golmar 4130/AL, 4210/AL Instruction Manual

Stadio Plus
T4000EN
rev.0104
Audio
door entry system
Kits
4+'n' wires installation
First of all we would like to thank and congratulate you for the purchase of this product
manufactured by Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001
certification and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers. To obtain the maximum profit of these features and a properly wired installation, we kindly recommend you to expend a few minutes of your time to read this manual.
O
O O
To make a call the visitor should press the push button corresponding to the apartment he wishes
to contact. An acoustic tone will be heard confirming the call as the push button is pressed. At
this moment the call will be received at the telephone in the dwelling. To establish communication pick up the telephone handset. To open the door, press the door release push button at any moment.
O O
O
Do not use excessive force when tightening the transformer connector screws. Install the equipment without the power connected. Disconnect from power before any system
modification. Check that the input voltage is lower than 230Va.c. Before to connect the system, check the connections between door panel and telephones, and
the transformer connection. Do always follow the enclosed information.
O O O O
Audio system with 4 + N wires installation. Just 1 TF-104 transformer (12Va.c., 1.5A). Electronic call with acoustic acknowledgement signal. a.c. lock releases activation.
O Up to three telephones in the same apartment.
1
INTRODUCTION
SYSTEM CHARACTERISTICS
SYSTEM OPERATION
STARTING RECOMMENDATIONS
DOOR PANEL INSTALLATION
2
1650
1850
1450
The upper part of the door panel should be placed at 1,65m. height roughly. The hole dimensions will depend on the kit to be installed.
1 or 2 push buttons kits: 125(W) x 140(H) x 56(D) mm. 3 to 10 push buttons kits: 125(W) x 220(H) x 56(D) mm.
The door panel has been designed to be placed under most of the environmental conditions. However it's recommended to take additional cautions like rainproof covers.
DIN 46277
f3,5 x 25 DIN-7971
f3,5 x 25 DIN-7971
nstalling the TF-104 transformer.
I
To install the transformer directly on the wall, insert the fixing flanges. Drill two holes of Ø6mm. and insert the wallplugs. Fix the transformer with the specified screws.
The transformer can be installed on a DIN guide (3 units) simply pressing it. To disassemble the transformer from the DIN guide, use a plain screwdriver to lever the flange as shown on the picture.
The transformer must be installed in a dry and protected place. It's recommended to protect the transformer by using a thermo-magnetic circuit breaker.
POWER SUPPLY INSTALLATION
mbedding box positioning.
E
DOOR PANEL INSTALLATION
3
DOOR PANEL INSTALLATION
4
lace the nameplate labels.
P
Break the bottom flange
to pass the cables through.
reparing the embedding box.
P
Pass the wiring through the hole made in the bottom part of the embedding box. Level and flush the embedding box. Once the embedding box is placed, remove the protective labels from the attaching door panel holes.
old the door panel on the embedding box.
H
Select a direction to open the door panel; this selection should ease the door panel wiring. The opening direction will be settled through the hinges position, that must be passed through the header clips as shown. For example, if the hinges are placed on both clips of the lower header, the door panel will open downwards; if they are placed on the right clips of both headers, the door panel will open to left.
To hold the door panel on the embedding box,
insert the hinges in the embedding box lockers
as shown.
Open the label holder.
Place the label and close.
inal adjustments.
F
If after starting the system it's considered that the audio volume isn't correct, proceed with the necessary adjustments as shown.
Once the nameplate labels are placed, wire the lamps from different modules and connect them to terminals L1 and L2 of the sound module, as it's shown on the installation diagrams.
lose the door panel.
C
Fix the door panel by using the supplied screws.
Finish the door panel assembly by pressing the closing heads.
5
INSTALLATION DIAGRAM
6
escription of the T-900 telephone.
D
a. b. c. d. e.
f.
g.
a
d
c
e
e
g
f
b
TELEPHONE INSTALLATION
Telephone handset. Speaker grille. Microphone hole. Subjection hole. Telephone cord connectors. Door release push button. Hook switch.
To open the telephone insert a plain screwdriver into the slots and rotate it as shown.
Avoid to place the telephone near to heating sources, in dusty locations or smoky environments. The telephone can be fixed using an electrical embedding box or directly on the wall, as shown on the picture. If the telephone will be installed directly over the wall, drill two holes of Ø6mm. on the specified positions, using 6mm. wallplugs and Ø3,5 x 25mm. screws.
Pass the installation wires through the corresponding hole and connect them as shown on the installation diagrams.
Close the telephone as shown on the picture. Once the telephone is closed, connect the handset using the telephone cord and put it on the craddle.
CVCPL1L2
ind. 1
ind. 1
ind. 2
ind. 2 ind. 3
P
CN1
-
~1~2
TF-104
Stadio Plus
SEC
~~
PRI
~~
0010105533P1
P1
Main
SECTIONS CHART
ne access door.
O
ections chart.
S
0, ind, 5, , 10, , P, P1 0,25mm² 0,50mm²
0,50mm² 1,00mm² 1,00mm² 2,50mm²
Terminal 100m.
Maximum distance
300m.
–, 3
~1, ~2, CV
For longer distances than the specified contact with your distributor.
7
ind.
0 010 105 53 3P1 P1
arallel telephones installation.
P
The maximum number of telephones placed in the same apartment is three. For each telephone placed in parallel the section corresponding to the call wire must be doubled.
OPTIONAL CONNECTIONS
TROUBLESHOOTING HINTS
xternal lock release activation.
E
The lock release can be activated at any moment by using an external push button, that must be connected between '–' y 'P' terminals of the main module. This function will allows to exit from the building being not necessary the use of a key.
O Nothing operates.
w Check the output transformer voltage between SEC terminals: it should have 12 to 17Va.c. If
not, disconnect the transformer from the installation and measure again. If it's correct now, it means there is a short circuit in the installation: disconnect the transformer from mains and check the installation.
O Inappropriate audio level.
w Adjust the level volumes as shown on page 4. In case of feedback, reduce the audio levels
until feedback fade out.
O Door open function no operates.
w Disconnect the lock release from the sound module and short-circuit terminals ' ' and 'P': at
that moment the output voltage between terminals 'CV' and '~2' of the sound module should be 12Va.c. If it's so check the lock release, its wiring and the wiring of the terminal 'P' from the sound module to the telephones. If these tests don't solve the problem, replace the sound module.
O No telephones receive the call or acknowledgement call signal is not reproduced.
w Check that the push buttons common terminal are correctly connected to the 'CP' terminal of
the sound module.
CVCPL1L2 P
-
~1~2
Golmar reserves the right to make any modifications without prior notice.