Golden Vantage 1801(A), 1802, GV-SR01, 1801 Installation Instructions Manual

30" AND 36" UNDER CABINET-MOUNT
RANGE HOOD
Model:
1801(A)
1802
GV-SR01
Universal Installation Instructions and Use & Care Guide
For questions about features, operation/performance parts, accessories or service, call:
1-626-453-0550
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY.
Revised September 2014 Disclaimer: Item purchased may be slightly different from the manual.
1
TABLE OF CONTENTS
RANGE HOOD SAFETY ....................................................................3
INSTALLATION REQUIREMENTS ...................................................4
Tools and Parts Requirements ...................................................4
Location Requirements .............................................................4
Installation Dimensions ............................................................5
Ventilation Requirements .........................................................6
Electrical Requirements ............................................................7
INSTALLATION INSTRUCTIONS ..................................................8
Prepare ......................................................................................8
Install Range Hood ...................................................................9
Complete Installation ..............................................................11
RANGE HOOD USE .........................................................................12
Range Hood Controls ..............................................................12
TROUBLE SHOOTING ...................................................................13
RANGE HOOD CARE ......................................................................14
Cleaning .................................................................................
Cleaning .................................................................................14
Maintenance ...........................................................................15
Replacement ...........................................................................15
WARRENTY & SERVICES .............................................................16
2
RANGE HOOD SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.”
These words mean:
DANGER
W
ARNING
You can be killed or seriously injured if you don't immediately follow instructions.
You can be killed or seriously injured if you don't instructions.
follow
I
MPORTANT SAFETY INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, READ THE FOLLOWING:
e this unit only in the manner intended by the
Us
manufacturer. If you have questions, please contact the manufacturer.
Before servicing or cleaning the unit, switch the power off
and lock the service panel. This will prevent the power from accidentally turning on. If the service panel does not lock, secure a warning label, such as a tag, to the service panel.
Installation work and electrical wiring must be done by a
qualified professional(s) in accordance with all applicable codes, standards, and fire-rated constructions.
Do
not operate any fans with a damaged cord or plug. Discard the fan or return to an authorized service facility for further examination and/or repair.
To prevent back draft, sufficient air is needed for proper combustion. Gas from fuel burning equipment needs to exhaust through the flue (chimney). Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
When cutting or drilling into walls or ceilings; be aware of
electrical wires, piping, and other utilities.
Ducted fans must always be vented outdoors.
CAUTION: For general ventilation use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce the risk of fire and to properly
exhaust air, be sure to duct air outside - DO NOT vent exhaust air into attics, crawl spaces, garages, or within walls and ceilings.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE, READ THE FOLLOWING:
Never leave surface units unattended at high settings. Boil-over can cause smoke and grease to spill over that may ignite. Heat oils slowly on low or medium settings.
Always turn the hood ON when cooking at high heat or
when flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
Cle
an ventilation fans frequently. Grease should not be
allowed to accumulate on fan or filter.
Use proper pan size. Always use cookware
appropriate for the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY. IN
THE EVENT OF A RANGE TOP GREASE FIRE, READ THE FOLLOWING:
SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
NEVER PICK UP A FLAMING PAN - you may be burned.
DO NOT USE WATER, including wet dishcloths or towels ­a violent steam explosion will result.
Use an extinguisher ONLY if:
You know you have a class ABC extinguisher, and you
already know how to operate it.
– The fire is small and contained in the area where it
started.
The fire department is being called. You can fight the fire with your back to an exit.
Based on "Kitchen Fire Safety Tips" published by NFPA.
W
ARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control device.
3
INSTALLATION REQUIREMENT
TOOLS AND PARTS
REQUIREMENTS
Electrical drill or ratchet driver
1/2” drill bit for drilling pilot holes
1 ¼” drill bit for drilling electrical wiring access
hole.
Screwdrivers: Philips & Straight blade
Pliers
Tape measure or ruler and pencil
Electrical supplies for wiring
Aluminum foils tape and/or duct tape
Hammer
Jigsaw or saber saw
M5 x 60 QTY:6
8 x 50 Wall anchor QTY:6
Washer QTY:4
M5 x 10 QTY:4
Stud finder
Parts Supplied
Body 1 Pc
Chimney mounting bracket 2 Pc
Installation manual 1 Set
Metal grease filter 2-3 Pcs
Hardware 1 Set
Disclaimer: Screws many vary from model to model.
LOCATION REQUIREMENTS
IMPORT
and ordinances. Have a qualified technician
install the range hood. It is the installer’s
responsibility to comply with installation clearances specified on the model/serial rating plate.
Canopy hood's location should be away from strong draft areas, such as windows, doors, and strong heating vents. Cabinet opening dimensions that are shown must
be used. Given dimensions provide minimum clearance.
ANT: Observe all governing codes
4
INS
TALLATION DIMENSIONS
Countertop height
A. B. Hood height from ceiling to bottom of the range hood filter surface: D-A-C=B C. 27” min. from cooking surface, suggested 30” max. D. Ceiling height