Goldline GLDUAL 704 BZNG-Cast, GLDUAL 4 BZNG-Cast, GLDUAL 5 BZNG-Cast, GLDUAL 704 BZLPG-Cast, GLDUAL 4 BZLPG-Cast Installation Instructions & Use & Care Manual

...
4 BURNER GAS HOBS
4 BURNER GAS HOBS 5 BURNER GAS HOBS
GLDUAL 704 BZNG-Cast GLDUAL 4 BZNG-Cast GLDUAL 5 BZNG-Cast GLDUAL 704 BZLPG-Cast GLDUAL 4 BZLPG-Cast GLDUAL 5 BZLPG-CAST GLDUAL 704 WZNG-Cast GLDUAL 4 WZNG-Cast GLDUAL 5 WZNG-Cast GLDUAL 704 WZLPG-Cast GLDUAL 4 WZLPG-Cast GLDUAL 5 WZLPG-Cast
&
USER AND OPERATOR INSTRUCTIONS
Installation must be in accordance with manufacturer’s instruction, relevant Gas
Fitting Regulations or AS5601 – “Gas Installation” regulations. These instructions should be read carefully prior to initial use and retained in a safe
place in order that full advantage can be taken of the features of your HOB COOKER.
REMINDER:
ANY SERVICING AND INSTALLATION OF THE HOTPLATE
MUST BE CARRIED OUT BY AN AUTHORIZED PERSON.
ANY QUERIES SHOULD BE FORWARDED TO:
MANUFACTURER: A’VARD INDUSTRIES P/L. ADDRESS: 58-60 Quantum Close, South Dandenong, Victoria 3175, Australia. TEL: 61 3 9799 9660 FAX: 61 3 9799 9662 WEBSITE: www.goldlinecorp.com.au
Goldline GLDUAL manual April 2015 2
Goldline GLDUAL manual April 2015 1
CUT OUTS
INSTALLATION INSTRUCTIONS
DATA PLATE DETAILS: The data plate is located on the tray floor.
CHECK THAT THE DATA PLATE SHOWS THAT THE APPLIANCE IS SUITABLE FOR THE AVAILABLE GAS SUPPLY. IMPORANT: VERIFY GAS TYPE WITH LOCAL GAS NETWORK OPERATOR BEFORE CONNECTION OF THIS APPLIANCE.
Model GLDUAL 4
Diagram A
Tray Dimensions (in mm)
Diagram B
Cut-Out (in mm)
Diagram A
Tray Dimensions (in mm)
Diagram B
Cut-Out (in mm)
Model
GLDUAL 704
Model GLDUAL 5
Diagram A
Tray Dimensions (in mm)
Diagram B
Cut-Out (in mm)
3 Goldline GLDUAL manual April 2015
1. Room Ventilation This cooktop must be installed in a room that has permanent ventilation to effect the correct operation of the appliances and also to provide adequate ventilation. This airflow must exceed 20m³ via permanent vented openings in the walls of the room and these must have a section of 100cm² minimum. They must be constructed in a manner so as to avoid any possible blockages. The airflow can also be drawn indirectly from an adjacent room provided it complies with any local regulations to vent any fumes outdoors.
Not for use in Marine craft, caravans or Mobile homes unless fitted with safety device.
2. Before installing the appliance check that the location provides the required clearances
from combustible materials and if necessary provide protection to adjacent surfaces as required by the regulations. Make provision for the gas supply to be connected in the position shown in D
iagram
A.
3. Cut the opening in the bench top to the dimensions shown in diagram B.
4. Remove the hotplate from the carton.
5. Install the hotplate in the cut-out (see diagram B on page 2).
Note:
If clearance between side and rear walls and periphery of the burner is less than 250mm, the walls must be protected with a non-combustible material. The protection must extend a minimum distance of 450mm above the burner. Horizontal surfaces less than 750mm vertically above the hotplate must also be protected.
6. Ensure that gas and electrical outlet are accessible with the appliance installed. The gas connection to the regulator is 1/2” BSP. Please ensure gas supply line to the appliance is of adequate length to allow sufficient withdrawal of appliance for service or disconnection. The connection must be annealed copper pipe or flexible hose (if permissible by local authority).
Note: The cook top must be installed with provision to allow the gas to be turned off and
disconnected for servicing
and r
emoval of the appliance as required from gas supply.
7. Use a spanner at the flat area provided to hold the regulator firmly, when making the
join. Refer diagram below.