speaker volume of the sound module in communication.
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
11
Steps: Field + bell (N3301/GB2) + sound module volume level + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
11
Press '11' to select field '11'
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
12 C
or
(Step 1)
(Step 3)
(Step 4)
(Step 5)
Set the sound module speaker volume for when communication is established with a
telephone or monitor using the numeric buttons from 0 to 9.
The factory setting is 5.
Field '12': Sets the vocal synthesis volume.
Enables the setting of the vocal synthesis volume by selecting between 0 and 9.
12
0 9
Steps: Field + bell (N3301/GB2) + vocal synthesis volume + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
12
Press '12' to select field '12'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
13 C
or
(Step 1)
(Step 4)
(Step 5)
...
0 9
...
9
0
...
9
0
(Step 3)
Define the vocal synthesisvolume using the numeric buttonsbetween 0and 9, where 0 is
the lowest volume and 9 is the highest.
The factory setting is 5.
...
Continued overleaf
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
22
Programming fields:
Continued from previous page
Field '13': maximum intensity level of the illumination LEDs for the camera.
Indicates the intensity level of the illumination LEDs for the camera.
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
13
Steps: Field + bell (N3301/GB2) + intensity + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
13
Press '13' to select field '13'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
18 C
or
(Step 1)
(Step 3)
(Step 4)
(Step 5)
Define the maximum intensity level of the illumination LEDs for the camera, using the
numeric buttons 0 to 5, where 0 is the lowest level and 5 is the highest.
The factory setting is 4.
Field '18': Sets the temporary access code for Relay 1.
Enables the assignment of a temporary access code to activate Relay 1.
18
0 9
Steps: Field + bell (N3301/GB2) + Relay 1 access code + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
18
Press '18' to select field '18'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
19 C
or
(Step 1)
(Step 4)
(Step 5)
...
0 5
...
5
0
...
9
0
(Step 3)
Define the new temporary access code for Relay 1, using the numeric buttons 0 to 9.The
maximum length of the access code is 12 digits.
No factory setting has been defined
...
Continued overleaf
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
23
Programming fields:
Continued from previous page
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Field '19': Sets the temporary access code for Relay 2.
Enables the assignment of a temporary access code to activate Relay 2.
19
0 9
Steps: Field + bell (N3301/GB2) + Relay 2 access code + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
19
Press '19' to select field '19'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
20 C
or
(Step 1)
(Step 4)
(Step 5)
...
9
0
(Step 3)
Define the new temporary access code for Relay 2, using the numeric buttons 0 to 9.The
maximum length of the access code is 12 digits.
No factory setting has been defined
...
Field '20-59': Sets the access code for Relay 1.
Enables the storage of an access code to activate Relay 1. Up to 40 codes can be assigned for this relay.
59
0 9
Steps: Field + bell (N3301/GB2) + Relay 1 access code + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
59
Press '20-59' to select field '20-59'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
60 C
or
(Step 1)
(Step 4)
(Step 5)
...
9
0
(Step 3)
Define the new access code for Relay 1, using the numeric buttons 0 to 9. The maximum
length of the access code is 12 digits.
No factory setting has been defined
...
20
...
20
...
Continued overleaf
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
24
Programming fields:
Continued from previous page
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Field '60-99': Sets the access code for Relay 2.
Enables the storage of an access code to activate Relay 2. Up to 40 codes can be assigned for this relay.
99
0 9
Steps: Field + bell (N3301/GB2) + Relay 2 access code + bell (N3301/GB2).
Press the bell button (N3301/GB2) to finish programming the field.
99
Press '60-99' to select field '60-99'.
Then press the number of the next field to configure or press the C button (cancel) to
exit programming mode.
61 C
or
(Step 1)
(Step 4)
(Step 5)
...
9
0
(Step 3)
Define the new access code for Relay 2, using the numeric buttons 0 to 9. The maximum
length of the access code is 12 digits.
No factory setting has been defined
...
60
...
60
...
Press the bell button (N3301/GB2) to confirm the selection of the field.
(Step 2)
25
Congure administrator code
01
0 ~ 9 1234
Congure relay
activation time
03
01 ~ 99 01
Congure relay
activation mode
04
0:
Normally open
1: Normally closed
0: Normally open
Reset administrator code
and access codes
06
Sequence (1,2,3,4)
-
Congure vocal
synthesis language
08
0 ~ 5 0
Congure door panel in
communication speaker volume
11
0 ~ 9
5
Congure vocal synthesis
and beep volume
12
0 ~ 9
5
Congure camera illumination
LED intensity level
13
0 ~ 5
4
Programme temporary
access code/Relay1
18
0 ~ 9
-
Programme temporary
access code/Relay2
19
0 ~ 9
-
Programme access
code/Relay1
20-59
0 ~ 9
-
Programme access
code/Relay2
60-99
0 ~ 9
-
DESCRIPTION OF THE
PROGRAMMING FIELD
PROGRAMMING
FIELD
POSSIBLE
VALUES
DEFAULT
SETTINGS
Programming fields:
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
The following table shows a summary of the programming fields available, the possible values that the programming
fields can take by using the N3301/GB2 keypad and the default settings.
26
Managing proximity keys:
For resident proximity key access and management, the system must have an N3401/GB2 proximity access control
module. .TK3401/GB2 key kit not included
IMPORTANT: It is necessary to initially activate the MASTER CARD ADD and MASTER CARD DELETE keys on the
door panel to be managed .before residentkeys can be added/deleted
(Step 2)
(Step 3)
With the EL632/GB2A module connected and operating, set its DIP 4 to the
OFF position. (At the end of programming, it must be returned to its initial position, for buildings/OFF for houses).
1 2 3 5 6
4
ON
Activating MASTER CARD keys on the door panel:
Using the DIP 4 located on the EL632/GB2A module, perform the following sequence:
1 2 3 5 6
4
ON
1 2 3 5 6
4
ON
1 2 3 5 6
4
ON
1 2 3 5 6
4
ON
ON
OFF
ON
OFF
At the end of the sequence, communication indicator and door open indicator will illuminate.
You then have 10 seconds to perform the following step.
Set the DIP 4 on the EL632/GB2A module to the initial position and remove the short circuit between
AP+ and AP-: ON for buildings
OFF for houses
1 2 3 5 6
4
ON
1 2 3 5 6
4
ON
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
(Step 4)
Hold the MASTER CARD ADD key near to the proximity reader located on the N3401/GB2 module and,
once stored, communication indicator will turn off and the door panel will emit a confirmation tone.
Then hold the MASTER CARD DELETE key near to the proximity reader located on the N3401/GB2
module and, once stored, door open indicator will turn off and the door panel will emit a confirmation
tone.
(Step 5)
NA2
+
AP-
C1
NA1
AP+
Relay 2Relay 1
_
12Vdc
The same MASTER CARD keys can be added to as many door panels as necessary.
Proximity keys for residents can then be added/deleted as indicated in the following section.
(Step 1)
NA2
+
AP-
C1
NA1
AP+
Relay 2Relay 1
_
12Vdc
Cause a short circuit between the AP+ and AP- terminals of Relay 1
on the EL632/GB2A module.
To the FA-GB2/A
power supply.
27
Managing proximity keys:
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
For resident proximity key access and management, the system must have an N3401/GB2 proximity access control
module. .TK3401/GB2 key kit not included
IMPORTANT: It is necessary to the MASTER CARD ADD and MASTER CARD DELETE keys on theinitially activate
door panel to be managed as indicated in the following section.before resident keys can be added/deleted
Adding resident keys:
(Step 1)
Hold the MASTER CARD ADD key near to the N3401/GB2 proximity reader, communication indicator will
illuminate and the door panel will emit a long and then short tone to indicate that it is in 'Add resident
keys' mode.
(Step 2)
One by one, hold all of the keys to be added to the door panel near to the N3401/GB2 proximity reader.
The door panel will emit a long tone each time it stores a proximity key or two short tones if the key has already been stored. A maximum of 320 access keys can be stored.
(Step 3)
Once all resident proximity keys have been added, complete the process by holding the MASTER CARD
ADD key near to the N3401/GB2 proximity reader. Communication indicator will turn off and the door panel will emit a short and then long tone to indicate that it has exited mode.'Add resident keys'
Deleting resident keys:
(Step 1)
Hold the MASTER CARD DELETE key near to the N3401/GB2 proximity reader, communication
indicator will illuminate and the door panel will emit a long and then short tone to indicate that it is in
'Delete resident keys' mode.
(Step 2)
One by one, hold all of the keys to be deleted from the door panel near to the N3401/GB2 proximity
reader. The door panel will emit a long tone each time it deletes a proximity key or two short tones if the key does not exist on the door panel.
(Step 3)
Once all resident proximity keys have been deleted, complete the process by holding the MASTER CARD
DELETE key near to the N3401/GB2 proximity reader. Door open indicator will turn off and the door panel will emit a short and then long tone to indicate that it has exited mode.'Delete resident keys'
Activating/deactivating the proximity reader:
To activate or deactivate the proximity reader, the same procedure needs to be followed; if it was initially activated it
will be deactivated and if it was initially deactivated after the process, the proximity reader will be activated.
(Step 1)
Hold the MASTER CARD ADD key near to the N3401/GB2 proximity reader, communication indicator
will illuminate and the door panel will emit a long and then short tone to indicate that it is in 'Add resident
keys' mode.
(Step 2)
Then hold the MASTER CARD DELETE key near to the N3401/GB2 proximity reader, door open
indicator will illuminate and the door panel will emit a long and then short tone to indicate that it is in
'Activate/deactivate proximity reader' mode.
(Step 3)
Finally, hold the MASTER CARD DELETE key again to the N3401/GB2 proximity reader to
activate/deactivate the proximity reader. The door panel will emit a long tone to indicate that it has been correctly modified.
Continued overleaf
28
Then hold the MASTER CARD ADD key near to the N3401/GB2 proximity reader, communication
indicator will illuminate and the door panel will emit a long and then short tone to indicate that it is in 'Delete all proximity keys' mode.
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Managing proximity keys:
Deleting all resident proximity keys:
(Step 1)
Hold the MASTER CARD DELETE key near to the N3401/GB2 proximity reader, communication
indicator will illuminate and the door panel will emit a long and then short tone to indicate that it is in
'Delete resident keys' mode.
(Step 2)
(Step 3)
Finally, hold the MASTER CARD ADD key again to the N3401/GB2 proximity reader to confirm deletion of
all resident keys from the door panel. During the deletion process, the communication and door open indicators will blink. When complete, they will turn off.
Continued from previous page
29
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Managing the apartment list:
It is possible to display a contacts list on the EL3422/GB2 TFT screen module, selected using the selection keys on the
N3401/GB2 module, and make a call by pressing the bell button on the same module.
The apartment list can be created using the 'Address Manager GB2' program, available for download from
https://doc.golmar.es. By means of 'Address Manager GB2', it is also possible to reassign the terminal to which buttons 1 and 2 of the EL632/GB2Amodule and the buttons of the EL610D modules, if any, make the call.
(Step 1)
Press the button to create a new project indicating the information related to the installation. This'New 'site
can be one building or several with similar characteristics, an area with a general panel and several buildings inside or even an entire block of buildings independent of each other. That way, the scope of the definition of the project can be decided by the designer of the project.
(Step 3)
Create a new door panel by clicking on the button located below the fields of the project'New panel'entry
header, and indicate all of the information concerning the door panel, as well as the door panel operating mode (see pp. 7 and 8) and the number of EL610D modules that it has (0 in the case of a coded panel).
(Step 2)
Once the project information has been completed, click the 'Save' button located next to the 'New 'site
button.
Once the configuration of the door panel is finished, press to save the new information. It then' 'Save
appears in the project's door panel table and is accessible to create new contacts.
Continued overleaf
Generating a contacts list:
30
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Managing the apartment list:
Continued from previous page
(Paso 4)
Then double-click on the list of the door panel to be modified to show its information, DIP switch
configuration, operating mode and available modules.
EL632/GB2A sound module operating mode
EL632/GB2A module DIP switch conguration
EL632/GB2A module
N3301/GB2 module
(Step 5)
To assign a contact to the buttons of the EL632/GB2A module, click on the EL632/GB2A module icon. To
add a contact to the list that does not depend on the buttons of the EL632/GB2A module, click on the N3301/GB2 module icon.
For each case, a different window will be displayed:
In the first case, a window will be displayed where the buttons of the module are located:
In the second case, a list of existing contacts will be displayed:
Continued overleaf
31
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Managing the apartment list:
Continued from previous page
(Step 6A)
To assign a contact to a button on the EL632/GB2A module, click on the corresponding button in the
module window, and a new window will be displayed. This enables the information relating to the indicated button to be edited.
(Step 6B)
To assign a contact to apartment list of the N3301/GB2 module, click on the button located in the top' 'Add
left of the window, and a new window will be displayed. This enables the information relating to the new contact to be edited.
(Step 7)
Then fill in the contact details, indicating:
 ' 'Dialling code : Code entered on the N3301/GB2 keypad to make the call.  ' 'Description : Description of the apartment (ground floor 1, first floor 2, attic floor 3, etc.)  ' 'RD-GB2/A module number: Enter the code of the module in which the terminal (1-8) is located.  ' 'Apartment unit number: Enter the code that the terminal to be associated will have (1-32) or (1-128).
Finally, click on the button to assign the changes to the indicated button or add the contact to the'Save'
list.
IMPORTANT:
 The can only be assigned if the previous step is '(Step 6B)', otherwise it' 'Dialling code
will be configured with an assigned value that corresponds to the button code depending on the configuration selected for the EL632/GB2A module.
A.
The module code can be changed if the door panel has been configured in'RD-GB2/A'
'Router' 'Gateway'or mode.
Continued overleaf
32
Once the apartment list has been edited, the list will be displayed. It can be edited by doubleentries
clicking on the contact to change it if any detail is not correct.
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Managing the apartment list:
Continued from previous page
(Step 8)
Finally, close the window to display the window again.' ' ' panel'Code panel Entry
From the ' ' window, it is possible to generate a configuration file containing the information thatEntry panel
will be transferred to the EL632/GB2A module by means of the button. It is also'Save to SD card' possible to generate a file containing the configuration of the DIP switches on the terminals and RD­GB2/A by means of the button.' TXT configuration 'Create file
Press the button to save the information to the micro SD card. Select the root of the'Save to SD card'
micro SD card from the folder manager displayed, click on the 'Save' button and a 'Namelist.bin' folder will be automatically generated with a 'Namelist.txt' file inside it, which will contain the information necessary to add the contacts list and configure the buttons if it has been modified.
IMPORTANT: For correct operation, DO NOT change the name of the 'Namelist.bin' folder or the
'Namelist.txt' file inside.
(Step 9)
Continued overleaf
33
PROGRAMMING THE DOOR PANEL
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
Managing the apartment list:
Continued from previous page
Transferring contacts list and configuring buttons on the EL632/GB2A module:
(Step 1)
With DIP 6 of the EL632/GB2A module in the OFF position, disconnect the power supply
of the EL632/GB2A module.
(Step 2)
Set DIP 6 of the EL632/GB2A module to ON.
1 2 3 4 5
6
ON
ON
1 2 3 4 5
6
ON
(Step 3)
Reconnect the power supply of the EL632/GB2A module.
(Step 4)
Once busy channel indicator has been turned off, the user has 10 seconds to insert the micro SD
card into the slot on the top left of the back of the EL632/GB2A module and press until it clicks.
Communication indicator will illuminate and the door panel will beep to indicate that the information
dump process has started.
(Step 5)
When the process is complete, communication indicator will turn off and the door panel will beep.
(Step 6)
Set DIP 6 of the EL632/GB2A module to the OFF position and remove the micro SD
card by pressing it again.
(Step 7)
1 2 3 4 5
6
ON
OFF
Micro
SD
NA2
+
AP-
C1
NA1
AP+
C2
AP+
AP-
P1
P2
BUS
BUS
Relé 2
Relé 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+
AP-
P1
P2
BUS
BUS
Relé 2
Relé 1
_
12Vdc
34
WIRING DIAGRAMS
Video door entry system with 23 VESTA2 monitors, 12 D2L-GB2 distributors and Golmar DC lock release.
Configure the end of line in the last monitor. DIP 6 to ON.
BUS
BUS
BUS BUS
D2
D1
D2L- 2GB
BUS
BUS
BUS
BUS
BUS BUS
D2
D1
D2L-GB2
BUS
End of line
ON
APARTMENT 4 APARTMENT 3
Remove the jumper from all of the distributors except the last.
BUS
BUS
BUS BUS
D2
D1
D2L- 2GB
BUS
BUS
APARTMENT 2 APARTMENT 1
Leave the jumper in this position for 4,3" GB2 monitors of all of the D2L-GB2 distributors.
(1)
OFF
(1)
End of line
OFF
End of line
(1)
(1)
Distances and cross-sections:
D2L- 2GB
Twisted pair 2x0.75mm
2
60mA60mB30m
C
80m 80m 40m
Cable
10m
D
15m
APARTMENT
23
A
C
B
C
D
VESTA2
FA- 2GB /A
VESTA2
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA.
ON
1 2 3 4 5 6
AP
SW1
(2)
(2)
Mains
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
Access panel
( )2
Important:
For the connection of an AC lock release or a 2nd lock release, see page 38. For more information about the VESTA2 monitor, see the Quick Guide enclosed with its corresponding product.
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
VESTA2
Master
( )3
**
( )
( )3 ( )3
**
( )
**
( )
( )3 ( )3
**
( )
**
( )
( )3**( )
*
( )
*
( )
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
RAP-2150 (twisted pair 2x1mm )
2
4
( )
4
( )
Distances with Golmar cable (twisted pair 2x1mm ).RAP-2150
2
35
WIRING DIAGRAMS
Audio door entrysystemwith 128 apartments/NHEAhands-free audio terminals and Golmar DC lock release:
(The EL632 GB2Asound module should beset to 'operatingmode 2 and6' audio only, see pp. 7 and8).
Access panel
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA.
ON
1 2 3 4 5 6
AP
SW1
APARTMENT 1
Twisted pair 2x0.75mm
2
60mA60m
B
80m 80m
Cable
10m
C
15m
*
( )
*
( )
Distances and cross-sections:
A
C
B
APARTMENT 2
APARTMENT 128
Important:
.
For the connection of an AC lock release or a 2nd lock release, see page 38
( )
*
FA- 2GB /A
Mains
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
For more information about the NHEA hands-free audio terminal, see the Quick Guide enclosed with its corresponding product.
1
( )
1
( )
1
( )
1
( )
AUX
NHEA
AUX
NHEA
NHEA
Master
AUX
NHEA
Master
AUX
NHEA
Master
AUX
BUS
BUS
BUS
IMPORTANT:
-
The TNHEA telephone's DIP 10
should be set to ON.
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
RAP-2150 (twisted pair 2x1mm )
2
2
( )
2
( )
Distances with Golmar cable (twisted pair 2x1mm ).RAP-2150
2
36
BUSBUS
BUS BUS
D C B A
DP- 2GB A
End of line
OFF
AP AP
Access panel 2
ON
1 2 3 4 5 6
SW1
Access panel 1
ON
1 2 3 4 5 6
SW1
AP AP
Access panel 3
ON
1 2 3 4 5 6
SW1
Access panel 4
ON
1 2 3 4 5 6
SW1
(1) (1)
(1) (1)
Video door entry system: To the distributors (building floors) Audio door entry system: To the telephones (building floors)
Lock release
max. 12 Vdc/270mA.
Lock release
max. 12 Vdc/270mA.
Lock release
max. 12 Vdc/270mA.
Lock release
max. 12 Vdc/270mA.
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2
Relay 1
_
12Vdc
Important: For the connection of an AC lock release or a 2nd lock release, see page 38.
(1)
(1)
(1)
(1)
(1)
Video door entry system with 4 access panels, DP-GB2A distributor for door panels and Golmar DC lock release.
Mains
100~240Vac
N L
CN
BUS(M) BUS (PL)
FA- 2GB /A
L
Video door entry system: Leave the end of line in the OFF position. Audio door entry system: Set the end of line to ON.
( )
*
Important: (in this distributor).
( )
*
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
WIRING DIAGRAMS
37
Access panel
ON
1 2 3 4 5 6
SW1
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2Relay 1
_
12Vdc
AP1
Access panel
ON
1 2 3 4 5 6
SW1
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay
2Relay 1
_
12Vdc
Connection of 2 DC lock releases without 'AP':
Important: With 2 DC lock releases, it is not possible to use the APdoor release buttons.
(1)
To the FA-GB2/A
power supply
Mains
230Vac
SEC
~~ ~~
PRI
TF-104
Lock release
amax. 12 V c/850mA.
Lock release
amax. 12 V c/850mA.
Connection of 1 AC lock release with 'AP':
To the FA-GB2/A
power supply
Access panel
ON
1 2 3 4 5 6
SW1
NA2
+
AP-
C1
NA1
AP+
C2
AP+ AP-
P1 P2
BUSBUS
Relay 2Relay 1
_
12Vdc
(1)
To the FA-GB2/A
power supply
(1)
Lock release
max. 12 Vdc/270mA.
Connection of 2 AC lock release with 'AP':
SEC
~~ ~~
PRI
TF-104
AP1 AP2
Mains
230Vac
Connection of Golmar DC and AC lock releases.
Important: Place the varistor supplied with the sound module directly onto the terminals of the lock release.
( )
*
( )
*
Important: Place the varistors supplied with the sound module directly onto the terminals of the lock release.
( )
*
( )
*
( )
*
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
WIRING DIAGRAMS
38
NA2
+
AP-
C1
NA1
AP+C2AP+AP-
P1 P2
BUSBUS
Relé 2Relé 1
_
12Vdc
5 6 7 8
9 10
7
8
5
6
3
4
1
2
NA2
+
AP-
C1
NA1
AP+C2AP+AP-
P1 P2
BUSBUS
Relé 2Relé 1
_
12Vdc
SEC
~~ ~~
PRI
TF-104
Mains
230Vac
EL3002H/GB2
EL632/GB2A
EL610D
EL3002H/GB2
EL632/GB2A
N3301/GB2
NX3301/GB2
Connection if N3301/GB2 or NX3301/GB2 module exists Connection if EL610D button module exists
If the door panel has an N3301/GB2 or NX3301/GB2 module, it will not be necessary to power the EL3002H/GB2 module with an additional TF-104, as shown in the following diagram.
G 2 AUDIO AND VIDEO DOOR ENTRY SYSTEM - CODED PANELB
WIRING DIAGRAMS
Connection of the EL3002H/GB2 module
Connection of the EL3002H/GB2 auditory accessibility module.
Connection of the EL3002 illumination module.
SEC
~~ ~~
PRI
TF-104
Mains
230Vac
EL3002 EL3002 EL3002
39
golmar@golmar.es
www.golmar.es
Sistemas de comunicaciónS.A.
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis.
Golmar reserves the right to make any modifications without prior notice.
GOLMAR S.A.
C/ Silici, 13
08940- Cornellá de Llobregat
SPAIN